Search PubMedSearch

SEARCH · Search PubMed

Results for “biomedical coatings”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

50 records · Page 2Linked to original sources

Mitigating pH-induced instability in deruxtecan-based ADCs: an onboard-mixing icIEF approach for robust charge heterogeneity characterization.

Accurate charge variant analysis of antibody-drug conjugates (ADCs) is essential for understanding product heterogeneity and ensuring quality control. However, Deruxtecan (DXd)-based ADCs present a unique analytical challenge due to the intrinsic instability of the payload, where the lactone ring readily undergoes hydrolysis under alkaline conditions, resulting in time-dependent shifts in charge distribution during imaged capillary isoelectric focusing (icIEF). In this study, we describe the development of an onboard-mixing icIEF method designed to minimize pH-induced degradation during sample preparation. By separating ADC samples from carrier ampholytes (CAs) prior to injection and enabling real-time mixing within the instrument, this approach effectively suppresses premature lactone ring opening and stabilizes charge variant profiles. Comparative studies between conventional premixing and onboard-mixing approach demonstrated that the latter significantly enhances reproducibility, particularly for acidic variants that are highly sensitive to structural conversion. Comprehensive method validation confirmed excellent precision, linearity, and sensitivity, with consistent performance across run-to-run and intra-day analyses. The results underscore the importance of controlling microenvironmental pH exposure in the analysis of chemically instable ADCs. The proposed onboard-mixing strategy provides a robust and efficient solution for icIEF-based characterization, reducing analytical artifacts while simplifying method development. This approach is broadly applicable to ADCs and other biotherapeutics containing pH-sensitive functional groups.

Hydrogen-Ion Concentration

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50 μM, and intracellular concentrations and cell viability were monitored over 48 h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Overcoming Immunological Barriers in MSC-Derived Insulin-Producing Cells through CRISPR-Based Hypoimmunogenic Engineering and Translational Perspectives for Type 1 Diabetes.

Mesenchymal stromal cell (MSC)-derived insulin-producing cells (IPCs) represent an emerging strategy for β-cell replacement in type 1 diabetes mellitus (T1DM) owing to their differentiation potential, intrinsic immunomodulatory properties, and lower tumorigenic risk compared with pluripotent stem cell-derived platforms. However, accumulating evidence indicates that differentiation-associated immunogenicity, context-dependent immune recognition, and recurrent autoimmune responses may substantially limit long-term graft survival and therapeutic durability following transplantation. This review critically examines the immunological barriers associated with MSC-derived IPCs, including altered MHC expression, susceptibility to alloimmune and autoimmune-mediated rejection, and potential reactivation of autoreactive immune memory. We discuss the application of CRISPR-based hypoimmunogenic engineering strategies targeting antigen presentation pathways, NK-cell activation, and immune checkpoint modulation to generate more immune-evasive MSC-derived IPCs while preserving β-cell functionality. By integrating insights from T1DM immunopathogenesis, MSC biology, genome editing, and translational immunology, we propose a framework linking immune engineering with controlled differentiation, functional maturation, and long-term safety evaluation. In parallel, we comparatively position MSC-derived IPCs alongside clinically advancing iPSC-derived β-cell platforms to highlight their distinct translational niche, including potential advantages related to safety, immunomodulatory capacity, manufacturing accessibility, and scalability, while acknowledging the superior functional maturity and clinical progression currently demonstrated by iPSC-derived systems. Finally, we discuss key translational challenges, including genomic stability, immune-evasion durability, GMP-compliant manufacturing, and the need for rigorous functional and immunological benchmarking prior to clinical application of hypoimmunogenic MSC-derived IPC therapies in T1DM.

Humans

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700 ng/mL), with detection limits (LOD) as low as 0.05 ng/mL. Quantification limits ranged from 3 to 5019 ng/mL (LLOQ) and up to 16,700 ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n = 50) of articles showed low risk-of-bias, while 7.4% (n = 4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Improved comprehensive profiling of fecal bile acids through chemical derivatization combined with HPLC-MS/MS analysis.

Bile acids (BAs) facilitate the digestion and absorption of fats and influence lipid and glucose homeostasis, making them potential therapeutic targets for obesity and related metabolic disorders. The liver and intestinal microbiota modify BAs structurally, generating diverse chemical forms and isomers. Comprehensive profiling of the BA pool is critical for understanding their key biological functions and as a therapeutic approach for related diseases. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is usually chosen as the preferred method for BA detection due to the complex chemical structures, the wide range of actual concentrations and the complexity of fecal sample matrices. However, free BAs are difficult to ionize, resulting in low detection signals and a lack of characteristic structural fragments to assist in structural identification. In this method, the labeling reagent (2-aminoethyl) trimethylammonium (AETMA) is employed to label the carboxyl group of BAs. Compared with underivatized BAs, the detection sensitivity of unconjugated BAs was enhanced by 25-180 fold, while that of conjugated BAs increased by 6-160 fold. It also generates unique fragment ions and enhances MS response, facilitating the discovery of potential BAs. Methodological parameters were validated using 38 BAs as representatives. Through methodological validation, it was verified that the precision, recovery, matrix effect and stability parameters of the method met acceptable criteria. We also identified 61 confirmed BAs and 55 additional candidate BAs in human pooled fecal samples. It has been successfully applied to fecal BA analysis in obese populations, providing valuable insights into potential therapeutic strategies for obesity.

Tandem Mass Spectrometry

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236&#xa0;nm, emission 340&#xa0;nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125&#xa0;&#xd7;&#xa0;4.0&#xa0;mm, 5&#xa0;&#x3bc;m) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8&#xa0;mL/min. The method showed excellent linearity (r&#xa0;>&#xa0;0.999) over 0.01-1.0&#xa0;&#x3bc;g/mL for IMQ and 0.1-2.0&#xa0;&#x3bc;g/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001&#xa0;&#x3bc;g/mL for IMQ and 0.004&#xa0;&#x3bc;g/mL for TBF, with quantification limits of 0.02&#xa0;&#x3bc;g/mL and 0.16&#xa0;&#x3bc;g/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

Fatty acids and breast cancer: Epidemiology, subtype-specific metabolism, immune regulation, and clinical translation.

Fatty acids (FAs) are bioactive dietary and metabolic molecules that participate in membrane architecture, energy homeostasis, inflammatory signaling, gene regulation and immune function, all of which intersect with breast cancer (BC) risk, progression and treatment response. In this narrative review we integrate epidemiological, clinical, translational and mechanistic evidence on the role of FAs in BC. Saturated, monounsaturated, trans- and polyunsaturated FAs (PUFAs) are treated as distinct biological exposures rather than interchangeable measures of total fat intake. Similarly, evidence from dietary assessment, circulating biomarkers, erythrocyte membrane composition, adipose tissue stores and tumor lipid signatures is interpreted separately, because each captures exposure and biology at a different level. BC subtypes differ in FA synthesis, uptake, oxidation, storage and remodeling: luminal tumors are frequently linked to hormone-regulated lipogenesis, human epidermal growth factor receptor 2 (HER2)-positive tumors to growth-factor-driven lipid metabolism, and triple-negative tumors to exogenous FA uptake, inflammatory lipid mediators and ferroptosis-related vulnerabilities. FA-derived mediators also shape immune-cell polarization, cytokine signaling and the tumor microenvironment, and dietary FAs may reshape the gut microbiota; the fiber-derived short-chain FAs it produces, distinct from dietary FAs, likewise help regulate immune and inflammatory tone. Clinical data suggest possible roles for fat-quality modification and selected n-3 PUFA interventions, but findings are heterogeneous and not yet sufficient to support routine biomarker-guided precision onco-nutrition. Candidate biomarkers, such as erythrocyte n-6:n-3 composition, require prospective validation before clinical implementation. FA biology thus represents a modifiable but complex axis in BC prevention, tumor biology and supportive care.

Humans

A validated sensitive LC-MS/MS method and its application in elucidating the unique ocular pharmacokinetic profile of 0.01% atropine underpinning its clinical utility for myopia.

A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify atropine in ten rabbit ocular tissues enabling systematic characterization of the ocular pharmacokinetic profile of 0.01% atropine sulfate eye drops after a single topical administration. The method demonstrated excellent linearity (coefficient of determination, R2&#xa0;&#x2265;&#xa0;0.9908) across all matrices, with lower limits of quantification (LLOQ) of 0.05&#xa0;ng/mL for most tissues and 0.10&#xa0;ng/mL for retina and lens; intra- and inter-day accuracy, precision, matrix effects, extraction recoveries, and stability all met the acceptance criteria. Following a single bilateral topical dose (50&#xa0;&#x3bc;L/eye) in New Zealand White rabbits, atropine distributed rapidly into all 12 ocular compartments (the sclera further divided into three anatomical regions) with marked heterogeneity-the highest exposures were found in conjunctiva and cornea, a distinct anterior-to-posterior concentration gradient was observed in the sclera, sustained retention was noted in the retina (mean residence time from zero to the last measurable time point, MRT0-t 3.30&#xa0;h), while aqueous and vitreous humor eliminated rapidly (elimination half-life, t&#x2081;/&#x2082;&#xa0;<&#xa0;0.7&#xa0;h), and all tissues except aqueous humor followed a two-compartment model. This validated method and the comprehensive pharmacokinetic data reveal that topically applied 0.01% atropine achieves sustained exposure in key myopia-regulating tissues (retina, choroid, posterior sclera) with low exposure in side-effect target tissues (iris, ciliary body, lens).

Animals

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000&#xa0;nM. However, due to carry-over observed at 10,000&#xa0;nM, the validated calibration range was established at 1-2000&#xa0;nM, with matrix-dependent LLOQs of 1-10&#xa0;nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20&#xa0;ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r&#xa0;=&#xa0;0.926). PFOS was the only compound detected at concentrations &#x2265;0.2&#xa0;ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50&#xa0;ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Unravelling bioanalytical innovations, degradation processes, and impurity landscapes of VEGFR inhibitors.

From pre-formulation studies to clinical trials, VEGFR-targeted small-molecule tyrosine kinase inhibitors (TKIs) require rigorous analytical standards. Bioanalysis, stability-indicating studies, and impurity profiling are used to examine chromatographic advances for VEGFR-targeted TKIs like sunitinib, pazopanib, axitinib, sorafenib, cabozantinib, vandetanib, apatinib, lenvatinib, nintedanib, and regorafenib. An LC-MS/MS and UPLC-MS/MS routinely show sub ng/mL performance, as shown by LLOQs (0.2&#xa0;ng/mL) for sunitinib and axitinib, 1&#xa0;ng/mL for pazopanib, 5-7&#xa0;ng/mL for sorafenib, 0.5-1.5&#xa0;ng/mL for regorafenib metabolic products, and 0.1-0.5&#xa0;ng/mL for lenvatinib. These approaches are used for pharmacokinetics and therapeutic drug monitoring due to their good correlation coefficient of 0.1-10,000&#xa0;ng/mL, accuracy of 95%-108%, and precision of 15% RSD. UPLC-QTOF-MS/MS distinguishes degradants and metabolites during forced degradation studies, enabling structural elucidation following ICH M7 risk evaluation protocol. HPTLC/MLC offers fast, sensitive screenings, while RP-HPLC/DAD or HPLC-UV offer reliable, cost-effective routine quality-control solutions with LOD/LOQ in the &#x3bc;g/mL range and linearity of 10-240&#xa0;&#x3bc;g/mL. This review lists the structures and CAS numbers of ten VEGFR-2 TKI degradants and metabolites, as well as pharmacopeial impurities in SMILES forms. It will be useful for future method development and regulatory applications. To ensure VEGFR-targeted TKI quality, safety, and therapeutic efficacy, LC-MS/MS for trace quantification and HRMS for structure elucidation provide a robust, future-oriented framework. To improve VEGFR-targeted TKI quality, safety, and regulatory compliance, analytical development should focus on HRMS-based impurity characterization, AI-assisted degradation prediction, green chromatography, and harmonized bioanalytical validation.

Humans

Efficacy and safety of mitapivat in adults with transfusion-dependent &#x3b1;-thalassaemia or &#x3b2;-thalassaemia (ENERGIZE-T): a double-blind, randomised, multicentre, placebo-controlled, phase 3 trial.

BACKGROUND: The absence of disease-modifying therapies for patients with &#x3b1;-thalassaemia and oral disease-modifying therapies for patients with &#x3b2;-thalassaemia has been a substantial unmet need in these patients. We assessed the efficacy and safety of mitapivat, an oral allosteric activator of pyruvate kinase, in adults with transfusion-dependent thalassaemia. METHODS: ENERGIZE-T is a global, double-blind, randomised, placebo-controlled, phase 3 trial, conducted across 19 countries in North America, Europe, Asia-Pacific, South America, and the Middle East. Patients aged 18 years or older with transfusion-dependent &#x3b1;-thalassaemia or &#x3b2;-thalassaemia were randomly allocated (2:1) with a central interactive response technology system, stratified by geographical region and thalassaemia genotype, to receive 100 mg mitapivat or placebo orally twice a day for 48 weeks. The primary endpoint was transfusion reduction response (TRR), defined as a reduction of at least 50% in transfused red blood cell units with a reduction of at least two units in any consecutive 12-week period until week 48 compared with baseline. Efficacy was analysed in the full analysis set, comprising all randomly allocated patients. Type, severity, and relationship of adverse events and serious adverse events were assessed in patients who received at least one dose of study treatment. This study is registered with ClinicalTrials.gov (NCT04770779) and is active but not recruiting. FINDINGS: Between Nov 30, 2021 and May 2, 2023, 305 patients were screened, of whom 258 were randomly allocated (median age 33&#xb7;5 years [IQR 27&#xb7;0-44&#xb7;0]; 136 [53%] female and 122 [47%] male participants). Of 258 patients allocated, 238 (92%) completed the double-blind treatment period. All patients were required to have a safety follow-up approximately 4 weeks after the final dose of study drug, regardless of completion of the double-blind period or continuation into the open-label extension period. In the full analysis set, TRRs occurred in 52 (30%) of 171 patients in the mitapivat group and 11 (13%) of 87 in the placebo group (adjusted difference 18 percentage points [95% CI 8-27]; two-sided p=0&#xb7;0003). The safety analysis set comprised 172 patients in the mitapivat group (including one patient allocated to the placebo group who received one dose of mitapivat in error) and 85 in the placebo group. Adverse events were reported in 155 (90%) patients treated with mitapivat and 71 (84%) treated with placebo; the most common events with mitapivat were headache, upper respiratory tract infection, initial insomnia, diarrhoea, and fatigue. Serious adverse events were reported in 19 (11%) patients treated with mitapivat and 13 (15%) treated with placebo. Ten (6%) patients who received mitapivat and one (1%) who received placebo discontinued study treatment due to adverse events. No deaths were reported. INTERPRETATION: Mitapivat significantly reduced the transfusion burden and was generally well tolerated, showing a favourable benefit-risk profile. These findings support mitapivat as the first oral disease-modifying therapy for adults with transfusion-dependent &#x3b1;-thalassaemia or &#x3b2;-thalassaemia, providing a new treatment option to reduce transfusion burden in this patient population. FUNDING: Agios Pharmaceuticals, Inc.

Adult

Adeno-Associated Virus Gene Therapy Translation: Lessons from Early Regulatory Meetings.

The Platform Vector-Gene Therapy (PaVe-GT) program is a National Institutes of Health (NIH) initiative that aims to develop adeno-associated virus (AAV) gene therapies for four monogenic rare diseases, two organic acidemias and two congenital myasthenic syndromes. PaVe-GT's platform-based approach identifies and diminishes redundancies and applies efficiencies in preclinical, clinical, and regulatory activities. The program's hypothesis is that implementing these efficiencies can accelerate clinical trial initiation. Based on its platform-centric experience and public-serving mission, the PaVe-GT program actively shares its scientific and regulatory learnings with the public to benefit the development of similar gene therapy products for rare diseases. PaVe-GT's first investigational AAV gene therapy candidate is AAV serotype 9 human propionyl-CoA carboxylase alpha subunit (AAV9-hPCCA) for propionic acidemia caused by PCCA deficiency, which received initial feedback from the Food and Drug Administration (FDA) in an INitial Targeted Engagement for Regulatory Advice on CBER/Center for Drug Evaluation and Research (CDER) ProducTs (INTERACT) meeting. Upon further product development that took into consideration the FDA's initial advice, the program obtained the Agency's feedback in pre-investigational new drug (IND) (Type B) and Type C meetings. Here, we share our experience from these meetings, including strategy, preparation, pre- and post-meeting feedback from the FDA, and lessons learned during the AAV9-hPCCA regulatory process, which the program plans to apply across the PaVe-GT platform. Topics discussed in the regulatory meetings included animal model and efficacy studies, toxicology study plans, manufacturing of the investigational AAV product, and clinical trial design. The main lessons learned from the pre-IND and Type C meetings for AAV9-hPCCA are: (1) Pharmacology/Toxicology studies in a single rodent species are sufficient for filing an initial IND; (2) FDA feedback guides product quality improvements and early development of a quantitative potency assay; (3) use of biomarkers as potential surrogate endpoints in a future efficacy trial benefits from collection of data in the natural history study and the first-in-human Phase 1/2 study; and (4) evidence from the Phase 1/2 clinical trial could be leveraged to support a license application. Lightly redacted regulatory documents and comprehensive templates developed by the PaVe-GT team are available on the PaVe-GT website.

Dependovirus

Selective monitoring of trace-level catechin and myricetin in herbal and aqueous matrices using magnetic MIP-DSPME: Optimization via design of experiments.

A novel dispersive solid-phase microextraction approach utilizing a magnetic molecularly imprinted polymer (MMIP) integrated with HPLC-UV detection was developed for the concurrent quantification of catechin and myricetin in herbal extracts and aqueous samples. The sorbent was engineered as a core-shell nanocomposite, consisting of a selective polymer layer deposited onto Fe3O4@SiO2-APTMS magnetic nanoparticles. Dual-template imprinting using catechin and myricetin generated complementary binding cavities within the polymer framework. Experimental variables influencing extraction were systematically screened and subsequently optimized. A Plackett-Burman design was first applied to identify the most influential factors, with pH and sorption time identified as the dominant variables. These parameters were subsequently fine-tuned using a central composite design, and the optimization process was completed in only 30 experimental runs. The sorption characteristics of the imprinted sorbent (MMIP) were compared with those of its non-imprinted counterpart (MNIP). The MMIP demonstrated markedly higher maximum binding capacities (Qmax), reaching 119.3&#xa0;mg&#xa0;g-1 for myricetin and 112.1&#xa0;mg&#xa0;g-1 for catechin, whereas the corresponding values for the MNIP were 32.55 and 32.08&#xa0;mg&#xa0;g-1, respectively. Moreover, the affinity constants (KL&#xa0;=&#xa0;0.760-0.950&#xa0;L&#xa0;mg-1) were approximately 2.3-fold higher for the MMIP, confirming its stronger and more selective interactions with the target analytes. The selectivity coefficients for the targeted flavonoids relative to structurally related compounds, including ferulic acid, p-coumaric acid, melatonin, and curcumin, exceeded 3.5 for the MMIP, whereas the corresponding values for the MNIP were close to 1.1, demonstrating the high molecular recognition capability of the imprinted sorbent. Method validation demonstrated limits of detection (LODs) of 0.33-0.59&#xa0;ng&#xa0;mL-1 and limits of quantification (LOQs) of 1.10-1.96&#xa0;ng&#xa0;mL-1, and excellent linearity over the concentration range of 5.0-5500&#xa0;ng&#xa0;mL-1 (R2&#xa0;>&#xa0;0.998). The method achieved recoveries of 93.96% to 105.69% with RSDs below 5.5%, while the preconcentration factors ranged from 209 to 229. Furthermore, the sorbent retained more than 95% of its extraction efficiency after four consecutive reuse cycles and more than 80% after six cycles, demonstrating excellent stability and reusability. The proposed method was successfully applied to the analysis of six medicinal plant extracts and water samples, showing negligible matrix interference and superior sensitivity, selectivity, and operational simplicity compared with conventional solid-phase extraction methods.

Flavonoids

Morphology-engineered NiFe@C nanocages boosting electrochemical quantification of ractopamine in meat samples.

It is essential to acquire efficient electrocatalysts to develop ractopamine (RAC) electrochemical sensors. Herein, we report the synthesis of a series of carbon coated NiFe alloy nanostructures (e.g., NiFe@C nanoparticles, nanocubes and nanocages) using NiFe Prussian blue analogue (PBA) as the precursor. The NiFe@C nanocages exhibited the best electrocatalytic performance for RAC sensing. This is attributed to the embedded NiFe alloy nanoparticles that provide abundant active sites, and the unique nanocage structure facilitates electron transfer pathways while offering a high specific surface area. The resulting sensor achieves a low detection limit (LOD) of 54&#xa0;nM (S/N&#xa0;=&#xa0;3) within a linear range of 0.2-12&#xa0;&#x3bc;M. Moreover, the sensor demonstrates good reproducibility, stability, and excellent long-term stability. Practical applicability was confirmed in meat samples, yielding satisfactory recovery rates ranging from 98% to 108%. A feasible strategy was introduced herein for rational design of metal@carbon electrocatalysts.

Phenethylamines