Search PubMedSearch

SEARCH · Search PubMed

Results for “Device compliance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

107 records · Page 3Linked to original sources

Hand Pain and Sensory Deficits: Carpal Tunnel Syndrome: 2026 Revision. Using the Evidence to Guide Musculoskeletal Rehabilitation Practice.

SYNOPSIS: Carpal tunnel syndrome is common in women, manual laborers, and during pregnancy; it is often associated with medical conditions such as obesity and diabetes. The musculoskeletal rehabilitation clinician's approach to managing hand pain and sensory deficits associated with carpal tunnel syndrome should include prescribing a neutral-positioned wrist orthosis plus instructing the patient on how to modify activities, adjust ergonomics, and reduce exposure to risk factors. Here, we present for clinicians the most up-to-date information to guide their work in managing hand pain and sensory deficits associated with carpal tunnel syndrome. J Orthop Sports Phys Ther 2026;56(9):622-623. doi:10.2519/jospt.2026.0502.

Humans

Wearable Sleep Monitoring in Pediatric Acute Lymphoblastic Leukemia: Associations With Subjective Sleep Ratings and Neurocognitive Functioning.

BACKGROUND: Sleep disturbances are associated with increased fatigue, reduced quality of life, and neurocognitive dysfunction and have emerged as a common complication among pediatric cancer survivors. Sleep disturbances are particularly concerning given their potential to exacerbate existing neurocognitive impacts of cancer treatments. This pilot study examined the feasibility and acceptability of a home-wearable EEG-based sleep device (Sleep ProfilerTM) for acute lymphoblastic leukemia (ALL) survivors as well as associations between specific sleep parameters and neurocognitive functioning. PROCEDURE: Children (ages 8-12; M = 10 years, SD = 1.6; N = 23) >6 months post-treatment for ALL were enrolled at clinical visits and wore the Sleep ProfilerTM for two consecutive nights at home, followed by neurocognitive testing of attention, inhibitory control, working memory, and processing speed. Parents completed subjective measures of child sleep, anxiety, depression, and acceptability. Feasibility reflected the percentage of children wearing the device at least one night and the percentage of nights with good EEG quality data. RESULTS: All participants wore the device both nights, with 84% meeting the threshold for good quality measurement. Few children met recommended quantity and quality sleep thresholds based on objective measurement, including 5 patients with elevated snoring levels; 43.5% of subjective ratings fell above the threshold for sleep disturbance. Greater sleep latency was associated with worse inhibitory control (r = -0.42, p = 0.046), and total sleep time was positively associated with inhibitory control and attention. CONCLUSIONS: Findings confirm the feasibility and acceptability of home EEG sleep monitoring in school-age survivors, and associations of sleep latency and snoring with reduced neurocognitive functioning may offer modifiable risk factors for aspects of neuropsychological dysfunction common in pediatric survivorship. CLINICAL TRIAL REGISTRATION: At the time this study was conducted, we were not required to register the study on ClinicalTrials.gov. It was a single-institution feasibility study without intervention, which was not considered a clinical trial.

Humans

Efficacy of targeted neuromodulation treatments: a clinical report.

BACKGROUND: Peripheral neuropathy is a debilitating condition characterized by chronic pain, numbness, tingling, burning, and tightness/swelling. Conventional therapies often focus on symptom management, and some patients experience chronic and refractory symptoms. RESEARCH DESIGN AND METHODS: This retrospective clinical analysis evaluated the clinical outcomes of neuromodulation neuropathy treatment using the NeuroGen-Series device in patients with diabetic peripheral neuropathy (DPN) or idiopathic peripheral neuropathy (IPN). 9,805 unique patients who underwent 133,741 treatments between 18 August 2017, and 23 July 2024, were analyzed. Patients were divided into treatment completers (&#x2265;24 sessions) and noncompleters (<24 sessions). Paired t-tests confirmed statistically significant reductions in pre- and post-treatment symptom scores (p&#x2009;<&#x2009;0.001). RESULTS: Among completers, symptom severity decreased by an average of 46.2%. Tingling and pain showed the greatest improvement, while tightness/swelling and numbness showed the least reduction. 64% of patients reported improvement after one session, and 84% reported improvement after 24 sessions. Nonresponders accounted for 5.8% of patients overall. Younger patients and those with higher initial symptom severity were more likely to discontinue treatment. CONCLUSIONS: Overall, neuromodulation treatment resulted in statistically significant reductions in symptom severity, though nonresponders and high attrition rate highlight the need for individualized treatment strategies and further investigation.

Humans

Initial 4-Year Experience With Microaxial Flow Pumps Within a Tertiary Centre in Regional Australia.

BACKGROUND & AIM: The Microaxial Flow Pump (MFP) is a miniaturised rotary pump that aspirates blood from the left ventricle and expels it into the ascending aorta. It unloads the left ventricle and increases mean arterial pressure and cardiac output. MFP is most commonly utilised in cardiogenic shock, for protected percutaneous coronary intervention (PCI), and for ventricular offloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO). METHOD: We conducted a retrospective review of all patients who underwent MFP insertion at John Hunter Hospital, Australia. Categorical data are represented as counts and percentages, with continuous variables described as means with standard deviations. RESULTS: Twenty-three MFP devices were inserted between September 2020 and May 2024. Five (22%) were for protected PCI, three (13%) for venting with VA-ECMO (ECPELLA), and 15 (65%) for acute coronary syndrome (ACS) and cardiogenic shock. The median age for the overall cohort was 62 years, with a 74% male predominance. Eighty percent of the protected PCI cohort were elective outpatient procedures, and there were no deaths in this cohort. The mortality in the ECPELLA group was 67%. Thirteen (87%) of the patients with cardiogenic shock presented with an anterior infarct, and 53% had cardiac arrest on admission. The overall morality in the cardiogenic shock cohort was 40%. Complications in this cohort included limb ischaemia in four patients (17%) and site bleeding in seven patients (30%). Four patients (17%) required vascular surgery intervention. CONCLUSION: Our initial experience showed the use of MFP in a tertiary centre was safe and feasible, allowing progression from protected percutaneous intervention to acute cardiogenic shock.

Humans

The Effect of Slow Deep Breathing Relaxation Exercise on Pain and Anxiety Levels During and Post-Chest Tube Removal After CABG.

Chest tube removal after coronary artery bypass graft is frequently reported by patients as stressful and painful, highlighting the need for effective nonpharmacological interventions. Slow deep breathing relaxation exercises (SDBREs) may serve as a simple nursing strategy to reduce discomfort. In this study, we aimed to evaluate the effect of SDBRE on pain and anxiety during and after chest tube removal following coronary artery bypass grafting in Nablus hospitals. An experimental design was used with 80 patients recruited from 2 hospitals. Participants were randomly assigned to either an intervention group (n = 40) that practiced SDBRE or a control group (n = 40) that received standard care. Data were collected through a self-administered questionnaire, the Numeric Pain Scale, and the Visual Anxiety Scale. Data collection occurred from March to October 2024. The intervention group reported significantly lower pain scores during removal (M: 5.325 vs 7.125, P < .001) and after removal (P < .001). Anxiety scores were significantly lower both during and after removal (P < .001). Pain correlated with duration, with more complex operations and prolonged chest tube insertion linked to higher scores. SDBRE significantly reduced pain and anxiety during and after chest tube removal, supporting its integration into routine postoperative nursing care.

Humans

Effectiveness and usability of artificial intelligence-powered assistive technologies in Supporting daily activities of children with cerebral palsy: a systematic review.

BACKGROUND: Cerebral Palsy (CP) is the main cause of motor disabilities in childhood, necessitating innovative approaches to rehabilitation and assistive technology (AT). Simultaneously, artificial intelligence (AI) is increasingly being integrated into devices to create more adaptive, personalized, and effective AT. This systematic review aimed to evaluate the effectiveness and usability of AI-powered assistive technologies designed to support daily activities and rehabilitation in children with CP. MATERIALS AND METHODS: Five databases, including Scopus, Web of Science, PubMed, Embase, and IEEE Xplore, were systematically searched, and 23 articles were included in the final analysis. Articles were identified, selected, and categorized into emerging thematic areas based on the primary function and application of the technology. RESULTS: Five key thematic topics were identified: 1) AI-driven motor rehabilitation and gait training for functional mobility; 2) intelligent assessment and monitoring systems for clinical decision support; 3) AI-supported communication, social interaction, and intention recognition tools; 4) gamified and virtual reality-based interventions to enhance engagement and usability; and 5) smart assistive systems supporting daily living and independent mobility. The findings demonstrate a strong trend toward the application of AI technologies in personalized, engaging, and data-driven interventions for children with CP. However, the field is predominantly in the proof-of-concept stage, with limitations including small sample sizes, lack of long-term clinical validation, challenges in user-centered design, and usability for children with CP. CONCLUSION: AI-powered assistive technologies hold significant potential for transforming the care of children with CP by enabling highly personalized and engaging interventions. To actualize this potential, future work must realize that practical application remains challenging owing to limited clinical validation, technological integration, and usability barriers for children with CP. Future research must prioritize user-centered design and multidisciplinary collaboration to ensure that AI and robotic advancements improve the usability and quality of life for children with CP.

Humans

Effects of Vacuum Compression Therapy on Healing of Chronic Lower Limb Ulcers: A Randomised Controlled Study.

Chronic lower limb ulcers remain difficult to manage when unresponsive to conventional treatment. This study evaluated the clinical and physiological effects of vacuum compression therapy on wound healing and quality of life. Fifty patients with chronic lower limb ulcers were randomised to receive 12 sessions of vacuum compression therapy plus standard care or standard care alone over 4&#x2009;weeks. Wound dimensions, exudate, pain intensity and quality of life were assessed at baseline and post-treatment. Estimated wound volume was calculated as length&#x2009;&#xd7;&#x2009;width&#x2009;&#xd7;&#x2009;depth. Tissue oxygenation was measured at the dorsum of the foot in the experimental group. The vacuum compression therapy group showed greater improvements in wound width, depth, volume and quality of life. Estimated wound volume decreased by 61% in the intervention group, whereas no statistically significant volume reduction was observed in controls. Local tissue oxygenation in the experimental group increased by 43%. Baseline wound size was associated with poorer quality of life. Vacuum compression therapy may enhance wound healing and quality of life in patients with chronic lower limb ulcers. Observed increases in local tissue oxygenation represent exploratory physiological findings within the treated cohort that warrant controlled comparative evaluation. Trial Registration: ClinicalTrials.gov identifier: NCT07737184.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Treatment of OSA using mandibular advancement versus CPAP in improving cardiovascular health.

BACKGROUND: Obstructive sleep apnea is a significant risk factor for hypertension. We assessed the relative effectiveness of mandibular advancement device (MAD) versus continuous positive airway pressure (CPAP) in reducing 24 h ambulatory blood pressure (BP) and other health-related outcomes over 12 months. METHODS: In a randomized, non-inferiority trial, 321 participants with hypertension and increased cardiovascular risk were recruited for polysomnography. Of these, 220 with moderate-to-severe OSA (apnea-hypopnea index (AHI) &#x2265;15 events/hour) were randomized to MAD or CPAP (1:1). We report the final outcomes at the 12-month follow-up. RESULTS: A total of 180 participants (MAD: 89; CPAP: 91) completed the 12-month follow-up. Median usage for MAD and CPAP was 5.5 and 4.9 h per night, respectively. Compared to baseline, the 24 h mean arterial BP at 12 months decreased by 2.3 mmHg (P = 0.200) in the MAD group and by 1.0 mmHg (P = 0.999) in the CPAP group. The difference between-groups was -0.6 mmHg (95% confidence interval: -2.53 to 1.39, non-inferiority P < 0.019). The MAD group demonstrated a larger reduction in asleep BP compared to the CPAP group. The prevalence of excessive daytime sleepiness in the MAD group decreased from 30.3% at baseline to 10.1% at 12-month follow-up (P = 0.001), and from 38.5% to 7.7% in the CPAP group (P < 0.001). The between-group difference was 10.6% (P = 0.097). No significant within-group or between-group differences were observed in the prevalence of arrhythmias and plasma levels of cardiac biomarkers. CONCLUSION: At 12-month, MAD is non-inferior to CPAP for reducing 24 h mean arterial BP in participants with hypertension and increased cardiovascular risk. TRIAL REGISTRATION: NCT04119999.

Humans

Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.

BACKGROUND: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. METHODS: Eighteen healthy adults walked on a treadmill at a constant speed (1.1&#xa0;m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. RESULTS: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length (p&#x2009;<&#x2009;0.001) and stance ratio (p&#x2009;=&#x2009;0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition (p&#x2009;<&#x2009;0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg (p&#x2009;<&#x2009;0.001) and foot (p&#x2009;=&#x2009;0.019) when walking with the exoskeleton. CONCLUSIONS: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These&#xa0;results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.

Humans

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

Changes in sexual behavior among women in studies evaluating the dapivirine vaginal ring for HIV prevention.

BACKGROUND: Access to novel HIV prevention technologies often raise concerns of risk compensation. This analysis examined changes in the sexual behaviors of MTN 020/ASPIRE participants, a placebo controlled randomized control trial, who subsequently enrolled in MTN-025/HOPE, an open-label extension using the dapivirine vaginal ring. METHODS: Both studies enrolled healthy, sexually active, HIV-negative women from Malawi, South Africa, Uganda and Zimbabwe. Longitudinal data on participants' sexual behaviors, specifically sex with a nonprimary partner (past 3&#xa0;months), and use of male or female condoms at the last vaginal sex act were compared between ASPIRE and HOPE. Conditional and mixed ordinal logistic regression models evaluated associations between study and sexual behaviors at enrollment,&#xa0;and quarterly over the first 12&#xa0;months. RESULTS: Of the 2629 individuals enrolled in ASPIRE, 1456 (55%) participated in HOPE. At enrollment, the proportion of participants who reported sex with a nonprimary partner and condom use at last vaginal sex act did not differ by study. Across all quarterly follow-up visits, sex with a nonprimary partner was more common in HOPE (13.9-18.7%) than ASPIRE (10.7-12.6%); adjusted OR&#xa0;1.47, 95% CI 1.24-1.75, P&#xa0;<&#xa0;0.001. There was no difference in condom use at the last vaginal act across all quarterly follow-up visits between ASPIRE (36.5-42.7%) and HOPE (43.6-46.7%); adjusted OR&#xa0;1.05, 95% CI 0.94-1.18. CONCLUSION: More women reported sex with nonprimary partners in HOPE, with little change in condom use over time between the two studies. Understanding behavior changes during PrEP use allows for tailored, holistic reproductive health programming.

Humans

Optimizing smoking cessation pharmacotherapy and counseling for adult primary care patients: a factorial randomized controlled trial.

BACKGROUND: Even with the most effective smoking cessation pharmacotherapies (i.e., varenicline or combination nicotine replacement [C-NRT]), the majority of people ultimately return to smoking. This research explored how to optimize the use of varenicline and C-NRT to promote smoking cessation. METHODS: Primary care patients participated in a 2x2x2x2 factorial experiment that evaluated 4 factors: 1) Medication Type (Varenicline vs. C-NRT [patch&#xa0;+&#xa0;mini-lozenge]), 2) Preparation (pre-quit) Medication (4 Weeks vs. Standard); 3) Medication Duration (Extended [24&#xa0;weeks] vs. Standard [12&#xa0;weeks]); and 4) Counseling Type (Cessation Counseling [4 sessions] vs. Referral Support [2 sessions focused on use of referral resources]). This study was discontinued prior to reaching the proposed sample size (N&#xa0;=&#xa0;608) due to pandemic-related budgetary constraints. RESULTS: Participants (N&#xa0;=&#xa0;496) were 55% women and 45.6% Black individuals. There were no statistically significant main effects of the 4 factors on abstinence at 12, 26 or 52&#xa0;weeks. There was a 3-way interaction between Medication Type, Preparation Medication, and Counseling Type (p&#xa0;=&#xa0;0.04) predicting the primary outcome of biochemically confirmed abstinence at 52&#xa0;weeks; cessation counseling vs. referral support improved varenicline quit rates when 4&#xa0;weeks versus 1&#xa0;week of pre-quit medication was offered. For C-NRT, counseling type did not significantly improve quit rates regardless of the use of preparation medication. CONCLUSIONS: There was no robust evidence that enhanced pre-quit or extended duration of varenicline or C-NRT increased abstinence rates. More intensive counseling may support cessation for different pharmacotherapy regimens. Given the lack of consistent findings, this research should be viewed as exploratory to guide future research.

Humans

Does future-oriented imagery rescripting increase willingness to carry out a social anxiety-related behavioral experiment? An extended replication.

BACKGROUND AND OBJECTIVES: Mental images of threat are common in social anxiety disorder and could impede exposure to fear-relevant situations. Landkroon et al. (2022) found that imagery rescripting of anticipated future threat, compared to no-task, increases willingness of non-clinical individuals to conduct a social anxiety-related behavioral experiment. The aim of this two-day preregistered extended replication study was to examine whether the effects persist beyond the intervention session by scheduling the behavioral experiment 1-7 days after the intervention. METHODS: On Day 1, 60 pre-screened participants were asked to design a behavioral experiment to test an idiosyncratic negative belief about a feared social situation. They were then randomly assigned to imagery rescripting (focused on their worst feared outcome of the behavioral experiment) or no-task. Participants' willingness to do the behavioral experiment and their threat beliefs was measured. On Day 2, they were asked to carry out the behavioral experiment. RESULTS: The imagery rescripting group, compared to the control group, did not show increased willingness or compliance to do the behavioral experiment on Day 1 or 2. Furthermore, the imagery rescripting did not lead to greater reductions in threat beliefs on either day. LIMITATIONS: The quality of the imagery rescripting intervention was not assessed, and given the brief nature of the intervention, any effects may have dissipated before participants decided whether to carry out the behavioral experiment. CONCLUSIONS: There was no evidence that imagery rescripting leads to changes in willingness or compliance to do a fear-relevant behavioral experiment. More research is needed to examine interventions that can enhance exposure in socially anxious people.

Humans

Effects of comprehensive oral care on nasogastric tube removal in long-term care residents with dysphagia: A multi-center randomized controlled trial.

Oral care is essential for residents in long-term care (LTC) facilities to reduce complications such as aspiration pneumonia. While routine oral hygiene is standard practice, comprehensive oral care (COC)-which includes facial and intraoral muscle massage, salivary gland stimulation, and oral moisturization-may further enhance swallowing function. However, evidence linking COC directly to nasogastric (NG) tube removal remains limited. This study evaluated the effectiveness of COC in facilitating NG tube removal and improving swallowing function among LTC residents with dysphagia. A multicenter, open-label randomized controlled trial was conducted across eight LTC facilities. The intervention group (n = 40) received daily one-on-one COC sessions lasting 30-40 min, while the control group (n = 37) received routine oral hygiene. Participants were followed for six months, with outcomes including NG tube removal, swallowing function, body weight, and pneumonia incidence. At six months, the COC group demonstrated a significantly higher NG tube removal rate, with eight participants achieving full oral intake (p = 0.005). Functional Oral Intake Scale scores were also significantly higher in the intervention group (p = 0.005). Time to NG tube removal ranged from 17 to 182 days. Under intention-to-treat principles, the NG tube removal rate remained significantly higher in the COC group (16.7%vs. 0%, p = 0.005). Competing risks analysis using the Aalen-Johansen estimator confirmed a 6-month cumulative incidence of NG tube removal of 14.6% in the COC group versus 0% in the control group (Gray's test: p = 0.005), with no significant between-group difference in mortality (p = 0.500). No significant differences were observed in body weight change or pneumonia incidence between groups. Among participants who successfully discontinued NG tube use, dementia was the most common underlying condition. These findings suggest that daily one-on-one COC is a feasible intervention in LTC settings and may improve swallowing function while facilitating NG tube removal in residents with dysphagia.

Humans

Use of Wearable Sensors in Angelman Syndrome: A Systematic Review.

BACKGROUND: Wearable sensors are a promising method for collecting clinical trial outcome data for people with Angelman syndrome (AS). However, there has yet to be a systematic probe into the ways in which wearable sensors have been successfully used in AS. The current study aims to provide a quantitative summary of wearable sensors used in AS, including contexts of use and psychometric properties, and to present key narrative highlights. METHOD: Literature searches were performed in three electronic databases: APA PsycInfo, PubMed and Web of Science Core Collection. Data items were categorized into four categories: sample characteristics, study methodological details, wearable sensor characteristics and psychometric properties assessed. Sample characteristics included sample size, age, biological sex, race/ethnicity and cognitive/developmental functioning. Study methodological details were subdivided into study design and setting. Wearable sensor characteristics included sensor type, placement site, means of attachment, assessed construct and sensor-related data loss. Psychometric properties assessed included reliability and validity of sensor-derived data. RESULTS: We identified 16 articles through our systematic review. Wearable sensors were used to study sleep (n&#x2009;=&#x2009;10, 62.5%), language (n&#x2009;=&#x2009;2, 12.5%), gait (n&#x2009;=&#x2009;2, 12.5%), caregiver proximity (n&#x2009;=&#x2009;1, 6.3%), EEG power (n = 1, 6.3%),&#xa0;and arousal (n&#x2009;=&#x2009;1, 6.3%) in AS through actigraphs, vocalization recorders, inertial sensors, radio-frequency identification watches, wireless EEG caps,&#xa0;and functional near-infrared spectroscopy caps, respectively. Findings from these studies broadly indicate that wearable sensors are feasible, reliable and valid for assessing a range of behaviours relevant to AS. CONCLUSIONS: Wearable sensors are a promising solution to enhance assessments in AS. However, with the small extant literature characterized by small sample sizes and restricted focus on a few relevant features in AS, there remains ample opportunities to explore the use of wearable sensors in people with AS. Additional studies will better inform clinical decision-making and ultimately improve the lives of people with AS and their families.

Humans

Do wound protectors reduce contamination in total shoulder arthroplasty? A randomized controlled trial.

HYPOTHESIS: Cutibacterium acnes is the most frequent cause of shoulder prosthetic joint infection with skin edges as a source of wound contamination. The primary purpose of this study was to determine if the use of a wound protector device decreases the deep wound bacterial colonization in primary shoulder arthroplasty. The secondary purpose was to assess the effect of device usage on deltopectoral muscle and cephalic vein injury. METHODS: This was a prospective, randomized controlled trial. A total of 100 patients undergoing primary total shoulder arthroplasty were enrolled and randomized into 2 groups: a wound protector group and a control group. Five patients withdrew from the study, leaving 48 patients in the wound protector group and 47 controls. Three deep wound culture swabs were taken after final arthroplasty implantation. The surgeon also graded deltoid, pectoralis major, and cephalic vein injury on a 0-3 scale based on modification to the Tscherne classification of soft tissue injury. The primary outcome of this study was positive culture results for C acnes. Secondary outcomes included total bacterial culture positivity as well as soft tissue injury grades. A subanalysis removing likely contaminant positive cultures (growth >7 days and 1 colony only) was also performed. Comparisons between groups were made using Fisher exact test for categorical outcomes and t tests and Mann-Whitney U tests for continuous variables. RESULTS: The use of a wound protector did not result in any significant differences compared with controls in the rate of positive cultures for C acnes (15% vs. 21%, P = .593) or all bacteria (15% vs. 26%, P = .304). Removing likely contaminant positive cultures did not demonstrate any significant difference in culture positivity (9% vs. 17%, P = .355, for C acnes; 9% vs. 19%, P = .231, for all bacterial species). The wound protector group had better soft tissue injury scores for the deltoid muscle (P < .001) and pectoralis muscle (P < .001). No difference in cephalic vein injury was noted between the 2 groups (P > .05). No difference in surgical time was noted. CONCLUSION: The use of a surgical wound protector device in total shoulder arthroplasty did not significantly decrease bacterial colonization of the deep wound. However, soft tissue damage to the deltoid and pectoralis muscle was less severe in the wound protector group. These findings suggest that this device reduces iatrogenic soft tissue injury.

Humans

Effect of urinary catheter securement band on meatal pressure injury in male intensive care patients: A randomized controlled trial.

OBJECTIVES: To investigate the effectiveness of a urinary catheter securement band in preventing meatal pressure injury (meatal-PI) in male ICU patients, and to identify associated risk factors and the timing of injury development. METHODS: A total of 248 adult male ICU patients were randomly allocated to an intervention group (n&#xa0;=&#xa0;124) or a control group (n&#xa0;=&#xa0;124) between December 2024 and April 2025. The intervention group received a catheter securement band in addition to standard care, while the control group received standard care alone. Meatal-PI was evaluated daily using a structured monitoring form and a validated staging system. RESULTS: The incidence of meatal-PI was significantly lower in the intervention group (6.5%) compared with the control group (16.1%) (p&#xa0;=&#xa0;0.016). Multivariate analysis identified catheter securement, use of silicone catheters, higher Braden Scale scores, and shorter ICU length of stay as independent protective factors, while advanced age was associated with increased risk. Additional factors significantly associated with meatal-PI included comorbidities, higher device burden, latex catheter use, dry skin, lower Glasgow Coma Scale and Braden scores, sedation, and perineal oedema (p&#xa0;<&#xa0;0.001). CONCLUSIONS: The use of a catheter securement band significantly reduces the incidence of meatal-PI in male ICU patients. Incorporating catheter securement devices into routine nursing care, prioritising silicone catheter use, and performing regular meatal assessments may enhance patient safety by reducing the risk of device-related pressure injuries. Further research comparing different catheter securement methods across diverse patient populations is warranted. IMPLICATIONS FOR CLINICAL PRACTICE: The use of catheter securement bands may reduce the incidence of meatal-PI in male ICU patients. Incorporating standardized catheter stabilization strategies into routine intensive care nursing practice may enhance patient safety and support pressure injury prevention efforts.

Humans