Search PubMedSearch

SEARCH · Search PubMed

Results for “video-assisted thoracoscopic surgery”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

411 records · Page 2Linked to original sources

Analysis of deep learning techniques in computer-aided diagnosis for meniscus injuries: a systematic literature review.

Meniscus informatics is a growing subject of study in the healthcare industry. One of the major hindrances to the healthcare system's transformation is obtaining knowledge and meaningful information from complicated, high-dimensional and diverse sources. Modern biomedical research, for instance, has seen an increase in the use of complex, dissimilar, poorly documented, and generally unstructured electronic health records, imaging, sensor data and text, even after many current techniques have been used to extract more robust and useful elements from the data for analysis. New efficient standards for building end-to-end learning models from complex data are therefore needed. Therefore, the current study aims to examine the most recent research on the use of deep learning techniques for diagnosing meniscus tears and recommend creating comprehensive and meaningful interpretable structures that might benefit the healthcare industry. We also draw attention to shortcomings and the need for better technique development, and we provide new perspectives about this exciting new development in the field.

Humans

Meta-Analysis of the Efficacy of Ultrasound-Guided Mammotome Minimally Invasive Surgery and Traditional Open Surgery in the Therapy of Benign Breast Tumors.

ObjectiveTo systematically analyze the efficacy of ultrasound-guided mammotome minimally invasive surgery and traditional open surgery in the therapy of benign breast tumors.MethodsA computerized search retrieved original literature on the therapeutic effects of ultrasound-guided mammotome minimally invasive surgery and traditional open surgery for benign breast tumors from authoritative databases, including CNKI, Wanfang, VIP, Web of Science, PubMed, ScienceDirect, Cochrane Library, and Embase. The search covered from database inception to January 2024, using a strategy of subject terms combined with free terms. The retrieved literature was screened, data were extracted, and quality was evaluated. Meta-analysis was performed using RevMan 5.4 software.ResultsA total of 8 literatures were included in the study, and a total of 1909 patients with benign breast tumors were found from 2018 to 2023. The results of meta-analysis showed that the operation time [MD = -12.79, 95%CI (-14.04, -11.55), P < 0.00001], intraoperative blood loss [MD = -11.55, 95%CI (-14.74, -8.36), P < 0.00001], healing time [MD = -2.73, 95%CI (-4.03, -1.43), P < 0.00001] and complication rate [MD = 0.17, 95%CI (0.12, 0.26), P < 0.00001] was apparently different from traditional open surgery (P < 0.05).ConclusionUltrasound-guided mammotome minimally invasive surgery can effectively shorten the operation time of patients with benign breast tumors, reduce intraoperative blood loss, promote healing, and reduce the risk of complications. The effect is better than that of traditional open surgery.

Humans

Beyond da Vinci: a systematic review of next-generation multiport robotic platforms in pediatric surgery.

As robotic surgery expands beyond the da Vinci platform, the relevance of new-generation systems to pediatric patients remains uncertain. This review examined the technical characteristics, applications, and perioperative outcomes of alternative multiport robotic platforms in children. PubMed/MEDLINE, Web of Science, Scopus, and the Cochrane Library were searched through 28 February 2026 in accordance with PRISMA 2020. Owing to clinical heterogeneity, findings were synthesized narratively, with Wilson 95% confidence intervals for key binary outcomes. Six studies reported 166 patients across 27 procedure types. Senhance accounted for 164 patients, while Hugo RAS and Hinotori were each represented by one patient. Ages ranged from 15&#xa0;days to 17&#xa0;years and weights from 3.8 to more than 100&#xa0;kg. Senhance was the only platform used with 3-mm robotic instruments. Conversion or planned escalation occurred in 19 patients (11.4%; 95% CI, 7.5-17.2%). Four intraoperative complications were reported (2.4%; 95% CI, 0.9-6.0%). Across all reports, 20 patients experienced postoperative complications (12.0%; 95% CI, 7.9-17.9%). In the largest cohort, seven patients required reintervention (4.6%; 95% CI, 2.2-9.2%) and seven were readmitted (4.6%; 95% CI, 2.2-9.2%). No deaths or comparative pediatric studies were reported. Published experience remains sparse and is almost entirely limited to Senhance. Current evidence describes early clinical use without establishing comparative safety, effectiveness, or platform superiority. Prospective multicenter studies with standardized reporting are needed.

Humans

Wedge tarsectomy using patient specific instrumentation for complex multiplanar foot deformity Reconstruction: A prospective case series.

BACKGROUND: Bony correction in complex cavovarus deformities is often multiplanar. We examine our results following wedge tarsectomy (WT) using patient-specific instrumentation (PSI). METHODS: This single-centre, prospective case series evaluated noncorrectable cavovarus feet undergoing PSI-guided WT. Accuracy of PSI guides/plans, operative duration, and adjunctive procedures were recorded. Weightbearing CT (WBCT) measurements and PROM scores were recorded preoperatively and postoperatively, with 1 year follow-up. Data was then statistically analysed. RESULTS: Eleven patients were included. Planned correction was achieved (two required minor intraoperative adjustments to the initial osteotomy and nine required adjunctive procedures). Mean operative time was 135&#x202f;min. Postoperative improvements were significant radiologically and in MOxFW walking distance. All fused by 3 months, with no significant complications. CONCLUSION: PSI-guided wedge tarsectomy safely achieves predictable multiplanar corrections. Our unit's experience has been excellent, with improvement in patients' walking, particularly with larger deformity corrections. LEVEL OF EVIDENCE: Level IV, prospective case series.

Humans

Risk factors and management strategies for needle disengagement from the visual field in pediatric robot-assisted laparoscopic pyeloplasty.

OBJECTIVE: This study aimed to identify risk factors for suture needle disengagement from the visual field during pediatric robot-assisted laparoscopic pyeloplasty (RALP) and propose effective strategies for prevention and management. METHODS: A retrospective cohort study analyzed clinical data from 339 pediatric patients who underwent RALP for ureteropelvic junction obstruction (UPJO) at a single institution between August 2017 and December 2020. Patients were categorized based on the occurrence of needle disengagement from the visual field. Various patient demographics and surgical procedural factors were evaluated. Univariate and multivariate logistic regression, along with LASSO regression, identified independent risk and protective factors. RESULTS: Needle disengagement occurred in 38 (11.21%) of 339 cases. Multivariate logistic regression identified five independent risk factors for needle disengagement: use of a 3-mm auxiliary trocar (OR = 4.69, 95% CI: 1.98-12.53, P < 0.001), non-standard needle holder use (OR = 2.32, 95% CI: 1.04-5.18, P = 0.038), unshaped suture needles (OR = 3.16, 95% CI: 1.44-7.19, P = 0.005), simultaneous use of &#x2265;2 intra-abdominal sutures (OR = 2.46, 95% CI: 1.15-5.48, P = 0.023), and clamping the needle shank during withdrawal (OR = 3.42, 95% CI: 1.40-8.21, P = 0.006). Conversely, sufficient assistant experience (>10 cases) was identified as a protective factor (OR = 0.39, 95% CI: 0.18-0.88, P = 0.021). CONCLUSION: Suture needle disengagement from the visual field during pediatric RALP is associated with specific technical and instrumental factors. Implementing targeted strategies-such as mandating specialized needle holders, preoperative needle shaping, a single-needle workflow, prioritizing clamping the suture thread over the needle shank during withdrawal, and ensuring adequate assistant training-has the potential to significantly reduce significantly mitigate the risk of needle loss and enhance overall surgical safety in pediatric RALP.

Humans

Sutureless versus renorrhaphy in robot-assisted off-clamp partial nephrectomy: a systematic review and meta-analysis.

BACKGROUND: The necessity of routine parenchymal renorrhaphy during off-clamp robot-assisted partial nephrectomy (RAPN) remains uncertain. This study aimed to compare perioperative, functional, safety, and oncological outcomes between sutureless and conventional renorrhaphy. METHODS: We conducted a systematic review and meta-analysis following PRISMA 2020 guidelines. Comparative studies evaluating sutureless versus conventional renorrhaphy during purely off-clamp RAPN were included. Trifecta achievement was the primary outcome. Random-effects models were used for pooled analyses, with subgroup analysis according to study design. RESULTS: Four studies involving 787 patients, including one randomized controlled trial (RCT) and three propensity score-matched (PSM) studies, were included. The overall pooled estimate showed no statistically significant difference in Trifecta achievement (RR 1.17, 95% CI 0.97-1.41), with substantial heterogeneity (I&#xb2; = 86.5%). The PSM studies favored the sutureless approach (RR 1.26, 95% CI 1.05-1.52), whereas the RCT yielded an RR of 0.97 (95% CI 0.92-1.04) and met the prespecified noninferiority criterion without demonstrating superiority. The sutureless approach was associated with a smaller perioperative eGFR decline (MD&#x2009;-&#x2009;3.89, 95% CI&#x2009;-&#x2009;6.16 to -&#x2009;1.62), while no significant difference was observed in eGFR at 3 months. No statistically significant differences were identified in major complications, blood transfusion, or positive surgical margins; urinary and vascular complications were sparsely reported. CONCLUSIONS: In selected patients undergoing purely off-clamp RAPN, randomized evidence supports the noninferiority of a strategy that omits routine parenchymal renorrhaphy while permitting clinically necessary selective repair, but does not demonstrate superiority. Favorable estimates from PSM studies remain vulnerable to intraoperative treatment-selection bias. Current evidence is insufficient to determine whether omission of renorrhaphy affects urinary complications, long-term renal function, or oncological outcomes. REGISTRATION: This systematic review was registered prospectively in PROSPERO (CRD420261435995).

Humans

Robot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis.

Robot-assisted percutaneous vascular intervention (R-PVI) has expanded beyond coronary procedures, but previous reviews were largely coronary-focused and observational. Recent randomized controlled trials (RCTs) warrant broader reassessment of R-PVI versus manual percutaneous vascular intervention (M-PVI) across vascular territories. PubMed, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials were searched from database inception to January 31, 2026, following PRISMA guidelines. RCTs and observational studies including &#x2265;10 adult patients in total were eligible. Comparative studies informed primary analyses, while single-arm studies provided supportive evidence. Primary outcomes were clinical success rate and major adverse cardiovascular/cerebrovascular events (MACE) rate. Secondary outcomes included mortality rate, technical success rate, procedural time metrics, contrast volume, and radiation exposure. Random-effects models were used. Forty studies were included: 3 RCTs, 10 comparative observational studies, and 27 single-arm observational studies, comprising 3,870 patients undergoing R-PVI and 1,142 undergoing M-PVI. Comparative analyses showed similar clinical success rates (RR 1.00, P = 0.46), MACE rates (RR 0.72, P = 0.43), and mortality. Single-arm pooled estimates for clinical and technical success were 98.76% and 96.09%, respectively. R-PVI prolonged total procedure time overall (MD 15.92&#xa0;min, P = 0.01), with consistent increases in the neurovascular, RCT, and non-RCT subgroups. Fluoroscopy time was also longer (MD 1.91&#xa0;min, P = 0.04), mainly in the RCT subgroup (MD 2.83&#xa0;min, P = 0.001). In contrast, intravascular intervention time was unchanged overall and in RCTs, but was prolonged in non-RCTs (MD 8.72&#xa0;min, P = 0.006). Operator radiation exposure was markedly reduced (MD -33.97 &#x3bc;Sv, P < 0.001), whereas patient radiation exposure and contrast volume were similar. R-PVI appears feasible and safe across selected vascular procedures. Its clearest benefit is reduced operator radiation exposure, whereas lower whole-procedure efficiency remains its main limitation.

Humans

Delphi study robot consenso: Strategies for the implementation of robotic surgery in general surgery in the Spanish hospital network.

INTRODUCTION: The implementation of robotic surgery in public hospitals presents multiple logistical, educational, and organizational challenges. In the absence of unified guidelines, a national consensus is required to optimize its safe and efficient adoption. This study aimed to establish a set of consensus-based and measurable recommendations for the implementation of robotic surgery programs in hospitals within the Spanish National Health System, based on the experience of centres with established robotic programs and intended to serve as guidance for hospitals that are initiating or planning their implementation. METHODS: A national Delphi study was conducted with the participation of robotic surgery experts from 26 public hospitals. The expert panel was composed exclusively of digestive surgeons with experience in robotic surgery. Three iterative rounds of expert panel evaluation were conducted between March 2024 and March 2025. The questions were grouped into five thematic blocks. Consensus was defined as an agreement level of &#x2265;66.7%. Kendall's W coefficient was used to assess concordance. RESULTS: High levels of consensus were achieved on key aspects related to infrastructure, structured training, cost evaluation, and quality assurance mechanisms. Areas of disagreement were also identified, such as the need for a dedicated anaesthesiologist, purchase of accessory instruments during the initial phase, and official accreditation pathways. CONCLUSIONS: This study provides a guideline for developing a national robotic surgery strategy focused on patient safety, program sustainability, and standardized training of surgical teams. These recommendations can guide hospitals at different stages of robotic technology adoption. Given that the consensus was reached from an exclusively surgical perspective, the recommendations focus on patient safety, program sustainability, and standardized training of the surgical team, and should be interpreted in an adaptable manner according to each centre's context, case volume, and available resources.

Cirug&#xed;a Asistida por Robot

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

Hip Arthroscopy-Assisted Management of Pipkin Types I and II Femoral Head Fracture-Dislocations: Mid-Term Clinical and Radiographic Outcomes.

OBJECTIVES: Hip arthroscopy-assisted surgery has been proposed as a minimally invasive option for femoral head fractures; however, evidence with mid-term follow-up remains limited. This study aimed to evaluate the clinical and radiographic outcomes of arthroscopy-assisted management for Pipkin Types I and II femoral head fracture-dislocations with a minimum follow-up of 5&#x2009;years. METHODS: This retrospective study included 23 consecutive adults (19 Pipkin I and 4 Pipkin II) treated with hip arthroscopy-assisted fragment excision or internal fixation between March 2013 and January 2020. Preoperative computed tomography was used for surgical planning, and fixation was placed with arthroscopic headless screws. Clinical outcomes were assessed using the Harris Hip Score (HHS) and Thompson-Epstein (T-E) criteria. Radiographic evaluation included avascular necrosis (AVN), heterotopic ossification (HO; Brooker), osteoarthritis (OA; T&#xf6;nnis), and fracture reduction quality (Matta's criteria). Group comparisons were evaluated using independent samples t-tests, Mann-Whitney U tests, and Fisher's exact test. The mean follow-up was 86.2&#x2009;&#xb1;&#x2009;21.2&#x2009;months. RESULTS: The cohort consisted of 19 males and 4 females with a mean age of 28.7&#x2009;&#xb1;&#x2009;9.9&#x2009;years. Fifteen patients underwent fixation and eight underwent excision. The final mean HHS was 98.3&#x2009;&#xb1;&#x2009;1.9, with 21 patients (91%) achieving excellent and 2 (9%) good T-E criteria. There were no significant differences between the fixation and excision groups in demographic characteristics, operative time, or functional outcomes (all p&#x2009;>&#x2009;0.05); however, hospital stay was significantly shorter in the excision group (2.9&#x2009;&#xb1;&#x2009;0.6 vs. 5.5&#x2009;&#xb1;&#x2009;4.6&#x2009;days, p&#x2009;=&#x2009;0.028). In the fixation group, mean maximal displacement improved from 7.6&#x2009;mm preoperatively to 2.6&#x2009;mm postoperatively, with anatomic reduction achieved in 6 cases (40%), imperfect in 6 (40%), and poor in 3 (20%). Patients with Pipkin Type I fractures had significantly higher HHS than those with Type II fractures (98.7&#x2009;&#xb1;&#x2009;1.7 vs. 96.0&#x2009;&#xb1;&#x2009;0.8, p&#x2009;=&#x2009;0.018). Complications were rare, with one case of Brooker Grade I HO and one case of mild OA. No AVN or total hip arthroplasty occurred during the follow-up. CONCLUSIONS: Hip arthroscopy-assisted management of selected Pipkin Type I and II femoral head fractures yields excellent mid-term clinical outcomes with acceptable radiographic reduction and a low complication rate. This minimally invasive technique represents a viable alternative in appropriately selected patients when fragment characteristics and surgical expertise permit.

Humans

Robotic-assisted transbronchial biopsy versus computed tomography-guided transthoracic needle biopsy for peripheral pulmonary lesions: a systematic review and meta-analysis of direct comparative studies.

Robotic-assisted bronchoscopy (RAB) and computed tomography-guided transthoracic biopsy (CTTB) are competing strategies for sampling peripheral pulmonary lesions (PPLs). Whether they differ in yield or safety is uncertain. To our knowledge, this is the first systematic review restricted to direct comparisons. We searched MEDLINE, Europe PMC, Scopus, Web of Science and ClinicalTrials.gov from inception to 7 July 2026 for studies directly comparing RAB with CTTB in adults with PPLs. The primary outcome was strict 2024 American Thoracic Society/American College of Chest Physicians diagnostic yield. Risk of bias was assessed with ROBINS-I and certainty with GRADE. A cohort-genealogy step identified, per outcome, the largest set of cohorts sharing no patients; only that set was pooled, with Hartung-Knapp and Mantel-Haenszel sensitivity analyses. Five retrospective studies from one US health system were eligible. Four share patients; at most three cohorts are mutually independent. Across those three, diagnostic yield was comparable (risk ratio [RR] 0.99, 95% confidence interval [CI] 0.93-1.06; I&#xb2;=24%; Hartung-Knapp 0.87-1.13), with an identical relative effect under strict and intermediate definitions although absolute yields fell from 88% to 74-84% under strict criteria. Pneumothorax requiring a chest tube and/or admission was about three-quarters less frequent with RAB across all three cohorts (RR 0.25, 95% CI 0.14-0.46; I&#xb2;=0%; Hartung-Knapp 0.07-0.96). Strict yield (RR 0.99) and any pneumothorax (RR 0.06) were reported by two cohorts each and neither survives the few-studies correction. RAB took about 50&#xa0;min longer than CTTB where same-session staging endobronchial ultrasound was counted in the robotic time, but only about 8&#xa0;min longer than CTTB where it was not. Only one cohort reported yield by lesion size category and none reported yield by bronchus sign or lung zone, so lesion-level subgroups could not be pooled. Certainty was low for pleural complications and very low elsewhere. Low-certainty evidence indicates that RAB is associated with fewer pleural complications, with no statistically detectable difference in diagnostic yield; equivalence was not formally established. Because all evidence is retrospective, confined to one health system, and almost never stratified by lesion size or accessibility, these findings are hypothesis-generating and require a multicenter randomized trial.

Humans

The Effect of Game-Based Virtual Reality Rehabilitation and Its Impact on Upper Extremity Function After Arthroscopic Rotator Cuff Repair: A Randomized Controlled Trial.

BACKGROUND: Arthroscopic rotator cuff repair (ARCR) often results in prolonged recovery and limited shoulder function. Conventional physical therapy rehabilitation programs require sustained patient engagement; however, adherence is frequently low. Game-based virtual reality (VR) offers an interactive and engaging environment that may enhance rehabilitation outcomes. OBJECTIVE: To evaluate the effect of a game-based VR program on the function of the upper limb in patients following ARCR. METHODS: A randomized controlled trial was conducted with patients who underwent ARCR. Participants were randomized into two groups: game-based VR or conventional rehabilitation. Outcomes were evaluated using the Disabilities of the Arm, Shoulder and Hand score, pain severity by the Numerical Pain Rating Scale, range of motion measures, and muscle strength testing. Assessments were performed at baseline and at 6 weeks and 12 weeks post surgery. RESULTS: Results have shown significant within-group improvements in pain, function, range of motion, and isometric muscle strength across all time points (P < 0.05). Between-group analysis revealed greater improvements in pain, function, flexion range, and abduction and external rotation strength in the experimental group at both time points (P < 0.05). Abduction range improved significantly only at 12 weeks (P = 0.02), whereas external rotation range showed no significant difference between groups at either time point (P > 0.05). CONCLUSION: The findings indicate that integrating game-based VR rehabilitation provides additional benefits over conventional therapy in improving pain and upper extremity function following ARCR. These findings support the use of VR as an effective alternative to the conventional rehabilitation for postoperative rehabilitation.

Humans

Alignment strategies in total knee arthroplasty and the patellofemoral joint: A systematic review.

BACKGROUND: Different alignment strategies in total knee arthroplasty (TKA) may affect the patellofemoral joint. Mechanical alignment (MA) is commonly used but may alter native anatomy. Newer strategies such as kinematic alignment (KA), restricted kinematic alignment (rKA), and functional alignment (FA) aim to better restore native joint mechanics. This study provides an overview of the effects of alignment strategies on patellofemoral outcomes after TKA. METHODS: A literature search in July 2025 identified studies comparing patellofemoral outcomes in TKA using different alignment strategies. Of 166 studies screened, eight met inclusion criteria. Three studies were considered medium quality and five studies low quality. RESULTS: KA and rKA more closely restored native trochlear morphology than MA and FA, reducing outliers in the anterior trochlear line compared with MA and FA. MA showed greater trochlear translation, suggesting worse patellar tracking. Trochlear angles were more anatomical in KA and rKA. However, KA was associated with increased internal femoral component rotation and more outliers beyond safe thresholds. FA showed more consistent rotational positioning, generally within safe limits. Lateral patellar shift and intraoperative lateral release rates did not differ significantly between KA and MA. Only one study reported patella-specific clinical outcome scores, finding no difference between FA and adjusted MA. CONCLUSION: KA and rKA better restore trochlear morphology, but risk excessive internal femoral component rotation. FA provides a more balanced approach. MA, while widely used, is linked to altered trochlear shape and worse patellar tracking. The clinical impact of these radiological differences remains unclear, and higher-quality studies are needed.

Humans

The Impact of Video Game Experience on Surgical Performance: A Systematic Review.

OBJECTIVE: To assess whether video gaming experience is associated with improved surgical performance in the surgeon population across laparoscopic, robotic, and other surgical modalities, and evaluate its implications on surgical training and education. METHODS: A structured literature search was conducted across five databases on 29th November 2024 in adherence to PRISMA guidelines. Comparative studies evaluating surgical performance outcome data between surgeons with differing video game experience were eligible for inclusion. Outcomes evaluated were time to complete task, error rate, accuracy, economy of motion, and overall score. Included studies were assessed for risk of bias using ROBINS-I and RoB 2. RESULTS: 15 studies involving 641 participants were included, comprising one randomized controlled trial and 14 nonrandomized studies. All nonrandomized studies were judged to be at moderate or serious risk of bias, and the single randomized controlled trial was judged to be at serious risk of bias. Differences in study design and outcome measures meant that quantitative synthesis could not be performed. Across laparoscopic studies, video gaming experience was associated with improved overall score and time to task completion predominantly in the period prior to structured training interventions, with accuracy findings consistently favoring gamers in the two studies reporting this outcome. Error rate and economy of motion findings were inconsistent or predominantly nonsignificant. No meaningful association was identified across nonlaparoscopic modalities. CONCLUSIONS: Video gaming may be associated with improved surgical performance in surgeons, though this appears restricted to laparoscopic tasks and the pretraining intervention period. As a low-cost and accessible activity, video gaming may represent a practical informal adjunct to formal surgical training to help ease the transition into structured technical training. Surgical program directors need not alter existing selection criteria or training modules based on the available literature.

Video Games

Not just when, but how: An exploratory dual-control approach to video feedback in motor learning.

The present study provides exploratory evidence for a novel dual-control paradigm. It examines whether combining temporal over video feedback timing with learner-controlled interactive playback functions (pause, slow-motion, rewind) would enhance motor skill acquisition beyond temporal autonomy alone. Sixty-four novice adults were randomly assigned to one of four conditions: Full Control (self-controlled timing + interactive replay), Partial Control (self-controlled timing + non-interactive replay), Yoked Full Control (externally controlled timing + interactive replay), or Yoked Partial Control (externally controlled timing + non-interactive replay). Motor accuracy (Radial Error), movement consistency (Bivariate Variable Error), technical execution, and self-efficacy were assessed at pre-test, 24-h retention, and 72-h retention following two acquisition sessions on a dart-throwing task (120 trials total). The Full Control group demonstrated the greatest and most durable learning gains across all outcomes. The Group &#xd7; Time interaction was significant across all dependent variables (&#x3b7;2&#x209a; ranging from 0.140 to 0.234), with Full Control demonstrating superior retention at both 24 and 72&#xa0;h relative to other groups (though differences relative to Partial Control were more pronounced at 72-h retention). Critically, the Yoked Full Control group showed comparatively weaker outcomes despite access to the same interactive playback functions. These findings suggest that interactive video tools may be most useful when learners can regulate both when feedback is accessed and how it is inspected. Theoretical and practical implications for the design of learner-centered video feedback systems are discussed.

Humans

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

Associations Between Short Video Exposure, Empathy and Attitudes Toward End-Of-Life Care Among Nursing Students: A Cross-Sectional Study.

AIM: This cross-sectional study examined the associations between short video exposure, nursing students' empathy, and attitudes toward end-of-life (EOL) care, and tested whether perceived impact is statistically consistent with an indirect pathway in these relationships. DESIGN: A descriptive cross-sectional study. METHODS: In total, 534 undergraduate nursing students were included. Data were collected using a self-designed questionnaire, including the Attitudes Toward Care of the Dying Scale and the Jefferson Scale of Empathy-Health Professions Student version for empathy assessment. Statistical analysis for correlation and mediation analysis (PROCESS macro) was performed. RESULTS: 85.96% of students watch short videos for more than 30&#x2009;min daily, with more than 60% of them viewing EOL-related content. Students with prior caregiving experience or formal palliative care education showed significantly higher empathy and more positive attitudes (p&#x2009;<&#x2009;0.05). Exposure to medical and EOL-related short videos was positively correlated with perceived impact, empathy, and positive EOL attitudes, with effect sizes ranging from very weak to modest (r&#x2009;=&#x2009;0.10 to 0.27). The data were consistent with an indirect pathway between short video exposure and empathy via perceived impact (indirect effect&#x2009;=&#x2009;0.04; 95% bootstrap CI [0.01, 0.08]). However, for EOL attitudes, short video exposure showed a direct association rather than an indirect pathway via perceived impact (direct effect&#x2009;=&#x2009;0.09, p&#x2009;<&#x2009;0.01). CONCLUSION: In this cross-sectional study, short video exposure was modestly associated with nursing students' empathy, with data consistent with an indirect pathway via perceived impact; the observed associations explained only approximately 1% to 7% of the variance in the outcome variables. However, reshaping EOL attitudes may require more systematic education beyond brief video exposure. These findings are hypothesis-generating and await validation through longitudinal and experimental research using standardized video content. IMPLICATIONS FOR NURSING PRACTICE: Nursing educators should consider integrating curated short video content into palliative care curricula to enhance students' empathy and perceived impact of end-of-life education. However, brief video exposure alone may be insufficient to reshape deeper end-of-life attitudes, suggesting the need for comprehensive, multi-modal educational strategies.

Humans

Feasibility and acceptability of skills training in affective recovery (STAR) video and TextSTAR text message program for recent sexual assault survivors.

Background: Sexual assault (SA) affects more than 50% of women in the United States and is associated with elevated risk for impairing posttraumatic stress symptoms and substance, particularly opioid, misuse. Intervening following SA exposure could attenuate these risks.Objective: This study examined the acceptability and feasibility of a 17-minute video, Skills Training in Affective Recovery (STAR) and a 21-day text message program (TextSTAR), that were delivered in the acute post-SA period to prevent the onset or escalation of posttraumatic stress symptoms and substance misuse. The interventions provide psychoeducation about trauma, strategies to reduce fear and avoidance, suggestions to increase social support, and coping strategies for substance use.Method: Participants were 50 women age 18 or older who presented for a Sexual Assault Medical Forensic Exam (SAMFE) within seven days of a SA. Using a Sequential Multiple Assignment Randomized Controlled Trial (SMART) design, participants were randomized to receive the STAR video (n&#x2009;=&#x2009;25) or no video (n&#x2009;=&#x2009;25) at the SAMFE. Those who received the video answered questions about video acceptability immediately after viewing the video. At 1-week post-SAMFE, participants completed online questionnaires about substance use and posttraumatic stress; those above threshold on acute stress or opioid use (n&#x2009;=&#x2009;36) were randomized to TextSTAR (n&#x2009;=&#x2009;18) or no-text program (n&#x2009;=&#x2009;18). Participants completed weekly online surveys 2-4 weeks post-SAMFE about symptoms and text program acceptability.Results: Participants found STAR and TextSTAR at least moderately acceptable; 80% who received STAR found it extremely acceptable while 60-90% (depending on timepoint) who received TextSTAR found it at least moderately acceptable. Our ability to enroll 50 participants and retain 94% at 1 week and 90% at 4 weeks suggests the intervention trial is feasible.Conclusions: STAR and TextSTAR are acceptable and feasible brief interventions for recent sexual assault survivors.Trial registration: ClinicalTrials.gov identifier: NCT06456190.

Humans