Search PubMedSearch

SEARCH · Search PubMed

Results for “high-risk medical devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,629 records · Page 2Linked to original sources

Oxygen-controlled gamma-irradiation and annealing enable terminal processing of collagen-based biomaterials.

Gamma irradiation is a widely adopted method for terminal sterilization of medical devices; however, its application to collagen-based extracellular matrix (ECM) materials remains limited due to radiation-induced degradation of structural integrity and mechanical performance. Here, we present an engineered terminal-processing strategy that combines oxygen controlled gamma irradiation (25-30 kGy) with post-irradiation dry-heat annealing to preserve ECM functionality while achieving effective sterilization. By modulating oxygen availability during irradiation, this approach alters radical reaction pathways, suppresses oxygen-mediated oxidative degradation, and generates a metastable radical-containing intermediate, which is subsequently converted into a structurally stabilized collagen network through thermal annealing. As a result, the treated matrices preserved ECM integrity and recovered clinically relevant mechanical properties. Furthermore, the process achieved cumulative viral reductions exceeding 6 log10 across a representative panel including enveloped and non-enveloped DNA and RNA viruses, demonstrating compatibility with sterility assurance and viral safety requirements for biologically derived medical devices. Notably, preliminary observations indicate that mechanical integrity can be partially preserved even at elevated irradiation doses up to 50 kGy, suggesting potential applicability to sterilization validation frameworks requiring higher assurance levels. Overall, this work establishes a mechanistically grounded terminal-processing paradigm that enables control of radical fate, decouples sterilization efficacy from material degradation, and integrates sterilization, viral safety, and functional preservation into a unified and scalable framework for collagen-based biomaterials. This concept repositions gamma-irradiation from a purely degradative process to a controllable tool for tuning collagen structure and performance.

Gamma Rays

Tele-Oncology in the Post-Pandemic Era: Clinical Integration, Access Disparities and Medico-Legal Accountability.

PURPOSE OF THE REVIEW: Tele-health has evolved from a marginal tool confined to rural populations and selected follow-up programs into a structurally integrated component of modern cancer care. Prior to COVID-19, its adoption was constrained by regulatory fragmentation, non-uniform reimbursement, and licensure barriers. This narrative review evaluates the evolutionary integration of tele-health in oncology post-COVID-19, examines digital disparities across patient populations, and addresses the medico-legal implications of this integration, with the objective of providing a comprehensive and clinically actionable framework for the governance of virtual oncology care. RECENT FINDINGS: The pandemic acted as a global catalyst, driving telehealth to over 50% of oncology outpatient encounters in some settings, before stabilising post-pandemic at approximately 10-20% of consultations within hybrid care models. Evidence supports meaningful clinical benefits - improved access to specialist services, reduced travel burden, and sustained continuity of care - with outcomes comparable to in-person care in postoperative follow-up, symptom monitoring, and survivorship. However, persistent disparities in device availability, connectivity, and digital literacy disproportionately affect older, rural, and socioeconomically disadvantaged patients, raising the risk that geographic inequalities are replaced by technological ones. From a medico-legal standpoint, the remote modality does not modify the applicable standard of care, yet restricted physical examination and reliance on patient-reported data introduce risks of diagnostic delay and incomplete clinical assessment, with direct implications for professional liability, data protection under HIPAA and GDPR, cross-border licensure, and multi-party accountability across physicians, institutions, and technology providers. Tele-oncology has become a permanent structural feature of modern cancer care, offering demonstrable benefits in access, continuity, and patient satisfaction. Yet its integration has been uneven, its governance remains fragmented, and its medico-legal landscape is still evolving. Realising the full potential of virtual oncology care - equitably and safely - requires coherent regulatory frameworks, sustained investment in digital infrastructure, and explicit attention to the populations at greatest risk of being left behind.

Humans

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Use of wearable technologies for physical activity promotion in older adults: A systematic review.

This systematic review, conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251055299), examined the use of wearable technologies for promoting physical activity (PA) in adults aged 60 years and older. Searches across five databases (PubMed, Scopus, Web of Science, CINAHL, Cochrane) identified 2438 records, of which only six randomized controlled trials published between 2021 and 2025 met inclusion criteria, with sample sizes ranging from 36 to 551 participants and mean ages between 65 and 79 years. Given the small number of included studies, findings should be interpreted as preliminary. The studies ranged from the standalone use of commercial trackers (Fitbit, Polar, ActiGraph) to multicomponent interventions combining wearables with physiotherapist feedback, telephone counseling, web-based platforms, or interactive cognitive-motor training. Wearables used alone, as in the REACT trial, produced small or non-significant PA effects. In contrast, interventions integrating devices with personalized feedback, professional support, or digital platforms, such as PROMOTE and TASMANIA, were associated with more consistent improvements in PA, physical function, and cognitive outcomes. Multicomponent programs, such as PEER and ICMT, reported broader benefits, including cognition, balance, and reductions in sedentary behavior, though these findings derive from individual trials and require replication. Risk of bias, assessed with the Cochrane Risk of Bias tool version 2 (RoB 2.0), was rated as "some concerns" for five studies and low for only one, mainly due to gaps in randomization reporting, missing data, and lack of preregistration. Tentatively, and based on a very limited evidence base, wearables may have greater impact when embedded within broader behavioral systems, incorporating feedback, coaching, or interactive components, rather than when used in isolation as passive monitoring tools. Adherence and psychosocial outcomes appeared related to comfort and perceived usefulness among older adults, though larger and more robust trials are needed to confirm these patterns.

Humans

Sacral Neuromodulation in the Management of Refractory Pediatric Lower Urinary Tract Dysfunction.

INTRODUCTION: Sacral neuromodulation is currently used in the pediatric patient population for refractory lower urinary tract dysfunction (LUTD). Evidence, however, is currently limited for institutional experiences of long-term outcomes for sacral neuromodulation in the pediatric patient population. OBJECTIVE: The objective of this study is to perform a retrospective review of a large multi-institutional cohort of pediatric patients that underwent sacral neuromodulation (SNM) for refractory LUTD, focused on rates of symptom improvement, quality of life, and bowel-bladder dysfunction measures following device implantation. Secondary objectives included assessing device complication rates and device removals due to failure or successful resolution of symptoms. METHODS: We performed a retrospective cohort study of pediatric patients at three children's hospitals that underwent SNM device implantation for refractory LUTD. Patients 4-18 years of age who were diagnosed with refractory LUTD and managed at a participating institution with follow-up were included. Outcomes were evaluated at baseline and post-operatively after two-stage device implantation at initial follow-up and annually until device removal or final follow-up. RESULTS: From 2010 to 2022, a total of 205 children underwent SNM procedures at three pediatric hospital centers. 204 patients completed the two-stage procedure for permanent device implantation with a median follow-up of 3.4 years (1.3, 4.9). One hundred seventy-eight patients reported partial (25%) or complete (54%) device response/symptom improvement by final follow-up. Comparison of patient-reported validated questionnaires completed at baseline and by final follow-up visit revealed significant improvement in median Pediatric Quality of Life Inventory (PedsQL) (p&#x2009;=&#x2009;0.004) and Vancouver Nonneurogenic Lower Urinary Tract Dysfunction/Dysfunctional Elimination Syndrome bowel-bladder dysfunction (BBD) scores (p&#x2009;<&#x2009;0.001). Of those with any device complication (n&#x2009;=&#x2009;43;21%), 19 patients required device revision, and 20 required complete device removal. Separately, twenty-eight patients (13%) underwent device removal due to resolution of symptoms or treatment success at a median period of 5 years (4,7). CONCLUSION: SNM use demonstrated a majority of patients reporting at least partial subjective symptom improvement following device implantation across multiple institutions by final follow-up. SNM is a viable treatment option for refractory LUTD in the pediatric patient if willing to undergo an invasive procedure and in which thorough counseling of risks and benefits has occurred.

Humans

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16&#x2009;weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Effect of Music on Pain, Anxiety, and Satisfaction During Intrauterine Device Application: A Randomized Clinical Trial.

This randomized controlled trial aimed to determine the effect of music played during intrauterine device (IUD) insertion on perceived pain, state anxiety, and satisfaction levels. The study was conducted with 70 women who applied to a maternal and child health and family planning center and were randomly assigned to the intervention and control groups using simple randomization. Data were collected using a Demographic Information Form, the State-Trait Anxiety Inventory (STAI-I), and the Visual Analog Scale (VAS), as well as Bluetooth speakers and the musical piece Evgeny Grinko-Valse. Participants in the intervention group listened to music before and during the IUD insertion procedure, whereas the control group received routine care only. Data were analyzed using SPSS version 26 with appropriate descriptive and inferential statistical methods. Women in the music group had significantly lower perceived pain (p&#x2009;<&#x2009;0.001) and state anxiety levels during the procedure (p&#x2009;=&#x2009;0.022), and significantly higher satisfaction levels compared with the control group (p&#x2009;<&#x2009;0.001). In addition, post-procedure state anxiety levels were positively correlated with pain intensity experienced during and after the procedure (r&#x2009;=&#x2009;0.542 and r&#x2009;=&#x2009;0.496, respectively; p&#x2009;<&#x2009;0.001), and negatively correlated with procedural satisfaction (r&#x2009;=&#x2009;-0.652; p&#x2009;<&#x2009;0.001). These findings suggest that listening to music during IUD insertion may help reduce pain and anxiety while potentially enhancing patient satisfaction. Trial Registration: NCT06215183.

Humans

Wearable Sleep Monitoring in Pediatric Acute Lymphoblastic Leukemia: Associations With Subjective Sleep Ratings and Neurocognitive Functioning.

BACKGROUND: Sleep disturbances are associated with increased fatigue, reduced quality of life, and neurocognitive dysfunction and have emerged as a common complication among pediatric cancer survivors. Sleep disturbances are particularly concerning given their potential to exacerbate existing neurocognitive impacts of cancer treatments. This pilot study examined the feasibility and acceptability of a home-wearable EEG-based sleep device (Sleep ProfilerTM) for acute lymphoblastic leukemia (ALL) survivors as well as associations between specific sleep parameters and neurocognitive functioning. PROCEDURE: Children (ages 8-12; M = 10 years, SD = 1.6; N = 23) >6 months post-treatment for ALL were enrolled at clinical visits and wore the Sleep ProfilerTM for two consecutive nights at home, followed by neurocognitive testing of attention, inhibitory control, working memory, and processing speed. Parents completed subjective measures of child sleep, anxiety, depression, and acceptability. Feasibility reflected the percentage of children wearing the device at least one night and the percentage of nights with good EEG quality data. RESULTS: All participants wore the device both nights, with 84% meeting the threshold for good quality measurement. Few children met recommended quantity and quality sleep thresholds based on objective measurement, including 5 patients with elevated snoring levels; 43.5% of subjective ratings fell above the threshold for sleep disturbance. Greater sleep latency was associated with worse inhibitory control (r = -0.42, p = 0.046), and total sleep time was positively associated with inhibitory control and attention. CONCLUSIONS: Findings confirm the feasibility and acceptability of home EEG sleep monitoring in school-age survivors, and associations of sleep latency and snoring with reduced neurocognitive functioning may offer modifiable risk factors for aspects of neuropsychological dysfunction common in pediatric survivorship. CLINICAL TRIAL REGISTRATION: At the time this study was conducted, we were not required to register the study on ClinicalTrials.gov. It was a single-institution feasibility study without intervention, which was not considered a clinical trial.

Humans

Teaching Acute Coronary Syndrome High-Risk ECG Interpretation and Clinical Decision-Making Through FOAMed Videos and Podcast Versus Print-Based Materials Among Emergency Care Providers: Randomized Controlled Mixed Methods Trial.

BACKGROUND: Accurate interpretation of high-risk acute coronary syndrome (ACS) electrocardiograms (ECGs) is essential for early diagnosis and timely reperfusion, yet substantial deficits persist across health care professions. Digital self-learning formats such as FOAMed (Free Open Access Medical Education) are widely used, but their effectiveness has rarely been evaluated for complex, high-risk ACS ECG patterns. Existing ECG education studies often focus on students or single professional groups and established ST-segment elevation myocardial infarction (STEMI) criteria, leaving newer guideline-recognized STEMI equivalents, selected emerging occlusion myocardial infarction (OMI)-related patterns, and interprofessional emergency care underrepresented. OBJECTIVE: This study aimed to compare the effectiveness of FOAMed podcast and videos versus traditional print-based materials for teaching high-risk ACS ECG patterns and related clinical decision-making in emergency providers. METHODS: We conducted a prospective, interprofessional, controlled mixed methods trial across 5 training sites in Germany. Paramedics, prehospital emergency physicians, and emergency department clinicians received either a FOAMed multimedia module or print-based materials through concealed allocation; deviations from the intended 1:1 ratio resulted from participant no-shows. The intervention consisted of a 30-minute supervised self-learning session. In total, 103 participants were allocated to FOAMed (n=45) or print-based materials (n=58). Two coprimary outcomes were assessed: ECG interpretation accuracy and text-based ACS clinical decision-making. Secondary outcomes included subjective confidence, learning experience, and exploratory qualitative free-text responses. Outcome assessment was automated and blinded; mixed ANOVA was the primary analysis. The study was not prospectively registered because it assessed educational outcomes in health care professionals rather than patient health outcomes. RESULTS: All 103 participants completed the study. Both groups improved, with greater gains in the FOAMed group: ECG interpretation increased from 55% to 65.5% and text-based ACS clinical decision-making from 45% to 68%, versus 57% to 60% and from 47% to 63%, respectively, in the print-based group. Effect sizes were &#x3b7;&#xb2;=0.055 for ECG interpretation and &#x3b7;&#xb2;=0.044 for clinical decision-making. Exploratory subgroup analyses provided no evidence of differential effects across age, gender, or professional background and were likely underpowered. Qualitative responses (46 and 37 entries) provided contextual insights into perceived clarity, engagement, and practical relevance supporting the quantitative findings. CONCLUSIONS: This study is innovative in directly comparing a curated FOAMed multimedia module with selected print-based materials in an interprofessional emergency care population. It differs from existing research by focusing on subtle, emerging ischemic patterns and evaluating realistic, time-limited self-learning formats. The findings provide evidence that curated FOAMed resources can produce greater short-term improvements in ECG interpretation and text-based ACS clinical decision-making than traditional print-based materials in this setting. Although implications for clinical performance remain hypothetical, concise, high-quality digital modules may represent a practical supplement to structured continuing education in emergency care.

Humans

Changes in sexual behavior among women in studies evaluating the dapivirine vaginal ring for HIV prevention.

BACKGROUND: Access to novel HIV prevention technologies often raise concerns of risk compensation. This analysis examined changes in the sexual behaviors of MTN 020/ASPIRE participants, a placebo controlled randomized control trial, who subsequently enrolled in MTN-025/HOPE, an open-label extension using the dapivirine vaginal ring. METHODS: Both studies enrolled healthy, sexually active, HIV-negative women from Malawi, South Africa, Uganda and Zimbabwe. Longitudinal data on participants' sexual behaviors, specifically sex with a nonprimary partner (past 3&#xa0;months), and use of male or female condoms at the last vaginal sex act were compared between ASPIRE and HOPE. Conditional and mixed ordinal logistic regression models evaluated associations between study and sexual behaviors at enrollment,&#xa0;and quarterly over the first 12&#xa0;months. RESULTS: Of the 2629 individuals enrolled in ASPIRE, 1456 (55%) participated in HOPE. At enrollment, the proportion of participants who reported sex with a nonprimary partner and condom use at last vaginal sex act did not differ by study. Across all quarterly follow-up visits, sex with a nonprimary partner was more common in HOPE (13.9-18.7%) than ASPIRE (10.7-12.6%); adjusted OR&#xa0;1.47, 95% CI 1.24-1.75, P&#xa0;<&#xa0;0.001. There was no difference in condom use at the last vaginal act across all quarterly follow-up visits between ASPIRE (36.5-42.7%) and HOPE (43.6-46.7%); adjusted OR&#xa0;1.05, 95% CI 0.94-1.18. CONCLUSION: More women reported sex with nonprimary partners in HOPE, with little change in condom use over time between the two studies. Understanding behavior changes during PrEP use allows for tailored, holistic reproductive health programming.

Humans

Phase 1 Study Evaluating Gefurulimab Pharmacokinetics and Safety Following Delivery Via Autoinjector or Prefilled Syringe With Needle Safety Device in Healthy Adults.

PURPOSE: Gefurulimab, a novel dual-binding nanobody targeting complement component 5 (C5), is in clinical development for anti-acetylcholine receptor antibody-positive generalized myasthenia gravis. Gefurulimab has a low molecular weight, enabling subcutaneous (SC) self-administration by autoinjector (AI) or prefilled syringe with needle safety device (PFS-SD). We compared gefurulimab pharmacokinetic (PK) exposure and safety in healthy adults following a single SC dose administered by AI versus PFS-SD. METHODS: In this phase 1, open-label, randomized, parallel-group study (NCT06208488), healthy participants aged 18 to 65 years were stratified by weight and randomized equally to 1 of 6 combination groups of device and injection site (abdomen/thigh/upper arm). Participants received a single SC dose of gefurulimab on day 1 and were assessed throughout the 92-day evaluation period. Primary endpoints were PK parameters for each device: maximum observed concentration (Cmax) and area under the serum concentration-time curve (AUCinf, AUClast). PK across injection sites, pharmacodynamics, safety, immunogenicity, and device performance were also assessed. FINDINGS: Overall, 175 participants were randomized: AI (n = 87), PFS-SD (n = 88). Geometric least squares mean ratios (90% CI) comparing AI/PFS-SD for Cmax, AUCinf, and AUClast were 97.6% (94.5-100.8), 99.6% (96.1-103.3), and 98.8% (95.2&#x2012;102.6), respectively. Secondary analyses found no meaningful differences in PK parameters across injection sites. Serum-free C5 concentrations over time, treatment-emergent adverse event (TEAE) profiles, and antidrug antibody responses were similar between cohorts. Most TEAEs were mild; none led to study discontinuation. IMPLICATIONS: SC administration of gefurulimab by AI and PFS-SD was well tolerated with comparable exposure, meeting bioequivalence criteria.

Humans

Treatment of OSA using mandibular advancement versus CPAP in improving cardiovascular health.

BACKGROUND: Obstructive sleep apnea is a significant risk factor for hypertension. We assessed the relative effectiveness of mandibular advancement device (MAD) versus continuous positive airway pressure (CPAP) in reducing 24 h ambulatory blood pressure (BP) and other health-related outcomes over 12 months. METHODS: In a randomized, non-inferiority trial, 321 participants with hypertension and increased cardiovascular risk were recruited for polysomnography. Of these, 220 with moderate-to-severe OSA (apnea-hypopnea index (AHI) &#x2265;15 events/hour) were randomized to MAD or CPAP (1:1). We report the final outcomes at the 12-month follow-up. RESULTS: A total of 180 participants (MAD: 89; CPAP: 91) completed the 12-month follow-up. Median usage for MAD and CPAP was 5.5 and 4.9 h per night, respectively. Compared to baseline, the 24 h mean arterial BP at 12 months decreased by 2.3 mmHg (P = 0.200) in the MAD group and by 1.0 mmHg (P = 0.999) in the CPAP group. The difference between-groups was -0.6 mmHg (95% confidence interval: -2.53 to 1.39, non-inferiority P < 0.019). The MAD group demonstrated a larger reduction in asleep BP compared to the CPAP group. The prevalence of excessive daytime sleepiness in the MAD group decreased from 30.3% at baseline to 10.1% at 12-month follow-up (P = 0.001), and from 38.5% to 7.7% in the CPAP group (P < 0.001). The between-group difference was 10.6% (P = 0.097). No significant within-group or between-group differences were observed in the prevalence of arrhythmias and plasma levels of cardiac biomarkers. CONCLUSION: At 12-month, MAD is non-inferior to CPAP for reducing 24 h mean arterial BP in participants with hypertension and increased cardiovascular risk. TRIAL REGISTRATION: NCT04119999.

Humans

Improving Patient Comfort of Vibratory Anesthetic Devices With a Dampener: A Pilot Study.

BACKGROUND: Vibratory anesthetic devices (VADs) reduce dermatologic injection pain, but their vibration can feel harsh at sensitive anatomical sites. Simple modifications improving patient comfort may enhance VAD adoption. OBJECTIVE: The authors evaluated whether dampening VAD vibration with a cotton buffer improves patient comfort and characterized tactile features influencing preferences. MATERIALS AND METHODS: In a single-site, participant-blinded pilot study (N = 53), adults received a dampened VAD (D-VAD) and standard VAD (S-VAD) at 5 sites-lateral nasal wall, submalar cheek, ear helix, lateral neck, and dorsal forearm-in randomized, contralateral application. Site-specific preference was analyzed with binomial and Cochran Q tests; demographic associations with univariate analyses. Word2vec and hierarchical clustering analyzed qualitative reasons behind patient preference. RESULTS: D-VAD was preferred at all sites across demographics-lateral nasal wall (88.7%), submalar cheek (84.9%), ear helix (88.7%), lateral neck (77.4%), and dorsal forearm (75.5%) (all p < .001), with strongest preference at face and head/neck (p = .018). Computational semantics analysis of qualitative responses identified 6 themes driving preference: Smoothness, Gentleness, Controlled, Low Frequency, Low Intensity, and Less Bothersome. CONCLUSION: Dampening VAD vibration with a cotton buffer enhances comfort across sensitive sites, with reduced harshness and smoother sensation underlying preference. This simple modification may improve patient experience, encouraging broader VAD adoption.

Humans

Clinical predictors of severe and fatal respiratory syncytial virus infection in adults and the elderly: A retrospective cohort study.

BACKGROUND: Respiratory syncytial virus (RSV) is increasingly recognized as a cause of severe respiratory illness in adults, especially the elderly and those with comorbidities. However, data on outcomes and risk factors for severe disease in this population remain limited. METHODS: We retrospectively analyzed 123 adult patients diagnosed with RSV infection at a tertiary center in Taiwan from 2015 to 2023. Clinical characteristics, laboratory data, detection of other pathogens, clinical course and outcome were reviewed. Multivariable logistic regression identified risk factors for severe RSV infection, including ICU admission and 30-day mortality. RESULTS: The mean age was 55.7 years; 50% were aged &#x2265;60 years and 13% were &#x2265;75 years. ICU admission occurred in 17%, with significant associations to viral coinfection and elevated C-reactive protein (CRP). Thirty-day mortality was 13%, and overall in-hospital mortality was 18%, all among patients with comorbidities. Independent predictors of 30-day mortality included late elderly (aOR 24.2, p&#x202f;=&#x202f;0.03), high CRP > 11.5&#x202f;mg/dL (aOR 16.4, p&#x202f;=&#x202f;0.005) and thrombocytopenia < 34,103/&#x3bc;L (aOR 11.4, p&#x202f;=&#x202f;0.01). CONCLUSION: Advanced age (&#x2265;75 years), high CRP, and severe thrombocytopenia are key predictors of mortality in adults RSV patients. These findings highlight the need for targeted prevention strategies, including vaccination, in high-risk populations.

Co-infection

Postoperative Curvature Loss in Three-Level Anterior Cervical Discectomy and Fusion With Zero-Profile Device.

PURPOSE: Cervical curvature loss is a frequent complication following 3-level anterior cervical discectomy and fusion (ACDF) using a Zero-Profile device. Consequently, the capacity of this device to maintain cervical sagittal alignment in 3-level ACDF remains highly controversial. This study aimed to identify potential predictors for postoperative curvature loss (PCL) and evaluate its impact on clinical outcomes. METHODS: A total of 113 patients who underwent ACDF for 3-level cervical degenerative disc disease (CDDD) between January 2021 and December 2023 were retrospectively reviewed. Demographic data, radiological parameters, and clinical outcomes were analyzed. Radiographic measures included cervical curvature, T1 slope, C2-7 sagittal vertical axis, and titanium plate and endplate (TPE) distance. Clinical outcomes were assessed using the Visual Analog Scale (VAS), Neck Disability Index (NDI), and Japanese Orthopaedic Association (JOA) scores. Statistical analyses were performed using paired and independent t-tests, as well as Pearson correlation coefficients. RESULTS: The average curvature loss was 6.82&#xb0; from 1&#x2009;week postoperatively to the final follow-up (p&#x2009;<&#x2009;0.001). However, the final curvature (11.65&#xb0;) was maintained, representing a 4.33&#xb0; improvement compared to preoperative values. Significant correlations were observed between PCL and preoperative curvature (r&#x2009;=&#x2009;-0.368, p&#x2009;=&#x2009;0.013), preoperative T1 slope (r&#x2009;=&#x2009;-0.546, p&#x2009;<&#x2009;0.001), &#x2206;T1 slope (r&#x2009;=&#x2009;0.443, p&#x2009;=&#x2009;0.002), and &#x2206;TPE distance (r&#x2009;=&#x2009;0.417, p&#x2009;=&#x2009;0.004). PCL did not correlate with Japanese Orthopaedic Association (JOA) scores or arm VAS scores at the final follow-up. Nevertheless, patients with a PCL&#x2009;&#x2265;&#x2009;6&#xb0; exhibited significantly higher neck VAS (p&#x2009;=&#x2009;0.028) and NDI scores (p&#x2009;=&#x2009;0.041). CONCLUSION: Although contiguous 3-level ACDF with a Zero-Profile device may result in PCL, it preserves an improved cervical lordosis compared to the preoperative baseline. Low preoperative curvature and a low preoperative T1 slope are potentially predictive factors for PCL. Postoperative changes in TPE distance and T1 slope are significantly associated with PCL, suggesting a potential biomechanical link that requires direct validation. Furthermore, PCL may lead to higher neck VAS and NDI scores. Consequently, the Zero-Profile device may require careful consideration in 3-level CDDD patients presenting with low preoperative curvature and a low T1 slope. Importantly, the 6&#xb0; PCL threshold identified is preliminary and requires prospective validation before clinical application.

Humans

The effect of dietetic counseling combined with digital tools intervention on hemodynamic markers in Greek adults: The GATEKEEPER Study.

BACKGROUND AND AIM: Hypertension is a leading cardiovascular risk factor with substantial global impact on morbidity, mortality, and healthcare costs. While lifestyle interventions remain central to management, mHealth technologies offer promising adjunctive support, though their clinical effectiveness remains uncertain. This study evaluated whether combining dietetic counseling with digital tools improves hemodynamic markers in adults aged &#x2265;55 years with increased cardiometabolic risk. METHODS AND RESULTS: This 3-month RCT (NCT05031299) included 954 adults with at least one metabolic syndrome risk factor, allocated 1:1:1 to Standard Care (dietetic counseling), Platform (counseling plus web-based platform), or Platform&#xa0;+&#xa0;Devices (counseling plus platform plus wearables). Outcomes included anthropometrics, lifestyle characteristics, blood pressure, pulse pressure, and estimated pulse wave velocity, analyzed using linear mixed-effects models adjusted for age and sex. All groups improved over 3 months. Waist circumference decreased by -6.29, -4.92, and -4.69&#xa0;cm across Standard Care, Platform, and Platform&#xa0;+&#xa0;Devices groups respectively, and systolic blood pressure declined by -4.84 to -7.15&#xa0;mmHg across groups. The Platform&#xa0;+&#xa0;Devices group showed greater increases in physical activity (94.62 MET-min/week; 95% CI 66.49 to 122.76) and greater reductions in pulse pressure (-3.90&#xa0;mmHg; -6.58 to -1.22) versus Standard Care. Weight loss was associated with lower odds of hypertension (OR 0.4; 95% CI 0.2-0.7), greater likelihood of hypertension reversal (OR 3.6; 1.2-10.3), and higher probability of achieving normal pulse pressure (OR 1.8; 1.1-3.1). CONCLUSIONS: Dietary lifestyle intervention improved cardiometabolic outcomes, with limited added benefit from digital tools. Weight loss was the primary driver of hemodynamic improvement.

Aged

Effect of urinary catheter securement band on meatal pressure injury in male intensive care patients: A randomized controlled trial.

OBJECTIVES: To investigate the effectiveness of a urinary catheter securement band in preventing meatal pressure injury (meatal-PI) in male ICU patients, and to identify associated risk factors and the timing of injury development. METHODS: A total of 248 adult male ICU patients were randomly allocated to an intervention group (n&#xa0;=&#xa0;124) or a control group (n&#xa0;=&#xa0;124) between December 2024 and April 2025. The intervention group received a catheter securement band in addition to standard care, while the control group received standard care alone. Meatal-PI was evaluated daily using a structured monitoring form and a validated staging system. RESULTS: The incidence of meatal-PI was significantly lower in the intervention group (6.5%) compared with the control group (16.1%) (p&#xa0;=&#xa0;0.016). Multivariate analysis identified catheter securement, use of silicone catheters, higher Braden Scale scores, and shorter ICU length of stay as independent protective factors, while advanced age was associated with increased risk. Additional factors significantly associated with meatal-PI included comorbidities, higher device burden, latex catheter use, dry skin, lower Glasgow Coma Scale and Braden scores, sedation, and perineal oedema (p&#xa0;<&#xa0;0.001). CONCLUSIONS: The use of a catheter securement band significantly reduces the incidence of meatal-PI in male ICU patients. Incorporating catheter securement devices into routine nursing care, prioritising silicone catheter use, and performing regular meatal assessments may enhance patient safety by reducing the risk of device-related pressure injuries. Further research comparing different catheter securement methods across diverse patient populations is warranted. IMPLICATIONS FOR CLINICAL PRACTICE: The use of catheter securement bands may reduce the incidence of meatal-PI in male ICU patients. Incorporating standardized catheter stabilization strategies into routine intensive care nursing practice may enhance patient safety and support pressure injury prevention efforts.

Humans