Search PubMedSearch

PubMed · 42598110

Comparison of the Effects of Spinal Versus General Anesthesia on the Perioperative Intraocular Pressure: A prospective, randomized clinical trial.

Abstract

OBJECTIVES: To evaluate the effects of spinal and general anesthesia on the intraocular pressure (IOP) in patients, who had lumbar spine and lower extremity orthopedic surgeries. METHODS: Sixty adult were randomly classified into Group spinal anesthesia (SA) and Group general anesthesia (GA). The IOP, mean systemic arterial pressure, and heart rhythm were measured at 6 pre-determined timepoints (T0: Baseline, T1: Before spinal procedure or anesthesia induction, T2: After injection with intrathecal or anesthesia induction, T3: 5th minutes (min) after spinal procedure or tracheal intubation, T4: 30th min intraoperative, T5: At the end of surgery, T6: 5th min after surgery or tracheal extubation in the operation room. RESULTS: The baseline IOP and IOP1 measurements during were not significantly different between the groups (SA = 14.28 &#xb1; 0.8 mmHg; GA = 14.62 &#xb1; 0.9 mmHg, p = 0.923; and IOP1: SA = 15.83 &#xb1; 0.9 mmHg; GA = 15.88 &#xb1; 0.9 mmHg, p = 0.929). The most significant decrease in IOP in both groups was recorded at T2 (SA: 12.37 &#xb1; 0.6. GA: 12.24 &#xb1; 0.4, p < 0.001). The decrease in IOP2 was more significant in the GA group. The IOP3 was significantly higher in GA group after intubation (GA: 19.82 &#xb1; 1.2, SA: 12.86 &#xb1; 1.0)(p < 0.05). The IOP4 and IOP5 in the SA group were lower than those in the GA group. The IOP6 in both groups was higher (SA: 15.20 &#xb1; 0.8, GA: 16.50 &#xb1; 1.0) than the baseline IOP values, albeit not significant (p > 0.05). In prone position, IOP at the T4 and T5 timepoints were significantly higher than the initial values in both the SA and the GA groups; however, the increase in the GA group was more higher than that of the SA group. CONCLUSION: In intraoperative period, intraocular pressure may increase in both management of anesthesia, but this increase is higher in the general anesthesia group.

Explore related subjects

Keep this discovery

BibTeXRIS

Muzaffer Gencer, Mehmet Yalva&#xe7;. 2026-08-06. Comparison of the Effects of Spinal Versus General Anesthesia on the Perioperative Intraocular Pressure: A prospective, randomized clinical trial.. https://doi.org/10.15537/1658-3175.8815

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Intraocular pressure-lowering effects of tetrahydrocannabinol drugs: a systematic review and meta-analysis.

PURPOSE: Within the past few decades, several studies have reported intraocular pressure (IOP)-lowering effects associated with tetrahydrocannabinol (THC) compounds as an alternative or complementary agent to conventional glaucoma therapies. The purpose of this study is to generate pooled estimates on the IOP-lowering effects of THC. METHODS: This systematic review and meta-analysis article was registered a priori on PROSPERO (CRD420251007916). MEDLINE, EMBASE, and Web of Science were searched for studies reporting IOP reduction following THC administration. Two reviewers independently performed screening, data extraction, and risk of bias assessments. A random-effects meta-analysis of mean differences was performed to estimate the overall pooled peak percentage reduction in IOP following THC administration, stratified by route of THC administration. RESULTS: Five studies were included, consisting of a total of 99 patients and 69 with THC exposure/intervention. Overall, the pooled peak percentage reduction in IOP after THC administration was 14.66% (95% CI: [3.38%, 25.93%]; p < 0.005). By route of THC delivery, the pooled peak percentage reduction in IOP was 33.27% (95% CI: [20.36%, 46.17%]; p < 0.0001) with the IV route. It was 10.65% (95% CI: [-7.60%, 28.89%]) with the oral route and 9.36% (95% CI: [-8.89%, 27.6%]) with the topical route. Four studies reported the peak percentage reduction in IOP after THC and control administration. From these studies, the pooled peak percentage reduction in IOP after THC was 6.88% (95% CI: [-9.56%, 23.33%]; p&#x202f;=&#x202f;0.41) and nonsignificantly different from control. CONCLUSIONS: Our study generated literature-pooled estimates of the overall and route-stratified peak percentage reduction in IOP following THC administration. THC significantly reduced IOP, although comparatively less significant to the control group.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans