Search PubMedSearch

SEARCH · Search PubMed

Results for “Enzyme-assisted extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

473 records · Page 4Linked to original sources

Sutureless versus renorrhaphy in robot-assisted off-clamp partial nephrectomy: a systematic review and meta-analysis.

BACKGROUND: The necessity of routine parenchymal renorrhaphy during off-clamp robot-assisted partial nephrectomy (RAPN) remains uncertain. This study aimed to compare perioperative, functional, safety, and oncological outcomes between sutureless and conventional renorrhaphy. METHODS: We conducted a systematic review and meta-analysis following PRISMA 2020 guidelines. Comparative studies evaluating sutureless versus conventional renorrhaphy during purely off-clamp RAPN were included. Trifecta achievement was the primary outcome. Random-effects models were used for pooled analyses, with subgroup analysis according to study design. RESULTS: Four studies involving 787 patients, including one randomized controlled trial (RCT) and three propensity score-matched (PSM) studies, were included. The overall pooled estimate showed no statistically significant difference in Trifecta achievement (RR 1.17, 95% CI 0.97-1.41), with substantial heterogeneity (I² = 86.5%). The PSM studies favored the sutureless approach (RR 1.26, 95% CI 1.05-1.52), whereas the RCT yielded an RR of 0.97 (95% CI 0.92-1.04) and met the prespecified noninferiority criterion without demonstrating superiority. The sutureless approach was associated with a smaller perioperative eGFR decline (MD - 3.89, 95% CI - 6.16 to - 1.62), while no significant difference was observed in eGFR at 3 months. No statistically significant differences were identified in major complications, blood transfusion, or positive surgical margins; urinary and vascular complications were sparsely reported. CONCLUSIONS: In selected patients undergoing purely off-clamp RAPN, randomized evidence supports the noninferiority of a strategy that omits routine parenchymal renorrhaphy while permitting clinically necessary selective repair, but does not demonstrate superiority. Favorable estimates from PSM studies remain vulnerable to intraoperative treatment-selection bias. Current evidence is insufficient to determine whether omission of renorrhaphy affects urinary complications, long-term renal function, or oncological outcomes. REGISTRATION: This systematic review was registered prospectively in PROSPERO (CRD420261435995).

Humans

Protein isolation markedly enhances in vitro digestibility, nutritional quality, and bioactivity of fungal mycelial proteins.

Fungal mycelial proteins are promising sustainable protein sources, yet their nutritional utilization is often limited by structural constraints. This study systematically evaluated the effects of protein isolation on the proteomic composition, gastrointestinal digestion behavior, amino acid utilization, and bioactivity of Pleurotus citrinopileatus mycelial proteins. Quantitative proteomics identified 3591 proteins, of which 3374 were shared between mycelial flour (PCMF) and protein isolate (PCMPI), indicating that PCMPI primarily represents the soluble proteome fraction. In vitro digestion revealed that PCMPI exhibited significantly higher digestibility (93.98%) than PCMF (42.98%) (p&#xa0;<&#xa0;0.05), reaching levels comparable to whey protein isolate. Enhanced enzymatic accessibility in PCMPI promoted rapid peptide generation during the gastric phase and efficient amino acid release during the intestinal phase, resulting in higher peptide (634.76&#xa0;mg/g) and free amino acid levels (341.69&#xa0;mg/g) at the digestion endpoint. Consequently, PCMPI achieved a balanced amino acid profile with a PDCAAS of 1.0. Moreover, its digestion products exhibited stronger antioxidant activity (IC&#x2085;&#x2080;&#xa0;=&#xa0;8.36&#xa0;mg/mL) and ACE inhibitory activity (IC&#x2085;&#x2080;&#xa0;=&#xa0;15.65&#xa0;mg/mL) compared with PCMF. Mechanistically, protein isolation disrupted the cell wall matrix, shifting digestion from a structure-limited to an accessibility-driven regime. Collectively, these findings demonstrate that protein isolation markedly enhances the digestibility, nutritional quality, and functional potential of mycelial proteins, supporting their application as high-value sustainable protein ingredients.

Digestion

Development and Crossover Evaluation of an Artificial Intelligence-Assisted System for Solid Pancreatic Lesion Detection and Pancreatic Parenchyma Recognition in Endoscopic Ultrasonography (With Video).

BACKGROUND AND STUDY AIMS: Pancreatobiliary endoscopic ultrasonography (EUS) is technically demanding, and supervised training opportunities are limited. We developed an artificial intelligence (AI) overlay system for detecting solid pancreatic lesions (SPL) and recognizing pancreatic parenchyma (PP) and evaluated its effect on reader performance. PATIENTS AND METHODS: Across six centers, two deep learning-based models were trained using expert-annotated EUS frames. We then conducted a randomized, two-sequence, two-period crossover reader study in which eight endosonographers (five novices and three experts) interpreted image sets with and without AI assistance. The primary endpoint was superiority of sensitivity for SPL detection among novices; key secondary endpoints included specificity and PP recognition. RESULTS: From 118 patients, 120 SPL-positive/negative image sets and 160 PP-positive/negative image sets were constructed. Among novices, AI assistance improved SPL detection sensitivity (88.7% vs. 76.8%, p&#x2009;<&#x2009;0.001) and accuracy (86.4% vs. 78.7%), while specificity met the predefined noninferiority criterion (84.2% vs. 80.5%, p&#x2009;<&#x2009;0.001). For PP recognition, sensitivity increased numerically (86.3% vs. 83.3%) but did not meet the predefined superiority criterion (p&#x2009;=&#x2009;0.095); specificity met the noninferiority criterion (87.8% vs. 81.0%), and accuracy increased from 82.1% to 87.0%. Among experts, sensitivity was maintained for both tasks, whereas specificity increased with AI assistance. CONCLUSIONS: AI assistance improved SPL detection among novice endosonographers. For PP recognition, sensitivity increased without reaching statistical superiority, whereas specificity met the predefined noninferiority criterion. These findings support a potential adjunctive role for AI in EUS interpretation.

Humans

Artificial intelligence-assisted detection and optical differentiation of colorectal lesions in Lynch syndrome surveillance (CADLY2): a multicentre, open-label, randomised controlled superiority trial.

BACKGROUND: Artificial intelligence (AI)-based computer-aided detection (CADe) systems improve adenoma detection in average-risk colorectal cancer screening. Meanwhile, evidence in Lynch syndrome surveillance is sparse and inconsistent. We assessed the effect of CADe on adenoma detection during Lynch syndrome surveillance. Computer-aided optical diagnosis (CADx) performance for optical differentiation of colorectal lesions was evaluated as a secondary aim. METHODS: CADLY2 was an international, multicentre, open-label, randomised controlled superiority trial at nine specialised hereditary cancer surveillance centres in Belgium, Germany, the Netherlands, and Spain. Adults aged 18 years or older with genetically confirmed Lynch syndrome scheduled for surveillance colonoscopy were randomly assigned (1:1) to high-definition white-light (HD-WL) colonoscopy alone or to HD-WL colonoscopy with computer-aided assistance from CAD EYE (Fujifilm, Tokyo, Japan). CAD EYE was used for CADe during withdrawal and for CADx after lesion detection. Randomisation was done centrally through a secure web-based system using Pocock's minimisation algorithm with a stochastic component and was stratified by centre, sex, previous colorectal cancer, underlying pathogenic variant, and interval since previous colonoscopy. Allocation concealment was ensured through the centralised web-based system. Patients were masked to group allocation until the start of withdrawal in procedures with mild sedation, or until completion of the procedure in procedures with propofol-based sedation. Endoscopists were not masked. The primary outcome was adenoma detection rate, defined as the proportion of patients with at least one histopathologically confirmed adenoma, analysed in the full analysis set (defined as all randomly allocated patients with available data for the primary outcome). The diagnostic performance of the CADx system was evaluated as a secondary outcome. The safety analysis set comprised all randomly allocated patients who underwent a study colonoscopy. This study is registered with the German Clinical Trials Register, DRKS00030695, and is completed. FINDINGS: Between May 9, 2023, and Oct 30, 2025, 757 patients were randomly allocated to HD-WL colonoscopy (377 patients) or to AI-assisted colonoscopy (380 patients); 733 patients were included in the full analysis set (369 HD-WL and 364 AI-assisted). The median age was 49 years (IQR 38-59) in the HD-WL group and 50 years (38-59) in the AI-assisted group; 213 (58%) were female and 156 (42%) male in the HD-WL group, and 207 (57%) were female and 157 (43%) male in the AI-assisted group. The adenoma detection rate was 30&#xb7;9% (114 of 369 patients) with HD-WL versus 33&#xb7;8% (123 of 364 patients) with CADe assistance (odds ratio 1&#xb7;14 [95% CI 0&#xb7;83-1&#xb7;57], p=0&#xb7;41). For CADx differentiation of neoplastic versus non-neoplastic lesions in the paired lesion-level analysis, with histopathology as the reference standard and sessile serrated lesions and traditional serrated adenomas classified as non-neoplastic, CADx sensitivity was 85&#xb7;9% (95% CI 82&#xb7;0-89&#xb7;1) and specificity was 91&#xb7;4% (89&#xb7;4-93&#xb7;0). Three adverse events occurred in the AI-assisted group: two mild post-polypectomy bleedings and one serious pulmonary embolism or deep venous thrombosis unrelated to the procedure. No adverse events occurred in the HD-WL group. INTERPRETATION: CADe-assisted colonoscopy did not show the absolute improvement in adenoma detection rate that was assumed in the prespecified sample-size calculation. CADx did not clearly improve lesion differentiation beyond expert optical diagnosis in expert Lynch syndrome surveillance settings. FUNDING: Third-party research funding of the National Center for Hereditary Tumor Syndromes, University Hospital Bonn.

Humans

Robot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis.

Robot-assisted percutaneous vascular intervention (R-PVI) has expanded beyond coronary procedures, but previous reviews were largely coronary-focused and observational. Recent randomized controlled trials (RCTs) warrant broader reassessment of R-PVI versus manual percutaneous vascular intervention (M-PVI) across vascular territories. PubMed, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials were searched from database inception to January 31, 2026, following PRISMA guidelines. RCTs and observational studies including &#x2265;10 adult patients in total were eligible. Comparative studies informed primary analyses, while single-arm studies provided supportive evidence. Primary outcomes were clinical success rate and major adverse cardiovascular/cerebrovascular events (MACE) rate. Secondary outcomes included mortality rate, technical success rate, procedural time metrics, contrast volume, and radiation exposure. Random-effects models were used. Forty studies were included: 3 RCTs, 10 comparative observational studies, and 27 single-arm observational studies, comprising 3,870 patients undergoing R-PVI and 1,142 undergoing M-PVI. Comparative analyses showed similar clinical success rates (RR 1.00, P = 0.46), MACE rates (RR 0.72, P = 0.43), and mortality. Single-arm pooled estimates for clinical and technical success were 98.76% and 96.09%, respectively. R-PVI prolonged total procedure time overall (MD 15.92&#xa0;min, P = 0.01), with consistent increases in the neurovascular, RCT, and non-RCT subgroups. Fluoroscopy time was also longer (MD 1.91&#xa0;min, P = 0.04), mainly in the RCT subgroup (MD 2.83&#xa0;min, P = 0.001). In contrast, intravascular intervention time was unchanged overall and in RCTs, but was prolonged in non-RCTs (MD 8.72&#xa0;min, P = 0.006). Operator radiation exposure was markedly reduced (MD -33.97 &#x3bc;Sv, P < 0.001), whereas patient radiation exposure and contrast volume were similar. R-PVI appears feasible and safe across selected vascular procedures. Its clearest benefit is reduced operator radiation exposure, whereas lower whole-procedure efficiency remains its main limitation.

Humans

Vaginal Hysterectomy Versus Vaginal Assisted Natural Orifice Transluminal Endoscopic Surgery Hysterectomy; Results of a Randomised Controlled Trial.

OBJECTIVE: To compare Vaginal Hysterectomy (VH) with Vaginal Assisted Natural Orifice Transluminal Endoscopic Surgery (NOTES) hysterectomy (VANH) as a day-care procedure. DESIGN: Single-blind, multicentre randomised controlled trial. SETTING: Two Dutch non-academic teaching hospitals. POPULATION: Women aged &#x2265;&#x2009;18&#x2009;years undergoing hysterectomy for benign indications. METHODS: Women were randomised 1:2 (VH or VANH). Primary outcome was SDD. Secondary outcomes included operative time, rate of elective salpingectomies, intraoperative blood loss, complications (Clavien-Dindo), pain scores (NRS) and analgesic use, post-operative recovery (RI-10), and quality of life (EQ-5D-5L). Analyses were performed on an intention-to-treat basis. RESULTS: A total of 113 patients were included in the analyses (n&#x2009;=&#x2009;42 VH, and n&#x2009;=&#x2009;71 VANH). SDD occurred significantly more frequently in the VANH group (87.3%) than VH group (71.4%; OR 2.76, 95% CI 1.04-7.25; p&#x2009;=&#x2009;0.04). VANH was associated with a significantly shorter operative time (median 55&#x2009;min versus 65&#x2009;min; p&#x2009;=&#x2009;0.005), less blood loss (median 50&#x2009;mL vs. 150&#x2009;mL; p&#x2009;<&#x2009;0.001) and more often elective opportunistic salpingectomy compared to VH (100% vs. 77.4%; p&#x2009;=&#x2009;0.008). NRS were significantly lower in the VANH group the first hour post-operative (3 vs. 1, p&#x2009;<&#x2009;0.001). Post-operative complications (VH 9.5% vs. VANH 15.5%; p&#x2009;=&#x2009;0.34), readmission (VH 4.8% vs. VANH 8.5%; p&#x2009;=&#x2009;0.47), analgesic use, recovery, and quality of life were not statistically significant. CONCLUSIONS: VANH is a safe and effective alternative to VH, offering a higher likelihood of SDD, shorter operative time, reduced blood loss, and more often an elective salpingectomy, without increased complications or differences in pain, recovery, or quality of life.

Humans

Systematic modular engineering of genome-integrated Escherichia coli MG1655 for high-level 2'-fucosyllactose production.

2'-Fucosyllactose (2'-FL), the most abundant human milk oligosaccharide (HMO), has attracted considerable interest for its prebiotic and immunomodulatory functions, with broad applications in infant nutrition. In this study, we report the development of a high-yield, genome-integrated 2'-FL-producing strain based on Escherichia coli MG1655 through systematic modular optimization. Starting from a single-copy BKHT strain (MGC06), we first optimized the copy number of the &#x3b1;-1,2-fucosyltransferase (&#x3b1;-1,2-FT) gene BKHT. Subsequently, the GDP-L-fucose supply was enhanced through coordinated genomic integration of the gene clusters cpsG-cpsB and gmd-fcl, while the multidrug efflux transporter gene mdfA was integrated to improve product export and strain robustness. BKHT copy number was then re-evaluated in the optimized background, with four copies yielding the highest production. The final engineered strain, harboring all genetic modifications stably integrated into the chromosome, produced 17.18 g/L 2'-FL in shake-flask culture. In fed-batch fermentation using a 5-L bioreactor, this strain achieved a titer of 154.12 g/L after 60&#x202f;h, with a productivity of 2.57 g/L/h. Notably, throughout the entire fermentation process, no antibiotics or inducers were supplemented, underscoring the genetic stability and regulatory compliance of this plasmid-free system. To our knowledge, this represents the highest 2'-FL titer reported to date, positioning our engineered strain as a promising candidate for commercial 2'-FL production.

Escherichia coli

Hydrodissection-assisted laparoscopic orchiopexy utilizing needle grasper for palpable undescended testes: Clinical efficacy analysis.

OBJECTIVE: Laparoscopic orchiopexy has emerged as a viable alternative for the treatment of palpable undescended testis (UDT). This study aims to evaluate the feasibility and efficacy of needle-grasper hydrodissection-assisted laparoscopic orchiopexy (NHLO) in comparison to conventional laparoscopic orchiopexy (CLO) for palpable UDT. METHODS: A cohort of 96 patients diagnosed with palpable UDT, admitted between January 2020 and April 2024, was included in this study. Among these, 54 patients underwent NHLO, while 42 patients were treated with CLO. In the NHLO procedure, normal saline was injected into the retroperitoneal space to create a hydrodissection barrier, facilitating the separation and protection of the vas deferens and spermatic cord. The vas deferens and spermatic cord were meticulously dissected following the principles of integrity and minimal tissue trauma. Outcome measures included final testicular position, testicular volume growth, testicular atrophy, success rate, and postoperative complications. RESULTS: No significant differences were observed between the NHLO and CLO groups in terms of age, laterality, operative time (NHLO: 38-46 min; CLO: 39-48 min), or complication rates (NHLO: 1.9 %; CLO: 0.0 %). At follow-up, all patients in both groups exhibited palpable testes in satisfactory scrotal positions. Notably, no visible abdominal scarring was observed in the NHLO group, whereas there were two noticeable scars on the abdomen in CLO. CONCLUSION: Needle-grasper hydrodissection-assisted laparoscopic orchiopexy is a safe, effective, and minimally invasive technique that provides optimal protection of the vas deferens and spermatic cord while achieving excellent cosmetic outcomes.

Humans

An AI-assisted Clinical Decision Support System for Green Classification of Cystocele on Dynamic Transperineal Ultrasound.

Green classification of cystocele on dynamic transperineal ultrasound (TPUS) remains operator-dependent because it requires manual frame selection and landmark-based assessment of the Valsalva maneuver. We developed a workflow-oriented AI-assisted clinical decision support system for automated urethrovesical junction localization and dynamic Green classification and prospectively evaluated its standalone and reader-support performance. This diagnostic accuracy and reader study included 881 patients from a tertiary referral hospital, comprising a retrospective development cohort (n&#x2009;=&#x2009;688) and an independent prospective test cohort (n&#x2009;=&#x2009;193). A nested subset of 67 prospective patients was used for a reader study involving two junior and two intermediate radiologists under unaided and AI-assisted conditions. In the complete prospective test cohort, Green-AttGRU achieved a macro-averaged AUC of 0.939 (95% CI, 0.897-0.971) and an overall accuracy of 0.902 (95% CI, 0.860-0.943). In the reader study, overall accuracy increased from 0.761 to 0.821 without AI to 0.851-0.881 with AI, while macro-F1 increased from 0.660 to 0.777 to 0.820-0.860. Overall inter-reader agreement increased from a Fleiss' &#x3ba; of 0.453 to 0.786, and pooled median interpretation time decreased from 26.7&#xa0;s to 9.9&#xa0;s. These findings support the preliminary feasibility of the system as a workflow-oriented decision-support tool for dynamic TPUS interpretation.

Humans

Immersive virtual reality-assisted anatomy training improves endotracheal intubation performance in simulation: a randomized controlled trial among Chinese non-anesthesiology residents.

INTRODUCTION: This study aimed to compare immersive virtual reality (IVR)-assisted versus conventional anatomy training for teaching endotracheal intubation (ETI) to novice non-anesthesiology residents enrolled in China's Standardized Residency Training program. METHODS: A total of 90 non-anesthesiology residents without prior ETI experience were randomly assigned to either an IVR group receiving IVR-assisted anatomy training (n&#x2009;=&#x2009;45) or a control group receiving conventional anatomy training (n&#x2009;=&#x2009;45). All participants underwent a standardized teaching protocol. The primary endpoint was residents' ETI performance on a simulator, assessed using both the Global Rating Scale (GRS) and a task-specific checklist. The secondary endpoints included changes in written multiple-choice question (MCQ) scores and residents' evaluations of the course. RESULTS: In practical ETI assessments on a manikin, the IVR group achieved significantly higher scores on the task-specific checklist than the control group (90.34&#x2009;&#xb1;&#x2009;2.89 vs. 87.20&#x2009;&#xb1;&#x2009;3.29; p&#x2009;<&#x2009;0.001), whereas GRS scores were comparable between groups. Both groups showed significant post-training improvement in knowledge scores (p&#x2009;<&#x2009;0.001), with the IVR group showing a greater gain in theoretical knowledge (54.0% vs. 36.3%; p&#x2009;<&#x2009;0.001). Participants in the IVR group also expressed a stronger preference for their training method (80.8%) and reported higher levels of motivation, confidence, and enjoyment (all p&#x2009;<&#x2009;0.05). CONCLUSION: IVR-assisted anatomy training enhances the effectiveness of ETI training for novice non-anesthesiology residents, offering an interactive, engaging, and reproducible approach within China's Standardized Residency Training framework.

Humans

Melatonin Levels in 89 Individuals With Smith Magenis Syndrome.

In patients with Smith-Magenis syndrome (SMS), an inverted circadian rhythm of melatonin (MT) contributes to the sleep disturbance. Standard treatment of sleep disturbance with MT often leads to extremely high daytime MT levels, resulting in even more sleep disorders. We therefore retrospectively evaluated the MT data of 89 SMS patients. Mean MT levels in participants on exogenous MT were significantly higher than in participants that did not use MT (p&#x2009;=&#x2009;<&#x2009;0.0001). In 9 participants with very high MT levels, these dropped significantly after discontinuation of exogenous MT (p&#x2009;=&#x2009;0.0037). In 12 participants, MT levels were significantly higher after MT therapy start compared to MT levels before MT start (p&#x2009;=&#x2009;0.028). MT is catabolized principally by the CYP1A2 enzyme, with a half-life of about 40&#x2009;min. CYP1A2 genotyping was performed in five participants with high MT levels during MT use. Although clinically suspected to be a poor CYP1A2 metabolizer, all five turned out to have haplotype CYP1A2*1F, which is associated with increased enzyme activity. This shows that genotyping of CYP1A2 is not suitable to estimate the level of CYP1A2 enzyme activity. When prescribing MT, it is strongly recommended to measure a MT level prior to treatment in order to determine the dose to be given. Checks of the MT level during treatment are necessary due to the frequent occurrence of poor CYP1A2 metabolism. Since CYP1A2 genotyping does not provide adequate information about the level of CYP1A2 enzyme activity, we propose a simple way to determine CYP1A2 phenotype.

Humans

Ketamine assisted psychotherapy to reduce chronic neuropathic pain: A mixed-methods randomized pilot trial.

BACKGROUND: Intravenous ketamine can provide short-term analgesia in chronic neuropathic pain but benefits often wane after treatment. We conducted a randomized pilot trial to assess the feasibility of combining ketamine infusions with psychotherapy to inform future efficacy trials. METHODS: In this single-center, randomized, outcome-assessor-blinded pilot trial at a Canadian tertiary pain clinic, adults with moderate-to-severe chronic neuropathic pain were randomly assigned in 1:1:1 ratio to the ketamine, psychotherapy, or combined ketamine plus psychotherapy arm. Ketamine was delivered as three intravenous infusions over 16 weeks; psychotherapy consisted of 16 weekly cognitive behavioral therapy and mindfulness-based meditation sessions. The primary outcome was feasibility, assessed using prespecified progression criteria. Exploratory outcomes included changes in pain interference (PROMIS 6a T-score), pain intensity, mood, and qualitative interview findings at week 20 (ClinicalTrials.gov: NCT05639322). FINDINGS: Between October 23, 2023, and March 31, 2025, 30 participants were randomized, and 26 (87%) completed 20-week follow-up. Most feasibility criteria, including consent, retention, data completeness, and absence of study-related serious adverse events, were met; adherence targets were partially met. Exploratory pain outcomes showed numerical improvement across groups, with clinically meaningful reductions observed for pain interference and pain intensity. Sixty-four adverse events were recorded, mostly mild and in ketamine-containing groups; no serious study-related adverse events occurred. CONCLUSIONS: Combined ketamine and psychotherapy was feasible and acceptably safe in this pilot trial, supporting evaluation in a larger efficacy-powered study. FUNDING: The study was funded by the St. Michael's Hospital Innovation Fund, The Canadian Pain Society Early Investigator Award and the Physician Services Incorporation Early Career Researcher Award.

Humans

Transabdominal lumbar approach (TALA) versus retroperitoneal approach for robot-assisted renal surgery: a prospective randomised controlled trial.

PURPOSE: Common robotic nephrectomy approaches access the kidney via transperitoneal (TP) or retroperitoneal (RP) routes, each with distinct trade-offs. We developed the transabdominal lumbar approach (TALA), combining advantages of both accesses with improved visualisation and strategic trocar placement, and compared it with conventional RP in a prospective randomised controlled trial using technique-oriented intraoperative endpoints. METHODS: In this single-centre, prospective, open-label RCT, 40 patients were randomised to TALA (n&#x2009;=&#x2009;18) or conventional RP (n&#x2009;=&#x2009;22). Eligible patients were &#x2265;&#x2009;18 years with a renal tumour or non-functional kidney requiring robot-assisted total or partial nephrectomy. Exclusions included prior surgery on the affected kidney, renal vein tumour thrombus, and pregnancy. Both groups were followed for 30 days. The primary endpoint was time from first skin incision to renal artery identification. RESULTS: TALA achieved a median time saving of 16&#xa0;min compared to conventional RP (38 vs. 54&#xa0;min, p&#x2009;=&#x2009;0.001). Perioperative safety was comparable between groups, with three patients (7.5%) experiencing Clavien-Dindo grade III-IV complications. CONCLUSIONS: TALA met its primary endpoint with a significantly shorter time to renal artery identification than conventional RP access, and improving perceived surgical exposure and instrument handling.

Humans

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans

An RPA-assisted homogeneous electrochemical DNA sensor for on-site eDNA detection toward early warning of crown-of-thorns starfish outbreaks.

Crown-of-thorns starfish (COTS) outbreaks seriously threaten coral reef ecosystems, while conventional monitoring approaches are time-consuming and often lack sufficient sensitivity for early warning. Existing electrochemical DNA sensors usually require complex electrode-surface immobilization procedures, which can lead to uneven probe distribution, significant steric hindrance, and poor stability. Meanwhile, the low concentration of environmental DNA (eDNA) in marine environments further complicates detection. To overcome these challenges, this study developed a homogeneous electrochemical DNA sensor assisted by recombinase polymerase amplification (RPA) for COTS eDNA detection. Target DNA was first amplified by RPA, and the amplification products were then hybridized in solution with capture probe (CP)-modified magnetic beads (MB) and biotin-labeled signal probe (SP) to form sandwich-structured MB complexes. These complexes were subsequently magnetically enriched and immobilized on the electrode surface for electrochemical signal readout. Under optimized conditions, the sensor displayed a linear response to COTS genomic DNA from 3.77&#xa0;fg/&#x3bc;L to 1&#xa0;ng/&#x3bc;L, with an LOD of 2.02&#xa0;fg/&#x3bc;L and an LOQ of 3.77&#xa0;fg/&#x3bc;L. The sensor was applied to Xisha Islands samples, and the results agreed with droplet digital PCR (ddPCR) (P&#xa0;>&#xa0;0.05), demonstrating its potential for sensitive and reliable on-site COTS eDNA detection.

Animals

Robotic-assisted transbronchial biopsy versus computed tomography-guided transthoracic needle biopsy for peripheral pulmonary lesions: a systematic review and meta-analysis of direct comparative studies.

Robotic-assisted bronchoscopy (RAB) and computed tomography-guided transthoracic biopsy (CTTB) are competing strategies for sampling peripheral pulmonary lesions (PPLs). Whether they differ in yield or safety is uncertain. To our knowledge, this is the first systematic review restricted to direct comparisons. We searched MEDLINE, Europe PMC, Scopus, Web of Science and ClinicalTrials.gov from inception to 7 July 2026 for studies directly comparing RAB with CTTB in adults with PPLs. The primary outcome was strict 2024 American Thoracic Society/American College of Chest Physicians diagnostic yield. Risk of bias was assessed with ROBINS-I and certainty with GRADE. A cohort-genealogy step identified, per outcome, the largest set of cohorts sharing no patients; only that set was pooled, with Hartung-Knapp and Mantel-Haenszel sensitivity analyses. Five retrospective studies from one US health system were eligible. Four share patients; at most three cohorts are mutually independent. Across those three, diagnostic yield was comparable (risk ratio [RR] 0.99, 95% confidence interval [CI] 0.93-1.06; I&#xb2;=24%; Hartung-Knapp 0.87-1.13), with an identical relative effect under strict and intermediate definitions although absolute yields fell from 88% to 74-84% under strict criteria. Pneumothorax requiring a chest tube and/or admission was about three-quarters less frequent with RAB across all three cohorts (RR 0.25, 95% CI 0.14-0.46; I&#xb2;=0%; Hartung-Knapp 0.07-0.96). Strict yield (RR 0.99) and any pneumothorax (RR 0.06) were reported by two cohorts each and neither survives the few-studies correction. RAB took about 50&#xa0;min longer than CTTB where same-session staging endobronchial ultrasound was counted in the robotic time, but only about 8&#xa0;min longer than CTTB where it was not. Only one cohort reported yield by lesion size category and none reported yield by bronchus sign or lung zone, so lesion-level subgroups could not be pooled. Certainty was low for pleural complications and very low elsewhere. Low-certainty evidence indicates that RAB is associated with fewer pleural complications, with no statistically detectable difference in diagnostic yield; equivalence was not formally established. Because all evidence is retrospective, confined to one health system, and almost never stratified by lesion size or accessibility, these findings are hypothesis-generating and require a multicenter randomized trial.

Humans

Infertility treatment in women with epilepsy: A systematic review.

BACKGROUND: The impact of assisted reproductive technologies (ART) on seizure control in women with epilepsy remains incompletely understood. METHODS: A systematic review was conducted according to PRISMA guidelines. EMBASE, MEDLINE, CINAHL, Scopus, and the Cochrane Library were searched from inception to March 2025. Eligible studies included observational studies and case-based reports involving women undergoing infertility treatment. RESULTS: A total of 1216 publications were identified, of which four studies met the inclusion criteria, including case reports, a case series, and a cohort study. These studies included 16 women aged 25-46&#xa0;years undergoing infertility treatment, all but one of whom had epilepsy. Interventions involved in vitro fertilization (IVF), ovulation induction, and hormonal therapies. Patients were treated with a range of antiseizure medications (ASMs), including carbamazepine, clobazam, lamotrigine, levetiracetam, oxcarbazepine, valproate, and zonisamide, either as monotherapy or in combination. Seizure frequency was generally stable, with most patients maintaining baseline seizure control. Seizure exacerbations were uncommon and primarily associated with hormonal therapy and reduced ASM levels, particularly reduced lamotrigine levels. Reported events included breakthrough seizures in the setting of decreased lamotrigine concentrations, seizure clusters associated with follitropin beta, and a new-onset seizure following dehydroepiandrosterone exposure. Across studies, multiple ART attempts resulted in live births with different ASM regimens, as well as in patients not receiving ASMs. CONCLUSION: Available evidence suggests that ART is feasible in women with epilepsy, with most patients maintaining stable seizure control. Hormonal therapy may affect ASM pharmacokinetics and seizure threshold, thereby warranting close monitoring. Larger prospective studies are needed to better define ASM-specific effects and optimize care.

Humans

Hip Arthroscopy-Assisted Management of Pipkin Types I and II Femoral Head Fracture-Dislocations: Mid-Term Clinical and Radiographic Outcomes.

OBJECTIVES: Hip arthroscopy-assisted surgery has been proposed as a minimally invasive option for femoral head fractures; however, evidence with mid-term follow-up remains limited. This study aimed to evaluate the clinical and radiographic outcomes of arthroscopy-assisted management for Pipkin Types I and II femoral head fracture-dislocations with a minimum follow-up of 5&#x2009;years. METHODS: This retrospective study included 23 consecutive adults (19 Pipkin I and 4 Pipkin II) treated with hip arthroscopy-assisted fragment excision or internal fixation between March 2013 and January 2020. Preoperative computed tomography was used for surgical planning, and fixation was placed with arthroscopic headless screws. Clinical outcomes were assessed using the Harris Hip Score (HHS) and Thompson-Epstein (T-E) criteria. Radiographic evaluation included avascular necrosis (AVN), heterotopic ossification (HO; Brooker), osteoarthritis (OA; T&#xf6;nnis), and fracture reduction quality (Matta's criteria). Group comparisons were evaluated using independent samples t-tests, Mann-Whitney U tests, and Fisher's exact test. The mean follow-up was 86.2&#x2009;&#xb1;&#x2009;21.2&#x2009;months. RESULTS: The cohort consisted of 19 males and 4 females with a mean age of 28.7&#x2009;&#xb1;&#x2009;9.9&#x2009;years. Fifteen patients underwent fixation and eight underwent excision. The final mean HHS was 98.3&#x2009;&#xb1;&#x2009;1.9, with 21 patients (91%) achieving excellent and 2 (9%) good T-E criteria. There were no significant differences between the fixation and excision groups in demographic characteristics, operative time, or functional outcomes (all p&#x2009;>&#x2009;0.05); however, hospital stay was significantly shorter in the excision group (2.9&#x2009;&#xb1;&#x2009;0.6 vs. 5.5&#x2009;&#xb1;&#x2009;4.6&#x2009;days, p&#x2009;=&#x2009;0.028). In the fixation group, mean maximal displacement improved from 7.6&#x2009;mm preoperatively to 2.6&#x2009;mm postoperatively, with anatomic reduction achieved in 6 cases (40%), imperfect in 6 (40%), and poor in 3 (20%). Patients with Pipkin Type I fractures had significantly higher HHS than those with Type II fractures (98.7&#x2009;&#xb1;&#x2009;1.7 vs. 96.0&#x2009;&#xb1;&#x2009;0.8, p&#x2009;=&#x2009;0.018). Complications were rare, with one case of Brooker Grade I HO and one case of mild OA. No AVN or total hip arthroplasty occurred during the follow-up. CONCLUSIONS: Hip arthroscopy-assisted management of selected Pipkin Type I and II femoral head fractures yields excellent mid-term clinical outcomes with acceptable radiographic reduction and a low complication rate. This minimally invasive technique represents a viable alternative in appropriately selected patients when fragment characteristics and surgical expertise permit.

Humans