Search PubMedSearch

SEARCH · Search PubMed

Results for “Second Generation Cephalosporins”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

559 records · Page 4Linked to original sources

Impact of neoprene wetsuits on lung volumes and work of breathing: implications for military diver safety and performance.

INTRODUCTION: Neoprene wetsuits may impose mechanical constraints on the chest wall, potentially altering respiratory function. This study investigated the impact of neoprene wetsuits on lung volumes, airway mechanics, and work of breathing (WOB) in healthy male divers. METHODS: A randomised crossover trial was conducted with 31 male divers at the Royal Netherlands Navy Diving Medical Centre. Participants underwent pulmonary function testing, including spirometry, body plethysmography, the forced oscillation technique (FOT), and diffusion capacity measurements, both with and without a hoodless standardised 5 mm neoprene full body wetsuit with a neoprene neck seal. Primary outcomes included changes in forced vital capacity (FVC), functional residual capacity (FRC), airway resistance (Raw), reactance (Xrs), and WOB. RESULTS: Wearing a neoprene wetsuit led to statistically significant reductions in FVC (2.8%, P < 0.05), forced expiration in one second (2.9%, P < 0.05), FRC (4.0%, P < 0.05), and expiratory reserve volume (10.9%, P < 0.05), alongside increases in inspiratory capacity and tidal volume. Raw increased significantly (P < 0.05), while the FOT revealed altered airway mechanics, evidenced by increased Xrs at multiple frequencies (P < 0.05). Diffusion capacity remained unchanged, suggesting preserved alveolar-capillary function. CONCLUSIONS: Neoprene wetsuits induce mechanically restrictive effects on the chest wall, reducing static and dynamic lung volumes and increasing WOB. While these changes may not be clinically relevant at rest, their impact needs to be determined during strenuous or prolonged dives, particularly when combined with other equipment that limits thorax excursions. Future research should explore the effects of the military 5 mm wetsuit under immersed conditions to better understand their operational impact on diver performance and safety.

Male

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2&#xa0;-&#xa0;V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12&#x2011;lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2&#xa0;-&#xa0;V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12&#x2011;lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000&#xa0;Hz. In the standard recording, the digital PBL was calculated as V2&#xa0;-&#xa0;V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008&#xa0;mV). CONCLUSIONS: Physical acquisition of the V2&#xa0;-&#xa0;V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans

Yoga MAT: A factorial randomized study using the Multiphase Optimization Strategy to develop a multicomponent yoga intervention for people with chronic pain taking medications for opioid use disorder.

BACKGROUND: People taking medications for opioid use disorder (MOUD) commonly experience chronic pain. Yoga interventions show promise for decreasing pain-related disability in other populations. More time spent in yoga practice may improve pain-related outcomes. METHODS: The Multiphase Optimization Strategy (MOST) provided the framework for developing an optimized yoga intervention package. In a 2x2x2x2 factorial experiment, we evaluated four candidate intervention components which, when added to a weekly yoga class, might increase yoga engagement. The primary outcome was minutes per week of yoga practice (classes and other yoga practice) over the 12-week intervention period. We sought to determine which combination of intervention components was associated with the most yoga practice for people with chronic pain taking buprenorphine or methadone as MOUD. RESULTS: We enrolled 192 adults. There was a significant main effect for Component "B" (having two private sessions with a yoga teachers; IRR = 1.10, 90%CI 1.02; 1.18), and a synergistic interaction between Components "B" and "D" (D was financial incentives for attending class; IRR = 1.11, 90%CI 1.02; 1.19). This combination of these two components (without other potential components) was associated with the second highest model-predicted mean minutes of yoga per week (157.1min; 90% CI = 120.1-194.0) which was only 4min less than the combination including all four components. CONCLUSIONS: We identified a combination of intervention components as the optimized intervention. A next step will be to test the effect of this optimized intervention on pain and substance use outcomes in a randomized controlled clinical trial.

Humans

The Interrelationship between Cadmium, Smoking, and Migraine in the ELSA-Brasil Study.

This study explored the relationship between serum cadmium (Cd), smoking exposure, and migraine in the ELSA-Brasil cohort (2008-2010). The analysis included 2,750 participants whose serum Cd levels were measured using inductively coupled plasma mass spectrometry. Smoking exposure was assessed using self-report data of active smoking and second-hand smoke. Migraine, including definite and probable migraine, was diagnosed according to the International Classification of Headache Disorders, 3rd edition (ICHD-3). Logistic regression was used to estimate the odds of migraine across serum Cd quintiles, using the third quintile as the reference category, while linear regression examined the relationship between smoking exposure and Cd levels. Polynomial contrasts tested linear trends. Participants had a mean (SD) age of 53.2 (9.0) years and 53.1% were women. Migraine prevalence was 29.1% (including probable migraine). Individuals with migraine had slightly higher median serum Cd levels than controls [0.050&#xa0;&#xb5;g/L (IQR 0.035-0.077) vs. 0.048&#xa0;&#xb5;g/L (0.035-0.066); p&#x2009;=&#x2009;0.021], although smoking exposure scores did not differ between groups. Smoking exposure showed a strong positive association with serum Cd concentrations (p-trend&#x2009;<&#x2009;0.001). Participants in the highest Cd quintile had greater odds of migraine [aOR 1.51 (95% CI 1.09-2.08), p&#x2009;=&#x2009;0.011] after adjustment for smoking exposure and sociodemographic and clinical confounders. Sex-stratified analysis yielded even stronger associations among males [aOR 1.84 (95% CI 1.07-3.16), p&#x2009;=&#x2009;0.027]. However, in the sensitivity analysis including definite migraine cases only, this association was no longer significant [aOR: 1.14 (0.71, 1.83), p&#x2009;=&#x2009;0.579]. Main findings suggest that Cd exposure from smoking may contribute to migraine occurrence, particularly in males. However, other sources of Cd that could influence migraine should not be disregarded, and future investigation in this field is warranted.

Cadmium

Prenatal exposure to particulate matter (PM) and autism spectrum disorder (ASD) among children: a systematic review and meta-analysis.

The global surge in Autism Spectrum Disorder (ASD) cases, coupled with evidence linking prenatal Particulate Matter (PM) exposure to developmental disruption, demands a comprehensive review to design targeted health interventions. This systematic review and meta-analysis aim to evaluate the strength and consistency of evidence linking prenatal PM exposure to ASD across studies, quantifying this relation to identify actionable environmental risk thresholds. This study employed PRISMA protocols to systematically extract and evaluate evidence from PubMed, Web of Science, Scopus, and ScienceDirect (2010-2024), and screened 4,013 articles to identify qualified case-control and cohort studies (n=29). Data synthesis employed random-effects modeling, accompanied by comprehensive assessment through I2 statistics, Q-tests, funnel plots, Duval and Tweedie's trim-and-fill analysis, and Egger's regression, to ensure validity. A meta-analysis of 16&#xa0;case-control studies revealed a 34&#x202f;% increased risk of ASD associated with prenatal PM exposure (pooled OR=1.34; 95&#x202f;% CI: 1.13-1.54), despite substantial between-study heterogeneity (I2=94.02&#x202f;%, p<0.001). Publication bias was not significant (Egger's test p value=0.114). Critical trimester-specific analysis uncovered that third-trimester exposure significantly increased ASD risk (OR=1.17; 95&#x202f;% CI: 1.01-1.34), while first-trimester (OR=1.02; 95&#x202f;% CI: 0.92-1.11; I2=49.18&#x202f;%, p<0.10) and second-trimester exposures (OR=1.13; 95&#x202f;% CI: 0.88-1.38; I2=92.59&#x202f;%, p<0.001) showed non-significant associations. This review identified prenatal and early life exposure to PM as a risk factor for ASD, indicating a trimester-specific vulnerability. It highlighted the necessity of focused air quality interventions and targeted guidance to reduce prenatal PM exposure to alleviate ASD risk during the critical-window.

Child

Safety, pharmacokinetics and pharmacodynamics of TQC3721, an innovative, dual PDE3 and PDE4 inhibitor, in healthy subjects and patients with chronic obstructive pulmonary disease: Randomised, double-blind, placebo-controlled phase I and IIa clinical trials.

BACKGROUND AND PURPOSE: TQC3721 is a novel inhaled dual phosphodiesterase (PDE3/4) inhibitor designed to provide bronchodilation and anti-inflammatory effects for chronic obstructive pulmonary disease (COPD). EXPERIMENTAL APPROACH: First-in-human randomised, double-blind, placebo-controlled phase I (SAD: 0.2 to 24&#x2009;mg single dose; MAD: 12&#x2009;mg once daily (QD) for 7&#x2009;days in healthy subjects) and phase IIa studies (0.75 to 6&#x2009;mg once or twice daily for 4&#x2009;weeks in moderate-to-severe patients with COPD) were conducted. Primary outcomes included safety, pharmacokinetics (PKs) and pharmacodynamics (PDs), change from baseline of forced expiratory volume in the first second [FEV1], and FEV1 at 12 and 24&#x2009;h post-dose on days 1 and 28. KEY RESULTS: TQC3721 was rapidly absorbed (median Tmax of 0.25 to 0.5&#x2009;h), mainly by pulmonary absorption rather than gastrointestinal absorption, along with low systemic exposure and lack of significant accumulation. TQC3721 demonstrated favourable safety profiles in healthy subjects and patients with COPD. In patients with COPD, TQC3721 produced rapid and outstanding bronchodilation effect sustained over 12&#x2009;h post-administration, with FEV1 peaking at approximately 2&#x2009;h post-dose and returning to baseline levels by 12&#x2009;h, which supports a twice-daily dosing regimen for the future, and peak FEV&#x2081; improvements ranging from 186 to 272&#x2009;ml across dose groups after 4&#x2009;weeks of treatment. Moreover, twice-daily 3 and 6&#x2009;mg regimens were recommended for further clinical study. CONCLUSIONS AND IMPLICATIONS: Pharmacokinetic features, significant bronchodilation effects and overall favourable safety characteristics support further clinical development of TQC3721 as a potential dual-mechanism therapy for COPD.

Adult

Effectiveness of a digi-physical tool and working method for paediatric obesity treatment in Abu Dhabi: a non-inferiority intervention study using an external historical comparator.

BACKGROUND: Effective paediatric obesity treatment requires high intensity, scalable interventions. A digi-physical tool for paediatric obesity treatment has shown positive results in Stockholm, Sweden. This study evaluates whether the same treatment method is effective in a different cultural setting. METHODS: This non-inferiority intervention study, using an external historical comparator, included 60 consecutively recruited children aged 6-15.9 years with obesity who initiated treatment at Sheikh Shakhbout Medical City in Abu Dhabi between June and December 2023. Patients were treated with Evira, a digi-physical tool and working method enabling high intensity individualized care, real-time monitoring, and interactive patient-clinician communication. The primary outcome was BMI z-score change at 26 weeks. Non-inferiority was assessed using a predefined margin of 0.10 BMI z-score, with outcomes compared to a prior published trial in Stockholm (n&#x2009;=&#x2009;107). RESULTS: A total of 112 children were included in the analysis (Abu Dhabi cohort, n&#x2009;=&#x2009;35; Stockholm cohort, n&#x2009;=&#x2009;77). The adjusted mean change in BMI z-score was -&#x2009;0.20 (95% CI: -&#x2009;0.28, -&#x2009;0.12) in the Abu Dhabi cohort and -&#x2009;0.20 (- 0.26, -&#x2009;0.14) in the Stockholm cohort (p&#x2009;=&#x2009;0.88). Non-inferiority was confirmed, (predefined margin 0.10 was not exceeded). A clinically significant BMI z-score reduction (&#x2265;&#x2009;0.20 units) was achieved by 45.7% of participants in Abu Dhabi and 36.4% in Stockholm (p&#x2009;=&#x2009;0.35). Non-retention rates at 26 weeks were 41.7% vs. 28.0%, respectively (p&#x2009;=&#x2009;0.07). CONCLUSIONS: The findings provide promising evidence that treatment outcomes achieved with the digi-physical treatment tool were comparable in the Abu Dhabi and Stockholm cohorts, supporting its feasibility in a second cultural and healthcare setting.

Humans

Communication crossroads: Exploring generational dynamics in nursing from the bedside to the boardroom.

Nurses have up to four times more patient contact than physicians, positioning them as central drivers of communication in health care. Effective communication directly influences patient outcomes, teamwork, staff engagement, and the overall care experience. Today's nurses operate within a highly diverse environment that includes four generations in the workforce and up to eight generations of patients, each with distinct values, expectations, and communication preferences. This article examines how generational differences shape communication across three key relational domains: peer-to-peer, nurse-to-patient, and nurse-to-leader interactions, and offers insights to strengthen collaboration, engagement, and quality of care.

Humans

Effects of Time-Based and Distance-Based Repeated Sprint Training on Physical and Physiological Adaptations in Collegiate Basketball Players.

PURPOSE: This study aimed to compare the effects of time-based (TB) and distance-based (DB) repeated-sprint training (RST) on athletic performance adaptations in collegiate basketball players during preseason and to examine whether the 2 training prescriptions produce different levels of homogeneity in the magnitude of individual adaptations. METHODS: Thirty young male basketball players (age = 21.3 [1.4]&#xa0;y) were randomly and equally assigned to 3 groups (n = 10): DB-RST, TB-RST, and an active control group. Participants completed a 7-week RST program performed 3 times per week, consisting of 4 sets of 4 to 9 repetitions per session. The DB-RST group completed each sprint by covering a fixed 35-m distance, whereas the TB-RST group performed each sprint maximally for a fixed 5-second duration. Performance assessments including countermovement vertical jump, 20-m sprint, Illinois change-of-direction speed, reactive strength index, Wingate anaerobic power, and cardiorespiratory fitness were conducted before and after the 7-week training period. RESULTS: Both training groups demonstrated significant performance improvements over the 7-week intervention and relative to the control group (P < .05). Similar gains were observed in the magnitude of adaptations in the countermovement vertical jump, 20-m sprint, Illinois change-of-direction speed, and reactive strength index for the DB-RST and TB-RST groups. Interestingly, the TB-RST group showed more gains than the DB-RST in the magnitude of adaptations in the peak and mean power outputs, as well as cardiorespiratory fitness. Moreover, the TB-RST group showed lower intersubject variability in adaptive responses across the measured performance outcomes following the training intervention. CONCLUSION: Our findings indicate that RST effectively enhances the performance of basketball players, and that implementing a TB-RST protocol is more effective than a DB-RST approach for producing greater adaptations in physiological variables-specifically anaerobic power output and cardiorespiratory fitness-over the 7-week preseason period.

Humans

Dual-Reporter Gene-Based Multimodal Imaging for Tracking Mesenchymal Stem Cells in Diabetic Skin Wound Repair.

BACKGROUND: Diabetic foot ulcer (DFU) is a clinically challenging complication characterized by poor healing outcomes, and conventional therapies provide limited benefit. Mesenchymal stem cell (MSC) transplantation offers a promising strategy for DFU repair. However, the low survival of transplanted MSCs in the hostile wound microenvironment, coupled with the lack of real-time, non-invasive methods to track these cells in vivo, severely hampers their therapeutic efficacy and clinical translation. METHODS: We engineered MSCs to co-express a dual reporter system comprising near-infrared fluorescent protein (iRFP) and ferritin heavy chain (FTH1). These modified cells were then integrated with a fibrin glue (FG) scaffold to create a unified platform that supports both multimodal imaging and therapeutic function within skin wounds. First, FTH1 overexpression enhances the antioxidant capacity of MSCs, while the FG scaffold provides structural support; this combination enhances cell survival and retention. Second, the iRFP/FTH1 dual reporter enables near-infrared fluorescence imaging and MRI-based localization, establishing a multimodal platform for real-time cell tracking. RESULTS: In a full-thickness skin defect model in diabetic mice, multimodal imaging revealed that transplanted cells persisted in the wound area for approximately seven days. Treatment with iRFP/FTH1-MSCs/FG significantly accelerated wound closure and promoted hair follicle regeneration and angiogenesis. Additionally, local iron deposition resulting from FTH1 expression enhanced fibroblast migration and collagen synthesis, further facilitating extracellular matrix remodeling. Mechanistic studies demonstrated that this therapy drives macrophage polarization toward the anti-inflammatory M2 phenotype and activates the PI3K-AKT-VEGF signaling pathway. These complementary effects synergistically enhance tissue regeneration and systematically improve diabetic wound healing. CONCLUSIONS: Collectively, this multimodal stem cell-scaffold system effectively integrates dynamic cell tracking with stem cell therapy during skin wound repair. It addresses a critical technical gap in visualizing stem cells within the wound microenvironment and provides valuable methodological and theoretical foundations for optimizing regenerative strategies for diabetic skin wounds.

Animals

Long-term motor outcomes after parent-administered early physiotherapy in children born very preterm.

OBJECTIVE: This observational follow-up study investigated whether early parent-administered physiotherapy during the neonatal period was associated with motor outcomes in childhood, and compared these outcomes between two preterm groups and a term-born control group. STUDY DESIGN: This is a follow-up of a pragmatic randomised controlled trial that initially included 153 infants born very preterm (&#x2264;32&#xa0;weeks' gestation), randomised to either early parent-administered physiotherapy or standard care, between 34 and 37&#xa0;weeks' gestation. At 7-10&#xa0;years, motor outcomes were assessed in 92 children (intervention, n&#xa0;=&#xa0;43; standard care, n&#xa0;=&#xa0;49) and in 83 term-born controls. The primary outcome was the Movement Assessment Battery for Children-Second Edition (MABC-2). Group differences were analysed using linear mixed models adjusted for age, sex, and parental education. Odds ratios (ORs) were calculated for scores &#x2264;5th and&#xa0;&#x2264;&#xa0;15th percentiles to estimate the likelihood of having or being at risk for movement difficulties. RESULTS: Mean MABC-2 total score was 9.0 (SD3.0) in the intervention group, 9.6 (SD3.0) in the standard care group, and 10.8 (SD2.9) in the control group. Adjusted mean difference between the intervention and the standard care groups did not differ but both the intervention and standard care groups had lower scores than the control group (-1.2; 95% CI: -2.3 to -0.2 and -0.6; 95% CI: -1.6 to 0.3, respectively). Adjusted ORs for scoring &#x2264;5th or &#x2264;15th percentile did not differ in either preterm group compared with the control group. CONCLUSION: At 7-10&#xa0;years, motor outcomes did not differ between children born very preterm who received three-week parent-administered physiotherapy and those who received standard care during the neonatal period. However, both preterm groups had lower motor scores than term-born peers.

Humans

Visualizing the future: impact of holographic visualization on teaching minimally invasive veneer preparation: a randomized controlled trial.

BACKGROUND: Minimally invasive veneer preparation in prosthodontic education requires advanced spatial understanding and psychomotor precision. Although immersive technologies are increasingly used in dental education, evidence regarding the educational effectiveness of holographic visualization in prosthodontics remains limited. This randomized controlled trial evaluated the impact of holographic visualization on preparation quality and student-reported educational outcomes during preclinical training in minimally invasive veneer preparation. METHODS: Sixty undergraduate dental students were randomly assigned to receive either conventional two-dimensional photographic visualization (n&#x2009;=&#x2009;30) or holographic three-dimensional visualization (n&#x2009;=&#x2009;30). Following a standardized calibration session and baseline preparation, participants performed a second veneer preparation after exposure to the assigned visualization modality. Preparations were independently assessed by two blinded evaluators using a predefined scoring rubric. Within-group changes were analysed using Wilcoxon signed-rank tests, and between-group differences were assessed using analysis of covariance adjusted for baseline performance. Student-reported outcomes were compared using Mann-Whitney U tests with false discovery rate correction. RESULTS: Both groups showed significant improvements in preparation quality from baseline to post-intervention (both p&#x2009;<&#x2009;0.001). However, no significant between-group differences were observed (adjusted mean difference: 0.60 points; 95% confidence interval: -0.48 to 1.67; p&#x2009;=&#x2009;0.269). Overall student-reported outcomes were comparable between groups. Spatial understanding showed the largest between-group effect in favour of holographic visualization, although this difference was not significant after correction for multiple comparisons. Holographic visualization was highly accepted by students, and 70% supported its future integration into dental education. CONCLUSIONS: Although holographic visualization did not significantly improve immediate preparation quality compared with conventional two-dimensional photographs, it was highly accepted by students and showed the largest observed effect for perceived spatial understanding. These findings suggest that holographic visualization may primarily support spatial understanding and represent a valuable adjunct for teaching complex three-dimensional concepts in preclinical prosthodontic education. TRIAL REGISTRATION: German Clinical Trials Register (DRKS), DRKS00040713, prospectively registered on 22 June 2026.

Humans

Comparing the Effects of Push and Hold Isometric Training on Strength and Musculotendinous Adaptations: A Within-Subject Randomized Controlled Trial.

Lum, D, Oranchuk, DJ, Chen, SE, and Kong, PW. Comparing the effects of push and hold isometric training on strength and musculotendinous adaptations: A within-subject randomized controlled trial. J Strength Cond Res 40(9): 1050-1058, 2026-Despite recent interest in delineating pushing (PIMA) and holding (HIMA) isometric muscle actions, training-induced adaptations have not been examined. As such, we compared the strength and morphological adaptations between PIMA and HIMA training. Twenty limbs across 10 adults (5 men, 5 women, age: 31.4 &#xb1; 6.5 years) were randomly assigned to PIMA or HIMA conditions and underwent 12 training sessions over 6 weeks. PIMA required subjects to exert force against a fixed lever while the HIMA limb maintained a set joint angle while resisting an isotonic lever. During each contraction, subjects had to exert force at 70% of maximal voluntary contraction for 20 seconds at an 80&#xb0; knee angle, for 4-6 repetitions. Subjects completed isometric, concentric, and eccentric knee extension assessments for both limbs before and after the intervention. Pre- and postintervention ultrasound scans were performed to determine quadriceps muscle architecture and patellar tendon thickness. Increased isometric torque was found following both conditions (p < 0.05, g = 0.30-0.36), while concentric (p < 0.05, g = 0.31) and eccentric (p < 0.01, g = 0.50) torque only increased following PIMA. Both conditions increased muscle thickness (p < 0.05, g = 0.27-0.88) and vastus lateralis fascicle length (p < 0.05, g = 0.20-0.31). Only HIMA increased patellar tendon thickness (p < 0.05, g = 0.12). The increase in total quadriceps (p < 0.05, g = 0.46) and especially rectus femoris (p < 0.05, g = 1.44) thickness was greater in HIMA. The results suggest that PIMA may be more effective at improving strength, while HIMA may be superior for inducing morphological adaptations. Larger sample sizes and more ecologically valid training programs are warranted to further elucidate potential differences between different isometric types.

Humans

Robust error-minimization in the genetic code across physicochemical metrics and variant codes: A graph-theoretic analysis in GF(2)6.

The standard genetic code reduces the impact of point mutations, but the robustness of this property across physicochemical metrics, naturally occurring variant codes, and codon-reassignment mechanisms remains incompletely quantified. Embedding the 64 codons in GF(2)6 represents the hypercube Q6 as a coordinate-dependent subgraph of the encoding-independent single-nucleotide mutation graph H(3,4), and enables continuous &#x3c1;-interpolation between the two. Under a quartet-pattern shuffle null (n=10,000), the standard code is significantly low-cost across four established, code-independent physicochemical distance metrics with partially overlapping content (Grant ham p=0.0062; Miyata p<0.001; Woese polar requirement p=0.003; Kyte-Doolittle hydropathy p=0.001), and the signal strengthens monotonically as &#x3c1; moves Q6&#x2192;H(3,4). A structure-aware sensitivity analysis under the alignment-derived ProtSub matrix (Jia & Jernigan 2021) yields the most extreme percentile of any measure tested (p=0.0004; all five p-values pass Bonferroni at &#x3b1;=0.05). Across the 27 NCBI translation tables, near-optimality is preserved: 11 of 12 informative-distance variants retain top-5% placement after BH-FDR correction. Natural codon reassignments avoid disrupting codon-family connectivity: under the encoding-independent H(3,4) adjacency, observed events are topology-breaking at relative risk 0.32 versus the candidate landscape (permutation p&#x2264;10-4). The H(3,4) result is stable by construction; the Q6 decomposition is representation-specific and fails to show depletion under 8 of 24 base-to-bit encodings, so we report H(3,4) as the primary test and Q6 as a sensitivity. Event-level conditional-logit modelling shows that topology avoidance and local physicochemical cost provide complementary, only weakly correlated signal (rs=0.15), and that topology adds explanatory value beyond physicochemistry under both Q6 and encoding-independent H(3,4) adjacency. Retrospective reanalysis of nine genome-recoding datasets is consistent with codon-family topology operating as an evolutionary-trajectory constraint distinct from acute engineering fitness. The contribution is the second axis: code evolution is jointly constrained by physicochemical smoothness and codon-family topological integrity, and these two constraints are partly independent.

Codon reassignment

Suppression of AAV-Delivered Transgene Expression Using Artificial MicroRNAs Delivered by an Alternative AAV Serotype.

Adeno-associated virus (AAV) gene transfer vectors mediate long-term expression in nondividing cells, an advantage for treating chronic disorders. However, current platforms lack a way to selectively shut down transgene expression if adverse effects arise. To create an "off switch," we hypothesized that incorporating unique artificial microRNA (amiRNA) target sequences into an AAV expression cassette would allow subsequent suppression of transgene expression using a second AAV vector encoding the cognate amiRNA. We introduced 22-nt sequences absent from human and mouse transcriptomes into the 3' untranslated region (UTR) of a therapeutic AAV cassette. To identify optimal amiRNAs, two tandem copies of each amiRNA were cloned into the 3'UTR of an mCherry reporter gene. In vitro assessment of six amiRNA/target pairs using a dual luciferase assay identified four amiRNAs that efficiently suppressed reporter expression. Cells cotransfected with target site 3 (TS3) and amiRNA-T3B showed the greatest reduction in luciferase activity (80%, p < 0.0001) and were selected for further study. The "off-switch" system was then evaluated using an AAV5 therapeutic vector expressing a recombinant humanized anti-IgE monoclonal antibody (AAV5-TBG-anti-IgE-TS3), designed for long-term suppression of allergen-induced reactions. Co-transfection of HEK293T cells with anti-IgE-TS3 and amiRNA-T3B significantly reduced anti-IgE mRNA and protein levels relative to a control amiRNA (p < 0.0001). In vivo testing in Balb/c mice (n = 5) involved intravenous administration of AAV5-anti-IgE-TS3 (3.2 &#xd7; 1010 gc), followed 4 weeks later by an AAVrh.10 amiRNA vector (AAVrh.10-TBG-amiRNA-T3B; 1 &#xd7; 1011 gc). Control mice receiving only the therapeutic vector expressed 18.4 &#xb1; 13.8 &#xb5;g/mL serum anti-IgE at 10 weeks. In contrast, mice receiving the amiRNA "off" vector showed marked suppression of anti-IgE (0.3 &#xb1; 0.15 &#xb5;g/mL, p < 0.0001). These findings provide proof-of-concept that AAV-delivered amiRNAs can selectively switch off transgene expression, offering a strategy to improve the safety of AAV-mediated gene therapies.

Dependovirus

Effect of Peer Comparison Feedback and Professional Norms on Vitamin D Testing and Generic Medication Prescribing.

BACKGROUND: Organization for Economic Cooperation and Development (OECD) estimates suggest that 20% of health care spending is wasteful or even harmful. Previous interventions have had limited success in discouraging low-value care in medical practice. METHODS: We conducted a nationwide randomized controlled trial among primary care physicians (PCPs) in Switzerland (November 2020-December 2021). We randomly assigned PCPs to one of three intervention groups related to low-value care (vitamin D testing, generic prescribing, or a cost intervention) or a control group. This article reports results for the vitamin D testing and generic prescribing interventions compared with the common control group. PCPs in the intervention groups received a personalized information letter combining professional norms and peer comparison feedback about the low-value service (either vitamin D testing or prescribing of nongeneric medications). Primary endpoints were (1) the number of vitamin D tests per 100 patients and (2) the share of generic medications prescribed. We estimated average treatment effects using linear regression and assessed effect heterogeneity with a causal forest. RESULTS: A total of 618 PCPs were randomly assigned to the vitamin D intervention, 597 to the generic prescribing intervention and 601 to the common control group. The intervention reduced average vitamin D testing by 3.66 tests per 100 patients (95% confidence interval [CI], -5.42 to -1.89; P<0.001). The intervention did not increase average generic medication prescribing (mean difference, +0.57 percentage points; 95% CI, -0.68 to +1.81 percentage points; P=0.37). Heterogeneity analysis suggested that reductions in vitamin D testing among physician subgroups ranged from one to seven per 100 patients and that higher baseline generic prescribing rates were associated with increases in generic substitution following the intervention. No increases in low-value care were seen among those physicians with low baseline levels. CONCLUSIONS: Peer comparison letters emphasizing professional norms reduced vitamin D testing but did not increase generic medication prescribing. (Funded by the Swiss National Science Foundation; AEA Randomized Controlled Trials Registry no., AEARCTR-0004747.).

Humans

Comparison of the Effects of Spinal Versus General Anesthesia on the Perioperative Intraocular Pressure: A prospective, randomized clinical trial.

OBJECTIVES: To evaluate the effects of spinal and general anesthesia on the intraocular pressure (IOP) in patients, who had lumbar spine and lower extremity orthopedic surgeries. METHODS: Sixty adult were randomly classified into Group spinal anesthesia (SA) and Group general anesthesia (GA). The IOP, mean systemic arterial pressure, and heart rhythm were measured at 6 pre-determined timepoints (T0: Baseline, T1: Before spinal procedure or anesthesia induction, T2: After injection with intrathecal or anesthesia induction, T3: 5th minutes (min) after spinal procedure or tracheal intubation, T4: 30th min intraoperative, T5: At the end of surgery, T6: 5th min after surgery or tracheal extubation in the operation room. RESULTS: The baseline IOP and IOP1 measurements during were not significantly different between the groups (SA = 14.28 &#xb1; 0.8 mmHg; GA = 14.62 &#xb1; 0.9 mmHg, p = 0.923; and IOP1: SA = 15.83 &#xb1; 0.9 mmHg; GA = 15.88 &#xb1; 0.9 mmHg, p = 0.929). The most significant decrease in IOP in both groups was recorded at T2 (SA: 12.37 &#xb1; 0.6. GA: 12.24 &#xb1; 0.4, p < 0.001). The decrease in IOP2 was more significant in the GA group. The IOP3 was significantly higher in GA group after intubation (GA: 19.82 &#xb1; 1.2, SA: 12.86 &#xb1; 1.0)(p < 0.05). The IOP4 and IOP5 in the SA group were lower than those in the GA group. The IOP6 in both groups was higher (SA: 15.20 &#xb1; 0.8, GA: 16.50 &#xb1; 1.0) than the baseline IOP values, albeit not significant (p > 0.05). In prone position, IOP at the T4 and T5 timepoints were significantly higher than the initial values in both the SA and the GA groups; however, the increase in the GA group was more higher than that of the SA group. CONCLUSION: In intraoperative period, intraocular pressure may increase in both management of anesthesia, but this increase is higher in the general anesthesia group.

Humans