Search PubMedSearch

SEARCH · Search PubMed

Results for “Elasticity Imaging Techniques”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

410 records · Page 5Linked to original sources

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Elucidation of microbial community structure, small-molecule metabolic and flavor profile characteristics in Xuanwei ham under different processing techniques.

This study systematically compared the impacts of traditional (TH) and modern (MH) processing techniques on the physicochemical properties, microbial community structure, metabolome, and volatile aroma compounds of Xuanwei ham. The results showed that the TH group had higher moisture content and water activity, along with a more tender texture, whereas the MH group exhibited greater hardness and chewiness. Microbiological analysis revealed that the interior of the MH group had higher species richness of both fungi and bacteria, while the TH group maintained higher fungal diversity. Metabolomic analysis identified 112 differential metabolites, with sweet amino acids and certain lipids being more enriched in modern ham, whereas traditional ham contained higher levels of umami amino acids, polyunsaturated fatty acids, and flavor compounds such as carnosine. KEGG pathway enrichment indicated that the differences were primarily concentrated in amino acid biosynthesis and metabolism-related pathways. Volatile flavoromics analysis identified 45 odor-active compounds and screened 15 key aroma-active substances. Among them, modern processed ham was significantly enriched in fatty aldehydes such as (E)-2-nonenal, hexanal, nonanal, and octanal, whereas traditional processed ham was characterized by 1-octen-3-ol, (E,E)-2,4-decadienal, methional, acetoin, and benzeneacetaldehyde. Correlation analysis confirmed that dominant microbes in Xuanwei ham were significantly associated with differential metabolites and characteristic aroma compounds, respectively. This study provides a scientific basis for standardizing production processes, enabling precise quality control, and promoting high-quality industrial development of Xuanwei ham.

Animals

Hot vs cold knife for endoscopic ablation of posterior urethral valves: a systematic review by the EAU-YAU paediatric urology working group.

INTRODUCTION: Posterior urethral valves (PUV) are the most frequent cause of congenital lower urinary tract obstruction in males. Despite early surgical ablation, up to 22% of patients develop chronic kidney disease and 11% progress to end-stage renal disease. Multiple endoscopic modalities have been described for valve ablation but the optimal technique remains uncertain. This systematic review aims to determine whether cold or hot knife ablation provides superior effectiveness for primary endoscopic treatment of PUV in a single surgical session. MATERIAL AND METHODS: A systematic search of PubMed and Embase databases was conducted to identify studies comparing cold and hot knife techniques for endoscopic ablation of PUV in children, covering all publications up to December 2025. The review was performed in accordance with PRISMA 2020 guidelines and was prospectively registered in PROSPERO (ID CRD420251180556). Original studies including patients <18 years who underwent primary valve ablation with postoperative cystoscopy or VCUG and &#x2265;6 months of follow-up were included. Quality assessment was done using RoB 2.0 for randomized trials and MINORS for observational studies. RESULTS: A total of 1581 studies were identified, of which 26 met the inclusion criteria, comprising one randomized controlled trial, five prospective, and 20 retrospective studies constituting a sum of 1725 paediatric patients. The overall methodological quality of included studies was moderate, with marked heterogeneity in design, follow-up duration, and outcome reporting, limiting direct comparisons across series. Thus statistical analysis was not possible. Of these, 829 (48.1%) underwent cold valve ablation and 896 (51.9%) underwent hot ablation techniques. Within the cold group, most patients were treated with a cold knife (80.2%), followed by balloon dilatation (7%), the Mohan valvotome (6.5%), cold hook (5%), and, rarely, a modified venous valvulotome (1.3%). Among hot techniques, 32.8% of procedures were performed by electro-fulguration with a resectoscope, 29.4% using a Bugbee electrode, 23.8% with a hook electrode and 14% with laser-based systems. Follow-up ranged from 6 months to 22 years across studies. Single-session success rates for valve ablation ranged from 22% to 100% in the cold resection group and from 71.4% to 100% in the hot resection group. Reintervention for residual valves was reported in 0%-78% of cold cases and in 0%-28.6% of hot resections. Urethral stricture rates ranged from 0% to 11.1% after cold incision and from 0% to 23.8% after hot techniques. Reporting of postoperative outcomes such as urinary tract infection, incontinence, bladder dysfunction, vesicoureteral reflux (VUR) resolution, hydronephrosis improvement, and renal function varied widely among studies and was assessed using different methodologies. CONCLUSIONS: Both cold and hot ablation techniques for PUV achieved high single-session success rates and low complication rates. Cold resection appeared slightly safer, although this finding should be interpreted cautiously given the heterogeneity and observational nature of the available data.

Humans

Endoscopic mucosal resection with precutting vs. anchoring technique using snare tip for 10-25&#x2009;mm nonpedunculated colorectal polyps: a randomized controlled trial.

BACKGROUND AND AIMS: Modified endoscopic mucosal resection (EMR) techniques using a snare tip, precutting EMR (P-EMR) and anchoring EMR (A-EMR), have been developed for the effective resection of nonpedunculated colorectal polyps measuring 10-25&#x2005;mm. Although previous studies have compared either P-EMR or A-EMR with conventional EMR, no study has directly compared these two snare tip-assisted techniques within modified EMR. This study aimed to evaluate P-EMR and A-EMR in terms of the R0 resection rate and procedure duration. METHODS: This prospective randomized controlled trial enrolled patients with nonpedunculated colorectal polyps measuring 10-25&#x2005;mm. The patients were randomly assigned to the P-EMR or A-EMR groups. The primary outcome was R0 resection rate, defined as en bloc resection with histologically tumor-free margins. Secondary outcomes included the injection-to-snaring time, total procedure time, and adverse events. RESULTS: Each group included 63 polyps, of which 126 were analyzed in the final evaluation. Both groups achieved high R0 resection rates (93.7% for P-EMR and 88.9% for A-EMR), with no significant difference ( P &#x2005;=&#x2005;0.344). However, the A-EMR group demonstrated significantly shorter injection-to-snaring time (181.8&#x2005;&#xb1;&#x2005;81.9 vs. 320.9&#x2005;&#xb1;&#x2005;143.5&#x2005;s, P &#x2005;<&#x2005;0.001) and total procedure time (259.7&#x2005;&#xb1;&#x2005;139.7 vs. 479.8&#x2005;&#xb1;&#x2005;249.0&#x2005;s, P &#x2005;<&#x2005;0.001). Adverse events, including intraprocedural and delayed bleeding, were comparable between the groups. CONCLUSION: Both P-EMR and A-EMR demonstrated high R0 resection rates for nonpedunculated polyps measuring 10-25&#x2005;mm. However, A-EMR achieved these outcomes with a shorter procedure time than P-EMR.

Humans

Prenatal exome sequencing of fetuses with central nervous system anomalies based on prenatal ultrasound and magnetic resonance imaging diagnosis: A retrospective cohort study with a systematic review and meta-analysis.

INTRODUCTION: Fetal central nervous system (CNS) abnormalities have diverse etiologies, with genetic factors as a major contributor. Prenatal exome sequencing (ES) is a powerful tool for precise molecular diagnosis of CNS anomalies, but its diagnostic yield varies among studies. This study aimed to evaluate the additional diagnostic yield of prenatal ES compared with chromosomal microarray analysis (CMA) in fetuses with CNS anomalies detected by prenatal imaging. MATERIAL AND METHODS: We collected ES results from fetuses diagnosed with CNS anomalies by prenatal imaging (2019-2024) who had negative results. Subgroup analyses assessed phenotype-specific ES diagnostic yield for associated genes and variants. A systematic review and meta-analysis incorporating our data and published studies further explored the association between phenotype and diagnostic yield. RESULTS: In the cohort study of 219 cases, ES identified pathogenic/likely pathogenic single nucleotide variations in 36 cases (16%). The highest diagnostic yield of ES was in cases with multisystem malformations (25%, 14/55), followed by multiple CNS anomalies (15%, 2/13) and isolated CNS anomalies (13%, 20/151). The most commonly identified isolated CNS anomaly was agenesis of the corpus callosum (31%, 5/16). Neural tube defects with urogenital anomalies were associated with a positive ES finding in 57% (4/7) of cases. The meta-analysis of 989 cases from 22 studies showed a pooled diagnostic yield of ES of 27% (95% CI, 21%-34%). The highest diagnostic yield of ES was in cases of corpus callosum anomalies with facial abnormalities (75%, 8/11) and neural tube defects with urogenital malformations (80%, 12/15). The diagnostic yield of ES for three or more CNS abnormalities was 43% (95% CI, 31%-58%), significantly higher than that for only two abnormalities (10%, 95% CI, 4%-18%). No significant difference in diagnostic yield was found between cases identified by prenatal MRI combined with ultrasound (27%, 95% CI, 20%-36%) and those identified by ultrasound alone (25%, 95% CI, 17%-35%). CONCLUSIONS: ES provided a significantly higher diagnostic yield than CMA for fetal CNS abnormalities, with diagnostic yields varying by phenotype. The systematic review and meta-analysis confirmed that the complexity and combination of malformations are key factors associated with differences in ES diagnostic yield.

Humans

Artificial neural network data fusion-mediated dual-mode sensor based on Fe3O4@PdIr for Salmonellatyphimurium detection in food.

Salmonella Typhimurium (S. typhimurium) is a major foodborne pathogen that poses a serious threat to public health. In this study, a colorimetric/electrochemical dual-mode biosensor assisted by artificial neural network (ANN) was developed for the sensitive detection of S. typhimurium. Fe3O4@PdIr nanocomposites with enhanced peroxidase-like activity and electrochemical performance were prepared and conjugated with an aptamer specific to S. typhimurium to obtain Fe3O4@PdIr-Apt. Through the sandwich binding of Fe3O4@PdIr-Apt and Apt to the target, the nanocomposites were attached to microplates or Au electrodes, thereby generating colorimetric and electrochemical signals. The ANN model deeply resolved the complex nonlinear relationship between the dual signals, enabling mutual correction and ultimately performing data fusion to output a single detection result, which significantly reduced the mean square error while improving detection sensitivity and reliability. This sensor exhibited a wide linear range of 2.7-2.7&#xa0;&#xd7;&#xa0;108&#xa0;CFU/mL and a low detection limit of 1.66&#xa0;CFU/mL. Additionally, this method was successfully applied to the detection of S. typhimurium in pork and milk, with a recovery rate of 95.19%&#xa0;&#x223c;&#xa0;104.07%. It indicated that the constructed sensor holds great practical potential for S. typhimurium detection.

Neural Networks, Computer

Recovering membrane interaction kinetics of single molecules from 3D tracking data.

Interactions between cytosolic biomolecules and the bacterial inner membrane are fundamental to many cellular processes, yet directly measuring their binding kinetics in living cells remains challenging. Conventional 2D single-molecule tracking analyses can be insufficient, particularly when membrane association does not markedly alter the diffusion rate. Here, we present a method to recover membrane interaction kinetics from 3D single-molecule trajectories in rod-shaped bacteria. Using simulated 3D tracking data, we identify membrane-associated motion by quantifying how well short trajectory segments follow the circular curvature of the cell membrane. The resulting measure is further analyzed using a hidden Markov modeling framework, enabling robust discrimination between cytosolic and membrane-bound states and capturing the dynamics of state transitions without requiring diffusion-rate changes or direct colocalization with membrane markers. This work establishes a general framework for extracting membrane interaction kinetics from 3D single-molecule tracking data in live bacteria and highlights the value of realistic microscopy simulations for quantitative interpretation and systematic bias assessment.

Kinetics

Synaptic vesicle glycoprotein 2A PET imaging in parkinsonian &#x3b1;-synucleinopathies: a systematic review.

Synaptic dysfunction is increasingly recognized as an early and biologically relevant component of &#x3b1;-synucleinopathies. However, conventional imaging biomarkers mainly assess dopaminergic dysfunction, glucose metabolism, or structural damage rather than presynaptic density itself. Synaptic vesicle glycoprotein 2A (SV2A) PET enables in vivo assessment of presynaptic terminal integrity and may provide complementary information in Parkinson's disease (PD), Parkinson's disease dementia/dementia with Lewy bodies (PDD/DLB), and multiple system atrophy (MSA). This systematic review synthesized the available evidence on SV2A-targeted PET in parkinsonian &#x3b1;-synucleinopathies, focusing on regional imaging patterns, clinical associations, longitudinal findings, and methodological determinants of interpretation. Seventeen reports were included. In PD, the most recurrent finding was reduced SV2A binding in the substantia nigra, although additional involvement of brainstem, caudate, striatal, thalamic, raphe, or cortical regions was reported in selected cohorts. In PDD/DLB, abnormalities appeared broader and more cortical, with evidence of association between cortical SV2A binding and cognitive performance. In MSA, one study suggested a distinct infratentorial and cerebellar pattern with potential relevance for phenotypic stratification. SV2A PET is a promising research biomarker for biological characterization of synucleinopathies. However, the field remains limited by small cohorts, methodological heterogeneity, variable quantification strategies, limited longitudinal evidence, and potential cohort overlap. Multicentre validation and harmonized protocols are required before clinical translation.

Humans

Spatially confined electrochemical strategy with DNA-assembled nanogaps for SNP detection.

Accurate detection of low-abundance single nucleotide polymorphisms (SNPs) against a large excess of homologous wild-type sequences requires both selective molecular recognition and effective transduction of small sequence differences into measurable signals. Here, we report a spatially confined electrochemical strategy that couples sequence-selective recognition with size-dependent mass-transport gating. DNA-hybridization-driven self-assembly of gold nanoparticles (AuNPs) forms a three-dimensional self-assembled electrode (3D-SAE) with a DNA-defined interparticle architecture. Competitive probes (SP/WP) convert single-base recognition into distinct molecular-size states: the SNP-associated pathway preferentially triggers a hybridization chain reaction (HCR), generating bulky AuNP-anchored HCR/methylene blue complexes (Au@HCR/MB) with reduced electrochemical accessibility through the porous 3D-SAE, whereas the wild-type pathway does not trigger HCR and maintains a high-current response from more readily accessible MB-containing species. Thus, sequence recognition is translated into a molecular-size difference and subsequently into an electrochemical signal through differential mass transport. Under buffer conditions, the platform achieved a statistically estimated detection limit of &#x223c;0.47&#x202f;fM and a quantitative range of 1&#x202f;fM-100 pM. It discriminated a 0.1% mutant abundance in a fragmented genomic-DNA background. The downstream signal-transduction chemistry is enzyme-free and isothermal. This work establishes a mechanistical recognition-size-conversion-mass-transport-gating architecture for electrochemical nucleic acid analysis.

Polymorphism, Single Nucleotide

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (&#x2265;&#x2009;13&#x2009;mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2&#x2009;=&#x2009;0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2&#x2009;=&#x2009;59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

Rational design of high-productivity perfusion processes for CHO Cells: From growth inhibitory strategies to model-driven optimization.

While perfusion culture for Chinese hamster ovary (CHO) cells offers advantages such as continuous operation and flexibility, it suffers from product loss through cell bleeding and difficulties in reaching high productivity due to sustained rapid cell growth. Growth inhibitory strategies are widely used to enhance productivity in fed&#x2011;batch processes; however, their practical implementation and comparative effectiveness in perfusion processes remain insufficiently explored. Meanwhile, process development often relies on costly trial&#x2011;and&#x2011;error approaches. Here, we systematically compared three growth inhibitory strategies in perfusion culture-low cell&#x2011;specific perfusion rate (CSPR), sodium butyrate, and mild hypothermia-with respect to cell growth, metabolism, productivity, and product quality. Genome&#x2011;scale metabolic flux sampling analysis revealed that low&#x2011;CSPR and sodium butyrate induce a convergent up&#x2011;regulation of energy metabolism, correlating with greater gains in specific productivity (qp). Building on this insight, we developed a growth&#x2011;kinetic model for the combined low&#x2011;CSPR + butyrate strategy, incorporating parameter uncertainty. This model&#x2011;guided framework enabled the rational design of two distinct high&#x2011;productivity perfusion processes: a sustained mode that achieved robust long&#x2011;term stability alongside substantial productivity gains, and a high&#x2011;intensity mode that pushed qp and daily volumetric titer to their maxima, with increases of up to 108.94% and 190.36%, respectively, in a model CHO cell line with a moderate baseline productivity. Our study provides a proof&#x2011;of&#x2011;concept framework for perfusion intensification, from strategy selection to rational process design.

Animals

Physical Appearance Anxiety and Eating Disorders Symptomatology: A Systematic Review and Meta-Analysis.

The present study aimed to assess the link between physical appearance anxiety (PAA) and eating disorder (ED) symptomatology by a meta-analysis of existing literature. Eligible studies were searched across six electronic databases up until November 20, 2025. Pooled effect sizes (r) were calculated using random-effects models. Potential variables that influence effect heterogeneity were analyzed by univariable and multivariable meta-regressions. Influence analyses and a three-parameter selection model (3PSM) were used to assess robustness of the results and publication bias. Twenty-seven effect sizes from 21 studies (N&#x2009;=&#x2009;5261) were obtained. The results indicated a strong association (i.e., r&#x2009;=&#x2009;0.559) between the two variables under consideration, which was notably stronger (i) among females compared to males; and (ii) for overall eating disorder symptoms rather than bulimic symptoms. The results of this study advocate for further investigation into the effectiveness of addressing anxiety responses related to personal body traits, particularly among females, within the context of preventing and treating eating disorders.

Humans

Intravenous thrombolysis for ischemic stroke in extended time window selected with CT perfusion: a systematic review and meta-analysis.

PURPOSE: Recent randomized controlled trials (RCTs) have provided new evidence regarding the efficacy and safety of intravenous thrombolysis (IVT) in patients with acute ischemic stroke (AIS) presenting within the extended time window (ETW). We performed a systematic review and meta-analysis to evaluate the efficacy and safety of IVT, in patients treated within the ETW and selected with perfusion imaging criteria, predominantly computed tomography perfusion (CTP). METHODS: A systematic review and meta-analysis, registered in PROSPERO, was conducted including all available RCTs comparing IVT with best medical treatment (BMT) in patients with AIS within the ETW, selected using advanced perfusion imaging criteria. The predefined efficacy outcomes were excellent functional outcome and good functional outcome at 3 months. The safety endpoints included symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days. RESULTS: Six RCTs, including 1182 patients treated with IVT and 1176 patients receiving BMT, were included. IVT was associated with a higher likelihood of achieving excellent and good functional outcomes at 3 months. Exploratory subgroup analyses by treatment timing suggested consistent findings up to 24 hours. No significant difference in 90-day mortality was observed between groups, whereas IVT was associated with an increased risk of sICH. CONCLUSION: Treatment with IVT in the ETW (4.5-24 h) in patients selected using advanced perfusion imaging, predominantly CTP, may be associated with improved functional outcomes in patients with AIS. Although IVT was associated with an increased risk of sICH, no significant increase in 90-day mortality was observed. PROSPERO REGISTRATION: CRD420261304314.

Aged

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Spatial proximity or vector orientation? Re-evaluating ECG interpretation in anterior myocardial infarction using cardiac magnetic resonance.

BACKGROUND: The electrocardiogram (ECG) is widely used to infer infarct location and extent in anterior myocardial infarction (MI), based on either anatomical lead proximity or vectorial orientation of ST-segment deviation. However, the validity of these approaches against direct imaging of myocardial injury remains uncertain. METHODS: In this prospective study, 105 patients with anterior MI underwent cardiac magnetic resonance (CMR) imaging 3-7&#xa0;days after presentation. Admission ECGs were analyzed using (1) conventional ECG localization categories, and (2) simplified frontal and horizontal ST-axis orientation. CMR-defined injury distribution was assessed using late gadolinium enhancement and myocardial edema imaging. RESULTS: Conventional ECG localization categories demonstrated no significant association with CMR-defined infarct distribution (P&#xa0;=&#xa0;0.24), with poor agreement (&#x3ba;&#xa0;=&#xa0;0.122) and substantial overlap across categories. Simplified ST-axis orientation showed modest and inconsistent associations with infarct location and did not meaningfully explain infarct size. In contrast, global ST-segment burden was associated with CMR-defined infarct size (&#x3a3;STE: standardized &#x3b2;&#xa0;=&#xa0;0.307, P&#xa0;=&#xa0;0.002; lead count: standardized &#x3b2;&#xa0;=&#xa0;0.267, P&#xa0;=&#xa0;0.007). CONCLUSIONS: In this selected cohort of reperfused LAD-related anterior STEMI patients undergoing early CMR, conventional ECG localization categories and simplified ST-axis orientation showed poor or inconsistent correspondence with CMR-defined infarct distribution, whereas global ST-segment burden showed a modest association with infarct size. These findings suggest that, in this cohort, the ECG may be better suited to reflect the extent of myocardial injury rather than its precise anatomical location.

Humans

Saliva-based RT-LAMP assays support heat shock protein 70 as a promising transcript marker for estrus identification in buffaloes.

Buffaloes do not exhibit overt estrus signs particularly during summer, leading to a significant economic loss to farmers. Previous studies have identified several candidate transcripts (HSP70, TIMP1, TLR4 and HSD17B1), abundant in buffalo saliva during estrus stage. However, there is no widely applicable technology for estrus detection targeting these transcripts. Therefore, the present study aimed to develop reverse transcription loop mediated isothermal amplification (RT-LAMP) assays for these candidate transcripts using buffalo saliva. Saliva samples were collected from 10 cyclic buffaloes and RT-LAMP assays were optimized for salivary RNA as well as direct saliva. Among the four candidate transcripts, HSP70 showed a statistically significant colour change (p-value&#x2009;=&#x2009;0.0191) at the estrus stage compared to the diestrus stage. This abundance of HSP70 was also supported in large simulated population datasets (10,000 animals) generated using R. Further, the RT-LAMP assays were tested using direct saliva without RNA isolation, and the colour change in the samples during estrus suggested the feasibility of estrus identification using direct saliva, overcoming the tedious step of RNA isolation. The detection of HSP70 using either direct saliva or salivary RNA indicated its potential as a marker for estrus identification. Similarly, TLR4 appeared to be another potential biomarker for RT-LAMP reaction using direct saliva, but it needs further validation in both RNA and direct saliva samples. Overall, the proof-of-concept on RT-LAMP assays optimized for salivary transcripts in the present study would be useful for estrus identification in tropical production systems following further validation on a larger sample size.

Animals

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans