Search PubMedSearch

SEARCH · Search PubMed

Results for “medical devices in Europe”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,959 records · Page 2Linked to original sources

Policy pathways and historical insights: Canada's evolving approach to psychedelic access for end-of-life distress.

Canada's evolving attitudes toward psychedelic interventions in palliative and end-of-life care reflect a departure from historically prohibitionist policies and an emerging recognition of their therapeutic potential for individuals facing end-of-life distress. This shift parallels international regulatory developments in jurisdictions such as the United States, Australia and parts of Europe, where cautious policy liberalization has signaled growing acceptance of psychedelics within clinical contexts. Canada is also a relevant case because of its formative role in the development of modern palliative care, its contemporary frameworks emphasizing holistic approaches to suffering at the end of life, and its experience with medical assistance in dying, all of which have shaped national conversations about suffering, autonomy, and end-of-life care. Additionally, Canada's distinctive historical approach to drug regulation-marked by federal flexibility, mechanisms for compassionate access, and responsiveness to patient advocacy-combined with rising public demand and incremental provincial changes, may uniquely position the country along a transitional pathway toward clinical integration of psychedelics in palliative care. At the same time, Canadian drug policy remains heterogeneous across substances and provinces, underscoring the political contingency of reform. Within this dynamic landscape, Canada's psychedelic drug policy trajectory aligns with broader international trends toward cautious medicalization and regulated access to psychedelic therapies, while also offering an instructive case for how end-of-life frameworks and federal-provincial governance shape policy development.

Humans

Access to maternity services for women asylum seekers and refugees: A transnational document analysis of international, European regional, and United Kingdom governance.

Women asylum seekers and refugees face persistent barriers to maternity care (antenatal, intrapartum and postnatal care) across high-income countries, yet the upstream governance shaping access remains under-examined. Although legally distinct, both groups share protection-seeking experiences and are addressed jointly in governance documents. This study examined and synthesised how international (macro), European regional (meso), and United Kingdom (UK, micro) governance documents frame and operationalise maternity service access. Sixty-four documents were analysed using the READ framework. Inductive analysis of macro and meso documents identified six access dimensions: universal coverage; cultural and linguistic adaptation; rights-based approaches; multi-agency collaboration; data, monitoring and accountability; and quality of care. These dimensions structured assessment of UK governance, with jurisdictions rated strong, moderate or weak. Alignment was fragmented: Wales, Scotland and Northern Ireland exempted asylum seekers from charging, whereas England retained charging provisions. Multi-agency collaboration was consistently articulated, yet none of the 35 UK government documents focused on maternity access for this population, and none required outcome monitoring disaggregated by asylum or refugee status. UK governance appears coordinated in form but fragmented in substance. UK-wide minimum standards and routine recording of these data, with safeguards against immigration-related use, could strengthen coherence and accountability and improve visibility of inequities.

Refugees

Genital surgery in children with differences of sex development (DSD): Strengths and concerns across diverging regulations in four European countries.

Differences of Sex Development (DSD) is a collective term for a heterogeneous group of rare congenital conditions characterized by atypical genetic, gonadal, or genital sexual development. The treatment of children with DSD, particularly the indications for and timing of surgical interventions, has been the subject of debate for decades. In recent years, social developments emphasizing children's rights to self-determination and bodily integrity, along with increasing societal acceptance of atypical sex characteristics, have encouraged a more cautious approach toward early genital surgery in children with DSD. In 2019, the European Parliament adopted a resolution urging Member States to enact legislation prohibiting elective genital surgical interventions on intersex infants and children. Since then, several countries have indeed implemented restrictive measures, including legal bans on early surgical procedures. In this paper, we share the experiences and insights gained in recent years as pediatric urologists working in four neighboring countries in multidisciplinary university centers specializing in DSD care and research. We focus on current approaches to the care of children with DSD, the evolution of relevant national policies over time, and the nature and impact of recently introduced restrictive regulations on early surgical interventions. By presenting perspectives from pediatric urologists across these four countries, we aim to contribute to ongoing discussions on the alignment and refinement of surgical treatment practices for children with DSD.

Humans

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16 weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Effect of Music on Pain, Anxiety, and Satisfaction During Intrauterine Device Application: A Randomized Clinical Trial.

This randomized controlled trial aimed to determine the effect of music played during intrauterine device (IUD) insertion on perceived pain, state anxiety, and satisfaction levels. The study was conducted with 70 women who applied to a maternal and child health and family planning center and were randomly assigned to the intervention and control groups using simple randomization. Data were collected using a Demographic Information Form, the State-Trait Anxiety Inventory (STAI-I), and the Visual Analog Scale (VAS), as well as Bluetooth speakers and the musical piece Evgeny Grinko-Valse. Participants in the intervention group listened to music before and during the IUD insertion procedure, whereas the control group received routine care only. Data were analyzed using SPSS version 26 with appropriate descriptive and inferential statistical methods. Women in the music group had significantly lower perceived pain (p&#x2009;<&#x2009;0.001) and state anxiety levels during the procedure (p&#x2009;=&#x2009;0.022), and significantly higher satisfaction levels compared with the control group (p&#x2009;<&#x2009;0.001). In addition, post-procedure state anxiety levels were positively correlated with pain intensity experienced during and after the procedure (r&#x2009;=&#x2009;0.542 and r&#x2009;=&#x2009;0.496, respectively; p&#x2009;<&#x2009;0.001), and negatively correlated with procedural satisfaction (r&#x2009;=&#x2009;-0.652; p&#x2009;<&#x2009;0.001). These findings suggest that listening to music during IUD insertion may help reduce pain and anxiety while potentially enhancing patient satisfaction. Trial Registration: NCT06215183.

Humans

ESC quality indicators for post-myocardial infarction care: transition and chronic coronary syndrome phases.

AIMS: We aimed to develop the European Society of Cardiology (ESC) quality indicators (QIs) for myocardial infarction (MI), from 1 year after hospital discharge, corresponding to transition to the chronic coronary syndrome phases. METHODS AND RESULTS: We collaborated with the European Association of Preventive Cardiology (EAPC) and developed QIs for the long-term management of patients following MI. We applied the ESC methodology for QI development by (i) determining key domains of post-MI care; (ii) developing candidate QIs by performing a systematic review of the literature, and (iii) selecting the final set of QIs using a modified Delphi approach. In total, 18 QIs were identified across seven domains of care including (i) structural framework, (ii) risk assessment and follow-up, (iii) pharmacological management, (iv) rehabilitation, behavioural, and preventive interventions, (v) coronary revascularization, (vi) clinical outcomes, and (vii) patient-reported outcomes. CONCLUSION: We present the ESC QIs from 1 year after hospitalization for MI, to standardize and address gaps in care for this high-risk group. These QIs are supported by evidence from contemporary literature, endorsed by expert consensus, and aligned with the 2024 ESC guidelines on the management of chronic coronary syndromes. LAY SUMMARY: Measures to evaluate and improve the long-term management of patients following a heart attack are needed. In this paper, we identified key aspects of care that can help clinicians, decision-makers and patients improve the quality of care, from one year after a heart attack onwards, and help address inequalities and variations in clinical practice.

Humans

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Phase 1 Study Evaluating Gefurulimab Pharmacokinetics and Safety Following Delivery Via Autoinjector or Prefilled Syringe With Needle Safety Device in Healthy Adults.

PURPOSE: Gefurulimab, a novel dual-binding nanobody targeting complement component 5 (C5), is in clinical development for anti-acetylcholine receptor antibody-positive generalized myasthenia gravis. Gefurulimab has a low molecular weight, enabling subcutaneous (SC) self-administration by autoinjector (AI) or prefilled syringe with needle safety device (PFS-SD). We compared gefurulimab pharmacokinetic (PK) exposure and safety in healthy adults following a single SC dose administered by AI versus PFS-SD. METHODS: In this phase 1, open-label, randomized, parallel-group study (NCT06208488), healthy participants aged 18 to 65 years were stratified by weight and randomized equally to 1 of 6 combination groups of device and injection site (abdomen/thigh/upper arm). Participants received a single SC dose of gefurulimab on day 1 and were assessed throughout the 92-day evaluation period. Primary endpoints were PK parameters for each device: maximum observed concentration (Cmax) and area under the serum concentration-time curve (AUCinf, AUClast). PK across injection sites, pharmacodynamics, safety, immunogenicity, and device performance were also assessed. FINDINGS: Overall, 175 participants were randomized: AI (n = 87), PFS-SD (n = 88). Geometric least squares mean ratios (90% CI) comparing AI/PFS-SD for Cmax, AUCinf, and AUClast were 97.6% (94.5-100.8), 99.6% (96.1-103.3), and 98.8% (95.2&#x2012;102.6), respectively. Secondary analyses found no meaningful differences in PK parameters across injection sites. Serum-free C5 concentrations over time, treatment-emergent adverse event (TEAE) profiles, and antidrug antibody responses were similar between cohorts. Most TEAEs were mild; none led to study discontinuation. IMPLICATIONS: SC administration of gefurulimab by AI and PFS-SD was well tolerated with comparable exposure, meeting bioequivalence criteria.

Humans

Prothrombin complex concentrate (PCC) vs. non-PCC strategies for warfarin reversal in left ventricular assist device recipients: A systematic review and meta-analysis.

BACKGROUND: Left ventricular assist devices (LVADs) prolong survival in end-stage heart failure, and warfarin thromboprophylaxis is recommended to prevent device thrombosis and thromboembolic complications. When bleeding occurs or emergency surgery is required, rapid anticoagulation reversal is critical. Prothrombin complex concentrate (PCC) provides rapid reversal; however, its risk-benefit profile in LVAD recipients remains unclear. We conducted a systematic review and meta-analysis comparing PCC with non-PCC strategies for warfarin reversal in LVAD recipients. METHODS: MEDLINE, Embase, and Scopus were searched through June 2025 for studies of PCC versus non-PCC strategies for warfarin reversal in LVAD recipients. Two reviewers independently extracted data. Random-effects models were used to pool arm-level estimates and to pool head-to-head comparisons using mean differences or risk ratios (RRs). RESULTS: Eighteen studies involving 779 patients were included. Arm-level pooled estimates for PCC versus non-PCC comparators were 24.0% versus 15.8% for mortality, 16.5% versus 12.1% for thrombotic events, and 3.1 versus 5.7 for FFP units. Arm-level time to INR correction was longer with PCC overall (16.5 versus 13.6&#xa0;h), driven by one elective cohort, but faster within the ICH subgroup (6.0 versus 13.7&#xa0;h). In head-to-head comparisons, PCC achieved faster INR correction than non-PCC comparators (mean difference&#xa0;-&#xa0;7.6&#xa0;h; p&#xa0;=&#xa0;0.001) and required fewer FFP units (-2.6&#xa0;units; p&#xa0;=&#xa0;0.019), with no significant difference in all-cause mortality (RR 1.14; p&#xa0;=&#xa0;0.490) or thrombotic events (RR 1.43; p&#xa0;=&#xa0;0.176). CONCLUSIONS: In head-to-head studies, PCC was associated with faster INR correction and lower FFP requirements than non-PCC strategies, whereas mortality and thrombotic events did not differ significantly. Given the observational evidence, wide confidence intervals, and heterogeneity, equivalent safety cannot be established, and prospective studies are needed to define the relative safety and effectiveness of the two approaches. IMPLICATIONS FOR CLINICAL PRACTICE: PCC-based strategies may be considered for urgent warfarin reversal in LVAD recipients, particularly when rapid INR reduction or avoidance of large-volume plasma transfusion is clinically important. Treatment decisions should account for the indication, bleeding severity, and underlying thrombotic risk. TRIAL REGISTRATION: CRD42024573925.

Humans

Patient-reported outcome measures within European cohorts of severely injured patients: a systematic review and meta-analysis.

PURPOSE: Severe injury affects multiple health-related domains, yet comprehensive European data on patient-reported outcomes remain limited. This systematic review and meta-analysis evaluates patient-reported outcome measures (PROMs) use and outcomes in severely injured European cohorts. METHODS: A systematic search of four databases up to October 14, 2025, identified European studies from 2000 onward reporting PROMs in severely injured patients. Severe injury was defined as an Injury Severity Score&#x2009;&#x2265;&#x2009;16, Glasgow Coma Scale&#x2009;&#x2264;&#x2009;8, intensive care unit admission, spinal cord injury, traumatic amputations, or pelvic fractures. Two reviewers independently screened records, with disagreements resolved by a third reviewer. Meta-analysis was performed when &#x2265;&#x2009;3 studies reported comparable PROMs at similar follow-up timepoints. RESULTS: Of 2,479 studies, 119 were included. Most cohorts originated from the Netherlands (26%), Norway (18%), and Germany (16%). General severely injured cohorts were most frequently studied (61%), followed by traumatic brain injury (17%), and spinal cord injury (15%). In total, 94 PROMs were used across 277 follow-up timepoints. Health-related quality of life was assessed most frequently (63%), after that anxiety/depression (14%), post-traumatic stress (9%), and social functioning (6%). At one year follow-up, the pooled EuroQol-5D-3&#xa0;L index score was 0.70 (95% CI 0.62-0.77) and VAS score was 68 (95% CI 60-75), indicating persistent impairment compared to population norms. CONCLUSION: Severely injured patients show persistent impairments with incomplete restoration of pre-injury functioning. Despite increased PROMs use, heterogeneity in selection and outcome reporting limits comparability, underscoring the need for standardised PROM assessment to improve outcome evaluation after severe injury.

Humans

Sacral Neuromodulation in the Management of Refractory Pediatric Lower Urinary Tract Dysfunction.

INTRODUCTION: Sacral neuromodulation is currently used in the pediatric patient population for refractory lower urinary tract dysfunction (LUTD). Evidence, however, is currently limited for institutional experiences of long-term outcomes for sacral neuromodulation in the pediatric patient population. OBJECTIVE: The objective of this study is to perform a retrospective review of a large multi-institutional cohort of pediatric patients that underwent sacral neuromodulation (SNM) for refractory LUTD, focused on rates of symptom improvement, quality of life, and bowel-bladder dysfunction measures following device implantation. Secondary objectives included assessing device complication rates and device removals due to failure or successful resolution of symptoms. METHODS: We performed a retrospective cohort study of pediatric patients at three children's hospitals that underwent SNM device implantation for refractory LUTD. Patients 4-18 years of age who were diagnosed with refractory LUTD and managed at a participating institution with follow-up were included. Outcomes were evaluated at baseline and post-operatively after two-stage device implantation at initial follow-up and annually until device removal or final follow-up. RESULTS: From 2010 to 2022, a total of 205 children underwent SNM procedures at three pediatric hospital centers. 204 patients completed the two-stage procedure for permanent device implantation with a median follow-up of 3.4 years (1.3, 4.9). One hundred seventy-eight patients reported partial (25%) or complete (54%) device response/symptom improvement by final follow-up. Comparison of patient-reported validated questionnaires completed at baseline and by final follow-up visit revealed significant improvement in median Pediatric Quality of Life Inventory (PedsQL) (p&#x2009;=&#x2009;0.004) and Vancouver Nonneurogenic Lower Urinary Tract Dysfunction/Dysfunctional Elimination Syndrome bowel-bladder dysfunction (BBD) scores (p&#x2009;<&#x2009;0.001). Of those with any device complication (n&#x2009;=&#x2009;43;21%), 19 patients required device revision, and 20 required complete device removal. Separately, twenty-eight patients (13%) underwent device removal due to resolution of symptoms or treatment success at a median period of 5 years (4,7). CONCLUSION: SNM use demonstrated a majority of patients reporting at least partial subjective symptom improvement following device implantation across multiple institutions by final follow-up. SNM is a viable treatment option for refractory LUTD in the pediatric patient if willing to undergo an invasive procedure and in which thorough counseling of risks and benefits has occurred.

Humans

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Improving Patient Comfort of Vibratory Anesthetic Devices With a Dampener: A Pilot Study.

BACKGROUND: Vibratory anesthetic devices (VADs) reduce dermatologic injection pain, but their vibration can feel harsh at sensitive anatomical sites. Simple modifications improving patient comfort may enhance VAD adoption. OBJECTIVE: The authors evaluated whether dampening VAD vibration with a cotton buffer improves patient comfort and characterized tactile features influencing preferences. MATERIALS AND METHODS: In a single-site, participant-blinded pilot study (N = 53), adults received a dampened VAD (D-VAD) and standard VAD (S-VAD) at 5 sites-lateral nasal wall, submalar cheek, ear helix, lateral neck, and dorsal forearm-in randomized, contralateral application. Site-specific preference was analyzed with binomial and Cochran Q tests; demographic associations with univariate analyses. Word2vec and hierarchical clustering analyzed qualitative reasons behind patient preference. RESULTS: D-VAD was preferred at all sites across demographics-lateral nasal wall (88.7%), submalar cheek (84.9%), ear helix (88.7%), lateral neck (77.4%), and dorsal forearm (75.5%) (all p < .001), with strongest preference at face and head/neck (p = .018). Computational semantics analysis of qualitative responses identified 6 themes driving preference: Smoothness, Gentleness, Controlled, Low Frequency, Low Intensity, and Less Bothersome. CONCLUSION: Dampening VAD vibration with a cotton buffer enhances comfort across sensitive sites, with reduced harshness and smoother sensation underlying preference. This simple modification may improve patient experience, encouraging broader VAD adoption.

Humans

Artificial intelligence-supported double reading in European population breast cancer screening: A systematic review and meta-analysis of prospective programs.

BACKGROUND: Most European population mammography screening programs rely on double reading with arbitration, a model that delivers mortality benefit but is increasingly challenged by radiologist workload, variable specificity, and interval cancers. Artificial intelligence (AI) is being evaluated to support or optimize these established European screening pathways. PURPOSE: To synthesize prospective or program-embedded evaluations of AI conducted within European-style population screening programs and to estimate exploratory program-level absolute risk differences (RDs) per 1000 examinations for cancer detection rate (CDR) and recall. MATERIALS AND METHODS: We performed a prespecified, focused evidence synthesis of three large studies embedded within routine population screening programs operating under European-relevant workflows: MASAI (randomized AI-supported risk triage within a national program), ScreenTrustCAD (prospective paired-reader evaluation with AI as an independent reader in a double-reading framework), and PRAIM (nationwide decision-referral implementation). Outcomes were harmonized as AI-control RDs per 1000 examinations. Random-effects pooling used Hartung-Knapp-Sidik-Jonkman models. For the paired-reader design, sensitivity analyses applied a Kish effective sample-size approach across plausible within-examination correlations (&#x3c1;&#xa0;=&#xa0;0.3-0.8). Positive predictive value (PPV) and workflow/time outcomes were summarized descriptively. RESULTS: Across 597,419 examinations, the pooled CDR RD was +0.9 per 1000 (95% CI -0.0 to +1.8; I2&#xa0;&#x2248;&#xa0;12%), consistent with a modest directional increase with borderline statistical uncertainty. The pooled recall RD was -0.6 per 1000 (95% CI -3.1 to +2.1; I2&#xa0;&#x2248;&#xa0;41-43%), indicating no consistent recall increase across screening programs. Where reported, PPV was higher with AI-supported screening. Efficiency signals included 44.3% fewer total readings in MASAI and shorter reading times for AI-normal examinations in PRAIM; in PRAIM, a program-level safety-net mechanism recovered 204 cancers that would otherwise have been missed. CONCLUSION: In European population screening programs characterized by double reading and arbitration, prospective program-embedded evidence suggests that AI integration may yield a small absolute increase in cancer detection (&#x2248;1/1000) without a consistent increase in recall, alongside improved PPV and efficiency signals. These findings suggestAI primarily as a complementary reader within European screening workflows, with implementation requiring explicit quality assurance and monitoring of interval cancers and stage distribution.

Humans

Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha&#x2122; (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut&#x2122; (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut&#x2122; (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut&#x2122; (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade&#x2122; (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80&#x2009;g/min (95% confidence interval [CI] 6.26-9.34&#x2009;g/min) for Piranha, 4.70&#x2009;g/min (95% CI 3.61-5.79&#x2009;g/min) for VersaCut, 5.90&#x2009;g/min (95% CI 3.16-8.64&#x2009;g/min) for DrillCut, and 9.59&#x2009;g/min (95% CI 4.78-14.39&#x2009;g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75&#x2009;g/min; 95% CI -4.58 to -0.92&#x2009;g/min; P&#x2009;=&#x2009;0.003), with an even greater difference in prostates >70&#x2009;mL (-4.34&#x2009;g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Humans

Postoperative Curvature Loss in Three-Level Anterior Cervical Discectomy and Fusion With Zero-Profile Device.

PURPOSE: Cervical curvature loss is a frequent complication following 3-level anterior cervical discectomy and fusion (ACDF) using a Zero-Profile device. Consequently, the capacity of this device to maintain cervical sagittal alignment in 3-level ACDF remains highly controversial. This study aimed to identify potential predictors for postoperative curvature loss (PCL) and evaluate its impact on clinical outcomes. METHODS: A total of 113 patients who underwent ACDF for 3-level cervical degenerative disc disease (CDDD) between January 2021 and December 2023 were retrospectively reviewed. Demographic data, radiological parameters, and clinical outcomes were analyzed. Radiographic measures included cervical curvature, T1 slope, C2-7 sagittal vertical axis, and titanium plate and endplate (TPE) distance. Clinical outcomes were assessed using the Visual Analog Scale (VAS), Neck Disability Index (NDI), and Japanese Orthopaedic Association (JOA) scores. Statistical analyses were performed using paired and independent t-tests, as well as Pearson correlation coefficients. RESULTS: The average curvature loss was 6.82&#xb0; from 1&#x2009;week postoperatively to the final follow-up (p&#x2009;<&#x2009;0.001). However, the final curvature (11.65&#xb0;) was maintained, representing a 4.33&#xb0; improvement compared to preoperative values. Significant correlations were observed between PCL and preoperative curvature (r&#x2009;=&#x2009;-0.368, p&#x2009;=&#x2009;0.013), preoperative T1 slope (r&#x2009;=&#x2009;-0.546, p&#x2009;<&#x2009;0.001), &#x2206;T1 slope (r&#x2009;=&#x2009;0.443, p&#x2009;=&#x2009;0.002), and &#x2206;TPE distance (r&#x2009;=&#x2009;0.417, p&#x2009;=&#x2009;0.004). PCL did not correlate with Japanese Orthopaedic Association (JOA) scores or arm VAS scores at the final follow-up. Nevertheless, patients with a PCL&#x2009;&#x2265;&#x2009;6&#xb0; exhibited significantly higher neck VAS (p&#x2009;=&#x2009;0.028) and NDI scores (p&#x2009;=&#x2009;0.041). CONCLUSION: Although contiguous 3-level ACDF with a Zero-Profile device may result in PCL, it preserves an improved cervical lordosis compared to the preoperative baseline. Low preoperative curvature and a low preoperative T1 slope are potentially predictive factors for PCL. Postoperative changes in TPE distance and T1 slope are significantly associated with PCL, suggesting a potential biomechanical link that requires direct validation. Furthermore, PCL may lead to higher neck VAS and NDI scores. Consequently, the Zero-Profile device may require careful consideration in 3-level CDDD patients presenting with low preoperative curvature and a low T1 slope. Importantly, the 6&#xb0; PCL threshold identified is preliminary and requires prospective validation before clinical application.

Humans

Tele-Oncology in the Post-Pandemic Era: Clinical Integration, Access Disparities and Medico-Legal Accountability.

PURPOSE OF THE REVIEW: Tele-health has evolved from a marginal tool confined to rural populations and selected follow-up programs into a structurally integrated component of modern cancer care. Prior to COVID-19, its adoption was constrained by regulatory fragmentation, non-uniform reimbursement, and licensure barriers. This narrative review evaluates the evolutionary integration of tele-health in oncology post-COVID-19, examines digital disparities across patient populations, and addresses the medico-legal implications of this integration, with the objective of providing a comprehensive and clinically actionable framework for the governance of virtual oncology care. RECENT FINDINGS: The pandemic acted as a global catalyst, driving telehealth to over 50% of oncology outpatient encounters in some settings, before stabilising post-pandemic at approximately 10-20% of consultations within hybrid care models. Evidence supports meaningful clinical benefits - improved access to specialist services, reduced travel burden, and sustained continuity of care - with outcomes comparable to in-person care in postoperative follow-up, symptom monitoring, and survivorship. However, persistent disparities in device availability, connectivity, and digital literacy disproportionately affect older, rural, and socioeconomically disadvantaged patients, raising the risk that geographic inequalities are replaced by technological ones. From a medico-legal standpoint, the remote modality does not modify the applicable standard of care, yet restricted physical examination and reliance on patient-reported data introduce risks of diagnostic delay and incomplete clinical assessment, with direct implications for professional liability, data protection under HIPAA and GDPR, cross-border licensure, and multi-party accountability across physicians, institutions, and technology providers. Tele-oncology has become a permanent structural feature of modern cancer care, offering demonstrable benefits in access, continuity, and patient satisfaction. Yet its integration has been uneven, its governance remains fragmented, and its medico-legal landscape is still evolving. Realising the full potential of virtual oncology care - equitably and safely - requires coherent regulatory frameworks, sustained investment in digital infrastructure, and explicit attention to the populations at greatest risk of being left behind.

Humans

Community-driven advances in computational mass spectrometry: The perspective of EuBIC-MS members.

Advances in data acquisition, artificial intelligence, and integrative bioinformatics are driving the rapid evolution of computational mass spectrometry, and in turn, transforming modern proteomics, metabolomics, and lipidomics. These developments have greatly increased the scale and complexity of mass spectrometry data, underscoring the importance of evolving accurate, transparent, efficient and reproducible data processing workflows. Addressing these challenges requires collaborative innovation that brings together expertise in software engineering, statistics, and biology. The European Bioinformatics Community for Mass Spectrometry (EuBIC-MS), an initiative of the European Proteomics Association (EuPA), fosters a culture of open, community-driven development through its biennial Developers Meetings and Winter Schools. This commentary summarizes the scientific background and outcomes of the EuBIC-MS Developers Meeting 2025, which took place in Novacella, Italy. Three keynote presentations highlighted major frontiers in the field: deep proteome and phosphoproteome profiling, text mining for protein-protein interaction extraction, and scalable proteomics for AI-driven drug discovery. Seven community-selected hackathons addressed emerging challenges such as single-cell proteomics data analysis, FAIR metadata extraction, deep learning frameworks, R-Python interoperability, and DIA validation. Together, these efforts demonstrate the potential for scientific and technical innovation to arise from open collaboration, and highlight how community-driven initiatives can accelerate progress in computational mass spectrometry. SIGNIFICANCE: Modern proteomics increasingly depends on computational advances to translate complex, high-dimensional data into biological knowledge. The EuBIC-MS Developers Meeting 2025 exemplifies how community-driven collaboration can directly accelerate this process by bringing together experts from bioinformatics, statistics, and experimental proteomics to co-develop open, interoperable, and reproducible analytical tools. By fostering shared software frameworks, transparent benchmarking, and collaborative problem solving, the EuBIC-MS community helps ensure that technological innovation translates into reliable biological insights. This collaborative model strengthens the foundation for quantitative, system-level understanding of proteomes and establishes a sustainable path for integrating artificial intelligence and next-generation data acquisition into routine biological discovery. This commentary shows some current highlights in the field of computational mass spectrometry and community-based approaches undertaken during the most recent Developers Meeting to solve these challenges. The approaches discussed and initiated during the meeting - ranging from deep proteome profiling and phosphosite mapping to text mining, single-cell data analysis, and FAIR metadata extraction - address key bottlenecks that currently limit the biological interpretability and comparability of proteomics data.

Mass Spectrometry