Search PubMedSearch

SEARCH · Search PubMed

Results for “bulk‐fill technique”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

205 records · Page 6Linked to original sources

Spatially confined electrochemical strategy with DNA-assembled nanogaps for SNP detection.

Accurate detection of low-abundance single nucleotide polymorphisms (SNPs) against a large excess of homologous wild-type sequences requires both selective molecular recognition and effective transduction of small sequence differences into measurable signals. Here, we report a spatially confined electrochemical strategy that couples sequence-selective recognition with size-dependent mass-transport gating. DNA-hybridization-driven self-assembly of gold nanoparticles (AuNPs) forms a three-dimensional self-assembled electrode (3D-SAE) with a DNA-defined interparticle architecture. Competitive probes (SP/WP) convert single-base recognition into distinct molecular-size states: the SNP-associated pathway preferentially triggers a hybridization chain reaction (HCR), generating bulky AuNP-anchored HCR/methylene blue complexes (Au@HCR/MB) with reduced electrochemical accessibility through the porous 3D-SAE, whereas the wild-type pathway does not trigger HCR and maintains a high-current response from more readily accessible MB-containing species. Thus, sequence recognition is translated into a molecular-size difference and subsequently into an electrochemical signal through differential mass transport. Under buffer conditions, the platform achieved a statistically estimated detection limit of ∼0.47 fM and a quantitative range of 1 fM-100 pM. It discriminated a 0.1% mutant abundance in a fragmented genomic-DNA background. The downstream signal-transduction chemistry is enzyme-free and isothermal. This work establishes a mechanistical recognition-size-conversion-mass-transport-gating architecture for electrochemical nucleic acid analysis.

Polymorphism, Single Nucleotide

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (≥ 13 mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2 = 0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2 = 59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

Rational design of high-productivity perfusion processes for CHO Cells: From growth inhibitory strategies to model-driven optimization.

While perfusion culture for Chinese hamster ovary (CHO) cells offers advantages such as continuous operation and flexibility, it suffers from product loss through cell bleeding and difficulties in reaching high productivity due to sustained rapid cell growth. Growth inhibitory strategies are widely used to enhance productivity in fed‑batch processes; however, their practical implementation and comparative effectiveness in perfusion processes remain insufficiently explored. Meanwhile, process development often relies on costly trial‑and‑error approaches. Here, we systematically compared three growth inhibitory strategies in perfusion culture-low cell‑specific perfusion rate (CSPR), sodium butyrate, and mild hypothermia-with respect to cell growth, metabolism, productivity, and product quality. Genome‑scale metabolic flux sampling analysis revealed that low‑CSPR and sodium butyrate induce a convergent up‑regulation of energy metabolism, correlating with greater gains in specific productivity (qp). Building on this insight, we developed a growth‑kinetic model for the combined low‑CSPR + butyrate strategy, incorporating parameter uncertainty. This model‑guided framework enabled the rational design of two distinct high‑productivity perfusion processes: a sustained mode that achieved robust long‑term stability alongside substantial productivity gains, and a high‑intensity mode that pushed qp and daily volumetric titer to their maxima, with increases of up to 108.94% and 190.36%, respectively, in a model CHO cell line with a moderate baseline productivity. Our study provides a proof‑of‑concept framework for perfusion intensification, from strategy selection to rational process design.

Animals

Hysteroscopic platelet-rich plasma and medically assisted reproduction outcomes: a systematic review and SWOT analysis.

BACKGROUND: Platelet-rich plasma (PRP) has been proposed as an adjuvant treatment in reproductive medicine. While most evidence refers to blind intrauterine instillation, subendometrial administration under hysteroscopic guidance allows targeted delivery under direct visualisation. This systematic review aimed to synthesise the available evidence on hysteroscopic PRP administration and its impact on clinical medically assisted reproduction (MAR) outcomes. METHODS: A systematic search was conducted from inception to December 2025 across major databases. Studies were included if they evaluated hysteroscopic PRP administration in women undergoing MAR, comparing reproductive outcomes between treated and control groups. RESULTS: Out of 142 records, 3 studies met the inclusion criteria. Study populations were heterogeneous and included women with refractory thin endometrium and/or a history of implantation failure. Hysteroscopic PRP administration protocols varied in timing, technique, and dosage. In a prospective case-control study, hysteroscopic intraendometrial PRP injection at a depth of 2-3 mm in the four uterine walls, using an ovum aspiration needle, on days 11-13 of the cycle prior to euploid frozen embryo transfer (ET), was associated with higher implantation (IR), clinical pregnancy (CPR), and live birth rates (LBR) compared with standard therapy. Conversely, no significant differences in CPR, miscarriage rate, or LBR were observed in an observational study evaluating a single intraendometrial PRP injection (35-40 mL, 2-3 mm depth), administered via endoscopic needle on days 6-8 of the menstrual cycle preceding frozen ET, alone or after electrical impulse therapy. A randomised controlled trial in women undergoing intrauterine insemination reported a significant improvement in CPR following hysteroscopic subendometrial PRP instillation in the four uterine walls (1.0 mL each). CONCLUSIONS: Current literature on hysteroscopic PRP administration in reproductive medicine is limited, and robust conclusions cannot yet be drawn. Well-designed randomised controlled trials with standardised protocols are needed to clarify its clinical role.

Humans

The effect of nutrition education interventions on dialysis patients' outcomes: a systematic review and meta-analysis.

BACKGROUND: Non-adherence to dietary and fluid restrictions among dialysis patients is associated with adverse clinical outcomes. Quantifying the effectiveness of nutrition education interventions can inform practice and policy. METHODS: We searched MEDLINE, EMBASE, CINAHL, CENTRAL, PsycINFO, Web of Science, and Scopus up to 15 July 2025, supplemented by trial registries and Google Scholar, with an updated search through 8 April 2026. Eligible studies included randomized and non-randomized trials evaluating nutritional education interventions in adult dialysis populations. Risk of bias was assessed using RoB-2 and ROBINS-I, certainty graded using GRADE, and random-effects meta-analyses conducted alongside subgroup, sensitivity, and meta-regression analyses. Publication bias was assessed with Egger and Begg tests and trim-and-fill where applicable. RESULTS: Forty-four studies comprising 4,106 participants were included. Nutrition education significantly improved knowledge (SMD = 1.09; 95% CI: 0.67-1.51) and health-related quality of life (SMD = 1.43; 95% CI: 0.86-2.00; I² = 0%), and reduced serum potassium (SMD = -0.52; 95% CI: -0.91 to -0.14; I² = 92%) and serum phosphate (SMD = -0.35; 95% CI: -0.56 to -0.15; I² = 81%). Results for albumin, creatinine, sodium, calcium, and BUN were inconsistent and non-significant. Most outcomes were rated low or very low certainty by GRADE, reflecting inconsistency, indirectness, and imprecision. Potential publication bias was identified for certain outcomes. CONCLUSIONS: Nutrition education consistently improves knowledge and quality of life and may modestly reduce serum phosphate and potassium in dialysis patients. High-quality registered trials with standardized outcomes and longer follow-up are needed to establish effectiveness and sustainability. PROSPERO REGISTRATION: CRD420251119567.

Humans

Effect of SGLT2 inhibitor drugs on triglyceride-glucose (TyG) index in adults: A systematic review and meta-analysis.

BACKGROUND: Insulin resistance is a serious public health concern. The triglyceride-glucose (TyG) index is a simple, cheap, and reproducible surrogate of insulin resistance, and sodium-glucose cotransporter-2 (SGLT2) inhibitors have reshaped cardio-metabolic care beyond glycemic control. METHODS: We followed PRISMA and registered the protocol in PROSPERO (CRD420251056341). We searched PubMed, Scopus, Web of Science, EMBASE, and Cochrane from inception to May 31st, 2026, including observational studies and clinical trials reporting baseline and follow-up TyG in adults. Two reviewers screened records, a third resolved disagreements, data were extracted with a standardized form, and quality was assessed with Cochrane RoB 2.0, the Newcastle-Ottawa Scale, and the JBI checklists. The primary outcome was within-group change in TyG pooled with random-effects (Hartung-Knapp); tests were two-sided with a significance threshold of 0.05. RESULTS: Twelve studies comprising thirteen study arms were included, with a total of 1845 participants. Follow-up ranged from 12 weeks to 5 years. Across studies, SGLT2 inhibitor therapy was associated with a significant reduction in TyG index (mean difference = -0.28, 95% confidence interval [-0.41; -0.14], I2 = 99.5%). Egger's test suggested possible small-study effects, whereas Begg's test and trim-and-fill analysis did not show clear evidence of publication bias; leave-one-out analyses showed that no single study materially influenced the pooled estimate. CONCLUSION: Despite heterogeneity in populations, drug choice, and follow-up duration, SGLT2 inhibitors were associated with a significant decrease in TyG, although small-study effects cannot be excluded.

Humans

Quantitative N-glycoproteomic analysis reveals glycosylation signatures of plasma immunoglobulin G in sepsis.

INTRODUCTION: Sepsis is a life-threatening condition resulting from organ dysfunction due to a dysregulated immune response to infection. Immunoglobulin G (IgG) plays a role in modulating immune responses. However, the precise IgG subclass-specific N-glycosylation profiles in patients with sepsis remain poorly characterized. METHODS: This study aimed to define the site-specific N-glycosylation signatures of plasma IgG subclasses in sepsis patients with different prognoses using quantitative glycoproteomics. By employing our established GlycoQuant strategy, we quantified the intact N-glycopeptides (IGPs) of IgG subclasses in 40 healthy controls and 40 sepsis patients with a clear prognosis. RESULTS: We identified 12 IGPs with altered abundances between patients with sepsis and healthy controls. After Benjamini-Hochberg (BH) correction of the 31 outcome-stratified IGP comparisons, IGP24 and IGP25 remained significant and met the prespecified fold-change criterion. Global BH correction across 124 IGP-clinical parameter correlations retained positive associations of IGP19, IGP22, and IGP23 with procalcitonin (PCT). In exploratory outcome-stratified ROC analyses, candidates were selected using the original unadjusted P-value and fold-change screen; five IGPs were evaluated, with IGP25 and IGP24 yielding the highest individual AUCs. Collectively, our findings underscore the potential of IgG subclass-specific glycosylation profiling as a novel translational approach for clinical applications in sepsis management. SIGNIFICANCE: Sepsis remains a leading cause of global mortality, with patient outcomes heavily dependent on timely diagnosis and accurate prognosis. The dysregulated host immune response, particularly involving immunoglobulins, is central to its pathophysiology. This study provides a significant advance in the field of clinical glycoproteomics by applying a quantitative, site-specific strategy to delineate the plasma IgG subclass N-glycosylation landscape in sepsis. We report, for the first time, a panel of subclass-specific intact IgG N-glycopeptides (IGPs) that are significantly altered in sepsis patients compared to healthy controls. The identified IGPs not only demonstrate diagnostic and prognostic potential but also show a significant correlation with procalcitonin, a key clinical severity index. These findings bridge a critical knowledge gap by moving beyond bulk IgG glycosylation analysis to subclass-resolved profiling, offering novel molecular insights into sepsis immunopathology. The identified glycosylation signatures hold substantial translational promise as a foundation for developing innovative, glycan-based biomarker panels to improve the precision management of this heterogeneous and life-threatening syndrome.

Humans

The musculoskeletal pain literacy questionnaire (MSK-PLq) - Part 1: Development of a preliminary version through a systematic review and Delphi consensus.

OBJECTIVE: Chronic musculoskeletal (MSK) pain is a leading cause of disability worldwide, and self-management is a first-line approach recommended by international clinical guidelines. Access to evidence-based information that enhances health literacy may support patients' engagement in their self-management and treatment decision-making, potentially reducing disease burden and pain. However, no tool currently exists to assess health literacy specifically in MSK pain. This study aimed to develop and describe the preliminary version of a knowledge-based questionnaire to evaluate MSK pain literacy, the Musculoskeletal Pain-Literacy questionnaire (MSK-PLq). METHODS: A systematic literature review identified existing health literacy instruments and generated a preliminary list of domains. A two-round Delphi study with 22 panellists (19 experts and three people living with chronic MSK pain), followed by consensus meetings, was used to refine domains and items (≥70% agreement). Readability was assessed using the Flesch Reading Ease (FRE) score and three stakeholders were consulted to review the questionnaire for comprehensibility, clarity, and face validity. RESULTS: Six domains were retained (Understand, Access, Appraise, Apply, Digital, Beliefs), comprising 20 items in the preliminary version of MSK-PLq. Readability was acceptable (mean FRE 74, indicating fairly easy reading), and subject feedback supported the questionnaire's clarity and face validity. CONCLUSIONS: The preliminary version of the MSK-PLq is proposed as the first knowledge-based tool to assess functional, interactive, and critical aspects of MSK pain literacy. It may have applications in clinical practice, research, education, and digital health, by informing tailored patient education and supporting self-management strategies, although further psychometric validation is required.

Humans

Incidence and risk factors for malignancy in patients with incidental solitary pulmonary nodules: a systematic review and meta-analysis.

BACKGROUND: The increasing use of chest imaging has led to a higher detection rate of incidental solitary pulmonary nodules (SPNs), often causing patient anxiety. Determining the malignancy rate and associated risk factors is crucial for developing appropriate follow-up strategies to prevent overdiagnosis, overtreatment, or missed diagnoses. This meta-analysis aims to investigate the malignancy rate and risk factors in patients with incidental SPNs. METHODS: A systematic search of PubMed, Embase, Web of Science, and the Cochrane Library was conducted up to June 30, 2025. Data on malignancy rates and potential risk factors were extracted from eligible studies. All pooled analyses were performed using a random-effects model. RESULTS: Fifty-four studies involving 19,985 patients were included. The pooled malignancy rate for incidental SPNs was 56.7% (95% CI: 51.5-62.0), with significant between-study heterogeneity (I2 = 98.5%, p&#x2009;<&#x2009;0.001). The pooled effect size showed a minimal change after adjustment for potential publication bias using the non-parametric Trim-and-Fill method (54.7%; 95%CI: 50.9-58.8). Risk factor analysis identified that older age, history of cancer, cigarette smoker, larger nodule diameter, spiculation, upper lobe location, lobulation, pleural indentation, vascular convergence, solid nodules, family history of cancer, and irregular or ill-defined margins were significantly associated with an increased risk of malignancy. Conversely, male sex, presence of calcification, and clear borders were significantly associated with a reduced risk of malignancy. CONCLUSION: This meta-analysis provides a comprehensive assessment of malignancy rates and risk factors in incidental SPNs. The high pooled malignancy rate should be interpreted considering the significant heterogeneity and the inclusion of a high proportion of retrospective studies and populations from high-risk regions. Nonetheless, these findings offer essential evidence for clinical risk stratification, supporting optimized follow-up and informed decision-making.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Stapled versus hand-sewn intestinal anastomosis in pediatric surgery: A systematic review and meta-analysis.

BACKGROUND: Intestinal anastomosis is a core procedure in pediatric gastrointestinal surgery, performed for conditions such as necrotizing enterocolitis, intestinal atresia, Hirschsprung's disease, and inflammatory bowel disease. Although stapled anastomosis (SA) may improve operative efficiency, its safety and effectiveness compared with hand-sewn anastomosis (HA) in children remain uncertain. This meta-analysis compared clinical outcomes of SA and HA in pediatric patients. METHODS: The study followed PRISMA guidelines and was prospectively registered in PROSPERO (CRD420251177257). A systematic search of PubMed, Dimensions, and the Cochrane Library was conducted through June 2025. Studies including children under 7 years undergoing intestinal SA or HA were eligible. Two reviewers independently performed study selection, data extraction, and risk-of-bias assessment using ROB 2 and ROBINS-I tools. Statistical analysis was conducted using Comprehensive Meta-Analysis software (v3) with a random-effects model. RESULTS: Eleven studies involving 903 patients met inclusion criteria, including two randomized controlled trials. Of these, 333 patients underwent SA and 570 underwent HA. SA was associated with significantly shorter operative time (mean difference [MD] = -19.26 min; 95% CI: -24.24 to -14.28; p < 0.001) and earlier initiation of oral feeding (MD = -2.32 days; 95% CI: -3.78 to -0.86; p = 0.002). No significant differences were found in anastomotic leakage, stricture formation, reoperation rate, or length of hospital stay. CONCLUSIONS: Stapled anastomosis appears as safe as hand-sewn techniques in pediatric intestinal surgery while offering shorter operative duration and faster postoperative feeding recovery. Selective use of stapled techniques is supported when anatomically feasible, though further multicenter randomized trials are needed.

Humans

Interfacial engineering of cobalt tungstate-halloysite nanotube nanocomposite for electrochemical detection of synthetic vanillin in food matrices.

In processed foods and medicine, synthetic vanillin is widely used, although excessive intake poses toxicological risks. Due to the rising usage of synthetic vanillin in food products and associated health hazards, quick, sensitive, and reliable analytical methods are needed to precisely measure vanillin in complex food matrices. This work introduces a CoWO4@F-HNT/GCE nanocomposite as an efficient electrocatalytic modifier for glassy carbon electrodes aimed at trace-level synthetic vanillin detection. Structural and microscopic analyses confirmed phase-pure monoclinic CoWO4, preservation of the tubular aluminosilicate framework, and homogeneous nanoparticle anchoring on F-HNT. Differential pulse voltammetry provided a broad linear range from 0.01 to 372.14&#xa0;&#x3bc;M and a low detection limit of 4.3&#xa0;nM, together with excellent selectivity against common interferents, good cycling stability, and high inter-electrode reproducibility. These characteristics position the CoWO4@F-HNT-modified electrode as a cost-effective and reliable platform for on-site quality control of synthetic vanillin in complex food matrices.

Benzaldehydes

Morphology-engineered NiFe@C nanocages boosting electrochemical quantification of ractopamine in meat samples.

It is essential to acquire efficient electrocatalysts to develop ractopamine (RAC) electrochemical sensors. Herein, we report the synthesis of a series of carbon coated NiFe alloy nanostructures (e.g., NiFe@C nanoparticles, nanocubes and nanocages) using NiFe Prussian blue analogue (PBA) as the precursor. The NiFe@C nanocages exhibited the best electrocatalytic performance for RAC sensing. This is attributed to the embedded NiFe alloy nanoparticles that provide abundant active sites, and the unique nanocage structure facilitates electron transfer pathways while offering a high specific surface area. The resulting sensor achieves a low detection limit (LOD) of 54&#xa0;nM (S/N&#xa0;=&#xa0;3) within a linear range of 0.2-12&#xa0;&#x3bc;M. Moreover, the sensor demonstrates good reproducibility, stability, and excellent long-term stability. Practical applicability was confirmed in meat samples, yielding satisfactory recovery rates ranging from 98% to 108%. A feasible strategy was introduced herein for rational design of metal@carbon electrocatalysts.

Phenethylamines

Machine learning-assisted Mn-N-C nanozyme colorimetric sensor array for trace-level detection of biogenic amines in meat.

Accurate detection of biogenic amines (BAs) in meat remains challenging due to their high structural similarity and co-occurrence. Herein, an Mn-N-C nanozyme was synthesized via a metal-organic framework confined pyrolysis strategy, possessing excellent oxidase (OXD)- and peroxidase (POD)-like activities. The dual enzyme-like activity showed Km values of 0.1584&#xa0;mM (OXD) and 0.1498&#xa0;mM (POD), respectively, in detection system. Leveraging these properties, a colorimetric sensor array was constructed, enabling the detection of four representative BAs within a concentration range of 2-10&#xa0;ppm with 100% classification accuracy. In addition, a concentration independent recognition model based on an artificial neural network was developed to address signal nonlinearity interference in meat. The integrated system achieved accurate trace-level identification of BAs in perishable fish, pork, and chicken, demonstrating its applicability for early-stage BAs monitoring and quality deterioration warning during storage and transportation.

Biogenic Amines

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine&#x2011;hydrogen peroxide (TMB-H&#x2082;O&#x2082;) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82&#xa0;CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

PdIr bimetallic nanozyme engineered metal-organic frameworks integrated dual-mode sensor toward Stx2 detection in food.

Shiga toxin II (Stx2) has attracted extensive attention due to its toxicity and pathogenicity, making the development of sensitive detection methods urgent. This study constructed a dual-mode sensing platform for the sensitive detection of Stx2 in food. Composite material UIO-66@PdIr with peroxidase-like activity and fluorescent properties was synthesized and combined with cDNA as the signal probe, while aptamer-modified magnetic beads served as the capture probe. Specific binding of Stx2 to the aptamer triggered the release of the signal probe, enabling colorimetric and fluorescence signal readout. The colorimetric mode showed a linear range of 0.05-100&#xa0;ng/mL with an LOD of 0.039&#xa0;ng/mL, and the fluorescence mode exhibited 0.01-1000&#xa0;ng/mL with an LOD of 0.0097&#xa0;ng/mL. Additionally, this method was successfully applied to the detection of Stx2 in food, and the recovery rates were 94.33%&#xa0;&#x223c;&#xa0;102.20%. It indicated that the constructed sensor holds great practical potential for Stx2 detection.

Food Contamination

A MIL-88@Ru-based molecularly imprinted electrochemiluminescence sensor for highly selective and sensitive detection of enrofloxacin residues in animal-derived foods.

Using a metal-organic framework (MOF) - supported Ru(bpy)32+ (MIL-88@Ru) composite luminescent material, this study innovatively adopted electropolymerization to fabricate a molecularly imprinted polymer-based electrochemiluminescent (MIP-ECL) sensor for enrofloxacin (ENR) detection in animal-derived foods. Systematic investigation of the ECL luminescence and ENR's quenching mechanism confirmed that the sensor integrates ECL's high sensitivity and MIP's high specificity, enabling rapid and accurate recognition of ENR. Experimental results show a good linear response in the range of 1&#xa0;nmol/L-20&#xa0;&#x3bc;mol/L (R2&#xa0;=&#xa0;0.99), a limit of detection (LOD) as low as 0.28&#xa0;nmol/L, as well as excellent selectivity and stability. Recoveries of ENR in all investigated matrices ranged from 97.7% to 106.4%, confirming the reliability of the established method. This ECL-MIP coupling strategy provides a new technical approach and application references for the efficient detection of trace pollutants in food safety and environmental monitoring fields.

Enrofloxacin