Search PubMedSearch

SEARCH · Search PubMed

Results for “Antibiotic sensitivity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

399 records · Page 6Linked to original sources

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Accelerated Diagnostic Pathways for Suspected Acute Coronary Syndrome in Practice: A Randomized Trial of 0/1-Hour vs 0/3-Hour Troponin Testing.

BACKGROUND: For suspected acute coronary syndrome (ACS), guidelines recommend using high-sensitivity troponins (hs-cTn) in accelerated diagnostic pathways (ADPs) with 0/1-hour recommended over 0/3-hour ADP. However, implementation of these ADPs, with universal use of hs-cTns, has not been directly compared in randomized trials OBJECTIVES: This study sought to compare the efficiency and safety of the European Society of Cardiology (ESC) 0/1-hour and a 0/3-hour ADP when implemented in real-world clinical practice. METHODS: This pragmatic, randomized, noninferiority implementation trial compared the safety and efficiency of clinician decision making using these 2 pathways. To prevent incorporation bias, an independent hs-cTnI was used for formal adjudication using the fourth universal definition of myocardial infarction (MI). Efficiency was judged by the proportion of patients discharged within 4 hours. The safety endpoint was major adverse cardiac events (MACE) within 30 days (adjudicated index or representation type 1 MI, cardiovascular death, and urgent coronary revascularization) for those who were considered not to have ACS and discharged. The noninferiority margin, for absolute difference in sensitivity, between the ESC 0/1-hour and the 0/3-hour ADP was set at 3%, assessed with a 1-sided 97.5% CI. RESULTS: From December 2021 to July 2024, of 13,983 screened 3,543 individual patients with suspected ACS were recruited and consented from 2 major emergency departments in North-West England, with 100% follow-up achieved for all representations to any national hospital. The median age was 60 years (IQR: 49.5-70.5 years), 53% were men, 6.7%, and 7.6% had adjudicated index type 1 MI and MACE within 30 days, respectively. The turnaround time from sample to result for central laboratory hs-cTnT was 81 minutes (IQR: 69-101 minutes). The proportion of patients discharged within 4 hours was relatively low and did not differ substantially (21.8% vs 19.2%, P = 0.07). In addition, the 0/1-hour pathway was noninferior for safety, in patients discharged, compared with the 0/3-hour pathway, absolute difference in sensitivity was +4.2% (1-sided 97.5% CI: -2.5) in favor of the 0/1-hour pathway. The calculated sensitivities were 93.7% (95% CI: 88.4%-97.1%) vs 89.5% (95% CI: 82.7%-94.3%), respectively. CONCLUSIONS: Implementation of the ESC 0/1-hour pathway failed to discharge significantly more patients within 4 hours of presentation compared with the 0/3-hour ADP. In addition, The ESC 0/1-hour was noninferior to the 0/3-hour hs-cTn pathway for safety of discharge, although safety for both pathways was less than that imputed by observational studies. This trial demonstrates that perceived benefits to emergency department efficiency of a reduced sampling interval are mitigated by central laboratory turnaround times as well as system constraints. (Pragmatic Randomised Trial of the ESC 0/​1 Versus 0/​3 Hour Troponin Pathway [MACROS2]; NCT05322395).

Acute Coronary Syndrome

Emergence of a Novel, Phenotypically Difficult-to-Detect Vancomycin-Resistant Enterococcus faecium Clone (ST117/CT7799).

A significant increase of vancomycin-resistant Enterococcus faecium (VREfm) infections was observed in South-Eastern Austria since 2024. The prolonged outbreak is caused by a novel vanB-VREfm clone (ST117/CT7799, "VREfmstyr"). This study characterizes the atypical difficult-to-detect resistance phenotype and assesses the genomic relatedness of the isolates. Patient and outbreak characteristics were investigated including whole genome sequencing of the isolates. Sensitivity of broth microdilution (BMD), gradient tests (GT), disk diffusion (DD), and automated susceptibility testing (VITEK2) was compared. The performance of commercial screening media was evaluated. From sporadic detections in early 2024 case numbers began to rise during the year. In 30/31 (97%) of all cases, intra-hospital transmission was considered likely and an association with invasive procedures was identified in most cases. Core genome multilocus sequence typing revealed only six allelic differences between VREfmstyr isolates collected in a 12-month period, all belonging to the E. faecium ST117/CT7799 lineage. BMD detected vancomycin resistance (MIC > 4 mg/L) in no more than 16/31 (52%) of isolates after 24 h incubation, while GT and DD misclassified all isolates. Only prolonged incubation improved the performance of these assays. VITEK2 analysis, however, correctly classified all 31 isolates. Of four commercially available VRE-screening agars, only one was capable of detecting VREfmstyr after 24 h incubation. The emergence and clonal dissemination of VREfm ST117/CT7799 reveals a serious diagnostic gap as commonly used diagnostic algorithms fail to reliably detect this resistance phenotype. Our findings should help to further evaluate the true geographical distribution and clinical significance of this novel VREfm clone.

Enterococcus faecium

Comparison of conventional and micro-surgical techniques for gingival recession using collagen matrix: Randomised controlled split-mouth clinical trial.

BACKGROUND: The present study aimed to determine the effectiveness of the microsurgical approach in treating gingival recession with collagen matrix by comparing it with Conventional surgery in terms of clinical and patient-centered outcomes. METHODS: A total of 29 patients with bilateral gingival recession in the maxillary canine and/or premolar region were selected. After randomisation, bilateral recession sites were grouped into the test group (Microsurgery under 3.5 X magnification) and the control group (Conventional surgery). All the clinical and patient-reported parameters were recorded at baseline, 1, 3 and 6 months. RESULTS: Both groups showed statistically significant differences in terms of reduction in gingival recession height (GRH), gingival recession width (GRW), clinical attachment level gain (CAL gain), increase in keratinized tissue thickness (KTT) and keratinized tissue width (KTW) after 6 months. But intergroup comparison showed no significant difference in terms of clinical parameters. The only significant difference was noted in terms of patient-centred parameters (Patient satisfactory score, Hypersensitivity score, Root aesthetic scores), which favoured the microsurgical group. CONCLUSIONS: Both groups demonstrated comparable clinical improvement; However, Patient-centred parameters were significantly better with the Microsurgical approach. Selection of the surgical approach should balance patient needs with practical considerations like cost, time, and clinician proficiency.

Adult

AI-driven snapshot hyperspectral imaging for on-line sorting systems in food industry: From real-time sensing to intelligent decision-making.

High-throughput food sorting requires rapid, non-destructive detection of external defects, foreign materials, and internal quality attributes in heterogeneous food matrices. Conventional scanning hyperspectral imaging may suffer from motion-induced spatial-spectral mismatches, whereas snapshot hyperspectral imaging (S-HSI) captures spectral images within a single integration time. However, its advantage is limited by trade-offs in resolution, signal-to-noise ratio (SNR), reconstruction uncertainty, and calibration stability, which are further amplified by variable tissue structure, surface reflection, moisture, and fat distribution in foods. This review critically examines artificial intelligence (AI)-driven S-HSI for on-line food sorting within a sensing-representation-decision-execution framework. Compact architectures are compared according to their physical constraints, food-sorting suitability, and ability to support mapping between spectral responses and physicochemical quality attributes. AI strategies are reviewed for spectral reconstruction, image restoration, spatial-spectral representation, band selection, uncertainty-aware decision-making, and edge implementation. AI can partially compensate for snapshot-specific limitations, but current evidence remains largely limited to laboratory or prototype studies. Future work should link system performance to food safety and quality outcomes by reporting throughput, decision latency, calibration drift, missed-detection risk, false-rejection cost, and closed-loop sorting success.

Hyperspectral Imaging

Impact of subthreshold troponin levels and temporal trends on short term adverse cardiovascular outcomes in patients discharged from the emergency department: a RACE-IT trial substudy.

BACKGROUND: High-sensitivity cardiac troponin I assays enable early exclusion of myocardial infarction in the emergency department. However, the clinical implications of detectable troponin values below the 99th percentile upper reference limit (4-18 ng/L) remain unclear. OBJECTIVE: To assess the association between subthreshold troponin levels and 30-day outcomes in patients from the RACE-IT trial, using exact troponin values when available. METHODS: This post-hoc analysis of the RACE-IT stepped-wedge randomized controlled trial included patients with troponin ≤ 18 ng/L across nine EDs. Patients were stratified by initial troponin, peak value, absolute change, and percent change. The primary outcome was a 30-day composite of all-cause death, acute MI, percutaneous coronary intervention, and coronary artery bypass grafting. Logistic regression analysis after adjusting for age, sex, race, and coronary artery disease was performed. RESULTS: Among 19,194 patients with troponin ≤ 18 ng/L, 117 (0.6%) experienced the composite outcome. Higher troponin levels were associated with increased event rates in unadjusted analyses. Adjusted analyses showed no independent associations overall, though patients whose highest troponin values fell within the ≥ 11- ≤ 18 ng/L range continued to demonstrate significantly worse outcomes than those with lower peak levels. Elevated troponin values correlated with older age, male sex, and greater comorbidity burden. CONCLUSION: In this post-hoc analysis of patients with troponin values below the 99th percentile URL, absolute levels and temporal changes were not independently associated with 30-day adverse outcomes. These findings support the use of subthreshold troponin values in rapid rule-out protocols, emphasizing the need to consider clinical context and comorbidities in risk assessment.

Humans

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans

Emergence of an optrA-positive Enterococcus faecalis ST699 lineage in animal-derived foods in Beijing, China.

Enterococci from animal-derived foods are key reservoirs for antimicrobial resistance (AMR) in the food chain. However, comparative genomic studies investigating the distribution of the oxazolidinone resistance gene optrA among food- and human-derived Enterococci remain limited. This study assessed linezolid-resistant Enterococci from retail meat and healthy humans in Beijing, China (2023-2024). Among 87 isolates, E. faecalis and E. faecium predominated. Food-derived isolates showed broader resistance profiles than human isolates. Fourteen optrA-positive strains were identified, accounting for 92.9% of food isolates. optrA frequently co-localized with erm(A), ant(9)-Ia, and fexA on Tn554-family transposons, suggesting a potentially transferable multidrug resistance module. Notably, an optrA-positive E. faecalis ST699 clone was identified for the first time in Chinese retail meat. This clone formed a distinct lineage and carried a complete Tn554-optrA island. A representative ST699 isolate exhibited enhanced fitness and virulence potential in the Galleria mellonella model. These findings highlight animal-derived foods as important reservoirs of linezolid-resistant Enterococci and provide genomic evidence consistent with their role as potential sources of optrA-mediated resistance. The emergence of a multidrug-resistant E. faecalis ST699 clone with enhanced fitness characteristics underscores the need for continued surveillance of foodborne antimicrobial resistance within the One Health framework.

Enterococcus faecalis

In Vitro comparison of herbal and conventional antifungals against Candida strains in Oral candidiasis: A systematic review and meta-analysis.

OBJECTIVE: This study aimed to systematically review and meta-analyze the in vitro antifungal activity of herbal and conventional antifungals against Candida strains. DESIGN: In vitro studies were identified through PubMed, Embase, Scopus, and Web of Science up until May 2026. This review is registered with Prospero (CRD420251128404). Eligibility was determined using the Population, Intervention, Comparison, and Outcome (PICO) framework, with specific inclusion and exclusion criteria focused on in vitro antifungal investigations comparing herbal antifungals with conventional antifungals. The risk of bias was assessed using the modified Quality Assessment Tool for In Vitro Studies (QUIN Tool). A meta-analysis was performed, with the primary outcome measure being the ratio of means (RoM). RESULTS: The systematic review included twenty-five articles. Most studies showed different results in inhibition zones or minimum inhibitory concentrations between herbal and conventional agents. The meta-analysis indicates that certain herbal antifungals are equally effective as or more effective than conventional antifungals against Candida dubliniensis, Candida lusitaniae, and Candida tropicalis. While the efficacy of herbal antifungals for Candida albicans and Candida glabrata was modest, Piper betle L. demonstrated significant inhibitory potential. In contrast, conventional antifungals outperformed herbal antifungals against Candida krusei and Candida parapsilosis. CONCLUSIONS: This systematic review and meta-analysis highlight herbal medicine as a potential antifungal therapy for oral candidiasis, emphasizing the need for new strategies due to resistance to conventional antifungals.

Humans

A mechanism-guided framework for prioritizing membrane-interaction anti-Vibrio peptides from peptidomics data.

A mechanism-guided framework for prioritizing membrane-interaction antimicrobial peptide candidates from proteomics-derived peptide mixtures is presented. The framework integrates conservative machine-learning-based antimicrobial peptide (AMP) screening with a literature-derived membrane-interaction plausibility (MAP) assessment and a data-driven membrane-interaction ranking function (AIPx), followed by structural visualization for interpretability. MAP encodes physicochemical characteristics commonly associated with peptide-membrane interaction and provides a graded plausibility assessment. Building upon this physicochemically interpretable framework, AIPx ranks peptides using feature weights calibrated from experimentally characterized anti-Vibrio peptides, where minimum inhibitory concentration (MIC) values are used as a coarse-grained ranking reference rather than a direct prediction target. In a peptidomics-based peptide fractionation study targeting Vibrio spp., AIPx exhibited a consistent relationship with experimentally observed antibacterial activity. Distributional analysis revealed that peptide fractions exhibiting high anti-Vibrio activity are characterized by enrichment of high-ranking peptides rather than by AMP abundance alone. By structuring AMP identification and prioritization as sequential stages, the MAP&#xa0;+&#xa0;AIPx framework enables interpretable and experimentally actionable candidate selection by reducing biologically implausible candidates. The framework facilitates species-oriented prioritization of AMP candidates, addressing a key challenge in antimicrobial peptide discovery where activity may depend on target-specific membrane characteristics. Moreover, the approach is extensible through species-specific calibration and supports interpretable, mechanism-informed prioritization in antimicrobial peptide discovery.

Proteomics

Tigecycline-resistant Staphylococcus in waiting pens of a pig slaughterhouse: genomic insights into a food safety alert.

BACKGROUND: The waiting pens of slaughterhouses represent a critical control point in the 'farm-to-fork' continuum, yet their role in the emergence and dissemination of antimicrobial resistance remains understudied. This study investigated tigecycline-resistant Staphylococcus (TRS) in these high-risk zones to assess their prevalence, resistance mechanisms, and transmission dynamics. METHODS: 400 samples were collected from the waiting pens of a pig slaughterhouse in Guangzhou, China. Antimicrobial susceptibility testing, whole-genome sequencing, phylogenetic analysis, and molecular cloning were employed to characterize resistance mechanisms and transmission patterns. RESULTS: 78 TRS strains were isolated and classified into three species, including S. borealis, S. ureilyticus, and S. pasteuri. These isolates exhibited multidrug-resistant phenotypes and carried new mutations in rpsJ and tet(M), which were functionally confirmed to reduce tigecycline susceptibility. Phylogenetic evidence demonstrated clonal transmission between pig farms and the slaughterhouse. The tet(M) gene was located within Staphylococcal cassette chromosome mec elements mediated by IS257, while tet(L) was carried by plasmids formed through IS256/IS257-mediated recombination. CONCLUSIONS: Waiting pens serve as crucial reservoirs for the amplification and dissemination of antimicrobial resistance. Our findings underscore the urgent need for enhanced biosecurity measures, improved waste management, and routine molecular surveillance in these high-risk zones to mitigate the spread of resistance along the food production chain.

Animals

Efficacy of the NMIC-150 system in identifying extended-spectrum beta-lactamases in clinical isolates.

Extended-spectrum beta-lactamases (ESBLs) are significant contributors to the growing global crisis of antimicrobial resistance. This study evaluated the performance of the NMIC-150 System for susceptibility testing of third-generation cephalosporins (3GCs) and assessed whether ceftazidime-avibactam and aztreonam-avibactam could identify ESBL-producing carbapenem-resistant Enterobacterales (CREs). A total of 278 non-duplicate clinical isolates (Klebsiella pneumoniae, E. coli, and Proteus mirabilis) were analyzed. Antimicrobial susceptibility was determined using reference broth microdilution (BMD) and the NMIC-150 System. ESBL production was defined as an &#x2265;eight-fold reduction in the minimum inhibitory concentration (MIC) of 3GCs in the presence of clavulanic acid, according to CLSI criteria. Whole-genome sequencing was performed to characterize ESBL and carbapenemase genes among 3GC-resistant isolates. A Random Forest model was used to predict ESBL-producing isolates based on MIC values. The NMIC-150 System demonstrated over 90% categorical and essential agreement with BMD for ceftazidime and ceftriaxone, along with robust predictive performance via Random Forest analysis. These findings suggest that the NMIC-150 System is a reliable platform for 3GC susceptibility testing and that an &#x2265;eight-fold MIC reduction with ceftazidime-avibactam or aztreonam-avibactam may serve as a phenotypic indicator of ESBL production in CRE isolates. In conclusion, the NMIC-150 System shows potential for routine antimicrobial resistance surveillance and may facilitate the rapid identification of ESBL-producing CREs in clinical settings.

Microbial Sensitivity Tests

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

Cost-effectiveness analysis of omeprazole for preventing esophageal stricture in patients with Zargar grade 2b and 3a corrosive esophageal injuries: A trial-based economic evaluation.

BACKGROUND: Corrosive esophageal injury frequently results in esophageal stricture requiring repeated endoscopic dilatation and substantial healthcare expenditure. This study evaluated the cost-effectiveness of omeprazole plus standard treatment compared with standard treatment alone for preventing esophageal stricture in adult patients with Zargar grade 2b and 3a corrosive esophageal injuries. METHODS: A trial-based economic evaluation was conducted alongside a randomized controlled trial from the healthcare provider and patient perspectives. Twenty patients were randomized to receive either standard treatment alone (n&#x2005;=&#x2005;10) or standard treatment plus omeprazole (n&#x2005;=&#x2005;10). Direct medical costs were analyzed using the incremental cost-effectiveness ratio. Deterministic one-way sensitivity analysis and probabilistic sensitivity analysis using Monte Carlo simulation were performed. RESULTS: The incidence of corrosive esophageal stricture was 20% (2/10) in the omeprazole group and 70% (7/10) in the standard treatment group (relative risk, 0.29; 95% confidence interval, 0.08-1.05; Fisher's exact test, P&#x2005;=&#x2005;.070). Omeprazole plus standard treatment reduced healthcare costs by THB 4642.30 per patient from the provider perspective and THB 5476.60 per patient from the patient perspective. The intervention remained the dominant strategy across all deterministic sensitivity analyses. Probabilistic sensitivity analysis demonstrated that 68.3% and 78.8% of simulations favored omeprazole from the provider and patient perspectives, respectively. CONCLUSION: Omeprazole plus standard treatment may represent a cost-effective strategy for adult patients with Zargar grade 2b and 3a corrosive esophageal injuries. However, these findings should be considered preliminary and require confirmation in larger multicenter randomized controlled trials.

Humans

Evaluation of one-step amplicon-based targeted enrichment for SARS-CoV-2 whole-genome sequencing using the Midnight amplicon scheme.

Genomic surveillance proved invaluable during the COVID-19 pandemic for tracking SARS-CoV-2 variants and guiding outbreak responses, underscoring the ongoing need to reduce whole-genome sequencing (WGS) costs and improve workflow efficiency to ensure accessibility in resource limited settings. Here, we evaluated a one-step reverse transcription polymerase chain reaction (RT-PCR) approach using the Midnight V2 primer scheme for targeted amplification of the SARS-CoV-2 genome, assessed its compatibility with Illumina sequencing, and compared its performance to a well-established two-step method. Initially, we determined optimal RT-PCR reaction conditions using the Midnight V2 primer panel for the one-step RT-PCR kit and scaled reaction volumes for both RT-PCR and library preparation. Clinical specimens (n&#x202f;=&#x202f;53) that had undergone routine WGS for surveillance purposes using the established two-step RT-PCR method were compared using the one-step RT-PCR assay. For samples with genome completeness greater than 70%, both methods gave comparable results with similar sequence coverage and 100% concordance for lineage assignment. Further investigation revealed a higher percentage of reads aligning to the SARS-CoV-2 genome with a greater depth of coverage using the one-step method compared to the two-step method. Finally, analysis of scaled one-step and library reaction volumes revealed significant cost savings for samples undergoing WGS. Overall, the results presented here verify the accuracy and reproducibility of one-step targeted amplification and offer an efficient and cost-effective workflow for routine SARS-CoV-2 genomic surveillance.

Humans

Artificial intelligence-supported double reading in European population breast cancer screening: A systematic review and meta-analysis of prospective programs.

BACKGROUND: Most European population mammography screening programs rely on double reading with arbitration, a model that delivers mortality benefit but is increasingly challenged by radiologist workload, variable specificity, and interval cancers. Artificial intelligence (AI) is being evaluated to support or optimize these established European screening pathways. PURPOSE: To synthesize prospective or program-embedded evaluations of AI conducted within European-style population screening programs and to estimate exploratory program-level absolute risk differences (RDs) per 1000 examinations for cancer detection rate (CDR) and recall. MATERIALS AND METHODS: We performed a prespecified, focused evidence synthesis of three large studies embedded within routine population screening programs operating under European-relevant workflows: MASAI (randomized AI-supported risk triage within a national program), ScreenTrustCAD (prospective paired-reader evaluation with AI as an independent reader in a double-reading framework), and PRAIM (nationwide decision-referral implementation). Outcomes were harmonized as AI-control RDs per 1000 examinations. Random-effects pooling used Hartung-Knapp-Sidik-Jonkman models. For the paired-reader design, sensitivity analyses applied a Kish effective sample-size approach across plausible within-examination correlations (&#x3c1;&#xa0;=&#xa0;0.3-0.8). Positive predictive value (PPV) and workflow/time outcomes were summarized descriptively. RESULTS: Across 597,419 examinations, the pooled CDR RD was +0.9 per 1000 (95% CI -0.0 to +1.8; I2&#xa0;&#x2248;&#xa0;12%), consistent with a modest directional increase with borderline statistical uncertainty. The pooled recall RD was -0.6 per 1000 (95% CI -3.1 to +2.1; I2&#xa0;&#x2248;&#xa0;41-43%), indicating no consistent recall increase across screening programs. Where reported, PPV was higher with AI-supported screening. Efficiency signals included 44.3% fewer total readings in MASAI and shorter reading times for AI-normal examinations in PRAIM; in PRAIM, a program-level safety-net mechanism recovered 204 cancers that would otherwise have been missed. CONCLUSION: In European population screening programs characterized by double reading and arbitration, prospective program-embedded evidence suggests that AI integration may yield a small absolute increase in cancer detection (&#x2248;1/1000) without a consistent increase in recall, alongside improved PPV and efficiency signals. These findings suggestAI primarily as a complementary reader within European screening workflows, with implementation requiring explicit quality assurance and monitoring of interval cancers and stage distribution.

Humans

Herbicolin A, an antifungal lipopeptide produced by Pantoea agglomerans APC 4211 is a promising biocontrol agent against food spoilage fungi.

Fungal contamination of food with yeast and molds is associated with major economic losses due to spoilage and also poses health risks in the form of mycotoxin production. The strain Pantoea agglomerans APC 4211 isolated from leaves of Ilex aquifolium (holly tree) has broad spectrum antifungal activity against a variety of food spoilage fungi. Genomic analysis of the strain confirmed the presence of biosynthetic gene clusters potentially encoding for the enzymatic machinery required for the production of the antifungal lipopeptide herbicolin A. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of the cell-free supernatant (CFS) confirmed the presence of molecular masses corresponding to herbicolin A (1300.8&#xa0;Da), and herbicolin B (1138&#xa0;Da). Purified herbicolin A has desirable properties for biotechnological applications, including potent antifungal activity against a range of spoilage fungi, thermal stability and resistance to proteases. The lipopeptide has low cytotoxicity against epithelial cell lines and has minimum inhibitory concentrations (MICs) lower than those of some commercial antifungal drugs (0.2-2.5&#xa0;mg/L). In a model dairy system (10% skim milk), herbicolin A demonstrated excellent solubility and stability, effectively eliminating Aspergillus niger and Penicillium notatum at a concentration of 5&#xa0;mg/L. Overall, the study determines herbicolin's A spectrum against food spoilage organisms and examines potential applications in food. In conclusion, herbicolin A is a potent, naturally occurring antifungal agent with the potential to be applied as a biopreservative in food systems, providing a safe, clean-label, and efficient compound for synthetic preservatives replacement.

Pantoea