Search PubMedSearch

SEARCH · Search PubMed

Results for “measurement error”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

670 records · Page 4Linked to original sources

Seventeen-year follow-up of hypophosphatasia diagnosed in middle-aged siblings harboring a novel intronic and a rare missense ALPL gene mutation.

Hypophosphatasia (HPP) is the rare inborn-error-of-metabolism that features impaired mineralization of the skeleton and teeth due to a deactivating mutation or mutations of the gene ALPL which encodes the tissue-nonspecific isoenzyme of alkaline phosphatase (TNSALP). We report 17-year follow-up of twin sisters and a brother referred in middle-age for painful proximal femoral "stress fractures" and then diagnosed with HPP. They reported generalized muscle and bone pain, metatarsal fractures, arthropathy and, since childhood, tooth loss. Their concordant findings were explained by compound heterozygosity in ALPL for a rare maternal missense mutation (c.1403C > T, p.Ala468Val) in exon 12, together with a novel presumably paternal change (c.863-14G > A) predicting a cryptic mRNA splice site in intron 8. Fractures continued during follow-up until one sister received a three-and-one-half-year course of hydroxyapatite-targeted TNSALP supplementation therapy (asfotase alfa) during which substantial improvement occurred in her clinical, biochemical, and functional parameters as well as quality of life. Following subsequent unplanned treatment cessation she suffered significant clinical deterioration, including new fractures and loss of mobility. Her bone histopathology documented osteomalacia. Treatment resumption restored its benefits. Among ten asymptomatic family members evaluated in this four-generation kindred, eight were carriers heterozygous for either ALPL mutation. Those harboring the maternal missense defect manifested mild hypophosphatasemia, suggesting a dominant-negative mutation effect. This experience underscores the importance of in-depth phenotyping and then clinical follow-up to characterize ALPL variant combinations, and for maintaining effective asfotase alfa treatment.

Humans

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2 - V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12‑lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2 - V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12‑lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000 Hz. In the standard recording, the digital PBL was calculated as V2 - V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008 mV). CONCLUSIONS: Physical acquisition of the V2 - V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans

Alternative End Joining Dependency Imposed by miR-21-5p Defines Radiation Resistance and a Targetable Vulnerability in Oral Squamous Cell Carcinoma.

PURPOSE: Clinical control of oral squamous cell carcinoma (OSCC) is constrained by heterogeneous radiosensitivity driven by divergent DNA damage response programs. The architecture and functional contribution of alternative end joining (Alt-EJ), an error-prone DNA double-strand break (DSB) repair pathway frequently upregulated in cancer, to radiation resistance remains poorly defined. METHODS AND MATERIALS: We profiled microRNAs in radioresistant OSCC clones and performed multiomic integration across an institutional OSCC cohort, an external OSCC cohort from the Gene Expression Omnibus, The Cancer Genome Atlas pan-cancer tumors, and cell lines characterized by Sanger Genomics of Drug Sensitivity in Cancer to infer DNA damage response characteristics, genomic scar features, drug sensitivity, and radiation therapy outcomes. DSB repair capacity and pathway usage were validated using functional assays, including Alt-EJ reporters and droplet digital PCR quantification of microhomology-mediated repair events. Core Alt-EJ effectors such as PARP1 and POLQ were perturbed genetically and pharmacologically. Therapeutic efficacy of PARP or POLQ inhibition with or without irradiation was tested in a syngeneic OSCC model, followed by bulk tumor transcriptomics to assess pathway engagement. RESULTS: Upregulation of miR-21-5p was not only selectively detected in radioresistant OSCC, but also modulated radiosensitivity in vitro and in vivo, and was associated with inferior postradiation therapy survival. A calibrated miR-21-5p target-gene signature tracked Alt-EJ activity across patient and mouse tumors and cancer cell lines, correlated with microhomology-mediated indels and broader genomic scarring, and predicted sensitivity to clinically available PARP inhibitors. Functionally, enforced miR-21-5p expression increased Alt-EJ usage and accelerated DSB repair, whereas inhibition or depletion of key Alt-EJ effectors reduced repair efficiency and restored radiosensitivity. In vivo, Alt-EJ targeting with PARP or POLQ inhibitor abrogated miR-21-5p-driven radiation resistance; transcriptomic profiling supported suppression of Alt-EJ programs as the operative mechanism. CONCLUSIONS: These findings establish a mechanistic link between miR-21-5p activity and Alt-EJ dependence, provide a clinically deployable signature to identify Alt-EJ-dependent OSCC, and support rational combinations of Alt-EJ targeting agents with radiation therapy to overcome treatment failure and advance precision radiation oncology.

MicroRNAs

Hyper-oncotic albumin administration reduces mortality in acute Respiratory Distress Syndrome compared to crystalloid: a systematic review and meta-analysis.

BACKGROUND: To evaluate the association between albumin administration as volume replacement and mortality in adult ARDS patients, we performed this meta-analysis and trial sequential analysis (TSA). METHODS: We searched databases including PubMed, Science Direct, Scopus, Web of Science databases and Cochrane Central Register of Controlled Trials up to 12 December 2024. We screened trials that included adult ARDS patients and compared albumin with crystalloid. The 28-day mortality served as the primary endpoint, while the oxygenation change, the length of ICU stay and the length of hospital stay were designated as secondary outcomes. To clarify the differing concentrations of albumin, we formed two distinct subgroups: the hyper-oncotic albumin subgroup (&#x2265;20%) and the iso-oncotic albumin subgroup (4%&#x223c;5%). Statistical synthesis was performed with Cochrane Review Manager 5.4.1, employing random-effects models. To mitigate random errors, TSA was implemented with &#x3b1;&#x2009;=&#x2009;0.05 and &#x3b2;&#x2009;=&#x2009;0.20 parameters. RESULTS: The analysis incorporated 5 publications: 3 randomized controlled trials (RCTs) and 2 non-randomized studies (NRSs). Overall mortality was lower in the albumin group (33.2%, 97/292) than in the crystalloid group (44.9%, 133/296) (OR = 0.61, 95%CI 0.43-0.85, p&#x2009;=&#x2009;0.004). RCTs (n&#x2009;=&#x2009;204) showed no benefit (OR = 0.83, p&#x2009;=&#x2009;0.54), but NRSs (n&#x2009;=&#x2009;384) demonstrated reduced mortality (OR = 0.52, p&#x2009;=&#x2009;0.002). Hyper-oncotic albumin was associated with lower mortality in NRSs (OR = 0.40, p&#x2009;=&#x2009;0.02) but not in RCTs (OR = 0.74, p&#x2009;=&#x2009;0.57). Iso-oncotic albumin showed no benefit (OR = 0.88, p&#x2009;=&#x2009;0.72). Regarding the impact of albumin on oxygenation, significant improvements in oxygenation were observed only on the first (p&#x2009;=&#x2009;0.05) and second days (p&#x2009;<&#x2009;0.0001). The TSA indicated a continued need for high-quality RCTs. CONCLUSIONS: Our analysis suggests that hyper-oncotic albumin may reduce mortality and improve early oxygenation in ARDS patients compared to crystalloids. Larger RCTs are urgently needed to validate these findings and define their potential role in clinical management.

Humans

Efficacy and safety of mitapivat in adults with transfusion-dependent &#x3b1;-thalassaemia or &#x3b2;-thalassaemia (ENERGIZE-T): a double-blind, randomised, multicentre, placebo-controlled, phase 3 trial.

BACKGROUND: The absence of disease-modifying therapies for patients with &#x3b1;-thalassaemia and oral disease-modifying therapies for patients with &#x3b2;-thalassaemia has been a substantial unmet need in these patients. We assessed the efficacy and safety of mitapivat, an oral allosteric activator of pyruvate kinase, in adults with transfusion-dependent thalassaemia. METHODS: ENERGIZE-T is a global, double-blind, randomised, placebo-controlled, phase 3 trial, conducted across 19 countries in North America, Europe, Asia-Pacific, South America, and the Middle East. Patients aged 18 years or older with transfusion-dependent &#x3b1;-thalassaemia or &#x3b2;-thalassaemia were randomly allocated (2:1) with a central interactive response technology system, stratified by geographical region and thalassaemia genotype, to receive 100 mg mitapivat or placebo orally twice a day for 48 weeks. The primary endpoint was transfusion reduction response (TRR), defined as a reduction of at least 50% in transfused red blood cell units with a reduction of at least two units in any consecutive 12-week period until week 48 compared with baseline. Efficacy was analysed in the full analysis set, comprising all randomly allocated patients. Type, severity, and relationship of adverse events and serious adverse events were assessed in patients who received at least one dose of study treatment. This study is registered with ClinicalTrials.gov (NCT04770779) and is active but not recruiting. FINDINGS: Between Nov 30, 2021 and May 2, 2023, 305 patients were screened, of whom 258 were randomly allocated (median age 33&#xb7;5 years [IQR 27&#xb7;0-44&#xb7;0]; 136 [53%] female and 122 [47%] male participants). Of 258 patients allocated, 238 (92%) completed the double-blind treatment period. All patients were required to have a safety follow-up approximately 4 weeks after the final dose of study drug, regardless of completion of the double-blind period or continuation into the open-label extension period. In the full analysis set, TRRs occurred in 52 (30%) of 171 patients in the mitapivat group and 11 (13%) of 87 in the placebo group (adjusted difference 18 percentage points [95% CI 8-27]; two-sided p=0&#xb7;0003). The safety analysis set comprised 172 patients in the mitapivat group (including one patient allocated to the placebo group who received one dose of mitapivat in error) and 85 in the placebo group. Adverse events were reported in 155 (90%) patients treated with mitapivat and 71 (84%) treated with placebo; the most common events with mitapivat were headache, upper respiratory tract infection, initial insomnia, diarrhoea, and fatigue. Serious adverse events were reported in 19 (11%) patients treated with mitapivat and 13 (15%) treated with placebo. Ten (6%) patients who received mitapivat and one (1%) who received placebo discontinued study treatment due to adverse events. No deaths were reported. INTERPRETATION: Mitapivat significantly reduced the transfusion burden and was generally well tolerated, showing a favourable benefit-risk profile. These findings support mitapivat as the first oral disease-modifying therapy for adults with transfusion-dependent &#x3b1;-thalassaemia or &#x3b2;-thalassaemia, providing a new treatment option to reduce transfusion burden in this patient population. FUNDING: Agios Pharmaceuticals, Inc.

Adult

Patient-reported outcomes in pediatric regional anesthesia trials: current use and limitations.

PURPOSE OF REVIEW: This review examines the current use and limitations of patient-reported outcome measures (PROMs) in pediatric regional anesthesia research. Despite the increasing emphasis on patient-centered outcomes, existing pediatric outcome assessment frameworks may inadequately capture the pain experience and interference with daily living. RECENT FINDINGS: Across 17 identified randomized controlled trials and 15 ongoing studies, PROM use remains highly variable, with consistent reliance on observational pain scales such as the Face, Legs, Activity, Cry, and Consolability scale and limited incorporation of standardized, longitudinal health-related quality-of-life measures. SUMMARY: Current pediatric PROM frameworks remain fragmented, limiting comprehensive evaluation of recovery. Greater standardization and incorporation of developmentally appropriate, longitudinal outcome measures are needed to better align clinical research with meaningful patient-centered endpoints and to improve assessment of functional and psychosocial recovery.

Humans

Timing of OMERACT core domain measurement in gout clinical trials: a systematic review of randomised trials.

AIMS: The Outcome Measures in Rheumatology (OMERACT) initiative has endorsed core domain sets for gout trials. The aims of this study were to evaluate the time points and frequencies at which the gout core domains are measured in existing gout urate-lowering therapy and gout flare trials, and whether all collected measurements were reported. METHODS: Urate-lowering therapy (n = 29) and gout flare randomised clinical trials (n = 14) from 2005 were identified from a prior systematic review of core domain reporting. Data were extracted for the time points and frequencies at which each core domain was measured, as well as whether all collected measurements were reported. RESULTS: In urate-lowering therapy trials, the core domains were measured at seven different frequencies. Serum urate and gout flares were most commonly measured monthly, and tophus burden was most commonly measured three monthly. Reporting of all collected measurements varied, from 24/29 (83%) trials for serum urate to 0/2 (0%) trials for activity limitation. In gout flare trials, core domains were measured at nine different frequencies. Pain, joint tenderness and joint swelling were most commonly measured monthly. Reporting of all collected measurements varied, from 13/14 (93%) trials for pain to 3/8 (37.5%) trials for joint tenderness. CONCLUSION: In both urate-lowering therapy and gout flare trials, there is substantial variability in when the core domains are measured, and reporting of collected measurements is inconsistent. This work provides the foundation for a consensus process to establish standardised time points and frequencies for measuring the OMERACT-endorsed gout core domains.

Gout

An Assessment of Reliability Estimation Methods for Binomial Health Care Quality Measures.

We evaluated the performance of commonly used methods for estimating the reliability of binomial health care quality measures using simulated datasets spanning a range of performance score means and variances, numbers of entities, and patient sample sizes. For each simulation, reliability was estimated for all selected methods and compared with the known true reliability derived from the simulation parameters, with methods assessed on their accuracy and precision. Logistic regression with reliability estimated on the outcome scale demonstrated the highest accuracy and precision among all methods evaluated. The widely used Adams beta-binomial method performed poorly, although a modification recommended by Nieser and Harris substantially improved its performance. These approaches are applicable only to binomial measures. Among methods that can be applied to both binomial and continuous measures, permutation resampling of the Spearman rank correlation coefficient was the most accurate and precise, outperforming other commonly used approaches. Overall, for binomial quality measures, logistic regression on the outcome scale is the preferred method for reliability estimation, followed closely by the modified beta-binomial approach, while for non-binomial measures, permutation-based Spearman rank correlation appears to be the most suitable method.

Reproducibility of Results

Sensor-based measures of knee brace adherence have low agreement with self-report methods: A multi-measure study among knee osteoarthritis patients.

OBJECTIVE: To explore agreement between self-report and objectively measured adherence to brace wearing by patients with knee osteoarthritis. METHOD: A single-arm observational analysis nested within the PROP OA randomised controlled trial (ISRCTN28555470). Of 237 adults with symptomatic knee osteoarthritis randomised to brace treatment, 60 were included in this sub-study investigating three different methods of assessing knee brace wear time over 26 weeks: 1. Self-report questionnaires (SRQ) at 12 weeks and 26 weeks; 2. Short message service (SMS) questions (days worn in past week, typical hours per day when worn) administered from week 1 to week 24; 3. A skin temperature sensor embedded in the brace, sampling every 10&#x202f;min for 26 weeks. The presence and reason for the sensor were concealed from participants. The estimated proportion of participants meeting "minimum brace use", defined a priori as &#x2265;1&#x202f;h on &#x2265;2 days in past week, was described for each measurement method, overall and by brace type (unloader, neutral). For temperature sensor measurements, time spent above 24&#xb0;C and time spent above 25&#xb0;C were used. Agreement between the measures was summarised by percentage agreement and kappa (&#x138;). RESULTS: The estimated proportions of participants meeting "minimum brace use" at 12 weeks were 83% (SRQ), 83% (SMS), 60% and 58% (temperature sensor, 24&#xb0;C and 25&#xb0;C thresholds, respectively). At 26 weeks, the corresponding estimates reduced to 72%, 71% (SMS at 24 weeks), 43% and 37%. Sensor data suggested the sharpest decline in brace use occurred within the first 12 weeks. Agreement between self-report measures was higher than between self-report measures and sensor (SRQ vs SMS at 12 weeks: 92% agreement, &#x138;=0.67 (95%CI: 0.34, 1.00); SRQ vs Sensor at 12 weeks: 74%, 0.35 (0.10, 0.60); SMS vs Sens at 12 weeks: 76%, 0.36 (0.05, 0.66). Agreement between all measurement methods reduced at 26 weeks. CONCLUSIONS: This novel use of a temperature sensor to monitor brace adherence in knee osteoarthritis indicates that self-report adherence substantially overestimates knee brace wearing time, with implications for clinical trials and practice.

Humans

Longitudinal Repeated Protein Measurements in a Multiethnic Cohort Identify Novel Diabetes Biomarkers That Reveal Unique Disease Pathways.

There is up to a fourfold increase in diabetes biomarkers identified with longitudinal repeated versus single time point proteomic measurements. The increase in biomarkers identified with longitudinal repeated measurements is supported by a similar proportion being nominated as causal for type 2 diabetes with Mendelian randomization. Proteins unique to the longitudinal repeated analyses highlighted biological pathways (e.g., posttranslational protein modification and cellular structure and cycle regulation) that were distinct from pathways enriched among the shared proteins (e.g., small-molecule metabolic and catabolic processes). Longitudinal protein measurements identify additional novel disease biomarkers and disparate biological pathways compared with single measurement analyses.

Journal Article

Endoscopic Ultrasound-Guided Versus Transjugular Portal Pressure Measurements: Systematic Review and Meta-Analysis.

PURPOSE: Published reviews of endoscopic ultrasound-guided portal pressure gradient (EUS-PPG) have emphasized feasibility and safety. We performed a systematic review and meta-analysis specifically to evaluate how closely EUS-based portal pressure measurements track invasive comparator measurements in prospective paired studies and to summarize agreement, technical success, and adverse events. METHODS: We searched major databases through January 2026 for prospective cohorts reporting same-patient EUS-based portal pressure measurement and invasive hemodynamic measurements. Correlations were pooled with random-effects models and analyzed separately for studies comparing EUS-PPG with hepatic venous pressure gradient (HVPG) and studies comparing EUS-based portal measurements with direct portal venous pressure. Agreement and threshold discordance were summarized descriptively. RESULTS: Six prospective cohorts (127 attempted procedures) were included. In studies using HVPG as the comparator, the pooled correlation was 0.82 (95% CI, 0.72-0.89; I2&#x2009;=&#x2009;0%). In studies comparing EUS-based portal measurements with direct portal venous pressure, the pooled correlation was 0.86 (95% CI, 0.72-0.93; I2&#x2009;=&#x2009;16.9%). Technical success was 95.3%. EUS-PPG-attributed adverse events occurred in 2.4% of procedures, with no procedure-related deaths. Agreement data were limited. Reported limits of agreement were wide (approximately -&#xa0;6 to&#x2009;+&#x2009;7&#xa0;mmHg), and discrepancies of 5&#xa0;mmHg or greater occurred in 4 of 30 paired measurements. CONCLUSIONS: EUS-based portal pressure measurement is feasible and shows a strong association with invasive hemodynamic comparators, but the evidence base remains small (six cohorts, 127 attempted procedures). Further study will be necessary to establish patient-level agreement, procedural reproducibility, EUS-specific clinically significant portal hypertension thresholds, and whether HVPG-based decision thresholds can be transferred to EUS-derived measurements.

Humans

Genome-wide association study of estimated glomerular filtration rate using repeated measurements in the Taiwan Biobank.

BACKGROUND: Chronic kidney disease (CKD) is a major global public health issue, with genetic factors playing a significant role in kidney function. Although genome-wide association studies (GWAS) have identified numerous loci associated with estimated glomerular filtration rate (eGFR), most studies relied on a single time-point measurement, which limits the capacity to account for within-individual measurement variability. METHODS: We performed a repeated-measurement GWAS in the prospective Taiwan Biobank (Taiwanese ancestry; n = 25,004) using two repeated creatinine-based eGFR measurements. Repeated eGFR values were analyzed using a linear mixed-effects model with a subject-specific random intercept and time-varying covariates, providing a more precise estimate of eGFR level. Identified loci underwent functional annotation (expression quantitative trait locus, deleteriousness prediction, and epigenetic markers) and were compared with results from a single-measurement GWAS. RESULTS: Six loci associated with eGFR were identified, including four previously reported regions (1q22, 4q21.1, 11p14.1, and 17q21.2) and two additional loci (6p21.32 and 15q24.2). Functional annotation implicated several candidate genes-such as MUC1/EFNA1, SHROOM3, HLA-DQB1, MPPED2, NRG4, and PGAP3/FBXL20-in the regulation of kidney function. CONCLUSION: Incorporating repeated eGFR measurements into GWAS may improve phenotypic precision for identifying genetic associations with kidney function. This study identified eGFR-associated loci and biologically plausible candidate genes in a Taiwanese population, which require further replication and functional validation.

Chronic kidney disease

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

The impact of absolute change in tibiofemoral morphology on patient reported outcome measures post total knee arthroplasty.

BACKGROUND: Reconstructing knee morphology and alignment is important for outcomes post total knee arthroplasty (TKA). Personalised alignment strategies are proposed to improve outcomes by replicating native alignment. However, how change in morphology affects patient outcomes is unclear. This study aimed to investigate the relationship between absolute change in morphological measures post-TKA and patient reported outcome measures (PROMs). METHOD: An observational analysis of a randomised clinical trial was conducted. Participants received preoperative and postoperative CT scans and completed PROMs at six-months post-TKA. Absolute change in hip-knee-ankle angle, medial proximal tibial angle, lateral distal femoral angle, non-weightbearing joint line convergence angle, tibial and femoral rotation, and posterior tibial slope (PTS) were calculated. PROMs included visual analogue scales of pain and satisfaction (0-100), Oxford Knee Score, Forgotten Joint Score, and the Kujala Score. Regression and principal component (PCA) analyses investigated relationships between PROMs and change in morphology. RESULTS: Sixty-one participants were included for analysis (61% women, age 66.9&#xa0;&#xb1;&#xa0;9.1 [mean&#xa0;&#xb1;&#xa0;SD] years, BMI 32.8&#xa0;&#xb1;&#xa0;6.8&#xa0;kg/m2). The PCA demonstrated coronal, axial, and sagittal plane measures were interdependent, with over 65% of variability driven by change in tibial rotation (PC1) and the PTS (PC2). The regression analysis showed no relationships between morphological change and PROMs postoperatively. CONCLUSION: Tibiofemoral morphology was interrelated across coronal, axial, and sagittal planes. However, this study suggests absolute morphological change had minimal impact upon PROMs at six-months post-TKA. Future research should clearly distinguish between osteoarthritic versus prearthritic alignment and consider the influence of soft-tissue releases upon PROMs.

Humans

Reliability of resting heart rate measurements in atrial fibrillation.

BACKGROUND: Heart rate (HR) control in atrial fibrillation (AF) is commonly guided by resting HR measurements, usually with 12&#x2011;lead ECG or in-office pulse palpation. OBJECTIVES: We aimed to assess the reliability of resting HR measurements in AF patients with long-term ambulatory ECG and activity monitoring. METHODS: We included patients who had recorded a full-disclosure ambulatory ECG with a mobile cardiac telemetry device equipped with an accelerometer (PocketECG, MEDICALgorithmics, Poland), with at least 95% AF. Resting HR samples (&#x2264;20 per individual/day) were collected as 10-s daytime (8&#xa0;am to 8&#xa0;pm) measurements after &#x2265;10&#xa0;min of rest. These samples were compared to each individual's mean daytime resting HR. RESULTS: In 832 patients (median age 77 (interquartile range (IQR) 69-83) years, 42% women) with a median registration duration of 13&#xa0;days (IQR 7-22), the population mean daytime resting HR was 85 (&#xb1;15) beats per minute (bpm). A single resting HR differed from the mean daytime resting HR by a mean of &#xb1;10.4% (IQR 3.6-14.4%). When the mean daytime resting HR was &#x2265;110&#xa0;bpm, 29% of resting HR samples were&#xa0;<&#xa0;110&#xa0;bpm, and when the mean daytime resting HR was 80-109&#xa0;bpm,11% of samples were&#xa0;&#x2265;&#xa0;110&#xa0;bpm. Resting HR measurement variability decreased to 5.3% (IQR 1.9-7.5%) when four resting HR samples were averaged. CONCLUSION: In patients with AF, a single resting HR measurement often differs substantially from the mean daytime resting HR. When a precise measurement is clinically relevant, repeated resting HR sampling or ambulatory monitoring can address this measurement imprecision.

Humans

Measuring Coping Strategies in Daily Life: A Systematic Review of Experience Sampling Methodology and Daily Diary Studies.

Advances in daily diary methods and experience sampling method (ESM) have improved the study of coping strategies in daily life and their role in shaping health and well-being. In this review, we examine study designs, measurement approaches, and analytical practices used to investigate coping in natural contexts. We performed a systematic review of studies published before 5 December 2025 that used daily diary or ESM to measure coping strategies over multiple days or moments. Studies were examined with regard to sampling schemes, assessment frequency and duration, measurement of coping strategies, incorporation of stressor appraisals, and analytic techniques used to model coping processes. Fifty-five studies met the inclusion criteria. Results indicated that 80% employed end-of-day diary designs, generally lasting 1-3 weeks, whereas higher-frequency ESM protocols were less common and ranged 2-14&#xa0;days. Coping strategies were often assessed using abbreviated or single-item measures, frequently adapted from established questionnaires. Many studies incorporated appraisals such as perceived stressor intensity or controllability, enabling tests of coping flexibility. Multilevel modelling was the dominant analytic approach, allowing researchers to distinguish within-person dynamics from between-person differences. However, analyses were predominantly concurrent, and temporally ordered models remained comparatively rare. Overall, the literature demonstrates substantial progress in capturing coping in everyday contexts, yet heterogeneity in measurement and limited use of temporal modelling constrain cumulative knowledge about the temporal links between coping and psychological and physiological health outcomes. Future research would benefit from greater alignment between theoretical assumptions, assessment strategies, and analytic methods.

Humans