Development and validation of a novel LC-MS/MS method for simultaneous quantification of fidaxomicin and metabolite (OP-1118) from feces for gut pharmacobiome studies.
Fidaxomicin is a first-line antibiotic for treating Clostridioides difficile infection. While it has low systemic absorption and reaches high colonic concentrations, it is hydrolyzed to a less active metabolite, OP-1118. Few studies have completely described critical experimental details of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantifying fecal fidaxomicin and OP-1118. This study developed and validated a simple, fast, and sensitive LC-MS/MS method to quantify fidaxomicin and OP-1118 in human and mouse feces. This method simplified fecal sample preparation without the use of solid phase extraction and optimized LC-MS/MS parameters. A broad working range (0.3-1000 ng/ml) in both diluted human and murine fecal matrices was achieved with good intra- and inter-day accuracy (93-107%), precision (1-7%), and recovery (70-105%) as well as little IS-normalized matrix effects. This method was utilized to quantify fidaxomicin and OP-1118 in human and murine fecal samples. This novel method was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.