Search PubMedSearch

SEARCH · Search PubMed

Results for “performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

825 records · Page 2Linked to original sources

A study on the differences in recovery effects of different types of nutritional supplements on competitive performance of esports athletes under mental fatigue.

BACKGROUND: To compare the effects of different nutritional supplements on the recovery of core competitive performance abilities in esports athletes following mental fatigue and to observe changes in the autonomic nervous system during recovery after nutritional supplementation by monitoring heart rate variability (HRV). METHODS: A randomized crossover within-subject controlled experimental design was adopted, including nutritional supplement type (caffeine, nitrate, Ginkgo biloba extract, catechins, placebo)&#x2009;&#xd7;&#x2009;mental fatigue state (initial, fatigued, post-supplementation). Twenty high-level first-person shooter (FPS) esports athletes were recruited. Mental fatigue was induced using a Stroop task. After ingesting the different supplements and resting for 60&#x2009;minutes, the participants completed assessments of shooting accuracy, shooting stability, spatial localization, and multitasking ability using the KovaaK's simulation trainer. HRV indices were also recorded to evaluate changes in autonomic regulation. RESULTS: For shooting accuracy, compared with the placebo condition, all four supplements significantly improved shooting accuracy scores following mental fatigue (all p&#x2009;<&#x2009;0.05); however, no significant differences were observed among the effects of the different supplements. For shooting stability, caffeine, nitrate, and catechins produced significant recovery effects on shooting stability (all p&#x2009; <&#x2009;0.05); however, no significant differences were observed among the effects of these three supplements. For spatial localization and multitasking ability, the improvements in these two abilities in the post-supplementation state may have resulted from natural recovery, and none of the four nutritional supplements demonstrated a significant recovery effect. The HRV results showed that indices including RMSSD and SDNN changed under some supplement conditions. CONCLUSIONS: Mental fatigue significantly reduced the competitive performance of esports athletes. Four types of nutritional supplements all promoted the recovery of shooting accuracy, while caffeine, nitrate, and catechins promoted the recovery of shooting stability. However, no additional recovery advantages of the nutritional supplements over placebo were identified for spatial localization or multitasking ability. Changes in HRV may reflect changes in autonomic regulation during recovery, but further research is still warranted.

Humans

Effects of acute resistance exercise on prefrontal oxygenation and task-switching performance: Considerations of loading strategies and blood flow restriction.

Although acute resistance exercise (RE) has been proposed to influence cognitive flexibility and underlying neural mechanisms, it remains unclear whether these effects vary across loading strategies and whether exercise-induced prefrontal hemodynamic responses translate into cognitive outcomes. The present study examined (1) prefrontal cortex (PFC) oxygenated hemoglobin (O2Hb) responses across exercise sets and conditions, (2) the effects of low-load (LL), LL with blood flow restriction (BFR), and high-load (HL) RE on task-switching performance, and (3) whether exercise-related PFC O2Hb responses were associated with pre- to post-exercise changes in task-switching performance. Thirty physically active adults completed three randomized, counterbalanced RE conditions consisting of four sets of barbell squats. LL was performed at 30% one-repetition maximum (1RM) with and without BFR, whereas HL was performed at 70% 1RM. Cognitive flexibility was assessed pre- and post-exercise using a modified Stroop task, indexed by switch-cost reaction time (RT) and accuracy. PFC O2Hb was assessed using functional near-infrared spectroscopy during exercise and expressed as changes from the resting baseline for each set (Sets 1-4). PFC O2Hb increased across sets, rising from Set 1 to Set 3 before plateauing, with no differences observed across conditions. Switch cost RT and accuracy did not improve from pre- to post-exercise, and no differences across conditions were detected. PFC O2Hb during the final set was not associated with changes in switch cost. These findings suggest that although acute RE elicits robust increases in prefrontal hemodynamic activity, such responses may not translate into acute improvements in cognitive flexibility.

Humans

Increasing gut short-chain fatty acids protects intestinal barrier function but does not spare muscle glycogen or impact aerobic performance.

Animal studies suggest gut microbiota-derived short-chain fatty acids (SCFA) provide an intestinal barrier-protecting, glycogen-sparing energy source that increases aerobic endurance performance, but confirmation in humans is needed. This study aimed to determine whether increasing colonic SCFA availability impacts intestinal barrier function, substrate metabolism, muscle glycogen and aerobic performance in healthy adults. Using a randomized, double-blind, crossover design 12 active men (age 18-30&#xa0;years;40.0&#xa0;&#xb1;&#xa0;7.1&#xa0;mL/kg/min) performed prescribed exercise and consumed a provided diet supplemented with acetylated and butyrylated high-amylose maize starch engineered to deliver SCFA to the colon (HAMS-A/B) or low-amylose maize starch (LAMS) for 7 days, separated by a 2 week washout. Indirect calorimetry, stable isotopes and blood, muscle and urine biomarkers were measured on intervention day 8 while participants completed 90&#xa0;min of steady-state cycle ergometry (ExSS; 60 &#xb1; 5%) followed by a 5&#xa0;km treadmill time trial. HAMS-A/B, relative to LAMS, increased faecal and serum SCFA. Multiple markers of intestinal barrier damage and permeability were lower, and the respiratory exchange ratio during ExSS was higher (0.02 [95% confidence interval (CI): 0.01, 0.03], Ptreatment&#xa0;<&#xa0;0.001) following HAMS-A/B versus LAMS. However no between-treatment difference in glucose turnover, muscle glycogen depletion (14&#xa0;&#xb5;mol/kg/g dry wt. [95% CI: -116, 143], Pinteractio n&#xa0;=&#xa0;0.613) or TT performance (5&#xa0;s [95%CI: -44, 54], Ptreatment&#xa0;=&#xa0;0.816) was observed. Increasing colonic and circulating SCFA modestly altered substrate oxidation and preserved intestinal barrier function during endurance exercise. However effects were not sufficient to spare muscle glycogen or increase aerobic endurance performance, leaving the practical relevance unclear and underscoring challenges inherent in translating promising preclinical findings to humans. KEY POINTS: Animal studies suggest gut microbiota-derived short-chain fatty acids (SCFA) provide an intestinal barrier-protecting, glycogen-sparing energy source that increases aerobic endurance performance, but confirmation in humans is lacking. A gut microbiota-targeted dietary supplementation strategy was used to deliver SCFA to the colon and successfully increased colonic and systemic SCFA concentrations in healthy, physically active adults before and during an endurance exercise bout and aerobic performance test. Increasing colonic and systemic SCFA availability preserved intestinal barrier function but did not impact glucose turnover, alter protein expression in muscle or spare muscle glycogen during endurance exercise. Increasing colonic and systemic SCFA availability did not impact aerobic endurance performance.

Humans

Clinical performance evaluation of single-shade versus multi-shade composite resins in non-carious cervical lesions: a 36-month randomized clinical trial.

BACKGROUND: Composite resins are widely used as the material of choice for definitive restorations due to their ability to integrate functional and aesthetic aspects in dental rehabilitation. Recently, one-shade composite resins have been introduced to simplify the clinical workflow. OBJECTIVES: This study aimed to compare the clinical performance of a "chameleon effect" composite resin with that of a multi-shade composite resin in non-carious cervical lesions after 36 months of follow-up. METHODS: This study was a randomized, controlled, double-blind clinical trial with an equivalence design using a split-mouth approach. The sample consisted of 60 patients presenting at least two non-carious cervical lesions, totaling 120 restorations. Restorations were performed using two materials from the same commercial brand: Vittra Unique (one-shade group) and Vittra APS (multi-shade group). The clinical performance of the restorations was longitudinally evaluated according to the FDI criteria. Survival analysis was performed using Kaplan-Meier curves and the log-rank test, while other clinical parameters were compared using the chi-square test (&#x3b1; = 0.05). RESULTS: At baseline, no statistically significant differences were observed between the groups regarding the evaluated biological, functional, and aesthetic parameters (p > 0.05). Both materials demonstrated clinically acceptable performance according to the FDI criteria, with no significant differences between them. CONCLUSIONS: After 36 months, no significant differences were observed between the one-shade and the multi-shade composite resins in the restoration of non-carious cervical lesions. CLINICAL SIGNIFICANCE: This 36-month randomized clinical trial demonstrates that single-shade composite resins achieve structural durability and aesthetic integration equivalent to traditional multi-shade layering when restoring non-carious cervical lesions. This evidence validates a simplified, single-shade restorative workflow, significantly reducing chairside time and operator-dependent variables without compromising the clinical longevity.

Humans

Nondominant Hand Training in Laparoscopy for Surgical Interns: Feasibility and Impact.

OBJECTIVE: Laparoscopy requires bimanual proficiency, yet early trainees demonstrate underdeveloped nondominant hand (NDH) performance. Although deliberate practice of NDH skill contributes to overall performance, NDH training is rarely incorporated into residency simulation curricula and has not been formally evaluated in surgical trainees. We assessed feasibility and impact of integrating structured NDH training with established laparoscopic curriculum for surgery interns. DESIGN: Prospective, single-institution randomized pilot study. Interns were assigned the standard 4-week curriculum of laparoscopic dominant hand and bimanual tasks (Control) or completed assigned NDH tasks in addition to the standard curriculum (Intervention). Feasibility was determined by assigned task completion, daily standard and NDH-specific self-reported practice time, and improvement in bimanual task performance. Performance was video recorded weekly and assessed by blinded evaluators using MISTELS and GOALS scoring. Cognitive workload during laparoscopic tasks was measured via NASA-TLX. Exploratory analyses were conducted within a Bayesian framework. SETTING: A single academic institution with a surgical simulation training program. PARTICIPANTS: General surgery interns on their 4-week simulation rotation. RESULTS: Eleven general surgery interns (6 intervention, 5 controls; all right-hand dominant) completed the study with 100% task completion and practice log compliance. Both groups improved in bimanual performance and perceived cognitive load. Reduction in cognitive workload during bimanual task performance was greater in the NDH group. Time spent on NDH practice over 4 weeks was associated with improved bimanual performance, independent of time spent on standard curriculum tasks. CONCLUSIONS: Structured NDH training is feasible to implement within an existing curriculum and reduces perceived cognitive workload during bimanual laparoscopic tasks. NDH practice demonstrates a beneficial dose-response relationship with performance, supporting its integration into early laparoscopic training.

Laparoscopy

Systematic review of microorganism disinfection performance by chemical and ultraviolet light water treatment methods.

Safe drinking water is critical for public health, yet microbial contamination remains a significant global challenge. We conducted a systematic review to update World Health Organization guidance on water disinfection technologies by synthesizing peer-reviewed literature from 1997 to 2021 on the performance of free chlorine, chlorine dioxide, ozone, and ultraviolet (UV) light against bacteria, viruses, and protozoa. Following PRISMA guidelines, we analyzed log10 reduction values (LRVs) and contact times (Ct) or fluence (for UV) from laboratory and field studies. We included studies from multiple databases and expert-recommended studies. Results show mean Cts for 2 LRV of non-opportunistic bacteria as 6.0 (free chlorine), 0.4 (chlorine dioxide), and 1.2 (ozone) mg/L*min, and a mean UV fluence of 8.2 mJ/cm&#xb2; (all bacteria). Viruses required lower Cts, except for UV-resistant adenoviruses, while protozoa required higher Cts or fluences. Opportunistic bacteria required significantly higher Cts than non-opportunistic bacteria for free chlorine and chlorine dioxide. Temperature and pH effects were inconsistent, highlighting data variability and gaps in field studies. These findings support global guidance on water treatment and may be used alongside other context-specific data to understand the roles these technologies play in reducing waterborne exposures. We recommend standardized reporting from performance studies to enable straightforward synthesis of evidence.

Disinfection

Effects of carbohydrate mouth rinse on psychophysiological responses, kinematic variables and technical actions during small-sided soccer games.

BACKGROUND: This study investigated the effects of carbohydrate mouth rinsing (CHOMR) on various psychophysiological, kinematic, and technical actions during 4-a-side small-sided soccer games (SSGs). METHODS: In a randomized, crossover, double-blind design, 16 young male soccer players (age: 15&#x2009;&#xb1;&#x2009;1 years; height: 172.6&#x2009;&#xb1;&#x2009;7.0&#x2009;cm; body mass: 57.8&#x2009;&#xb1;&#x2009;7.9 kg) participated in two 4-a-side SSGs separated by one week following either CHOMR or placebo (PLA). During each SSGs, heart rate (HRmean, %HR, and HRmax), rating of perceived exertion (RPE), enjoyment, visual analogue scale (VAS) to perceived mental fatigue, mood states, total distance (TD), high-speed running distance (HSRD), average metabolic power (AMP), high metabolic load distance (HMLD), sprint distance (SD), acceleration (ACC), deceleration (DEC), and technical actions (e.g. passing, tackling, shooting, and interceptions) were assessed. RESULTS: Compared with PLA, CHOMR resulted in significantly higher RPE (p&#x2009;=&#x2009;0.025, g&#x2009;=&#x2009;0.86) and significantly lower VAS scores (p&#x2009;=&#x2009;0.010, g&#x2009;=&#x2009;-0.71). In addition, the CHOMR condition showed significantly higher values for interceptions, successful tackles, unsuccessful tackles, unsuccessful shots, and goals (p&#x2009;<&#x2009;0.05, g&#x2009;=&#x2009;0.96-2.02), whereas block values were significantly higher in the PLA condition. There were no statistically significant differences in HRmean, %HR, HRmax, enjoyment, TD, HSRD, AMP, HMLD, SD, ACC, DEC, successful passes, unsuccessful passes, successful shots, or mood states between the conditions (p&#x2009;>&#x2009;0.05). CONCLUSION: The current study findings suggest that CHOMR may enhance selected technical actions and lower VAS scores during 4-a-side SSGs, although it was also associated with higher RPE and did not alter the kinematic responses. In conclusion, CHOMR was associated with higher RPE, lower mental fatigue, and selective improvements in technical actions, with no significant effects on kinematic variables or HR.

Humans

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and &#x3ba; statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years &#xb1; 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (&#x3ba; = 0.57-0.96) and clinical T categorization (&#x3ba; = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (&#x3ba; = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper

Diagnostic performance of machine learning models for malignant and non-malignant pleural effusion: Systematic review and meta-analysis.

BACKGROUND: Accurately distinguishing malignant pleural effusion (MPE) from non-malignant pleural effusion is clinically important, but the generalisability and methodological quality of machine-learning (ML) models remain uncertain. METHODS: We searched eight databases to 23 April 2026. Diagnostic performance was pooled using random-effects and Reitsma bivariate models, and study quality was assessed using PROBAST+AI. RESULTS: Forty-two studies were included; 17 contributed to the AUC meta-analysis and 14 to the bivariate analysis. The pooled AUC was 0.90 (95&#xa0;% CI 0.85-0.94; 95&#xa0;% prediction interval 0.62-0.98), with sensitivity of 0.80 (95&#xa0;% CI 0.77-0.83) and specificity of 0.87 (95&#xa0;% CI 0.79-0.92). Only nine studies reported external, temporal or independent validation. Externally validated studies had a lower pooled AUC than studies without external validation (0.83 vs 0.92), with lower specificity observed in the two externally validated studies contributing sensitivity and specificity data. All 42 development assessments had high overall quality concerns, and all 42 model evaluations were judged at high risk of bias. CONCLUSIONS: ML models showed good apparent accuracy for distinguishing MPE from non-MPE, but the evidence was limited by substantial heterogeneity, high risk of bias and scarce external validation. The pooled estimates reflect the average performance of different selected models rather than the expected accuracy of a single clinical test. ML models should be regarded as adjuncts to existing diagnostic pathways until they are confirmed by rigorous multicentre prospective external validation and clinical-impact studies.

Humans

An Assessment of Reliability Estimation Methods for Binomial Health Care Quality Measures.

We evaluated the performance of commonly used methods for estimating the reliability of binomial health care quality measures using simulated datasets spanning a range of performance score means and variances, numbers of entities, and patient sample sizes. For each simulation, reliability was estimated for all selected methods and compared with the known true reliability derived from the simulation parameters, with methods assessed on their accuracy and precision. Logistic regression with reliability estimated on the outcome scale demonstrated the highest accuracy and precision among all methods evaluated. The widely used Adams beta-binomial method performed poorly, although a modification recommended by Nieser and Harris substantially improved its performance. These approaches are applicable only to binomial measures. Among methods that can be applied to both binomial and continuous measures, permutation resampling of the Spearman rank correlation coefficient was the most accurate and precise, outperforming other commonly used approaches. Overall, for binomial quality measures, logistic regression on the outcome scale is the preferred method for reliability estimation, followed closely by the modified beta-binomial approach, while for non-binomial measures, permutation-based Spearman rank correlation appears to be the most suitable method.

Reproducibility of Results

Performance of Automated Hematology Analyzer Criteria in Detecting Peripheral Blood Smear Abnormalities: A Systematic Literature Review.

OBJECTIVES: Criteria for visual examination of stained peripheral blood smear (PBS) differ among institutions in the United States and internationally. In an effort to standardize review criteria, the International Consensus Group for Hematology Review (ICGHR) proposed in 2005 a consensus list of rules for CBC findings that should trigger a review of automated cell counter results and potentially lead to further testing or blood smear review. The primary aim of this paper is to report on the published literature in the past 20&#x2009;years regarding PBS review criteria and their ability to identify relevant peripheral blood abnormalities. METHODS: We performed a systematic review of the published literature from 2005 to 2025 to investigate and summarize PBS review criteria and performance in the context of automated hematology analyzers in clinical laboratories. RESULTS: Of 5351 citations, 68 studies met our search criteria. These studies included 22 countries and all major hematology analyzer manufacturers. Marked variability was observed in study populations, analyzer flagging criteria, details of PBS visual review, definitions of a "positive" smear, and approaches to statistical data analysis. Across studies, the blast flag sensitivity ranged from 18% to 100% while the blast flag specificity ranged from 17% to 100%. Wide ranges in sensitivity/specificity were also seen for atypical and/or abnormal lymphocyte flags across studies. For studies analyzing the same patient population, less striking variation was seen across instruments. CONCLUSIONS: This systematic review provides a 20-year overview of the literature, highlighting significant variability in PBS review criteria, dependence on study design and hematology analyzer, and the importance of developing harmonized evidence-based guidelines.

Humans

External load metrics and monitoring in women's football match play: A systematic review.

This systematic review aimed to identify the most commonly used variables for monitoring external load during elite women's football matches and to compare reporting practices internationally and in Brazil. Searches were conducted in Web of Science, PubMed, and SciELO using the PICOS framework between February and March 2026, resulting in the inclusion of 35 studies. The main outcomes analysed were total distance covered (TD), distance covered across speed zones (HSR, VHSR, sprint), number of accelerations and decelerations, and maximum speed. TD and distance covered across speed zones were the most frequently reported indicators (94.3%), followed by HSR (82.8%) and sprint distance (68.5%). Considerable variability was observed in the classification of speed zones and thresholds used to define accelerations and decelerations, limiting comparisons between studies. External load values varied according to playing position and competition level, with international matches generally imposing greater demands than national competitions. Brazilian research remains limited and demonstrates notable methodological variability. This review proposes standardised speed and acceleration/deceleration thresholds based on the most recurrent ranges reported in the literature, supporting improved consistency in monitoring practices across elite women's football contexts.

Humans

Influence of microplastics on microalgal performance during wastewater polishing.

Microplastics (MPs) are emerging contaminants that are increasingly accumulating in aquatic ecosystems due to excessive anthropogenic activity and insufficient mitigation strategies, posing serious environmental and public health risks. Their impact on wastewater (WW) treatment processes remains poorly understood. This study evaluated the effects of five MPs commonly found in WW - polypropylene, polystyrene, polyamide, low-density polyethylene, and high-density polyethylene - on the physiology and bioremediation performance of the microalga Chlorella vulgaris in synthetic WW (SWW). Metabolic responses were assessed via esterase activity and intracellular reactive oxygen species (ROS), while nitrogen (N), phosphorus (P), and glucose removal were monitored to evaluate bioremediation efficiency. MPs inhibited esterase activity and elevated ROS levels, indicating oxidative stress. Nevertheless, C. vulgaris maintained a high bioremediation capacity (> 75 % N, > 60 % P, and > 70 % for glucose). Environmental conditions modulated microalga response to MPs exposure. Under N-limited conditions, C. vulgaris exhibited enhanced nutrient uptake and biomass production, but a 12 h/12 h light/dark photoperiod reduced N removal but stimulated glucose consumption via heterotrophic metabolism. In contrast, C-limited conditions exacerbated oxidative stress and compromised nutrient removal, resulting in residual concentrations exceeding legal limits. These findings highlight that environmental factors can either mitigate or exacerbate the physiological stress induced by MPs, ultimately affecting WW polishing. This work provides a comprehensive insight into the cellular and metabolic effects of MPs on microalgae and supports C. vulgaris as a resilient and sustainable approach for nutrient and carbon removal in MP-contaminated WW systems.

Microalgae

Prenatal exposure to indoor PM2.5 and children's cognitive performance at 4 years of age: an observational analysis from the UGAAR randomized controlled trial.

Outdoor fine particulate matter (PM2.5) concentrations during pregnancy are linked to reduced cognitive performance in children. We previously reported that portable HEPA filter air cleaners use during pregnancy improved children's mean full-scale IQ (FSIQ), but no previous studies have evaluated the relationship between indoor PM2.5 during pregnancy and FSIQ in childhood. We conducted an observational analysis using data from the Ulaanbaatar Gestation and Air Pollution Research (UGAAR) randomized controlled trial. Using a previously developed model of weekly indoor PM2.5 concentrations, we estimated the average concentrations in participants' homes over the full pregnancy and in each trimester. When the children were four years old, we measured FSIQ using the Wechsler Preschool and Primary Scale of Intelligence (WPPSI-IV). We used multiple linear regression to assess the adjusted relationships between interquartile range (IQR) contrasts in indoor PM2.5 during pregnancy and FSIQ among 475 mother-child dyads. An 8.8&#xa0;&#x3bc;g/m3 increase in indoor PM2.5 concentration over the full pregnancy was associated with a reduction of 1.4 points (95% CI: -3.4, 0.6) in mean FSIQ. The strongest association between PM2.5 concentrations and FSIQ was in the first trimester, when a 19.1&#xa0;&#x3bc;g/m3 contrast was associated with a 2.8-point reduction (95% CI: -5.7, 0.2) in mean FSIQ. Indoor PM2.5, particularly during early pregnancy, may impair brain development, leading to lower mean FSIQ scores in four-year old children. These results, combined with our previous analysis of HEPA filter air cleaners, indicate that reducing PM2.5 exposure during pregnancy has beneficial effects on children's cognitive performance.

Humans

Natural deep eutectic solvent in situ formation-based extraction method coupled to high-performance anion-exchange chromatography with pulsed amperometric detection for multiclass carbohydrates in hot pot bases.

A novel method was developed for the simultaneous extraction of fourteen multiclass carbohydrates from high-fat foods via the in situ formation of deep eutectic adducts from analytes and acetate ions. Different natural deep eutectic solvents (NADESs) composed of fructose and organic acids were tested as extraction solvents. A model NADES formulated with sodium acetate and fructose was characterized using Fourier transform infrared (FTIR) spectroscopy and hydrogen nuclear magnetic resonance (1H-NMR) spectroscopy. The critical extraction parameters were systematically optimized using multi-response surface methodology (MRSM) with a central composite design (CCD). The extract was analyzed using high-performance anion-exchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD) using a sodium hydroxide-sodium acetate eluent, which did not require organic solvents. This approach exhibited good linearity over the concentration range of 0.02-10 mg L-1, with correlation coefficients (r) ranging from 0.9994 to 0.9999. The limits of detection and quantification were in the ranges of 0.06-0.42 mg kg-1 and 0.19-1.3 mg kg-1, respectively, which were significantly lower than those of liquid chromatography (LC). The protocol was successfully applied to the determination of fourteen carbohydrates in forty-five hotpot seasoning samples. The recoveries ranged from 86.3% to 104.1%, with relative standard deviations (RSDs) of 0.9-7.1%. By integrating multiple techniques, this strategy simplifies operations, shortens extraction time, and achieves baseline separation of three carbohydrate classes that exhibit poor resolution using a conventional LC method. This study describes an efficient procedure for the simultaneous determination of multiple trace-level carbohydrates in complex samples using HPAEC-PAD.

Journal Article

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans