Search PubMedSearch

SEARCH · Search PubMed

Results for “Ultrasound-assisted extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

429 records · Page 6Linked to original sources

Clinical applications of digital twin technology in In Vitro Fertilisation.

BACKGROUND: Digital twin technology, originating from aerospace and manufacturing industries, has emerged as a transformative tool in healthcare. In vitro fertilisation (IVF) faces persistent challenges including suboptimal embryo selection, unpredictable treatment outcomes, and limited personalisation of protocols. Despite advances in assisted reproductive technology, existing literature exhibits fragmentation: artificial intelligence applications in embryo selection, ovarian stimulation, and endometrial assessment have been developed independently without systematic integration into comprehensive treatment frameworks. Digital twin technology offers unprecedented opportunities to create virtual replicas of biological systems, enabling real-time monitoring, predictive modelling, and personalised treatment strategies. AIM: This narrative review aims to critically examine the current applications of digital twin technology in IVF, evaluate its potential benefits and limitations, synthesize existing evidence into an integrative conceptual model, and identify future directions for implementation in reproductive medicine. METHOD: A comprehensive narrative review was conducted using PubMed, Scopus, Web of Science, and IEEE Xplore databases. A narrative review approach was selected over systematic review to accommodate the heterogeneity of evidence types in this emerging field, including theoretical frameworks, simulation studies, and proof-of-concept implementations that would be excluded from systematic reviews. Search terms included "digital twin," "IVF," "in vitro fertilisation," "assisted reproductive technology," "embryo selection," and "predictive modelling." Studies published between 2015 and 2025 were included, focusing on original research articles, systematic reviews, and proof-of-concept studies describing digital twin applications in reproductive medicine. RESULTS: Digital twin technology in IVF demonstrates significant potential across multiple domains including embryo development simulation, ovarian response prediction, endometrial receptivity modelling, and personalised stimulation protocols. Current applications integrate artificial intelligence, machine learning algorithms, time-lapse imaging, and omics data to create comprehensive virtual models. Early evidence suggests improvements in embryo selection accuracy, ovarian response prediction, and treatment protocol optimization, though large-scale randomized controlled trials remain limited. Implementation challenges include data integration complexity, computational requirements, regulatory considerations, and validation requirements. CONCLUSION: Digital twin technology represents a paradigm shift in IVF practice, offering personalised, predictive, and precision medicine approaches. This review synthesizes existing evidence to propose an integrative conceptual model for digital twin implementation across the IVF treatment spectrum, identifies critical knowledge gaps, and establishes research priorities to advance clinical translation. Despite current limitations, continued advancement promises improved success rates and patient outcomes.

Humans

Double-Axis Maxillary Skeletal Expander Suggests Higher Expansion Efficiency in Early Activation: A Finite Element Analysis.

INTRODUCTION: Conventional single-axis maxillary skeletal expanders (MSE) have some drawbacks, such as limited control over maxillary expansion and possible asymmetric expansion between the anterior nasal spine (ANS) and posterior nasal spine (PNS). This report introduces a double-axis maxillary skeletal expander (DAMSE) concept to overcome these drawbacks and enhance the efficiency of maxillary skeletal expansion. MATERIALS AND METHODS: Five different DAMSE designs were compared with a conventional single-axis MSE. Finite element analysis was performed to analyse their expansion efficiency, stress magnitude and distribution occurring in a simplified bone model. RESULTS: DAMSE outperformed the single-axis MSE and provided better control over ANS and PNS expansion. During early activation, the highest expansion efficiency (31.7%) was achieved by DAMSE Model V, 13% more efficient than the single-axis MSE. This efficiency was increased to 100.8% by combining the DAMSE Model V with midpalatal suture surgery. However, with the simplified bone model, the current study could not demonstrate that DAMSE can resolve the issue of asymmetric expansion between ANS and PNS. CONCLUSIONS: An appropriately designed DAMSE can be a promising tool for maxillary expansion treatment. DAMSE offers more efficient treatment than the conventional single-axis MSE while maintaining similar levels of patient comfort and invasiveness.

Finite Element Analysis

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16 weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

[Pathogenicity analysis and prenatal genetic counseling for five Chinese pedigrees harboring a hemizygous c.-32C>G variant of FGF13 gene].

OBJECTIVE: To explore the pathogenicity and prenatal counseling strategies for five Chinese pedigrees harboring a hemizygous c.-32C>G (NM_001139500.2) variant of fibroblast growth factor 13 (FGF13) gene. METHODS: Five Chinese pedigrees found to carry a hemizygous c.-32C>G variant of the FGF13 gene at the Prenatal Diagnosis Center of Henan Provincial People's Hospital between January 2024 and January 2025 were selected as study subjects. The pedigrees had undergone prenatal diagnosis for a family history of genetic disorders, abnormal fetal ultrasound findings, or advanced maternal age. A retrospective analysis was carried out, wherein clinical data for all members of the pedigrees were obtained through the medical records system and outpatient visit system. Peripheral blood samples were collected from all pedigree members, and amniotic fluid samples were obtained from the probands. Following extraction of genomic DNA, prenatal diagnosis was performed using chromosomal microarray analysis (CMA) and trio whole-exome sequencing (trio-WES). Sanger sequencing was used to determine the carrier status for the candidate variant, and Mini-Mental State Examination (MMSE) was used to assess the cognitive function of hemizygous individuals carrying the FGF13 gene c.-32C>G variant. Pathogenicity of candidate variant was assessed based on guidelines from the American College of Medical Genetics and Genomics (ACMG). This study was approved by the Medical Ethics Committee of the hospital (Ethics No.: 2021-171). RESULTS: CMA and trio-WES revealed no pathogenic variants in all probands, whilst trio-WES and Sanger sequencing had identified 11 male individuals carrying a hemizygous c.-32C>G variant of the FGF13 gene from the five pedigrees, which included six adult males, a young boy, and four fetuses. One fetus had undergone termination of pregnancy due to hydrocephalus, one was born pre-term at 34+1 weeks of gestation owing to maternal hypertension, and other two were delivered at full term. Follow-up of the survived males revealed no phenotypic manifestations related to language or intellectual impairment. Among these, three adult males underwent the MMSE assessment, all of whom showed normal cognitive function. Search of the gnomAD database suggested the carrier frequency of FGF13 c.-32C>G variant in the East Asian population to be 0.125%, with 11 hemizygous males documented. Three male patients harboring the variant showed severe intellectual disability. Both in vitro and in vivo studies suggested that it could reduce the translation levels of FGF13 protein. Based on the ACMG guidelines, it was classified as variant of uncertain significance (BS4+PS3_Supporting). CONCLUSION: There is insufficient evidence to classify the FGF13 c.-32C>G as a pathogenic variant in clinical practice, and its presence should not be considered an indication for pregnancy termination due to major birth defects.

Adult

Beyond da Vinci: a systematic review of next-generation multiport robotic platforms in pediatric surgery.

As robotic surgery expands beyond the da Vinci platform, the relevance of new-generation systems to pediatric patients remains uncertain. This review examined the technical characteristics, applications, and perioperative outcomes of alternative multiport robotic platforms in children. PubMed/MEDLINE, Web of Science, Scopus, and the Cochrane Library were searched through 28 February 2026 in accordance with PRISMA 2020. Owing to clinical heterogeneity, findings were synthesized narratively, with Wilson 95% confidence intervals for key binary outcomes. Six studies reported 166 patients across 27 procedure types. Senhance accounted for 164 patients, while Hugo RAS and Hinotori were each represented by one patient. Ages ranged from 15 days to 17 years and weights from 3.8 to more than 100 kg. Senhance was the only platform used with 3-mm robotic instruments. Conversion or planned escalation occurred in 19 patients (11.4%; 95% CI, 7.5-17.2%). Four intraoperative complications were reported (2.4%; 95% CI, 0.9-6.0%). Across all reports, 20 patients experienced postoperative complications (12.0%; 95% CI, 7.9-17.9%). In the largest cohort, seven patients required reintervention (4.6%; 95% CI, 2.2-9.2%) and seven were readmitted (4.6%; 95% CI, 2.2-9.2%). No deaths or comparative pediatric studies were reported. Published experience remains sparse and is almost entirely limited to Senhance. Current evidence describes early clinical use without establishing comparative safety, effectiveness, or platform superiority. Prospective multicenter studies with standardized reporting are needed.

Humans

Reliability-aware hierarchical learning for Chagas disease screening from 12-lead ECGs: tackling label uncertainty and class imbalance.

Objective.Chagas disease, a neglected tropical disease (NTD) with significant cardiovascular impact, remains underdiagnosed in resource-limited regions. Electrocardiogram (ECG) screening offers a low-cost tool for detecting cardiac involvement, yet algorithm development is challenged by label noise, data scarcity, and the latent nature of infection. This study proposes a robust ECG-based screening framework that explicitly addresses these constraints.Approach.We introduce aReliability-Aware Hierarchical Learningstrategy that calibrates supervision according to data provenance, prioritizing serology-confirmed labels over noisy self-reports. To mitigate data scarcity, we compare a specialized convolutional neural network (CNN) trained from scratch with a transfer learning approach based on a Spatio-Temporal ECG foundation Model (FM). Performance is evaluated across varying data scales, and the representation structure is analyzed to interpret model behavior.Main results.On the official hidden test set of the George B. Moody PhysioNet/Computing in Cardiology Challenge 2025, our approach achieved a Challenge Score of 0.163. We observe that while the specialized CNN performs competitively in data-rich regimes, the FM exhibits superior robustness in extreme low-resource settings. Furthermore, performance reaches a plateau imposed by underlying disease physiology. Bimodal score distributions suggest that models distinguish established cardiomyopathy from indeterminate infection, which remains electrophysiologically indistinguishable from healthy controls.Significance.These findings clarify both the potential and intrinsic limits of ECG-based AI screening for NTD-associated cardiac involvement. Reliability-aware supervision and data-efficient transfer learning provide a practical framework toward scalable and clinically meaningful ECG screening systems in resource-constrained environments.

Humans

Alignment strategies in total knee arthroplasty and the patellofemoral joint: A systematic review.

BACKGROUND: Different alignment strategies in total knee arthroplasty (TKA) may affect the patellofemoral joint. Mechanical alignment (MA) is commonly used but may alter native anatomy. Newer strategies such as kinematic alignment (KA), restricted kinematic alignment (rKA), and functional alignment (FA) aim to better restore native joint mechanics. This study provides an overview of the effects of alignment strategies on patellofemoral outcomes after TKA. METHODS: A literature search in July 2025 identified studies comparing patellofemoral outcomes in TKA using different alignment strategies. Of 166 studies screened, eight met inclusion criteria. Three studies were considered medium quality and five studies low quality. RESULTS: KA and rKA more closely restored native trochlear morphology than MA and FA, reducing outliers in the anterior trochlear line compared with MA and FA. MA showed greater trochlear translation, suggesting worse patellar tracking. Trochlear angles were more anatomical in KA and rKA. However, KA was associated with increased internal femoral component rotation and more outliers beyond safe thresholds. FA showed more consistent rotational positioning, generally within safe limits. Lateral patellar shift and intraoperative lateral release rates did not differ significantly between KA and MA. Only one study reported patella-specific clinical outcome scores, finding no difference between FA and adjusted MA. CONCLUSION: KA and rKA better restore trochlear morphology, but risk excessive internal femoral component rotation. FA provides a more balanced approach. MA, while widely used, is linked to altered trochlear shape and worse patellar tracking. The clinical impact of these radiological differences remains unclear, and higher-quality studies are needed.

Humans

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

Routine methods misidentify Serratia spp.: Limitations of MALDI-TOF MS revealed by whole-genome sequencing.

Accurate species-level identification within the genus Serratia remains challenging due to extensive phenotypic overlap and high genomic relatedness among closely related and recently described taxa. This study presents an evaluation of routine and genome-based identification approaches applied to clinical Serratia isolates, integrating phenotypic assays, MALDI-TOF MS (Bruker Daltonics), 16S rRNA gene sequencing, and Whole-Genome Sequencing (WGS). A total of 103 isolates collected from a teaching hospital were analyzed. WGS was performed on a subset of isolates. Conventional biochemical methods classified all isolates as Serratia marcescens, whereas MALDI-TOF MS identified 60.1% as S. marcescens, 11.6% as S. ureilytica, and 28.1% just at the genus level. Peak analysis from MALDI-TOF MS revealed specific peaks associated with S. marcescens and S. ureilytica, but limited discriminatory power. WGS of six isolates initially identified as S. ureilytica by MALDI-TOF MS revealed reclassification as Serratia sarumanii (n = 5) and Serratia montpellierensis (n = 1), supported by Average Nucleotide Identity (ANI), Average Amino Acid Identity (AAI), and Digital DNA-DNA Hybridization (dDDH) thresholds. In contrast, 16S rRNA analysis showed limited species-level resolution. Phylogenomic and SNP-based analyses confirmed these classifications with strong support. Overall, this study underscores the critical role of high-resolution genomic approaches for precise species identification and highlights the need for continuous expansion and curation of MALDI-TOF MS reference databases to support reliable clinical diagnostics and epidemiological surveillance of emerging Serratia species.

Spectrometry, Mass, Matrix-Assisted Laser Desorpti

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

Robust optimisation for photon radiotherapy: A scoping review of models, paradigms, and reporting.

BACKGROUND AND PURPOSE: Robust optimisation offers an alternative to conventional margin-based photon radiotherapy planning by explicitly modelling uncertainty, but practice is variable and not standardised. MATERIALS AND METHODS: A scoping review was conducted to map robust optimisation for photon external beam radiotherapy. Electronic searches of Scopus, PubMed and Google Scholar (2000-2025, English language) identified planning studies that incorporated modelled uncertainties into the optimisation process and reported at least one robustness-related outcome. Data were charted on clinical context, uncertainty models, optimisation paradigms, robustness metrics and evidence for clinical implementation. RESULTS: Seventy-one studies were included. Most investigated prostate, breast or lung cancer and used intensity-modulated radiotherapy or volumetric-modulated arc therapy in commercial or research treatment planning systems. Scenario-based worst-case (minimax) optimisation was the dominant paradigm in clinically oriented work, while chance-constrained, conditional value at-risk, distributionally robust and adaptive formulations were confined to small methodological series. Uncertainty modelling focused mainly on rigid set-up error; fewer studies incorporated respiratory motion, inter-fraction anatomical change, dose-calculation uncertainty or biological variation. Robustness was evaluated with diverse scenario-based dose-volume metrics, probabilistic coverage measures, composite robustness indices and, less often, biological endpoints. Direct clinical implementation reports were scarce. CONCLUSION: Robust photon planning is technically feasible and generally maintains or improves target coverage and organ sparing compared with margin-based planning. However, heterogeneity in uncertainty models, optimisation configuration and robustness reporting limits comparison and synthesis. Pragmatic minimum standards are proposed to support future consensus and wider clinical adoption.

Humans

Artificial intelligence enabled social robotic interventions (PARO) in Australian dementia care: A systematic review and meta-analysis.

BACKGROUND: Although there is a growing body of research indicating that Personal Robot/Social Robot could be used in various aspects of care for individuals with dementia, little is known about how well these types of interventions work in an actual hospital setting in Australia. AIMS & OBJECTIVES: The objective of the present systematic review and meta-analysis is to assess the effectiveness of PARO-based socially assistive robotic intervention in terms of its effectiveness outcomes towards the reduction of dementia-related behavioural and psychological symptoms in Australian based healthcare settings. METHODS: A systematic search was conducted across five electronic databases, including MEDLINE (PubMed), EMBASE, CINAHL, PsycINFO, and the Cochrane Library, to identify randomised controlled trials (RCTs) investigating PARO-based socially assistive robotic interventions for dementia in Australian healthcare settings. This review was registered with PROSPERO (CRD420251251916) and followed the PRISMA 2020 guidelines. In addition, the Cochrane Risk of Bias tool (RoB 2) was used to evaluate the risk of bias across all studies. Pooled standardised mean differences (SMD) with 95&#xa0;% confidence intervals (CI) were calculated for agitation, anxiety, and depression. Heterogeneity across studies was evaluated using the I2 statistic. RESULTS: Six RCTs involving 1444 participants were identified for inclusion in this review. AI-enabled socially assistive robotic interventions, specifically the PARO therapeutic robot, significantly reduced agitation and anxiety when compared to standard treatment or control conditions. The pooled analysis showed that agitation [SMD&#xa0;=&#xa0;-0.44 (95&#xa0;% CI: -0.70, -0.18) p&#xa0;=&#xa0;0.0008] and anxiety [SMD&#xa0;=&#xa0;-0.59 (95&#xa0;% CI: -0.91, -0.27) p&#xa0;=&#xa0;0.0003] were reduced significantly, while the decrease in depression [SMD&#xa0;=&#xa0;-0.44 (95&#xa0;% CI: -0.95, -0.07) p&#xa0;=&#xa0;0.09] scores was non-significant among dementia patients receiving PARO-based socially assistive robotic interventions as compared to the control. The overall risk of bias across all six studies was considered low to moderate. CONCLUSION: PARO-based socially assistive robotic interventions may provide preliminary evidence of effectiveness in reducing agitation and anxiety in individuals with dementia in Australian healthcare, but the evidence regarding the reduction of depression remains unclear. Therefore, additional high-quality trials with consistent methodology and extended follow-up will be necessary to determine both the short-term and long-term clinical efficacy and practicality of implementing these interventions into practice.

Humans

Initial 4-Year Experience With Microaxial Flow Pumps Within a Tertiary Centre in Regional Australia.

BACKGROUND & AIM: The Microaxial Flow Pump (MFP) is a miniaturised rotary pump that aspirates blood from the left ventricle and expels it into the ascending aorta. It unloads the left ventricle and increases mean arterial pressure and cardiac output. MFP is most commonly utilised in cardiogenic shock, for protected percutaneous coronary intervention (PCI), and for ventricular offloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO). METHOD: We conducted a retrospective review of all patients who underwent MFP insertion at John Hunter Hospital, Australia. Categorical data are represented as counts and percentages, with continuous variables described as means with standard deviations. RESULTS: Twenty-three MFP devices were inserted between September 2020 and May 2024. Five (22%) were for protected PCI, three (13%) for venting with VA-ECMO (ECPELLA), and 15 (65%) for acute coronary syndrome (ACS) and cardiogenic shock. The median age for the overall cohort was 62 years, with a 74% male predominance. Eighty percent of the protected PCI cohort were elective outpatient procedures, and there were no deaths in this cohort. The mortality in the ECPELLA group was 67%. Thirteen (87%) of the patients with cardiogenic shock presented with an anterior infarct, and 53% had cardiac arrest on admission. The overall morality in the cardiogenic shock cohort was 40%. Complications in this cohort included limb ischaemia in four patients (17%) and site bleeding in seven patients (30%). Four patients (17%) required vascular surgery intervention. CONCLUSION: Our initial experience showed the use of MFP in a tertiary centre was safe and feasible, allowing progression from protected percutaneous intervention to acute cardiogenic shock.

Humans

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation

Efficacy and Safety of Mechanical Insufflation-Exsufflation in Invasively Ventilated Critically Ill Adults: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Mechanical insufflation-exsufflation (MI-E) is increasingly used in invasively ventilated adults in the intensive care unit (ICU), yet its therapeutic efficacy and safety remain uncertain due to inconsistent evidence. AIM: To synthesize evidence on the clinical efficacy and safety of MI-E in this population and to examine methodological and clinical heterogeneity underlying reported outcomes. STUDY DESIGN: A systematic review and meta-analysis of randomized studies (including RCTs and randomized crossover trials), conducted following PRISMA guidelines, with risk of bias assessed using the Cochrane risk-of-bias tool. RESULTS: Five randomized controlled trials involving 310 patients were included. Meta-analysis showed that mechanical insufflation-exsufflation (MI-E) significantly increased sputum clearance (SMD&#x2009;=&#x2009;0.63, 95% CI, 0.32-0.93; p&#x2009;<&#x2009;0.00011; I2&#x2009;=&#x2009;38%) without affecting oxygenation (MD&#x2009;=&#x2009;0.28, 95% CI, -0.53 to 1.09; p&#x2009;=&#x2009;0.50; I2&#x2009;=&#x2009;9%). Data on respiratory mechanics, ventilation duration and ICU stay could not be pooled. No serious adverse events were reported. CONCLUSIONS: MI-E significantly improves sputum clearance in invasively ventilated critically ill adults, with no severe adverse events reported in the included studies. Its effects on other outcomes remain inconclusive due to limited data and heterogeneity. Standardized protocols and larger trials are needed. RELEVANCE TO CLINICAL PRACTICE: Clinicians may consider MI-E as an adjunct for respiratory secretion management. Application should be guided by structured patient assessment and individualized parameter adjustment. Future research should standardize interventions and target well-defined patient subgroups to inform clear practice guidelines. TRIAL REGISTRATION: The review protocol was registered in the International Prospective Register of Systematic Reviews, with registration number CRD42023403299.

Humans

Post-intervention effectiveness of a computerized personalized cognitive stimulation program adapted according to cognitive reserve in older adults without cognitive impairment in Primary Care: A randomized clinical trial.

BACKGROUND: Cognitive reserve may influence responsiveness to cognitive interventions, yet it is rarely used to tailor computerized stimulation. OBJECTIVE: To evaluate the effectiveness of a computerized cognitive stimulation program personalized according to cognitive reserve on cognition, reserve-related activities, and digital competence in community-dwelling older adults without cognitive impairment in Primary Care. METHODS: In this randomized clinical trial, 102 adults aged &#x2265;65 years with normal cognitive performance were recruited from three primary care centers in Zaragoza, Spain, and stratified by cognitive reserve level before random allocation to intervention or control. The intervention comprised digital literacy sessions followed by 8 weeks of home-based computerized cognitive stimulation tailored to participants' cognitive reserve profiles and life history. Controls received a single group-based health education session focused on maintaining everyday cognitive activity. Outcomes were assessed at baseline and post-intervention using global cognition (MEC-35), the Cognitive Reserve Questionnaire, the Mobile Device Proficiency Questionnaire-16, and domain-specific neuropsychological tests. A total of 100 participants completed the final evaluation and were included in complete-case analyses. RESULTS: Compared with controls, the intervention group showed greater adjusted post-intervention improvements in global cognition (MEC-35 between-group difference: 1.8 points) and several cognitive measures, including temporal orientation, calculation, attention, praxis, verbal fluency, processing speed, executive functions, and verbal learning. CRQ scores and digital competence also improved, with small-to-large effect sizes. CONCLUSIONS: A computerized cognitive stimulation program adapted according to cognitive reserve appears feasible in Primary Care and may improve cognition, engagement in reserve-related activities, and digital competence in older adults without cognitive impairment.

Humans

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

One Year After a Cyberattack: Lessons Learned and Dosimetric Analysis of Contingency Radiotherapy Plans.

PURPOSE: Cyberattacks on health care institutions pose significant risks to patient care, particularly in radiotherapy departments, which are heavily reliant on digital systems. This study examines the impact of a ransomware attack on our hospital and evaluates the effectiveness of the contingency measures implemented to resume radiotherapy treatments. METHODS AND MATERIALS: Following the cyberattack, our radiotherapy department faced a complete shutdown. After an initial estimate considering a shutdown of several weeks, a contingency plan was executed, including manual patient data retrieval and collaboration with a backup hospital. Contingency plans were prepared and delivered within hours, despite a partial lack of information. These plans allowed some patients to restart treatment 3 days after the attack. A dosimetric analysis was performed for the contingency plans, including various pathologies, mainly glioblastoma, head and neck cancers, and lung cancer. We compared the original and contingency plans in terms of dose coverage to the clinical target volume, biological effective dose, and their clinical impact as assessed at the 1&#x2011;year follow&#x2011;up after the cyberattack. RESULTS: Treatments resumed within 12 days at our hospital. Patients with glioblastoma showed good target coverage because of generous margins, resulting in favorable outcomes. In head and neck cases, the lack of detailed imaging led to significant target volume misses, suggesting that more conservative initial treatments could have been beneficial. Lung cases demonstrated accurate peripheral lesion targeting but faced challenges in central lesions because of the absence of positron emission tomography information. In most cases, the approach of using a contingency plan, even with limited information, led to a higher biological effective dose than would have been achieved if treatment had been stopped until full recovery at our hospital. CONCLUSIONS: The study highlights the critical importance of robust contingency planning in radiotherapy departments, emphasizing the need for backup systems and tailored approaches based on tumor location and available diagnostic information. These lessons emphasize that preparedness for digital disruptions should not focus exclusively on information and technology infrastructure.

Humans