Search PubMedSearch

SEARCH · Search PubMed

Results for “Body image”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

387 records · Page 4Linked to original sources

Diffusion MRI radiomics in meningiomas: imaging correlates of tumor grade and intraoperative consistency.

OBJECTIVE: Despite advancements in imaging studies, the preoperative prediction of the biological behavior and intraoperative consistency of intracranial meningiomas remains limited. This study evaluated the association of volumetric diffusion-based and texture-derived radiomic features extracted from routine MRI with histopathological aggressiveness and intraoperative tumor consistency. METHODS: Ninety-seven intracranial meningiomas resected at two tertiary centers were retrospectively analyzed. Volumetric segmentation was performed on contrast-enhanced T1-weighted MRI and coregistered to apparent diffusion coefficient (ADC) maps. Data on first-order diffusion metrics and selected texture features were collected. The associations between World Health Organization (WHO) grade and Ki-67 index were assessed using nonparametric tests and Spearman correlation analysis. Independent factors associated with intraoperative tumor consistency (Zada grades 1-5) were evaluated via multivariate ordinal logistic regression analysis that adjusted for tumor volume, skull base location, calcification status, and WHO grade. Secondary receiver operating characteristic (ROC) curve analyses were performed to differentiate solid (Zada grades 4-5) from soft (Zada grades 1-2) tumors. ROC analyses were performed within the study cohort and were intended as exploratory assessments of discriminative performance. RESULTS: The mean ADC (ADCmean) and the 10th percentile of the ADC decreased significantly with increasing WHO grade (p < 0.001). ADCmean had a moderate inverse correlation with the Ki-67 index (r = -0.42, p < 0.001) and intraoperative tumor consistency (r = -0.45, p < 0.001). In the multivariate analysis, the ADCmean remained independently associated with increasing tumor firmness. Each 0.1 &#xd7; 10-3 mm2/sec increase corresponded to a 38% reduction in the odds of belonging to a higher consistency category (OR 0.62, 95% CI 0.51-0.74, p < 0.001). The ROC analysis showed good discrimination for solid tumors (area under the curve 0.847, 95% CI 0.742-0.953) and soft tumors (area under the curve 0.824, 95% CI 0.714-0.935). Texture features had weaker associations with intraoperative tumor consistency. CONCLUSIONS: Volumetric diffusion-derived metrics, particularly ADCmean, are associated with both histopathological aggressiveness and intraoperative tumor firmness in meningiomas. Diffusion imaging may reflect a graded microstructural continuum rather than a purely dichotomous property, providing complementary preoperative insights into surgical complexity.

Humans

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Opposite metabolic and gut responses to oral glutamine in male and female mice with diet-induced obesity.

Obesity is often associated with sex-dependent metabolic complications, to which altered intestinal barrier function and gut microbiota contribute. Glutamine supplementation has previously shown beneficial effects on gut barrier function and glycemic control. We thus aimed to characterize, in male and female mice, the effects of oral glutamine supplementation during high-fat-diet-induced obesity. Male and female C57BL/6 mice received a standard (SD) or high-fat diet (HFD; 60 % kcal from fat) for 14&#xa0;weeks (W14). From W12 onward, mice received glutamine in drinking water (2&#xa0;g/kg/day) or no supplementation. Body composition, glucose tolerance, insulin sensitivity, intestinal permeability, colonic inflammatory response, cecal microbiota and inflammatory/endocrine adipose response were assessed. In both male and female mice, glutamine supplementation failed to improve body weight and body composition. However, glutamine reduced glucose intolerance in HFD-fed males (AUC reduced by 14.57 %) that was associated with a partial restoration of plasma resistin and insulin and a trend toward limiting adipose inflammatory response. In males, glutamine did not affect gut microbiota composition and colonic response. Conversely, in HFD-fed females, glutamine supplementation led to gut microbiota changes (increase in Bacteroidota and Pseudomonadota phyla; increase in Muribaculaceae and Tannerellaceae families), increased colonic inflammatory markers (Il1b, Tlr4, Myd88, Irf3), increased inflammatory response in subcutaneous adipose tissue and increased HOMA-IR. Finally, HFD-fed mice exhibited sex-specific responses to glutamine supplementation with protective effects in males and harmful effects in females that need to be further deeply explored.

Animals

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Enhanced risk stratification in hypertrophic cardiomyopathy through the integration of extracellular volume fraction on cardiovascular magnetic resonance.

AIMS: This study investigated the incremental prognostic value of cardiovascular magnetic resonance (CMR)-derived extracellular volume fraction (ECV), a marker of diffuse interstitial fibrosis, beyond late gadolinium enhancement (LGE) in hypertrophic cardiomyopathy (HCM). METHODS AND RESULTS: We analysed 990 consecutive HCM patients (median age 58 years, male 68.3%) who underwent CMR between 2012 and 2024. LGE and global ECV were quantified, and their associations with the primary endpoint of HCM-related events-a composite of sudden cardiac death (SCD) events, heart failure (HF) events, and HCM-related death-were assessed. During a median follow-up of 3.2 years, 64 (6.5%) patients experienced the primary endpoint. While LGE (median 7.1%, IQR 2.3-16.9%) and ECV (median 29.0%, IQR 26.6-32.0%) were moderately correlated (R = 0.604, P < 0.001), both were significantly associated with increased risk of the primary endpoint and individual outcomes of SCD and HF events, and optimal cutoffs were determined as LGE &#x2265; 27% and ECV &#x2265; 35%. Patients with ECV &#x2265; 35% had more symptoms, a more severe phenotype with greater systolic and diastolic dysfunction, and more pathogenic gene variants. Notably, ECV remained a significant predictor of the primary endpoint (adjusted HR 1.08, 95% CI 1.02-1.15, per 1%) after adjustment for key disease variables, including left ventricular ejection fraction and LGE. Elevated ECV effectively identified high-risk individuals even among lower-risk subgroups, including those with low LGE burden. CONCLUSION: Increased ECV is an independent predictor of HCM-related outcomes. ECV may serve as a novel imaging biomarker to refine risk stratification in HCM patients who do not meet traditional LGE-based high-risk criteria.

Humans

Long-Term Weight Trajectories in Infants Receiving Prolonged Breastfeeding: Impact of Formula Supplementation.

OBJECTIVE: This study compared weight trajectories in infants breastfed for at least 1 year, with or without formula supplementation. STUDY DESIGN: A retrospective cohort of 252 infants followed in well-baby clinics. All infants were breastfed &#x2265;12 months and received complementary foods at 4-6 months. Of these, 174 received no formula, and 78 received daily formula supplementation. Anthropometric data were collected from birth to 5 years of age. RESULTS: Among males, those breastfed without formula had significantly lower body weight between 13 and 18 months compared with those receiving formula (10.20 kg vs. 10.97 kg, p < 0.001). From 19 months onward, no significant weight differences were observed and trajectories converged through 5 years. CONCLUSION: Prolonged breastfeeding in male infants is associated with lower weight in early toddlerhood; however, differences resolve by age two. These findings suggest early variations may represent physiological patterns. Further controlled studies are needed.

Humans

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

Non-destructive prediction of lead content in oilseed rape leaves by fluorescence hyperspectral technology based on neural network.

Based on fluorescence hyperspectral imaging (FHSI), this study targeted rapid, non-destructive quantification of lead (Pb) content in oilseed rape leaves treated with varying silicon (Si) concentrations, acquiring fluorescence spectra over the 484.43-1001.61&#xa0;nm wavelength range. To optimize spectral data quality, preprocessing methods (Savitzky-Golay smoothing, first derivative, detrending) were comprehensively compared. Characteristic wavelengths were then selected via interval variable iterative shrinkage, which effectively compressed data dimensionality and reduced computational load. A hybrid SE-CL1DA model, fusing a 1D convolutional neural network, a long short-term memory network and SE attention mechanism was constructed, with Bayesian optimization tuning hyperparameters to boost stability. The BO-SE-CL1DA outperformed both traditional machine learning and insufficiently optimized deep learning model (Rp2=0.9609, RMSE&#xa0;=&#xa0;0.0377&#xa0;mg/kg, RPD&#xa0;=&#xa0;5.1736), thus enabling accurate Pb estimation, supporting Si-regulated heavy metal stress management and facilitating agricultural contamination monitoring.

Plant Leaves

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Self-Report Health Screening Tools in Female Athletes: A Systematic Review of Domain Coverage, Validation, and Use Across Participation Levels.

BACKGROUND: Female athlete health encompasses multiple interconnected domains; however, the self-report screening tools used to assess these domains have not been comprehensively synthesised. OBJECTIVE: To systematically identify self-report health screening tools used to assess female athlete health, map domain coverage, determine validation reporting, and describe application across participation levels. METHODS: This systematic review was pre-registered with PROSPERO ( CRD420251056910 ) and conducted in accordance with PRISMA guidelines. Four databases (PubMed, MEDLINE, SPORTDiscus and Web of Science) were searched from inception to January 2026 using female health and screening-related terms. Methodological quality was appraised using Joanna Briggs Institute and National Institutes of Health tools, and findings were synthesised descriptively. Eligible, peer-reviewed studies reported the use, development or validation of self-report health screening tools assessing one or more domains relevant to female health applied in female athlete populations, spanning recreational through elite participation levels. All sports and activities were included. The search was restricted to English language with no date limits. RESULTS: In total, 360 studies (1990-2026) representing 134,506 female participants spanning recreational to elite sport and 273 screening tools were included. Mental health (n&#x2009;=&#x2009;77, 34.1%), disordered eating (n&#x2009;=&#x2009;33, 14.6%) and body image (n&#x2009;=&#x2009;30, 13.3%) predominated. Domains related to female health, including menstrual health, pelvic floor health, pregnancy/postpartum and breast health were comparatively underrepresented. Most&#xa0;studies reported tools were used for risk identification (n&#x2009;=&#x2009;323,&#xa0;80.3%). Validation reporting was inconsistent, with half (n&#x2009;=&#x2009;180,&#xa0;50%) reporting use of at least one validated tool. Tool use was concentrated in professional and elite sport, with limited inclusion of recreational, masters and disability athlete cohorts. Health literacy constructs were explicitly&#xa0;assessed in 12.5% of studies&#xa0;(n&#x2009;=&#x2009;45). CONCLUSIONS: Health screening in female athlete populations remains fragmented and uneven in domain coverage, with inconsistent validation reporting. Development of integrated, multi-domain and contextually inclusive screening frameworks is warranted.

Journal Article

Prenatal exome sequencing of fetuses with central nervous system anomalies based on prenatal ultrasound and magnetic resonance imaging diagnosis: A retrospective cohort study with a systematic review and meta-analysis.

INTRODUCTION: Fetal central nervous system (CNS) abnormalities have diverse etiologies, with genetic factors as a major contributor. Prenatal exome sequencing (ES) is a powerful tool for precise molecular diagnosis of CNS anomalies, but its diagnostic yield varies among studies. This study aimed to evaluate the additional diagnostic yield of prenatal ES compared with chromosomal microarray analysis (CMA) in fetuses with CNS anomalies detected by prenatal imaging. MATERIAL AND METHODS: We collected ES results from fetuses diagnosed with CNS anomalies by prenatal imaging (2019-2024) who had negative results. Subgroup analyses assessed phenotype-specific ES diagnostic yield for associated genes and variants. A systematic review and meta-analysis incorporating our data and published studies further explored the association between phenotype and diagnostic yield. RESULTS: In the cohort study of 219 cases, ES identified pathogenic/likely pathogenic single nucleotide variations in 36 cases (16%). The highest diagnostic yield of ES was in cases with multisystem malformations (25%, 14/55), followed by multiple CNS anomalies (15%, 2/13) and isolated CNS anomalies (13%, 20/151). The most commonly identified isolated CNS anomaly was agenesis of the corpus callosum (31%, 5/16). Neural tube defects with urogenital anomalies were associated with a positive ES finding in 57% (4/7) of cases. The meta-analysis of 989 cases from 22 studies showed a pooled diagnostic yield of ES of 27% (95% CI, 21%-34%). The highest diagnostic yield of ES was in cases of corpus callosum anomalies with facial abnormalities (75%, 8/11) and neural tube defects with urogenital malformations (80%, 12/15). The diagnostic yield of ES for three or more CNS abnormalities was 43% (95% CI, 31%-58%), significantly higher than that for only two abnormalities (10%, 95% CI, 4%-18%). No significant difference in diagnostic yield was found between cases identified by prenatal MRI combined with ultrasound (27%, 95% CI, 20%-36%) and those identified by ultrasound alone (25%, 95% CI, 17%-35%). CONCLUSIONS: ES provided a significantly higher diagnostic yield than CMA for fetal CNS abnormalities, with diagnostic yields varying by phenotype. The systematic review and meta-analysis confirmed that the complexity and combination of malformations are key factors associated with differences in ES diagnostic yield.

Humans

Recovering membrane interaction kinetics of single molecules from 3D tracking data.

Interactions between cytosolic biomolecules and the bacterial inner membrane are fundamental to many cellular processes, yet directly measuring their binding kinetics in living cells remains challenging. Conventional 2D single-molecule tracking analyses can be insufficient, particularly when membrane association does not markedly alter the diffusion rate. Here, we present a method to recover membrane interaction kinetics from 3D single-molecule trajectories in rod-shaped bacteria. Using simulated 3D tracking data, we identify membrane-associated motion by quantifying how well short trajectory segments follow the circular curvature of the cell membrane. The resulting measure is further analyzed using a hidden Markov modeling framework, enabling robust discrimination between cytosolic and membrane-bound states and capturing the dynamics of state transitions without requiring diffusion-rate changes or direct colocalization with membrane markers. This work establishes a general framework for extracting membrane interaction kinetics from 3D single-molecule tracking data in live bacteria and highlights the value of realistic microscopy simulations for quantitative interpretation and systematic bias assessment.

Kinetics

[Complex therapy of chronic bacterial prostatitis using the immunomodulatory drug sodium aminodihydrophthalazinedione].

INTRODUCTION: Chronic bacterial prostatitis (CBP) is characterized by a recurrent course caused by pathogen persistence and impaired local immunity of the prostate. AIM: To assess the effectiveness of the use of sodium aminodihydrophthalazinedione in the complex therapy of chronic bacterial prostatitis. MATERIALS AND METHODS: The prospective comparative study included 60 men aged 21-50 years with CBP (NIH category II). Patients were randomized into two groups of 30: the comparison group received levofloxacin 500 mg/day for 28 days; the main group additionally received rectal sodium aminodihydrophthalazinedione. NIH-CPSI, IPSS, QoL, uroflowmetry, leukocyte and lecithin body counts in prostatic secretion, and bacteriological examination were assessed at baseline and on day 28, and the recurrence rate over 3 months. RESULTS: By day 28, the main group showed a more pronounced decrease in the total NIH-CPSI score (8.1+/-2.1 vs 13.4+/-2.6; p<0.001), restoration of lecithin bodies (+65.1% vs +24.5%; p<0.05), normalization of uroflowmetry, and pathogen eradication in 86.7% vs 66.7% of patients (p<0.05). The 3-month recurrence rate decreased from 26.7 to 10.0% (p<0.05). No adverse events were registered. DISCUSSION: The advantage of combinationtherapy is due to the combination of anti-inflammatory,immunomodulatory,antioxidantandregenerativeeffects of the drug,which is confirmed by the restoration of the secretoryfunction of the prostateepitheliumaccording to the dynamics of lecithingrains. CONCLUSION: The inclusion of sodium aminodihydrophthalazinedione in the combination therapy of CBP increases the clinical and microbiological efficacy of treatment and reduces the recurrence rate.

Humans

Intravenous thrombolysis for ischemic stroke in extended time window selected with CT perfusion: a systematic review and meta-analysis.

PURPOSE: Recent randomized controlled trials (RCTs) have provided new evidence regarding the efficacy and safety of intravenous thrombolysis (IVT) in patients with acute ischemic stroke (AIS) presenting within the extended time window (ETW). We performed a systematic review and meta-analysis to evaluate the efficacy and safety of IVT, in patients treated within the ETW and selected with perfusion imaging criteria, predominantly computed tomography perfusion (CTP). METHODS: A systematic review and meta-analysis, registered in PROSPERO, was conducted including all available RCTs comparing IVT with best medical treatment (BMT) in patients with AIS within the ETW, selected using advanced perfusion imaging criteria. The predefined efficacy outcomes were excellent functional outcome and good functional outcome at 3 months. The safety endpoints included symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days. RESULTS: Six RCTs, including 1182 patients treated with IVT and 1176 patients receiving BMT, were included. IVT was associated with a higher likelihood of achieving excellent and good functional outcomes at 3 months. Exploratory subgroup analyses by treatment timing suggested consistent findings up to 24 hours. No significant difference in 90-day mortality was observed between groups, whereas IVT was associated with an increased risk of sICH. CONCLUSION: Treatment with IVT in the ETW (4.5-24 h) in patients selected using advanced perfusion imaging, predominantly CTP, may be associated with improved functional outcomes in patients with AIS. Although IVT was associated with an increased risk of sICH, no significant increase in 90-day mortality was observed. PROSPERO REGISTRATION: CRD420261304314.

Aged

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Spatial proximity or vector orientation? Re-evaluating ECG interpretation in anterior myocardial infarction using cardiac magnetic resonance.

BACKGROUND: The electrocardiogram (ECG) is widely used to infer infarct location and extent in anterior myocardial infarction (MI), based on either anatomical lead proximity or vectorial orientation of ST-segment deviation. However, the validity of these approaches against direct imaging of myocardial injury remains uncertain. METHODS: In this prospective study, 105 patients with anterior MI underwent cardiac magnetic resonance (CMR) imaging 3-7&#xa0;days after presentation. Admission ECGs were analyzed using (1) conventional ECG localization categories, and (2) simplified frontal and horizontal ST-axis orientation. CMR-defined injury distribution was assessed using late gadolinium enhancement and myocardial edema imaging. RESULTS: Conventional ECG localization categories demonstrated no significant association with CMR-defined infarct distribution (P&#xa0;=&#xa0;0.24), with poor agreement (&#x3ba;&#xa0;=&#xa0;0.122) and substantial overlap across categories. Simplified ST-axis orientation showed modest and inconsistent associations with infarct location and did not meaningfully explain infarct size. In contrast, global ST-segment burden was associated with CMR-defined infarct size (&#x3a3;STE: standardized &#x3b2;&#xa0;=&#xa0;0.307, P&#xa0;=&#xa0;0.002; lead count: standardized &#x3b2;&#xa0;=&#xa0;0.267, P&#xa0;=&#xa0;0.007). CONCLUSIONS: In this selected cohort of reperfused LAD-related anterior STEMI patients undergoing early CMR, conventional ECG localization categories and simplified ST-axis orientation showed poor or inconsistent correspondence with CMR-defined infarct distribution, whereas global ST-segment burden showed a modest association with infarct size. These findings suggest that, in this cohort, the ECG may be better suited to reflect the extent of myocardial injury rather than its precise anatomical location.

Humans

A two-center randomized clinical superiority trial of single-anastomosis sleeve ileal bypass versus sleeve gastrectomy for severe obesity: SASSY study protocol.

BACKGROUND: Single-anastomosis sleeve ileal bypass is a novel metabolic bariatric surgery intended to enhance metabolic outcomes and reduce the risk of postoperative complications. Although preliminary outcome data for single-anastomosis sleeve ileal bypass are promising, evidence from adequately powered, randomized head-to-head comparisons is scarce. This trial compares the efficacy and safety of single-anastomosis sleeve ileal bypass versus sleeve gastrectomy in patients with class II obesity (body mass index = 35.0-39.9&#x2009;kg/m&#xb2;) with at least one obesity&#x2011;related comorbidity or class III obesity (body mass index &#x2a7e;40.0&#x2009;kg/m&#xb2;). METHODS: This two-center randomized clinical superiority trial enrolls patients eligible for metabolic bariatric surgery at two specialized Norwegian centers. Included patients are randomly assigned (1:1) to either single-anastomosis sleeve ileal bypass or sleeve gastrectomy with standardized perioperative treatment and care. The primary endpoint is the between-group difference in change in body mass index from baseline to 2&#x2009;years after single-anastomosis sleeve ileal bypass versus sleeve gastrectomy. Secondary endpoints include additional weight loss outcomes, the prevalence of gastroesophageal reflux disease, surgical and postoperative complications, obesity-related comorbidities, nutritional status, bone mineral density, gastrointestinal symptoms, quality of life, and rates of revisional and conversion surgery. All endpoints will be evaluated at 2 and 5&#x2009;years after surgery. Statistical analyses utilize linear mixed models and analysis of covariance within an intention-to-treat framework. DISCUSSION: This trial will provide high-level evidence with robust and comparative outcome data on single-anastomosis sleeve ileal bypass and sleeve gastrectomy, aiming to clarify the clinical utility of single-anastomosis sleeve ileal bypass and inform surgical practice. Findings will address gaps in medium- and long-term evidence regarding weight loss, safety, comorbidity resolution, and quality of life following single-anastomosis sleeve ileal bypass.

Humans

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans