Search PubMedSearch

SEARCH · Search PubMed

Results for “Fluorescence hyperspectral imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

240 records · Page 3Linked to original sources

The role of media in reducing and reinforcing stigma: A randomized controlled trial investigating the impact of positive and negative representations of visible difference.

OBJECTIVES: Individuals with visible differences often experience appearance-related stigma and discrimination, reinforced by negative media portrayals. In contrast, positive portrayals may challenge stereotypes and promote acceptance. This study examined whether exposure to positive, negative or neutral images of visible difference influences appearance-related stigma, body appreciation and broad conceptualizations of beauty. It was hypothesized that positive images would decrease stigma and increase body appreciation and broad conceptualizations of beauty, whereas negative images would increase stigma and reduce broad conceptualizations of beauty. DESIGN: An online randomized controlled experiment using a mixed repeated-measures design compared three conditions (positive, negative, neutral) across pre- and post-exposure. METHODS: A sample of 103 adults viewed 10 images of individuals with visible differences presented in one of three conditions: positive (positive captions), negative (villains with visible differences and negative captions) or neutral (without captions). Participants completed pre- and post-measures of appearance-related stigma, body appreciation and broad conceptualizations of beauty. Repeated-measures ANOVAs examined within- and between-group changes. RESULTS: Appearance-related stigma significantly increased in the negative condition, while remaining unchanged in the positive and neutral groups. Body appreciation significantly increased from pre- to post- across all conditions. No significant effects emerged for broad conceptualizations of beauty. CONCLUSIONS: Negative portrayals of visible difference may reinforce stigma, highlighting the need to discourage such depictions in media. While positive exposure did not significantly reduce stigma, viewing images of visible difference increased observers' body appreciation, indicating potential downward social comparison. Future research should explore strategies to strengthen stigma reduction and broaden conceptualizations of beauty.

Humans

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Enhanced risk stratification in hypertrophic cardiomyopathy through the integration of extracellular volume fraction on cardiovascular magnetic resonance.

AIMS: This study investigated the incremental prognostic value of cardiovascular magnetic resonance (CMR)-derived extracellular volume fraction (ECV), a marker of diffuse interstitial fibrosis, beyond late gadolinium enhancement (LGE) in hypertrophic cardiomyopathy (HCM). METHODS AND RESULTS: We analysed 990 consecutive HCM patients (median age 58 years, male 68.3%) who underwent CMR between 2012 and 2024. LGE and global ECV were quantified, and their associations with the primary endpoint of HCM-related events-a composite of sudden cardiac death (SCD) events, heart failure (HF) events, and HCM-related death-were assessed. During a median follow-up of 3.2 years, 64 (6.5%) patients experienced the primary endpoint. While LGE (median 7.1%, IQR 2.3-16.9%) and ECV (median 29.0%, IQR 26.6-32.0%) were moderately correlated (R = 0.604, P < 0.001), both were significantly associated with increased risk of the primary endpoint and individual outcomes of SCD and HF events, and optimal cutoffs were determined as LGE &#x2265; 27% and ECV &#x2265; 35%. Patients with ECV &#x2265; 35% had more symptoms, a more severe phenotype with greater systolic and diastolic dysfunction, and more pathogenic gene variants. Notably, ECV remained a significant predictor of the primary endpoint (adjusted HR 1.08, 95% CI 1.02-1.15, per 1%) after adjustment for key disease variables, including left ventricular ejection fraction and LGE. Elevated ECV effectively identified high-risk individuals even among lower-risk subgroups, including those with low LGE burden. CONCLUSION: Increased ECV is an independent predictor of HCM-related outcomes. ECV may serve as a novel imaging biomarker to refine risk stratification in HCM patients who do not meet traditional LGE-based high-risk criteria.

Humans

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Prenatal exome sequencing of fetuses with central nervous system anomalies based on prenatal ultrasound and magnetic resonance imaging diagnosis: A retrospective cohort study with a systematic review and meta-analysis.

INTRODUCTION: Fetal central nervous system (CNS) abnormalities have diverse etiologies, with genetic factors as a major contributor. Prenatal exome sequencing (ES) is a powerful tool for precise molecular diagnosis of CNS anomalies, but its diagnostic yield varies among studies. This study aimed to evaluate the additional diagnostic yield of prenatal ES compared with chromosomal microarray analysis (CMA) in fetuses with CNS anomalies detected by prenatal imaging. MATERIAL AND METHODS: We collected ES results from fetuses diagnosed with CNS anomalies by prenatal imaging (2019-2024) who had negative results. Subgroup analyses assessed phenotype-specific ES diagnostic yield for associated genes and variants. A systematic review and meta-analysis incorporating our data and published studies further explored the association between phenotype and diagnostic yield. RESULTS: In the cohort study of 219 cases, ES identified pathogenic/likely pathogenic single nucleotide variations in 36 cases (16%). The highest diagnostic yield of ES was in cases with multisystem malformations (25%, 14/55), followed by multiple CNS anomalies (15%, 2/13) and isolated CNS anomalies (13%, 20/151). The most commonly identified isolated CNS anomaly was agenesis of the corpus callosum (31%, 5/16). Neural tube defects with urogenital anomalies were associated with a positive ES finding in 57% (4/7) of cases. The meta-analysis of 989 cases from 22 studies showed a pooled diagnostic yield of ES of 27% (95% CI, 21%-34%). The highest diagnostic yield of ES was in cases of corpus callosum anomalies with facial abnormalities (75%, 8/11) and neural tube defects with urogenital malformations (80%, 12/15). The diagnostic yield of ES for three or more CNS abnormalities was 43% (95% CI, 31%-58%), significantly higher than that for only two abnormalities (10%, 95% CI, 4%-18%). No significant difference in diagnostic yield was found between cases identified by prenatal MRI combined with ultrasound (27%, 95% CI, 20%-36%) and those identified by ultrasound alone (25%, 95% CI, 17%-35%). CONCLUSIONS: ES provided a significantly higher diagnostic yield than CMA for fetal CNS abnormalities, with diagnostic yields varying by phenotype. The systematic review and meta-analysis confirmed that the complexity and combination of malformations are key factors associated with differences in ES diagnostic yield.

Humans

Recovering membrane interaction kinetics of single molecules from 3D tracking data.

Interactions between cytosolic biomolecules and the bacterial inner membrane are fundamental to many cellular processes, yet directly measuring their binding kinetics in living cells remains challenging. Conventional 2D single-molecule tracking analyses can be insufficient, particularly when membrane association does not markedly alter the diffusion rate. Here, we present a method to recover membrane interaction kinetics from 3D single-molecule trajectories in rod-shaped bacteria. Using simulated 3D tracking data, we identify membrane-associated motion by quantifying how well short trajectory segments follow the circular curvature of the cell membrane. The resulting measure is further analyzed using a hidden Markov modeling framework, enabling robust discrimination between cytosolic and membrane-bound states and capturing the dynamics of state transitions without requiring diffusion-rate changes or direct colocalization with membrane markers. This work establishes a general framework for extracting membrane interaction kinetics from 3D single-molecule tracking data in live bacteria and highlights the value of realistic microscopy simulations for quantitative interpretation and systematic bias assessment.

Kinetics

Synaptic vesicle glycoprotein 2A PET imaging in parkinsonian &#x3b1;-synucleinopathies: a systematic review.

Synaptic dysfunction is increasingly recognized as an early and biologically relevant component of &#x3b1;-synucleinopathies. However, conventional imaging biomarkers mainly assess dopaminergic dysfunction, glucose metabolism, or structural damage rather than presynaptic density itself. Synaptic vesicle glycoprotein 2A (SV2A) PET enables in vivo assessment of presynaptic terminal integrity and may provide complementary information in Parkinson's disease (PD), Parkinson's disease dementia/dementia with Lewy bodies (PDD/DLB), and multiple system atrophy (MSA). This systematic review synthesized the available evidence on SV2A-targeted PET in parkinsonian &#x3b1;-synucleinopathies, focusing on regional imaging patterns, clinical associations, longitudinal findings, and methodological determinants of interpretation. Seventeen reports were included. In PD, the most recurrent finding was reduced SV2A binding in the substantia nigra, although additional involvement of brainstem, caudate, striatal, thalamic, raphe, or cortical regions was reported in selected cohorts. In PDD/DLB, abnormalities appeared broader and more cortical, with evidence of association between cortical SV2A binding and cognitive performance. In MSA, one study suggested a distinct infratentorial and cerebellar pattern with potential relevance for phenotypic stratification. SV2A PET is a promising research biomarker for biological characterization of synucleinopathies. However, the field remains limited by small cohorts, methodological heterogeneity, variable quantification strategies, limited longitudinal evidence, and potential cohort overlap. Multicentre validation and harmonized protocols are required before clinical translation.

Humans

Elucidating the evolution of meat quality, water distribution, microstructure, and protein structure during sous-vide and micro-pressure cooking.

This study investigated the evolution of eating quality (colour, texture and volatile flavour compounds), water status, microstructure and protein structure of pork meat under different cooking methods. The methods analysed included traditional cooking (TC: 10, 20, 30 and 40&#xa0;min, 100&#xa0;&#xb0;C), sous-vide cooking (SV: 1, 2, 3 and 4&#xa0;h, 60&#xa0;&#xb0;C) and micro-pressure cooking (MC: 10, 20, 30 and 40&#xa0;min, 120&#xa0;&#xb0;C). Across the three cooking processes, as cooking time increased, cooking loss, lightness, yellowness, P23, &#x3b2;-sheet, random coil and surface hydrophobicity of the meat samples increased. By contrast, redness, P22, hydrogen proton density, esters content, &#x3b1;-helix, &#x3b2;-turn and sulfhydryl group content decreased. Moreover, the Warner-Bratzler shear force (WBSF), adhesiveness, hardness, springiness, gumminess, chewiness, alcohols, aldehydes, ketones and fluorescence intensity of the meat samples, initially increased and then decreased as cooking progressed. SV resulted in higher water-holding capacity (WHC), improved redness and increased alcohol and ester levels, whereas MC produced softer meat and greater water mobility. Furthermore, MC enhanced the degree of microstructural damage and protein structural unfolding in the meat. MC requires less time to achieve textures and flavours similar to those obtained using the TC and SV methods. Thus, MC is an efficient cooking method for the catering industry to obtain desired meat quality rapidly.

Cooking

Physical Appearance Anxiety and Eating Disorders Symptomatology: A Systematic Review and Meta-Analysis.

The present study aimed to assess the link between physical appearance anxiety (PAA) and eating disorder (ED) symptomatology by a meta-analysis of existing literature. Eligible studies were searched across six electronic databases up until November 20, 2025. Pooled effect sizes (r) were calculated using random-effects models. Potential variables that influence effect heterogeneity were analyzed by univariable and multivariable meta-regressions. Influence analyses and a three-parameter selection model (3PSM) were used to assess robustness of the results and publication bias. Twenty-seven effect sizes from 21 studies (N&#x2009;=&#x2009;5261) were obtained. The results indicated a strong association (i.e., r&#x2009;=&#x2009;0.559) between the two variables under consideration, which was notably stronger (i) among females compared to males; and (ii) for overall eating disorder symptoms rather than bulimic symptoms. The results of this study advocate for further investigation into the effectiveness of addressing anxiety responses related to personal body traits, particularly among females, within the context of preventing and treating eating disorders.

Humans

Intravenous thrombolysis for ischemic stroke in extended time window selected with CT perfusion: a systematic review and meta-analysis.

PURPOSE: Recent randomized controlled trials (RCTs) have provided new evidence regarding the efficacy and safety of intravenous thrombolysis (IVT) in patients with acute ischemic stroke (AIS) presenting within the extended time window (ETW). We performed a systematic review and meta-analysis to evaluate the efficacy and safety of IVT, in patients treated within the ETW and selected with perfusion imaging criteria, predominantly computed tomography perfusion (CTP). METHODS: A systematic review and meta-analysis, registered in PROSPERO, was conducted including all available RCTs comparing IVT with best medical treatment (BMT) in patients with AIS within the ETW, selected using advanced perfusion imaging criteria. The predefined efficacy outcomes were excellent functional outcome and good functional outcome at 3 months. The safety endpoints included symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days. RESULTS: Six RCTs, including 1182 patients treated with IVT and 1176 patients receiving BMT, were included. IVT was associated with a higher likelihood of achieving excellent and good functional outcomes at 3 months. Exploratory subgroup analyses by treatment timing suggested consistent findings up to 24 hours. No significant difference in 90-day mortality was observed between groups, whereas IVT was associated with an increased risk of sICH. CONCLUSION: Treatment with IVT in the ETW (4.5-24 h) in patients selected using advanced perfusion imaging, predominantly CTP, may be associated with improved functional outcomes in patients with AIS. Although IVT was associated with an increased risk of sICH, no significant increase in 90-day mortality was observed. PROSPERO REGISTRATION: CRD420261304314.

Aged

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Spatial proximity or vector orientation? Re-evaluating ECG interpretation in anterior myocardial infarction using cardiac magnetic resonance.

BACKGROUND: The electrocardiogram (ECG) is widely used to infer infarct location and extent in anterior myocardial infarction (MI), based on either anatomical lead proximity or vectorial orientation of ST-segment deviation. However, the validity of these approaches against direct imaging of myocardial injury remains uncertain. METHODS: In this prospective study, 105 patients with anterior MI underwent cardiac magnetic resonance (CMR) imaging 3-7&#xa0;days after presentation. Admission ECGs were analyzed using (1) conventional ECG localization categories, and (2) simplified frontal and horizontal ST-axis orientation. CMR-defined injury distribution was assessed using late gadolinium enhancement and myocardial edema imaging. RESULTS: Conventional ECG localization categories demonstrated no significant association with CMR-defined infarct distribution (P&#xa0;=&#xa0;0.24), with poor agreement (&#x3ba;&#xa0;=&#xa0;0.122) and substantial overlap across categories. Simplified ST-axis orientation showed modest and inconsistent associations with infarct location and did not meaningfully explain infarct size. In contrast, global ST-segment burden was associated with CMR-defined infarct size (&#x3a3;STE: standardized &#x3b2;&#xa0;=&#xa0;0.307, P&#xa0;=&#xa0;0.002; lead count: standardized &#x3b2;&#xa0;=&#xa0;0.267, P&#xa0;=&#xa0;0.007). CONCLUSIONS: In this selected cohort of reperfused LAD-related anterior STEMI patients undergoing early CMR, conventional ECG localization categories and simplified ST-axis orientation showed poor or inconsistent correspondence with CMR-defined infarct distribution, whereas global ST-segment burden showed a modest association with infarct size. These findings suggest that, in this cohort, the ECG may be better suited to reflect the extent of myocardial injury rather than its precise anatomical location.

Humans

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

The RrWRKY75-mediated activation of ascorbate synthesis in Rosa roxburghii Tratt contributes to salt stress tolerance.

L-Ascorbic acid (AsA) is a key antioxidant that alleviates oxidative stress in plants. Previous yeast one-hybrid (Y1H) screening identified RrWRKY75 as a transcription factor capable of binding to the promoter of RrGGP2 (GDP-L-galactose pyrophosphatase 2), a key structural gene responsible for massive AsA accumulation in Rosa roxburghii fruit. The function of RrWRKY75 in plant stress responses remains unclear. Here, RrWRKY75 is verified to specifically bind to the RrGGP2 promoter and activate its transcription. This positive regulatory effect on RrGGP2 transcript levels and AsA accumulation is further confirmed through overexpression or silencing of RrWRKY75 in R. roxburghii fruit or callus. Among various abiotic stress conditions, RrWRKY75 expression is significantly induced by salt stress. Upon its overexpression in callus or Arabidopsis thaliana, elevated AsA levels and antioxidant capacity are observed, thereby enhancing salt tolerance. Interestingly, RrWRKY75 also binds to the promoter of RrUNE12, a salt-responsive factor in R. roxburghii, and activates its expression. Moreover, yeast two-hybrid and bimolecular fluorescence complementation (BiFC) assays confirm the physical interaction between RrWRKY75 and RrUNE12, which jointly upregulates RrGGP2 expression and AsA production. Collectively, RrWRKY75 boosts AsA biosynthesis and salt tolerance both by directly trans-activating RrGGP2 and by synergizing with RrUNE12 through transcriptional activation and protein complex formation. These findings provide insights into the regulatory role of RrWRKY75 in abiotic stress tolerance and offer valuable genetic resources for R. roxburghii germplasm improvement.

Rosa

Artificial intelligence (AI) uses in stereotactic radiosurgery (SRS): diagnosis with brain metastasis (BM) - A systematic review.

BACKGROUND: Brain metastases (BM) are the most common intracranial tumors in adults, and stereotactic radiosurgery (SRS) has become a mainstay of management. However, several diagnostic challenges persist in the SRS pathway, particularly the differentiation of radiation necrosis (RN) from true tumor progression, which conventional MRI and even advanced imaging techniques often cannot reliably resolve. Recent advances in artificial intelligence (AI) offer the potential to address these diagnostic limitations. This systematic review synthesizes current literature on AI applications for MRI-based diagnostic decision support in BM patients undergoing SRS, with a focus on radiomics and deep learning tools for distinguishing RN from progression, classifying molecular and histologic subtypes, and predicting treatment response. METHODS: A systematic review was performed in accordance with PRISMA guidelines. PubMed, Web of Science, and Scopus were searched using a targeted query combining terms related to AI, brain metastasis, diagnosis or imaging, and SRS. After screening 483 records and applying strict inclusion and exclusion criteria, 18 studies published between 2015 and 2025 were included. Data were extracted on study design, cohort characteristics, imaging modality, AI methodology, validation strategy, and reported diagnostic performance. RESULTS: Among the 18 included studies, AI models demonstrated strong performance across diagnostic tasks in the BM-SRS pathway. The differentiation of RN from true tumor progression was the most extensively studied application, addressed by 14 of 18 studies, with reported AUCs ranging from 0.71 to 0.94. Support vector machines, random-forest ensembles, convolutional neural networks, and transformer-based multimodal architectures were widely used. The literature evolved from single-sequence radiomic classifiers in 2018 to multimodal deep learning frameworks fusing imaging with clinical and genomic data in 2025. Contrast-enhanced T1-weighted MRI was the dominant imaging input, and texture-based radiomic features (GLCM, GLSZM, GLDM, and wavelet-derived features) were the most consistently predictive. The highest-performing models reached AUCs of 0.85-0.91 through multimodal integration of imaging with clinical and genomic features, and consistently outperformed expert neuroradiologist read on matched cases. Remaining studies addressed longitudinal segmentation-based detection of local failure and adverse radiation effects, BRAF mutation status in melanoma BM, early Gamma Knife treatment response, and primary tumor histology classification, with more variable performance. CONCLUSION: AI models, particularly those integrating MRI-derived radiomic features with clinical and genomic data, show high accuracy in supporting diagnostic decisions for BM patients treated with SRS. The post-SRS differentiation of radiation necrosis from true tumor progression has reached the greatest level of maturity and is closest to clinical translation, with potential to reduce unnecessary biopsies, personalize surveillance intervals, and rationalize treatment-pathway decisions. Other diagnostic applications, including molecular subtyping and primary tumor histology classification, remain exploratory and require further multicenter validation. Integration of AI tools into multidisciplinary tumor-board workflows, combined with prospective validation and standardized reporting, will be essential to realize the full clinical benefits of AI in SRS for brain metastases.

Humans

Ketamine Plus Midazolam versus Fentanyl Plus Midazolam for Sedation and Analgesia during Image-guided Procedures in Interventional Radiology: Randomized Clinical Trial.

Background Opioid-benzodiazepine regimens remain common for radiologist-administered procedural sedation despite respiratory and analgesic effectiveness concerns. Purpose To compare intraprocedural pain and patient-reported experience between ketamine/midazolam and fentanyl/midazolam during image-guided procedural sedation. Materials and Methods This randomized clinical trial was conducted at a single academic center between June 2025 and February 2026. Adults undergoing image-guided lung or bone biopsy or abscess drainage were randomized to fentanyl/midazolam or ketamine/midazolam administered by interventional radiologists. Procedures were performed using US, CT, CT fluoroscopy, or combined CT and US guidance. The primary outcome was maximum intraprocedural pain (0-10 on the Numeric Rating Scale). Secondary outcomes included sedation depth, physiologic parameters, oxygen desaturation, patient-reported experience assessed using a modified Heidelberg questionnaire, and complications. Results Among 264 randomized procedures (132 procedures per group) in 260 participants (median age, 68 years [IQR, 61-75 years]; 135 [52%] female), ketamine/midazolam resulted in lower maximum intraprocedural pain than fentanyl/midazolam (mean difference, -1.4 points [95% CI: -2.0, -0.8]; P < .001). Pain scores greater than 4 occurred less frequently with ketamine/midazolam (2.3% vs 17%; absolute difference, 14 percentage points [95% CI: 8, 21]; P < .001). Ketamine/midazolam was associated with higher nadir oxygen saturation (mean difference, +1.4% [95% CI: 0.6, 2.2]; P = .001) and fewer oxygen desaturation events below 90% (three [2.3%] vs 13 [9.8%]; absolute difference, 7.6 percentage points [95% CI: 1.9, 13.3]; P = .02). Ketamine/midazolam produced deeper sedation and higher intraprocedural systolic blood pressure. Hallucinations occurred more frequently with ketamine/midazolam (15 [11.4%] vs five [3.8%]; absolute difference, 7.6 percentage points [95% CI: 1.3, 13.9]; P = .03), though overall procedural comfort, reduced recall, and perceived adequacy of sedation were improved. Procedure-related and sedation-related complications did not differ between groups. Conclusion Radiologist-administered ketamine/midazolam during image-guided procedural sedation improved analgesia and patient-reported experience with fewer hypoxemic events and no increase in complications compared with fentanyl/midazolam. Clinical trial registration no. NCT07040163

Aged

Combining neuromelanin-sensitive MRI and quantitative susceptibility mapping for enhanced diagnosis and differentiation of parkinson's disease: A systematic review.

BACKGROUND: Loss of dopaminergic neurones and iron deposition in the substantia nigra pars compacta (SNpc) are two major pathological hallmarks of Parkinson's disease (PD). Such changes can be visualised by advanced techniques including neuromelanin-sensitive MRI (NM-MRI) and quantitative susceptibility mapping (QSM). This systematic review investigates the diagnostic performance and methodological development of the integrated use of NM-MRI and QSM in PD. METHODS: The systematic search was performed in four databases (Scopus, PubMed, ScienceDirect, and Web of Science) according to the PRISMA 2020 guidelines until July 2026. Bias was assessed using QUADAS-2 and certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies with 2228 participants were included. Combined NM-MRI and QSM consistently showed reduced neuromelanin volume/contrast and increased iron deposition in the SNpc of PD patients compared to healthy controls. Multimodal integration yielded a significant improvement in diagnostic accuracy (AUC values 0.86-0.99), and was able to successfully differentiate PD. Recent methodological advances included simultaneous acquisition sequences (e.g. MTC-GRE, STAGE, setMag) and AI-driven automated segmentation, which led to significantly reduced scan times and improved reproducibility. CONCLUSION: The combination of NM-MRI and QSM has a synergistic effect and provides powerful complementary biomarkers for the diagnosis and differential diagnosis of PD.

Humans