Search PubMedSearch

SEARCH · Search PubMed

Results for “diagnostic test accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

772 records · Page 2Linked to original sources

A child and young person focused systematic review of scrotal ultrasound with Mitigants to identify missed torsion.

BACKGROUND: Diagnostic accuracy of ultrasound for adults is stated as excellent. Paediatric and adult acute scrotal diseases are different. Findings in adults may not apply in children. The authors have seen overconfidence and interpretation with adult disease in mind in children with scrotal pain and have seen testicular loss as a result. OBJECTIVES: To interrogate the literature methodologically to report diagnostic accuracy of ultrasound (US) for the acute scrotum specifically in CYP with a follow-up methodology which allows identification of missed torsion. STUDY DESIGN: We performed systematic review and meta-analysis of studies reporting true diagnostic accuracy of ultrasound for testicular torsion (TT). PubMed, MEDLINE, Scopus, and Web of Science databases were searched from platform start until September 2023 using MeSH terms with protocol as detailed on PROSPERO. Multiple author search was undertaken. Two authors extracted data for included studies. Study quality was reported through QUADAS-2 methodology. Surgical findings or 12 months follow up in non-operative cases would be the gold standard to identify late atrophy due to missed torsion. Studies with methodology to identify missed torsion outwith the initial consult were included for meta-analysis. RESULTS: A total of 6790 cases were reported from the 38 papers identified. Studies were often flawed with poor definition of outcomes and short follow-up duration. Meta-analysis of the 10 high-quality studies revealed pooled sensitivity and specificity of 0.93 and 0.99. Doppler US by trained individuals demonstrated excellent diagnostic accuracy. Nonetheless, on extrapolation of the data, especially where flow was preserved, 5.6% of torsions were missed. DISCUSSION/CONCLUSION: Our review confirms a high diagnostic accuracy of US for TT in CYP. However, a 5.6% missed torsion rate was found if flow alone was considered diagnostic. The authors suggest US should be used as an adjunct in ambiguous cases, ensuring that clinically obvious torsion goes to theatre immediately and is not delayed by ultrasound. TRIAL REGISTRATION: PROSPERO: CRD42023412619.

Humans

Artificial intelligence for dental caries detection: An umbrella review.

Artificial intelligence (AI) has been proposed as a tool to improve dental caries detection across imaging modalities; however, its clinical value remains uncertain. This umbrella review aimed to synthesize and critically appraise systematic reviews evaluating AI for caries detection and diagnosis. An umbrella review was conducted following PRIOR guidance (PROSPERO CRD420261340728). Searches were performed in MEDLINE, Embase, Scopus, Web of Science, and Google Scholar up to 15 March 2026. Methodological quality was assessed using AMSTAR 2, and overlap of primary studies was quantified using the corrected covered area (CCA). Seventeen systematic reviews were included, of which five reported diagnostic test accuracy meta-analyses using bivariate or HSROC models. Across these meta-analyses, pooled sensitivity ranged from 0.76 to 0.94 and specificity from 0.85 to 0.91. Most systems were based on deep learning models applied to bitewing radiographs and intraoral photographs. However, substantial heterogeneity was observed in imaging modalities, lesion thresholds, analytical tasks, and evaluation metrics. In addition, a high degree of overlap across reviews and recurrent methodological limitations, including reliance on retrospective datasets, limited external validation, and inconsistent reporting, substantially weaken the reliability of the evidence. Although AI models demonstrate high diagnostic performance under experimental conditions, current evidence does not support their use as stand-alone diagnostic tools. Their clinical applicability remains limited, and implementation should be restricted to decision-support contexts until robust prospective validation demonstrates meaningful impact on clinical decision-making and patient outcomes.

Dental Caries

An AI-assisted Clinical Decision Support System for Green Classification of Cystocele on Dynamic Transperineal Ultrasound.

Green classification of cystocele on dynamic transperineal ultrasound (TPUS) remains operator-dependent because it requires manual frame selection and landmark-based assessment of the Valsalva maneuver. We developed a workflow-oriented AI-assisted clinical decision support system for automated urethrovesical junction localization and dynamic Green classification and prospectively evaluated its standalone and reader-support performance. This diagnostic accuracy and reader study included 881 patients from a tertiary referral hospital, comprising a retrospective development cohort (n = 688) and an independent prospective test cohort (n = 193). A nested subset of 67 prospective patients was used for a reader study involving two junior and two intermediate radiologists under unaided and AI-assisted conditions. In the complete prospective test cohort, Green-AttGRU achieved a macro-averaged AUC of 0.939 (95% CI, 0.897-0.971) and an overall accuracy of 0.902 (95% CI, 0.860-0.943). In the reader study, overall accuracy increased from 0.761 to 0.821 without AI to 0.851-0.881 with AI, while macro-F1 increased from 0.660 to 0.777 to 0.820-0.860. Overall inter-reader agreement increased from a Fleiss' κ of 0.453 to 0.786, and pooled median interpretation time decreased from 26.7 s to 9.9 s. These findings support the preliminary feasibility of the system as a workflow-oriented decision-support tool for dynamic TPUS interpretation.

Humans

Premature closure underlies bias in medical diagnosis in students: A randomised controlled experiment.

OBJECTIVE: The purpose of the study reported in this article was to shed light on the cognitive mechanism mediating between biasing information and diagnostic error. The literature suggests at least two different hypotheses: premature closure leading biased participants to spend less time on diagnosis or increased competition between diagnostic hypotheses. The latter hypothesis predicts that biased participants would spend more time reaching a diagnosis. METHOD: Using the salient distracting findings (SDF) experimental paradigm, we biased 58 fourth-year medical students while diagnosing 12 clinical vignettes in a within-group incomplete block design under three conditions: cases presented without SDF, with SDF at the beginning and with SDF at the end. For each of these conditions, diagnostic accuracy, the number of SDF-related mistakes and time per word needed to process the case were recorded. The data were analysed using linear mixed modelling. Estimated marginal mean scores were reported. RESULTS: Participants confronted with salient distracting features (SDFs) at the beginning of a clinical case demonstrated significantly lower diagnostic accuracy (mean 0.11) compared with the No-SDF condition (0.27), representing a 61% reduction (F2,693&#x2009;=&#x2009;11.995, p&#x2009;<&#x2009;0.001), and made more SDF-related mistakes (F2, 693&#x2009;=&#x2009;16.395, p&#x2009;<&#x2009;0.001). When SDFs were presented at the end of the case, diagnostic accuracy was also reduced (mean 0.17; 36% reduction), but processing time did not differ from the No-SDF condition. Only early presentation of SDFs was associated with reduced processing time per word (F2,636&#x2009;=&#x2009;4.799, p&#x2009;<&#x2009;0.01), consistent with premature closure. CONCLUSION: These findings demonstrate that biasing information increases diagnostic error in medical students and that only early bias is associated with reduced information processing. The data do not support the competition hypothesis for early bias, as processing time did not increase under biasing conditions. Premature closure can therefore be directly observed rather than inferred, inviting further research.

Humans

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans

ADAM10's combined influence on the diagnostic usefulness of IL 22, IL 10, IL-17&#xa0;A, and IL-17D in autism spectrum disorders: Predicted role on gut leakiness as co-morbidity.

Autism spectrum disorder (ASD) is a complex neurodevelopmental disorder with increasing global prevalence but a lack of reliable diagnostic biomarkers. Emerging evidence suggests that immune dysregulation, gut-brain axis dysfunction, and increased intestinal permeability play key roles in ASD pathophysiology. This study investigated the combined diagnostic value of ADAM10 and cytokines (IL-10, IL-22, IL-17&#xa0;A, and IL-17D). Multivariable logistic regression produces an improved ROC curve that improves diagnostic accuracy over individual markers by combining numerous predictors into a single risk score (linear predictor). The technique, which frequently raises individual marker AUCs, entails modelling a binary result, calculating the probability, and visualizing ROC based on the projected probabilities. In this case-control study, plasma levels of ADAM10, IL-10, IL-22, IL-17&#xa0;A, and IL-17D were measured in 37 male children with ASD and 37 age-matched controls. Group comparisons, correlation analyses, and receiver operating characteristic (ROC) curve analyses, including combined ROC models, were performed. ADAM10, IL-22, and IL-17&#xa0;A levels were significantly reduced in children with ASD compared to controls, whereas IL-10 and IL-17D showed no significant differences. ADAM10, IL-17&#xa0;A, and IL-22 demonstrated good diagnostic performance, with AUC values of 0.886, 0.855, and 0.812, respectively. In contrast, IL-10 and IL-17D showed poor discriminatory ability, with AUC values of 0.524 and 0.599, respectively. Combined ROC analysis markedly improved diagnostic accuracy, with all panels including ADAM10 achieving AUC values above 0.90, and some reaching as high as 0.988, with high sensitivity and specificity. The combination of ADAM10 with selected cytokines significantly enhances diagnostic performance compared to individual markers, supporting a link between immune dysregulation, barrier dysfunction, and gut permeability in ASD.

Humans

HPV circulating tumor DNA as a potential prognostic and predictive biomarker in head and neck squamous cell carcinoma: a systematic review.

PURPOSE: Human papillomavirus circulating tumor DNA (HPVctDNA) has emerged as a promising prognostic biomarker in HPV-related head and neck squamous cell carcinoma (HNSCC). This systematic review aimed to synthesize current evidence on the diagnostic accuracy and prognostic value of HPVctDNA in HNSCC management. MATERIAL/METHODS: We systematically reviewed a PubMed-indexed database of studies published between January 2012 and September 2025. Eligible studies were assessed for design, primary tumor site and stage, treatment modality, HPVctDNA detection method, diagnostic accuracy (sensitivity and specificity), and reported clinical endpoints. Descriptive syntheses were performed; sensitivity and specificity were standardized to proportions and summarized as median values per group. RESULTS: A total of 60 studies, including 8,234 patients were analyzed, of which 41 (68.3%) focused exclusively on oropharyngeal squamous cell carcinoma (OPSCC) and 17 (28.3%) included mixed HPV-related HNSCC subsites and HPV-positive cancers of unknown primary. The median follow-up across the included studies was 23&#xa0;months. Among the included studies, 19 were retrospective (31.7%) and 33 were prospective (55.0%), with a small proportion of cross-sectional and randomized clinical trials. Overall, 40 (66.7%) evaluated the role of HPVctDNA in a curative setting. Plasma was the most common sample type, analyzed in 55 studies (91.7%), while 5 studies also included saliva. Detection methods varied: 40 employed droplet digital PCR (ddPCR), 16 used quantitative PCR (qPCR) and 4 applied NGS-based assays. Most of these studies (38, 63.3%) evaluated the prognostic utility of HPVctDNA, while only 4 (6.7%) assessed HPVctDNA in a screening or diagnostic setting. Regarding diagnostic accuracy, the median sensitivity across evaluable studies was 91.1%, while the median specificity was 99.4%. In OPSCC-only cohorts, the median sensitivity and specificity were 89.4% and 99.4%, respectively. Dynamic changes in HPVctDNA levels during or after treatment were consistently associated with outcomes: clearance or sustained negativity correlated with higher response rates, improved progression-free survival and overall survival, while persistent positivity or increasing levels predicted disease progression and recurrence. CONCLUSIONS: HPVctDNA demonstrates high diagnostic and prognostic accuracy in HPV-related HNSCC, especially OPSCC, supporting its use for prognosis, treatment monitoring and early detection of recurrence. However, prospective interventional studies are still required to demonstrate that HPVctDNA-guided treatment decisions improve clinical outcomes before routine implementation.

Humans

Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis.

BACKGROUND: Obstructive sleep apnea (OSA) is highly prevalent but remains substantially underdiagnosed. Polysomnography (PSG) is the reference standard, but its cost and limited availability constrain large-scale case identification. AI-based screening tools may support risk stratification and referral prioritization, but their diagnostic accuracy across apnea-hypopnea index (AHI) thresholds remains uncertain. OBJECTIVE: This review aimed to systematically evaluate the diagnostic accuracy of AI-based OSA screening tools at AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, with emphasis on models using non-PSG-derived inputs. METHODS: PubMed, Embase, Scopus, and Web of Science were searched for studies published from January 1, 2016, to May 3, 2026. Eligible studies included adults evaluated for suspected OSA or recruited from population-based cohorts, assessed AI-based models intended or interpretable for OSA screening, risk prediction, or screening-oriented severity classification, used PSG as the reference standard, and reported sufficient data to construct or reconstruct 2&#xd7;2 contingency tables. Diagnostic accuracy was synthesized separately by AHI threshold and input source using bivariate random-effects models, with 95% CIs and prediction intervals (PIs). Risk of bias and certainty of evidence were assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) and GRADE (Grading of Recommendations Assessment, Development, and Evaluation), respectively. RESULTS: A total of 60 studies were included, of which 47 contributed data to the meta-analysis. At AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, pooled sensitivities were 0.94 (95% CI 0.92-0.96; 95% PI 0.71-0.99), 0.87 (95% CI 0.84-0.89; 95% PI 0.66-0.96), and 0.83 (95% CI 0.79-0.87; 95% PI 0.61-0.94), respectively; the corresponding specificities were 0.77 (95% CI 0.69-0.84; 95% PI 0.30-0.96), 0.81 (95% CI 0.75-0.85; 95% PI 0.39-0.96), and 0.91 (95% CI 0.87-0.94; 95% PI 0.55-0.99), respectively. The corresponding areas under the summary receiver operating characteristic curves were 0.943, 0.907, and 0.920. For non-PSG-derived tools, sensitivities were 0.92, 0.85, and 0.81, and specificities were 0.70, 0.74, and 0.85 at the 3 thresholds, respectively. For PSG-derived models, sensitivities were 0.96, 0.90, and 0.85, and specificities were 0.82, 0.88, and 0.96, respectively. Exploratory subgroup analyses suggested performance variation across selected study and model characteristics, including region, algorithmic framework, data source, and validation method. CONCLUSIONS: AI-based tools showed generally favorable screening performance for OSA across clinically relevant AHI thresholds, although wide PIs suggest variable performance across future comparable populations and settings. By synthesizing diagnostic accuracy across 3 AHI thresholds and distinguishing non-PSG-derived from PSG-derived models, this review extends previous broad or modality-specific reviews and offers a clinically interpretable, pathway-specific basis for linking model performance to intended use. The findings may clarify potential roles for non-PSG-derived tools in front-end screening and referral prioritization and for PSG-derived models in reduced-channel assessment and sleep-laboratory workflow support. Given substantial heterogeneity, limited external validation, and low or very low certainty of evidence, prospective validation is needed before routine implementation.

Humans

International study of coronary microvascular angina (iCorMicA): A registry-based diagnostic study and nested randomized trial.

BACKGROUND: Angina is a debilitating condition caused by coronary artery disease and microvascular dysfunction. Following coronary angiography angina and no obstructive coronary arteries is a common outcome, and women are disproportionately affected. The objectives are first, to assess causes of angina in patients undergoing invasive management; and second, to assess effects of coronary function test-guided management on clinical outcomes. METHODS: This is an international, multicenter, prospective, registry-based study and nested, randomized, controlled, triple-blind, and endpoint trial. Participants, community care providers, and outcomes assessors are masked. Consented participants enter the registry. Participants without obstructive coronary artery disease (luminal stenosis <50%, or fractional flow reserve >0.80) are eligible for randomization. Index of microcirculatory resistance (IMR; abnormal &#x2265;25) and coronary flow reserve (CFR; abnormal <2.0; gray zone 2.0-2.5) are measured by bolus thermodilution, and results are disclosed (intervention) or not (control group) to the attending cardiologist. RESULTS: The primary outcome of the registry is the Seattle Angina Questionnaire summary score at baseline described by coronary artery disease status. Secondary outcomes include the prevalence of obstructive coronary artery disease, patient reported outcome measures and clinical outcomes. The primary outcome of the randomized trial is the within-individual change in Seattle Angina Questionnaire summary score at 12-months from baseline. Secondary outcomes include safety, diagnostic accuracy, patient reported outcome measures for quality of life, physical and psychological function, cardiovascular risk, clinical outcomes, health economics and mechanistic biomarkers. The first patient was screened on December 18, 2020 and the last patient was enrolled on June 30, 2026. Forty sites were included in the United Kingdom (n = 35), Republic of Ireland (n = 2), Holland (n = 2), and Poland (n = 1). In total, 1,483 participants were enrolled into the registry of whom 1,047 were randomized and 386 were not randomized (registry-only). CONCLUSION: This international, registry-based clinical trial will provide novel evidence on the natural history of angina and stratified therapy for angina with no obstructive coronary arteries. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/study/NCT04674449. UNIQUE IDENTIFIER: NCT04674449.

Humans

Emerging techniques of CRISPR/Cas system in antiviral therapy and diagnostics: Applications, limitations, and translational perspectives.

The CRISPR/Cas (clustered regularly interspaced short palindromic repeats) system is a versatile technology for developing antiviral medicines and editing viral genomes in both diagnostics and vaccine synthesis. Emerging insights into class 2 effectors, such as Cas9, Cas12, and Cas13, which target viral DNA and RNA, have revolutionized vaccines against viruses such as HIV, HPV, HBV, and EBV. Innovative diagnostic techniques such as SHERLOCK, DETECTR, and FELUDA have demonstrated system's diversity and accuracy in detecting the virus markers, supporting clinical decision-making, indicating adaptability and precision of CRISPR. This review critically evaluates CRISPR's role in RNA editing, emphasizing its importance for functional genomics and development of recombinant vaccines. Translational challenges are critically discussed, including off-target effects, delivery limitations, and ethical issues, for which unique approaches such as high-fidelity Cas variants, non-viral delivery systems, and bioethical frameworks are evaluated to address these limitations. This review also covers other social implications, such as accessibility and biosecurity risks, associated with CRISPR technologies Collectively, these advances underscore the transformative potential of CRISPR technologies in shaping next-generation antiviral diagnostics and therapeutics.

CRISPR-Cas Systems

The role of artificial intelligence in the diagnosis and prognosis of traumatic brain injury based on brain CT scans: a systematic review.

Traumatic brain injury (TBI) is a leading cause of emergency department visits and a major contributor to injury-related mortality and long-term neurological disability. Non-contrast computed tomography (CT) is the gold-standard imaging modality for the rapid diagnosis of TBI. Clinical outcomes depend strongly on early detection and prompt acute management. Artificial intelligence (AI)-based models may support faster automated identification of traumatic findings and early prediction of patient prognosis.&#xa0;A systematic literature search was conducted in PubMed/MEDLINE, Scopus, IEEE Xplore, ACM Digital Library, and the Cochrane Library in accordance with PRISMA 2020 guidelines to evaluate AI-based models for automated detection of TBI-related findings on CT and for prediction of clinical outcomes. Risk of bias and applicability were assessed using QUADAS-2 for diagnostic accuracy studies and PROBAST&#x2009;+&#x2009;AI for prediction model studies.&#xa0;Twenty-two studies were included. Sixteen studies evaluated diagnostic tasks and 10 evaluated prognostic outcomes, with four studies contributing to both categories. Diagnostic performance was generally high, with many studies reporting AUC values approaching or exceeding 0.90, particularly for larger lesion volumes.Prognostic performance was more variable, with moderate to high discrimination and substantial heterogeneity. Only 9 studies incorporated independent external validation, and performance was frequently lower in external cohorts. All prognostic model studies were judged to be at high overall risk of bias using PROBAST&#x2009;+&#x2009;AI, and most diagnostic accuracy studies also demonstrated high or unclear risk of bias in at least one QUADAS-2 domain, most frequently in patient selection.&#xa0;AI-based models applied to brain CT demonstrate strong technical performance for both diagnostic and prognostic tasks in TBI. However, most studies relied on retrospective designs and lacked independent external validation which limits models generalizability and raises concern for potential overfitting. Prospective, multicenter studies with standardized methodologies and rigorous external validation are required before widespread clinical implementation.

Humans

Malaria rapid diagnostic tests: performance, pitfalls, and progress.

PURPOSE OF REVIEW: Malaria rapid diagnostic tests (RDTs) have revolutionized malaria diagnosis in endemic settings. RDTs are simple to use and accurate for clinical cases, although sensitivity is reduced at parasite densities below 200&#x200a;parasites/&#x3bc;l. However, increasing prevalence of hrp2/3 gene deletions in certain areas threaten utility of histidine-rich protein 2 (HRP2)-based RDTs, and lingering HRP2 antigenemia can generate false-positive results after parasite clearance. This review summarizes current performance of malaria RDTs, threats to their validity, and recent innovations to improve their performance and continued role in malaria diagnosis. RECENT FINDINGS: Most World Health Organization (WHO) prequalified RDTs perform well for clinical diagnosis, with only occasional exceptions, including a recently reported issue affecting several countries. RDT sensitivity is generally related to malaria transmission intensity, with higher proportions of false-negative results in lower-transmission areas. Newly prequalified lactate dehydrogenase (pLDH)-based RDTs perform well for both Plasmodium falciparum in areas with >5% hrp2/3 gene deletions&#xa0;and for Plasmodium vivax diagnosis. Several point-of-care alternatives to RDTs, including micro-fluidic devices, hemozoin-detecting devices, and automated hematology analyzers, have shown promising results in small studies, but require larger-scale trials before widespread use. SUMMARY: RDTs remain a critical tool in clinical diagnosis of malaria, and newer pLDH-based tests perform well in areas where hrp2/3 gene deletions threaten validity of HRP2-based RDTs.

Humans

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Ruling out pediatric bacterial epididymo-orchitis with urinalysis - The case for minimizing unnecessary antibiotic prescription.

INTRODUCTION: Epididymo-orchitis in pediatric patients is predominantly non-bacterial, often stemming from viral or reactive etiologies. Despite guidelines recommending conservative management for non-bacterial cases, antibiotic overtreatment remains prevalent in the outpatient setting. We evaluated the diagnostic accuracy of urinalysis in ruling out bacterial infection to support antibiotic stewardship in this population. METHODS: We conducted a cross-sectional diagnostic accuracy study using electronic health records from a large health maintenance organization in Israel. The cohort included patients younger than 18 years with a diagnosis of epididymo-orchitis or clinically overlapping entities (acute scrotum, appendage torsion) who had paired urinalysis and urine culture results within one week of diagnosis. Logistic regression and ROC curve analysis were performed to assess the ability of urinalysis parameters to predict positive urine cultures. RESULTS: Of 682 eligible cases, confirmed bacterial infection was rare, occurring in only 17 patients (2.5%). Nitrite positivity was the strongest independent predictor of infection (OR 43.98; p < 0.001). A prediction model incorporating all urinalysis parameters yielded an area under the curve (AUC) of 0.825 and achieved a 97.7% classification accuracy for correctly predicting negative cultures. Despite the low prevalence of infection, antibiotics were prescribed in 237 cases (34.7%). Urinary anatomic abnormalities were significantly associated with culture positivity. CONCLUSIONS: Bacterial coinfection in pediatric epididymo-orchitis is uncommon. Urinalysis serves as a highly accurate screening tool to rule out bacterial etiology. A negative urinalysis supports withholding antibiotics in this setting, reserving treatment for children with positive markers or known anatomic abnormalities. This evidence-based approach This evidence-based approach has the potential to reduce unnecessary antibiotic exposure, however prospective studies are needed to validate these findings before broad implementation.

Humans

Diagnostic and clinical utility of exome sequencing and chromosomal microarray in children with GDD/iD: a meta-analysis.

BACKGROUND: Global developmental delay/intellectual disability (GDD/ID) is among the most common neurodevelopmental disorders, with up to half of cases are attributed to genetic factors. Chromosome microarray (CMA) has traditionally been the primary genetic test for idiopathic GDD/ID. However, whole exome sequencing (WES) and whole genome sequencing (WGS) have recently emerged, substantially increasing diagnostic yields in these populations. METHODS: We conducted a comprehensive literature search of PubMed, Scopus, EMBASE, and the Cochrane Library from inception to April 29, 2025. Studies reporting the diagnostic utility of these tests in children with GDD/ID were included and analyzed. RESULTS: A total of 102 studies, comprising 55,752 children, were reviewed. The pooled diagnostic yield of WES was 0.37 (95% CI: 0.33-0.41; I2 = 93%), significantly higher than that of CMA at 0.19 (95% CI: 0.16-0.21; I2 = 95%). Subgroup analyses showed that WES yielded significantly higher diagnostic rates than CMA in both same-sample comparisons (OR = 2.27, 95% CI: 1.08-4.78) and different-sample comparisons (OR = 1.65, 95% CI: 1.15-2.37). Only one study evaluated WGS, reporting a diagnostic yield of 0.27. Meta-regression revealed a significant association between CMA diagnostic yield and the proportion of male participants (p&#x2009;<&#x2009;0.01), but not with WES. No significant difference in diagnostic utility was observed between isolated GDD/ID and GDD/ID with comorbidities. CONCLUSION: In children with unexplained GDD/ID, WES demonstrates superior diagnostic and clinical utility compared to CMA. Incorporating WES as a first-line investigation in the diagnostic evaluation of GDD/ID may be warranted.

Humans

A review into the recent advances in the world of amoebiasis.

PURPOSE OF REVIEW: Amoebiasis is a parasitic infection caused by Entamoeba histolytica , affecting 10% of the global population. It is a well recognized cause of morbidity and mortality in low-middle-income countries where it is endemic. However, with increased migration and global travel, amoebiasis is now more common in high-income countries, although diagnosis is often delayed or even missed due to lack of awareness of the latest epidemiology and optimal diagnostic testing. This review discusses the evolving prevalence, and the current international guidelines for the investigation and treatment of amoebiasis, focusing on recent advances. RECENT FINDINGS: The recent literature shows that the primary investigations for amoebiasis remain the same, though newer modalities such as artificial intelligence-powered microscopy and metagenomics have been developed recently, which aids the accuracy and speed of diagnosis. Treatment remains the same, though current research has found potential new drugs and drug targets which show promise. SUMMARY: This review reinforces the importance of early clinical suspicion, diagnosis and treatment for amoebiasis. What was once a disease only seen in endemic countries or travel-associated imported cases is now more common and must not be missed.

Humans

Assessment of atypical glandular cell interpretation in Pap tests using the Hologic Genius Digital Diagnostics System.

Atypical glandular cells (AGC) are a diagnostic challenge. The aim of this study was to evaluate the efficacy and diagnostic performance of AGC detection on the Hologic Genius Digital Diagnostics System (HGDDS). A retrospective analysis of 451 ThinPrep Pap cases was conducted, including 207 cases of AGC, 27 cases of high-grade squamous intraepithelial lesion (HSIL), 25 cases of low-grade squamous intraepithelial lesion (LSIL), and 192 benign cases. All AGC cases had follow-up histologic diagnoses, with 66 cases subsequently diagnosed as adenocarcinoma. The slides were randomized, scanned, and analyzed by the HGDDS. Patient age and HPV test results were provided to reviewers, an experienced cytologist, who screened the cases, followed by two cytopathologists who independently examined the cases on the HGDDS. Diagnostic concordance between the two cytopathologists indicated strong agreement (&#x3ba; = 0.829). Sensitivity of AGC on Papanicolaou (Pap) tests for adenocarcinoma detection on HGDDS was 98.5% and 95.5%, respectively, comparable to the original ThinPrep interpretation (OTPI). Specificity for adenocarcinoma detection was significantly higher (84.6% and 85.6%) with the HGDDS than 27.7% with OTPI. Overall, the diagnostic performance for AGC/HSIL interpretation to detect CIN2/3/adenocarcinoma appeared to have improved with HGDDS compared with OTPI, particularly for specificity and positive predictive value (PPV). This is the first study evaluating AGC diagnosis using the HGDDS. The findings demonstrate that the sensitivity of adenocarcinoma detection as AGC on HGDDS is comparable to the ThinPrep Imaging System, but the specificity and PPV are improved. This suggests the potential of artificial intelligence to augment the performance of cervical cancer screening.

Humans

Recent advances in Strongyloides screening, diagnostics, therapeutics, and management.

PURPOSE OF REVIEW: Strongyloidiasis affects an estimated 30-100 million people globally and can have life-threatening consequences in immunocompromised hosts, yet it remains underdiagnosed due to limited access and performance of available diagnostics. Novel assays and anthelmintics may reshape screening, diagnosis, treatment, and prevention for at-risk populations. RECENT FINDINGS: Advances in molecular diagnostics coupled with robust stool extraction methods have supplanted traditional parasitologic methods in settings where nucleic acid amplification is feasible. Transition from standard immunoglobulin G (IgG)-based immunoassays to the new IgG- and IgG4-based rapid diagnostic tests using recombinant Strongyloides stercoralis nematode immunodominant E antigen (NIE) and/or S. stercoralis immunoreactive antigen (SsIR) has facilitated serologic screening at the point of care. The World Health Organization now conditionally recommends community-wide ivermectin mass drug administration in highly endemic settings. Regarding new treatment options, moxidectin is noninferior to ivermectin with 93-94% cure rates and a longer half-life, while emodepside shows 80-90% predicted cure rates in early trials and offers a mechanistically distinct option. Understanding of immunosuppressed populations at risk for hyperinfection has expanded, prompting updated screening recommendations. SUMMARY: Serologic and molecular tools are improving screening and diagnosis, and moxidectin and emodepside may broaden treatment options, but data in severe disease and special populations remain limited. Priorities include harmonized screening algorithms and prospective studies in high-risk groups.

Humans