Search PubMedSearch

SEARCH · Search PubMed

Results for “Robotic-assisted surgery”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

322 records · Page 4Linked to original sources

Animal-assisted therapy in pediatric urodynamics.

INTRODUCTION/BACKGROUND: Urodynamics (UDS) is associated with high levels of patient anxiety/discomfort. Children are often unable to complete UDS, with anesthesia needed to place catheters. Animal-assisted therapy (AAT) has been used in a variety of settings, but it has not been studied for UDS before. OBJECTIVE: To determine if AAT can increase success of completing UDS testing without anesthesia in children who were previously unable to perform UDS, along with decreasing distress levels. STUDY DESIGN: We performed a pilot case series of 7 patients (2 female, 5 male) aged 4-16 (mean 9.7) years who previously were unable to complete UDS awake, with AAT prior to and during the UDS procedure. A visual analog scale (VAS) was used to measure patient stress levels before and after AAT. RESULTS: We were able to successfully complete UDS testing with AAT in 6 of the 7 patients (85.7%) without the need for anesthesia. VAS scores decreased from before to after AAT (5.4-3.6, p = 0.020) but with discrepancy when compared to UDS success. DISCUSSION: Our study was the first to describe AAT during UDS. Our preliminary data found AAT to be feasible in UDS. Subjective distress may not correlate with procedural success. AAT in UDS may be more beneficial in certain populations, such as anxious children who previously were unable to tolerate UDS, and not in others such as severe neurodevelopmental conditions. Our study was limited by the small sample size, a single provider, single center, single therapy dog, inclusion of a specific population of patients, and no control group due to this being a pilot study. CONCLUSION: AAT for certain children undergoing UDS testing could help improve the ability to complete the testing without anesthesia. Further studies are needed to fully demonstrate its usefulness in UDS.

Humans

Improving Community-Based Care for Adolescents with ADHD: a Randomized Controlled Trial of Artificial Intelligence-Assisted Fidelity Supports.

Cognitive-behavioral treatments (CBTs) for adolescents with ADHD demonstrate promise of long-term effects on outcome. However, their implementation in routine care community clinics faces barriers that impact quantity, efficiency, and quality of delivery, as well as client outcomes. This study is a randomized controlled trial designed to evaluate the impact of an AI-assisted service delivery model on therapist implementation of Supporting Teens' Autonomy Daily (STAND), a CBT blended with Motivational Interviewing (MI) for adolescents with ADHD. Adolescents with ADHD (N = 51), who were clients at three community mental health agencies, received treatment from 23 therapists. There was randomization of adolescents and therapists to AI-assisted or standard implementation supports. In addition to standard supports (i.e., training, standard facilitation resources, technical assistance, case supervision), AI-assisted support package included digitized facilitation resources housed in a clinical dashboard (Care4), feedback on content fidelity, and AI-generated feedback on MI implementation quality. The AI-assisted group was associated with more efficient treatment delivery and lower number of appointments attended by the adolescent. There was also a significant decrement in MI quality over time in the AI-assisted group compared to the standard support group. Feedback in focus groups indicated that therapists perceived a task-oriented mindset to be associated with receipt of the AI-assisted support package, leading therapists to prioritize efficiency over relational aspects of therapy. Following the results of this trial, a future, larger RCT should examine the impact of the AI-assisted implementation model on mental health outcomes and cost savings to organizations, third party payers, and clients. Trial registration number: NCT05135065; https://www.clinicaltrials.gov ; Registered September 2021.

Humans

Hysteroscopic platelet-rich plasma and medically assisted reproduction outcomes: a systematic review and SWOT analysis.

BACKGROUND: Platelet-rich plasma (PRP) has been proposed as an adjuvant treatment in reproductive medicine. While most evidence refers to blind intrauterine instillation, subendometrial administration under hysteroscopic guidance allows targeted delivery under direct visualisation. This systematic review aimed to synthesise the available evidence on hysteroscopic PRP administration and its impact on clinical medically assisted reproduction (MAR) outcomes. METHODS: A systematic search was conducted from inception to December 2025 across major databases. Studies were included if they evaluated hysteroscopic PRP administration in women undergoing MAR, comparing reproductive outcomes between treated and control groups. RESULTS: Out of 142 records, 3 studies met the inclusion criteria. Study populations were heterogeneous and included women with refractory thin endometrium and/or a history of implantation failure. Hysteroscopic PRP administration protocols varied in timing, technique, and dosage. In a prospective case-control study, hysteroscopic intraendometrial PRP injection at a depth of 2-3 mm in the four uterine walls, using an ovum aspiration needle, on days 11-13 of the cycle prior to euploid frozen embryo transfer (ET), was associated with higher implantation (IR), clinical pregnancy (CPR), and live birth rates (LBR) compared with standard therapy. Conversely, no significant differences in CPR, miscarriage rate, or LBR were observed in an observational study evaluating a single intraendometrial PRP injection (35-40 mL, 2-3 mm depth), administered via endoscopic needle on days 6-8 of the menstrual cycle preceding frozen ET, alone or after electrical impulse therapy. A randomised controlled trial in women undergoing intrauterine insemination reported a significant improvement in CPR following hysteroscopic subendometrial PRP instillation in the four uterine walls (1.0 mL each). CONCLUSIONS: Current literature on hysteroscopic PRP administration in reproductive medicine is limited, and robust conclusions cannot yet be drawn. Well-designed randomised controlled trials with standardised protocols are needed to clarify its clinical role.

Humans

AI echo INSIGHT study: A prospective blinded randomized trial of artificial intelligence echocardiogram interpretation.

BACKGROUND: Transthoracic echocardiography (TTE) is the most commonly performed cardiac imaging modality with over 30 million studies annually. Demand for timely expert interpretation continues to outpace capacity, creating diagnostic delays and inter-observer variability that impact patient care. Recent research has suggested computer vision artificial intelligence (AI) models can generate accurate preliminary comprehensive TTE reports, however, prospective evaluation is needed to determine whether AI-assisted TTE interpretation can improve clinician efficiency while preserving diagnostic accuracy. METHODS: AI ECHO INSIGHT is a prospective randomized blinded clinical trial conducted at Kaiser Permanente Northern California that will evaluate 1200 historical TTE studies (1000 consecutive unselected studies plus 200 with moderate or greater valvular disease) interpreted using three workflows: (1) AI-generated preliminary report finalized by a blinded cardiologist (AI-assisted); (2) cardiologist-generated preliminary report finalized by a blinded cardiologist (cardiologist-assisted); and (3) sonographer-generated preliminary report finalized by a blinded cardiologist (sonographer-assisted). The primary outcome is the rate of substantial change between preliminary and final reports, comparing the AI-assisted workflow to the pooled cardiologist-assisted and sonographer-assisted workflows. Secondary outcomes include cardiologist interpretation time for report finalization, superiority testing for diagnostic accuracy, and reporting consistency. CONCLUSION: AI ECHO INSIGHT is a prospective randomized blinded clinical trial evaluating the clinical impact of AI-assisted TTE interpretation on diagnostic accuracy, cardiologist efficiency, and reporting consistency in real-world echocardiography workflows. TRIAL REGISTRATION: ClinicalTrials.gov registration number NCT07229300.

Humans

Development and Crossover Evaluation of an Artificial Intelligence-Assisted System for Solid Pancreatic Lesion Detection and Pancreatic Parenchyma Recognition in Endoscopic Ultrasonography (With Video).

BACKGROUND AND STUDY AIMS: Pancreatobiliary endoscopic ultrasonography (EUS) is technically demanding, and supervised training opportunities are limited. We developed an artificial intelligence (AI) overlay system for detecting solid pancreatic lesions (SPL) and recognizing pancreatic parenchyma (PP) and evaluated its effect on reader performance. PATIENTS AND METHODS: Across six centers, two deep learning-based models were trained using expert-annotated EUS frames. We then conducted a randomized, two-sequence, two-period crossover reader study in which eight endosonographers (five novices and three experts) interpreted image sets with and without AI assistance. The primary endpoint was superiority of sensitivity for SPL detection among novices; key secondary endpoints included specificity and PP recognition. RESULTS: From 118 patients, 120 SPL-positive/negative image sets and 160 PP-positive/negative image sets were constructed. Among novices, AI assistance improved SPL detection sensitivity (88.7% vs. 76.8%, p&#x2009;<&#x2009;0.001) and accuracy (86.4% vs. 78.7%), while specificity met the predefined noninferiority criterion (84.2% vs. 80.5%, p&#x2009;<&#x2009;0.001). For PP recognition, sensitivity increased numerically (86.3% vs. 83.3%) but did not meet the predefined superiority criterion (p&#x2009;=&#x2009;0.095); specificity met the noninferiority criterion (87.8% vs. 81.0%), and accuracy increased from 82.1% to 87.0%. Among experts, sensitivity was maintained for both tasks, whereas specificity increased with AI assistance. CONCLUSIONS: AI assistance improved SPL detection among novice endosonographers. For PP recognition, sensitivity increased without reaching statistical superiority, whereas specificity met the predefined noninferiority criterion. These findings support a potential adjunctive role for AI in EUS interpretation.

Humans

Artificial intelligence-assisted detection and optical differentiation of colorectal lesions in Lynch syndrome surveillance (CADLY2): a multicentre, open-label, randomised controlled superiority trial.

BACKGROUND: Artificial intelligence (AI)-based computer-aided detection (CADe) systems improve adenoma detection in average-risk colorectal cancer screening. Meanwhile, evidence in Lynch syndrome surveillance is sparse and inconsistent. We assessed the effect of CADe on adenoma detection during Lynch syndrome surveillance. Computer-aided optical diagnosis (CADx) performance for optical differentiation of colorectal lesions was evaluated as a secondary aim. METHODS: CADLY2 was an international, multicentre, open-label, randomised controlled superiority trial at nine specialised hereditary cancer surveillance centres in Belgium, Germany, the Netherlands, and Spain. Adults aged 18 years or older with genetically confirmed Lynch syndrome scheduled for surveillance colonoscopy were randomly assigned (1:1) to high-definition white-light (HD-WL) colonoscopy alone or to HD-WL colonoscopy with computer-aided assistance from CAD EYE (Fujifilm, Tokyo, Japan). CAD EYE was used for CADe during withdrawal and for CADx after lesion detection. Randomisation was done centrally through a secure web-based system using Pocock's minimisation algorithm with a stochastic component and was stratified by centre, sex, previous colorectal cancer, underlying pathogenic variant, and interval since previous colonoscopy. Allocation concealment was ensured through the centralised web-based system. Patients were masked to group allocation until the start of withdrawal in procedures with mild sedation, or until completion of the procedure in procedures with propofol-based sedation. Endoscopists were not masked. The primary outcome was adenoma detection rate, defined as the proportion of patients with at least one histopathologically confirmed adenoma, analysed in the full analysis set (defined as all randomly allocated patients with available data for the primary outcome). The diagnostic performance of the CADx system was evaluated as a secondary outcome. The safety analysis set comprised all randomly allocated patients who underwent a study colonoscopy. This study is registered with the German Clinical Trials Register, DRKS00030695, and is completed. FINDINGS: Between May 9, 2023, and Oct 30, 2025, 757 patients were randomly allocated to HD-WL colonoscopy (377 patients) or to AI-assisted colonoscopy (380 patients); 733 patients were included in the full analysis set (369 HD-WL and 364 AI-assisted). The median age was 49 years (IQR 38-59) in the HD-WL group and 50 years (38-59) in the AI-assisted group; 213 (58%) were female and 156 (42%) male in the HD-WL group, and 207 (57%) were female and 157 (43%) male in the AI-assisted group. The adenoma detection rate was 30&#xb7;9% (114 of 369 patients) with HD-WL versus 33&#xb7;8% (123 of 364 patients) with CADe assistance (odds ratio 1&#xb7;14 [95% CI 0&#xb7;83-1&#xb7;57], p=0&#xb7;41). For CADx differentiation of neoplastic versus non-neoplastic lesions in the paired lesion-level analysis, with histopathology as the reference standard and sessile serrated lesions and traditional serrated adenomas classified as non-neoplastic, CADx sensitivity was 85&#xb7;9% (95% CI 82&#xb7;0-89&#xb7;1) and specificity was 91&#xb7;4% (89&#xb7;4-93&#xb7;0). Three adverse events occurred in the AI-assisted group: two mild post-polypectomy bleedings and one serious pulmonary embolism or deep venous thrombosis unrelated to the procedure. No adverse events occurred in the HD-WL group. INTERPRETATION: CADe-assisted colonoscopy did not show the absolute improvement in adenoma detection rate that was assumed in the prespecified sample-size calculation. CADx did not clearly improve lesion differentiation beyond expert optical diagnosis in expert Lynch syndrome surveillance settings. FUNDING: Third-party research funding of the National Center for Hereditary Tumor Syndromes, University Hospital Bonn.

Humans

Hydrodissection-assisted laparoscopic orchiopexy utilizing needle grasper for palpable undescended testes: Clinical efficacy analysis.

OBJECTIVE: Laparoscopic orchiopexy has emerged as a viable alternative for the treatment of palpable undescended testis (UDT). This study aims to evaluate the feasibility and efficacy of needle-grasper hydrodissection-assisted laparoscopic orchiopexy (NHLO) in comparison to conventional laparoscopic orchiopexy (CLO) for palpable UDT. METHODS: A cohort of 96 patients diagnosed with palpable UDT, admitted between January 2020 and April 2024, was included in this study. Among these, 54 patients underwent NHLO, while 42 patients were treated with CLO. In the NHLO procedure, normal saline was injected into the retroperitoneal space to create a hydrodissection barrier, facilitating the separation and protection of the vas deferens and spermatic cord. The vas deferens and spermatic cord were meticulously dissected following the principles of integrity and minimal tissue trauma. Outcome measures included final testicular position, testicular volume growth, testicular atrophy, success rate, and postoperative complications. RESULTS: No significant differences were observed between the NHLO and CLO groups in terms of age, laterality, operative time (NHLO: 38-46 min; CLO: 39-48 min), or complication rates (NHLO: 1.9 %; CLO: 0.0 %). At follow-up, all patients in both groups exhibited palpable testes in satisfactory scrotal positions. Notably, no visible abdominal scarring was observed in the NHLO group, whereas there were two noticeable scars on the abdomen in CLO. CONCLUSION: Needle-grasper hydrodissection-assisted laparoscopic orchiopexy is a safe, effective, and minimally invasive technique that provides optimal protection of the vas deferens and spermatic cord while achieving excellent cosmetic outcomes.

Humans

Machine learning-assisted Mn-N-C nanozyme colorimetric sensor array for trace-level detection of biogenic amines in meat.

Accurate detection of biogenic amines (BAs) in meat remains challenging due to their high structural similarity and co-occurrence. Herein, an Mn-N-C nanozyme was synthesized via a metal-organic framework confined pyrolysis strategy, possessing excellent oxidase (OXD)- and peroxidase (POD)-like activities. The dual enzyme-like activity showed Km values of 0.1584&#xa0;mM (OXD) and 0.1498&#xa0;mM (POD), respectively, in detection system. Leveraging these properties, a colorimetric sensor array was constructed, enabling the detection of four representative BAs within a concentration range of 2-10&#xa0;ppm with 100% classification accuracy. In addition, a concentration independent recognition model based on an artificial neural network was developed to address signal nonlinearity interference in meat. The integrated system achieved accurate trace-level identification of BAs in perishable fish, pork, and chicken, demonstrating its applicability for early-stage BAs monitoring and quality deterioration warning during storage and transportation.

Biogenic Amines

An AI-assisted Clinical Decision Support System for Green Classification of Cystocele on Dynamic Transperineal Ultrasound.

Green classification of cystocele on dynamic transperineal ultrasound (TPUS) remains operator-dependent because it requires manual frame selection and landmark-based assessment of the Valsalva maneuver. We developed a workflow-oriented AI-assisted clinical decision support system for automated urethrovesical junction localization and dynamic Green classification and prospectively evaluated its standalone and reader-support performance. This diagnostic accuracy and reader study included 881 patients from a tertiary referral hospital, comprising a retrospective development cohort (n&#x2009;=&#x2009;688) and an independent prospective test cohort (n&#x2009;=&#x2009;193). A nested subset of 67 prospective patients was used for a reader study involving two junior and two intermediate radiologists under unaided and AI-assisted conditions. In the complete prospective test cohort, Green-AttGRU achieved a macro-averaged AUC of 0.939 (95% CI, 0.897-0.971) and an overall accuracy of 0.902 (95% CI, 0.860-0.943). In the reader study, overall accuracy increased from 0.761 to 0.821 without AI to 0.851-0.881 with AI, while macro-F1 increased from 0.660 to 0.777 to 0.820-0.860. Overall inter-reader agreement increased from a Fleiss' &#x3ba; of 0.453 to 0.786, and pooled median interpretation time decreased from 26.7&#xa0;s to 9.9&#xa0;s. These findings support the preliminary feasibility of the system as a workflow-oriented decision-support tool for dynamic TPUS interpretation.

Humans

Immersive virtual reality-assisted anatomy training improves endotracheal intubation performance in simulation: a randomized controlled trial among Chinese non-anesthesiology residents.

INTRODUCTION: This study aimed to compare immersive virtual reality (IVR)-assisted versus conventional anatomy training for teaching endotracheal intubation (ETI) to novice non-anesthesiology residents enrolled in China's Standardized Residency Training program. METHODS: A total of 90 non-anesthesiology residents without prior ETI experience were randomly assigned to either an IVR group receiving IVR-assisted anatomy training (n&#x2009;=&#x2009;45) or a control group receiving conventional anatomy training (n&#x2009;=&#x2009;45). All participants underwent a standardized teaching protocol. The primary endpoint was residents' ETI performance on a simulator, assessed using both the Global Rating Scale (GRS) and a task-specific checklist. The secondary endpoints included changes in written multiple-choice question (MCQ) scores and residents' evaluations of the course. RESULTS: In practical ETI assessments on a manikin, the IVR group achieved significantly higher scores on the task-specific checklist than the control group (90.34&#x2009;&#xb1;&#x2009;2.89 vs. 87.20&#x2009;&#xb1;&#x2009;3.29; p&#x2009;<&#x2009;0.001), whereas GRS scores were comparable between groups. Both groups showed significant post-training improvement in knowledge scores (p&#x2009;<&#x2009;0.001), with the IVR group showing a greater gain in theoretical knowledge (54.0% vs. 36.3%; p&#x2009;<&#x2009;0.001). Participants in the IVR group also expressed a stronger preference for their training method (80.8%) and reported higher levels of motivation, confidence, and enjoyment (all p&#x2009;<&#x2009;0.05). CONCLUSION: IVR-assisted anatomy training enhances the effectiveness of ETI training for novice non-anesthesiology residents, offering an interactive, engaging, and reproducible approach within China's Standardized Residency Training framework.

Humans

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Vortex-assisted liquid-liquid microextraction based on natural deep eutectic solvents for the determination of pyrethroid pesticides in urine.

A novel, facile, and environmentally friendly analytical method was developed based on vortex-assisted liquid-liquid microextraction and high-performance liquid chromatography with diode-array detection for detecting pyrethroid pesticides (PPs) in urine. Natural deep eutectic solvents (NADESs) were prepared using plant essential oil-derived monoterpenoids (thymol, carvacrol, and menthol) combined with aromatic primary alcohols (benzyl alcohol, phenethyl alcohol, and phenylpropyl alcohol) as hydrogen bond donors and acceptors. These solvents served as environmentally benign extraction media, thereby avoiding the use of conventional volatile, toxic organic solvents. NADESs are naturally derived, easy to prepare, biodegradable, and environmentally friendly solvents. Hydrophobic and &#x3c0;-&#x3c0; interactions between the NADESs and PPs may contribute to enhancing the affinity of PPs toward the NADESs phase. Vortex technology, accelerating mass transfer between the sample and extractant phases, enables fast extraction of PPs. Under optimized conditions, the method achieved a low detection limit (0.002&#xa0;mg&#xa0;L-1), satisfactory precision with relative standard deviations (0.3%-2.4%), and acceptable recovery (80.7%-86.2%). The method demonstrated excellent performance in urine analysis and was feasible as a facile and green strategy for monitoring the content of PPs in biological matrices and assessing exposure risk.

Liquid Phase Microextraction

Ketamine assisted psychotherapy to reduce chronic neuropathic pain: A mixed-methods randomized pilot trial.

BACKGROUND: Intravenous ketamine can provide short-term analgesia in chronic neuropathic pain but benefits often wane after treatment. We conducted a randomized pilot trial to assess the feasibility of combining ketamine infusions with psychotherapy to inform future efficacy trials. METHODS: In this single-center, randomized, outcome-assessor-blinded pilot trial at a Canadian tertiary pain clinic, adults with moderate-to-severe chronic neuropathic pain were randomly assigned in 1:1:1 ratio to the ketamine, psychotherapy, or combined ketamine plus psychotherapy arm. Ketamine was delivered as three intravenous infusions over 16 weeks; psychotherapy consisted of 16 weekly cognitive behavioral therapy and mindfulness-based meditation sessions. The primary outcome was feasibility, assessed using prespecified progression criteria. Exploratory outcomes included changes in pain interference (PROMIS 6a T-score), pain intensity, mood, and qualitative interview findings at week 20 (ClinicalTrials.gov: NCT05639322). FINDINGS: Between October 23, 2023, and March 31, 2025, 30 participants were randomized, and 26 (87%) completed 20-week follow-up. Most feasibility criteria, including consent, retention, data completeness, and absence of study-related serious adverse events, were met; adherence targets were partially met. Exploratory pain outcomes showed numerical improvement across groups, with clinically meaningful reductions observed for pain interference and pain intensity. Sixty-four adverse events were recorded, mostly mild and in ketamine-containing groups; no serious study-related adverse events occurred. CONCLUSIONS: Combined ketamine and psychotherapy was feasible and acceptably safe in this pilot trial, supporting evaluation in a larger efficacy-powered study. FUNDING: The study was funded by the St. Michael's Hospital Innovation Fund, The Canadian Pain Society Early Investigator Award and the Physician Services Incorporation Early Career Researcher Award.

Humans

An RPA-assisted homogeneous electrochemical DNA sensor for on-site eDNA detection toward early warning of crown-of-thorns starfish outbreaks.

Crown-of-thorns starfish (COTS) outbreaks seriously threaten coral reef ecosystems, while conventional monitoring approaches are time-consuming and often lack sufficient sensitivity for early warning. Existing electrochemical DNA sensors usually require complex electrode-surface immobilization procedures, which can lead to uneven probe distribution, significant steric hindrance, and poor stability. Meanwhile, the low concentration of environmental DNA (eDNA) in marine environments further complicates detection. To overcome these challenges, this study developed a homogeneous electrochemical DNA sensor assisted by recombinase polymerase amplification (RPA) for COTS eDNA detection. Target DNA was first amplified by RPA, and the amplification products were then hybridized in solution with capture probe (CP)-modified magnetic beads (MB) and biotin-labeled signal probe (SP) to form sandwich-structured MB complexes. These complexes were subsequently magnetically enriched and immobilized on the electrode surface for electrochemical signal readout. Under optimized conditions, the sensor displayed a linear response to COTS genomic DNA from 3.77&#xa0;fg/&#x3bc;L to 1&#xa0;ng/&#x3bc;L, with an LOD of 2.02&#xa0;fg/&#x3bc;L and an LOQ of 3.77&#xa0;fg/&#x3bc;L. The sensor was applied to Xisha Islands samples, and the results agreed with droplet digital PCR (ddPCR) (P&#xa0;>&#xa0;0.05), demonstrating its potential for sensitive and reliable on-site COTS eDNA detection.

Animals

Infertility treatment in women with epilepsy: A systematic review.

BACKGROUND: The impact of assisted reproductive technologies (ART) on seizure control in women with epilepsy remains incompletely understood. METHODS: A systematic review was conducted according to PRISMA guidelines. EMBASE, MEDLINE, CINAHL, Scopus, and the Cochrane Library were searched from inception to March 2025. Eligible studies included observational studies and case-based reports involving women undergoing infertility treatment. RESULTS: A total of 1216 publications were identified, of which four studies met the inclusion criteria, including case reports, a case series, and a cohort study. These studies included 16 women aged 25-46&#xa0;years undergoing infertility treatment, all but one of whom had epilepsy. Interventions involved in vitro fertilization (IVF), ovulation induction, and hormonal therapies. Patients were treated with a range of antiseizure medications (ASMs), including carbamazepine, clobazam, lamotrigine, levetiracetam, oxcarbazepine, valproate, and zonisamide, either as monotherapy or in combination. Seizure frequency was generally stable, with most patients maintaining baseline seizure control. Seizure exacerbations were uncommon and primarily associated with hormonal therapy and reduced ASM levels, particularly reduced lamotrigine levels. Reported events included breakthrough seizures in the setting of decreased lamotrigine concentrations, seizure clusters associated with follitropin beta, and a new-onset seizure following dehydroepiandrosterone exposure. Across studies, multiple ART attempts resulted in live births with different ASM regimens, as well as in patients not receiving ASMs. CONCLUSION: Available evidence suggests that ART is feasible in women with epilepsy, with most patients maintaining stable seizure control. Hormonal therapy may affect ASM pharmacokinetics and seizure threshold, thereby warranting close monitoring. Larger prospective studies are needed to better define ASM-specific effects and optimize care.

Humans

First insights into the role of evolutionary history in shaping venom composition of Vipera ammodytes.

Understanding intraspecific venom variation requires distinguishing the contributions of neutral population history from natural selection. This study aims to determine whether venom variation in Vipera ammodytes species complex is structured across eight phylogenetic groups. Despite a complex evolutionary history, venom composition did not differ among phylogenetic groups within the analytical framework used, suggesting that shared ancestry alone does not explain venom variation. Whether local adaptation to environmental conditions explains the observed variation remains an open question for future studies.

Animals

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

Clinical applications of digital twin technology in In Vitro Fertilisation.

BACKGROUND: Digital twin technology, originating from aerospace and manufacturing industries, has emerged as a transformative tool in healthcare. In vitro fertilisation (IVF) faces persistent challenges including suboptimal embryo selection, unpredictable treatment outcomes, and limited personalisation of protocols. Despite advances in assisted reproductive technology, existing literature exhibits fragmentation: artificial intelligence applications in embryo selection, ovarian stimulation, and endometrial assessment have been developed independently without systematic integration into comprehensive treatment frameworks. Digital twin technology offers unprecedented opportunities to create virtual replicas of biological systems, enabling real-time monitoring, predictive modelling, and personalised treatment strategies. AIM: This narrative review aims to critically examine the current applications of digital twin technology in IVF, evaluate its potential benefits and limitations, synthesize existing evidence into an integrative conceptual model, and identify future directions for implementation in reproductive medicine. METHOD: A comprehensive narrative review was conducted using PubMed, Scopus, Web of Science, and IEEE Xplore databases. A narrative review approach was selected over systematic review to accommodate the heterogeneity of evidence types in this emerging field, including theoretical frameworks, simulation studies, and proof-of-concept implementations that would be excluded from systematic reviews. Search terms included "digital twin," "IVF," "in vitro fertilisation," "assisted reproductive technology," "embryo selection," and "predictive modelling." Studies published between 2015 and 2025 were included, focusing on original research articles, systematic reviews, and proof-of-concept studies describing digital twin applications in reproductive medicine. RESULTS: Digital twin technology in IVF demonstrates significant potential across multiple domains including embryo development simulation, ovarian response prediction, endometrial receptivity modelling, and personalised stimulation protocols. Current applications integrate artificial intelligence, machine learning algorithms, time-lapse imaging, and omics data to create comprehensive virtual models. Early evidence suggests improvements in embryo selection accuracy, ovarian response prediction, and treatment protocol optimization, though large-scale randomized controlled trials remain limited. Implementation challenges include data integration complexity, computational requirements, regulatory considerations, and validation requirements. CONCLUSION: Digital twin technology represents a paradigm shift in IVF practice, offering personalised, predictive, and precision medicine approaches. This review synthesizes existing evidence to propose an integrative conceptual model for digital twin implementation across the IVF treatment spectrum, identifies critical knowledge gaps, and establishes research priorities to advance clinical translation. Despite current limitations, continued advancement promises improved success rates and patient outcomes.

Humans