Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “biomedical coatings”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Lactic acid-stabilised albumin for microsphere formulation and biomedical coatings.

Microspheres of ovalbumin (OVA) ranging from 1 to 15 microm were prepared by emulsifying an aqueous solution of albumin in soya oil at room temperature then raising the temperature to 45 degrees C for 30 min, prior to harvesting of the microspheres. Production of OVA nanospheres with size less than 500 nm was achieved by desolvation from aqueous albumin solutions using acetone. In both cases, lactic acid was added to the starting albumin solution to stabilise the resulting particles. Utilisation of an endogenous substance avoids the use of chemical crosslinking agents such as glutaraldehyde and associated toxicological concerns. Protein coating of knitted Dacron vascular grafts was performed by impregnation of the textile structure with lactic acid-stabilised ovalbumin nanospheres thereby providing a surface potentially resistant to blood platelet adhesion but conducive to endothelialisation. Protein release testing carried out in PBS at 37 degrees C revealed that approximately 60% of the original albumin coating was retained by the Dacron graft material after 4 days and remained at this level for upto 4 weeks. Apart from the formulation of albumin microspheres for drug delivery, diagnostic applications and coating of biomedical textiles, the process of albumin stabilisation using lactic acid may be usefully applied to improve protein immobilisation on a wide range of biomaterial surfaces.

Blood Vessel Prosthesis↗

Addressing processing problems associated with plasma spraying of hydroxyapatite coatings.

Biomedical coatings generally have to satisfy specific requirements such as a high degree of crystallinity (for positive biological responses), good coating adhesion and optimal porosity. These are necessary to enhance biocompatibility, accelerate post-operative healing and improved fixation. Thermal spray processes have been frequently used to deposit functionally active biomedical coatings, such as hydroxyapatite (HA), onto prosthetic implants. The benefits of HA materials in coated implants have been widely acknowledged, but the occurrence of several poor performances has generated concerns over the consistency and reliability of thermally sprayed HA coatings. Recent investigations using HA coatings have shown that process related variability has significant influence on coating characteristics such as phase composition, structure and chemical composition and performance such as bioresorption, degradation and bone apposition. Variation in process parameters such as powder morphology can induce microstructural and mechanical inconsistencies that have an effect on the service performance of the coating. In order to reach some acceptable level of reliability, it may be necessary to control existing variability in commercially available HA feedstock. In addition, certain opposing factors severely constrain the means to achieve the necessary coating conditions via thermal spraying alone; therefore, creating the need to introduce other innovative or secondary treatment stages to attain the desired results. This paper highlights some of the problems associated with plasma spray coating of HA and suggests that tailoring the powder feedstock morphology and properties through suitable conditioning processes can aid the deposition efficiency and produce an acceptable coating structure.

Aerosols↗

Biomedical coatings to improve the tissue-biomaterial interface.

One of the most important factors determining the degree of tissue interaction of an implanted device is the property of its surface. Thus, great importance is given to chemical and morphological characteristics of biomaterial surfaces to improve biocompatibility, cell migration, proliferation and differentiation, mechanical stability and endogenous tissue ingrowth. In order to obtain new and healing stimulating properties, it is possible to apply a coating or more generally a surface treatment to the surface of a prosthetic device. One of the most versatile methods for coating is thermal spray technology. This paper considers the principle of thermal spray processes and their application in the biomedical field, namely the coatings used for orthopedic prostheses and dental implants. Among thermal spray processes, plasma spray as well as High Velocity Oxygen Fuel (HVOF) processes will be particularly considered and their most important aspects will be illustrated.

Bone Substitutes↗

Biomedical coatings based on chitin soluble extract for inhibition of fungal adhesion to polymeric surfaces.

Indwelling medical devices made of polymeric materials, such as intravenous (IV) catheters, are known risk factors for development of fungal infection, particularly systemic candidiasis, that are a significant cause of morbidity and lethality in compromised patients. Candida can form a biofilm on the polymeric surface, serving as a nidus for systemic, difficult to eradicate infection. The current research focuses on development and study of a chitin soluble extract (CSE) coating on polyurethane (PU), in order to reduce the level of adherence of C. albicans to the PU surface. The immobilization of CSE onto the PU surface was performed using both, chemical binding and physical adsorption. Our results indicate that CSE develops a unique tertiary structure in which basic elements in the range of 100 nm build "fingers" and these "fingers" are arranged in a concentric structure around a center. The CSE coated films showed 75% inhibition of C. albicans adhesion for the chemical binding and 83% for the physical adsorption coating and even after 11 weeks the inhibitory effect on adhesion is still significant. Hence, our new coatings may lead to a new generation of medical devices with surfaces that can prevent fungal adhesion.

Candida↗

Novel silicon-doped hydroxyapatite (Si-HA) for biomedical coatings: an in vitro study using acellular simulated body fluid.

Magnetron co-sputtering was used to produce silicon-doped hydroxyapatite (Si-HA) as coatings intended for potential applications such as orthopedic and dental implants. It was found that the crystallinity of the as-sputtered coatings increased after annealing, resulting in a nanocrystalline apatite structure. Subsequently, the bioactivity of the coatings was evaluated in an acellular simulated body fluid (SBF). Physicochemical evaluation demonstrated that a carbonate-containing apatite layer, which is essential for bonding at the bone/implant interface, was formed on the coating surfaces after immersion in SBF between 4 and 7 days. The annealed coatings exhibited enhanced bioactivity and chemical stability under physiological conditions, as compared with the as-sputtered coatings. It is proposed that the rate at which the carbonate-containing apatite layer forms is dependent on the scale factor of the structure. A nanocrystalline structure can provide a higher number of nucleation sites for the formation of apatite crystallites, leading to a more rapid precipitation of carbonate-containing apatite layer. This work shows that Si-HA coatings offer considerable potential for applications in hard tissue replacement, owing to their ability to form a carbonate-containing apatite layer rapidly.

Body Fluids↗

[Studies on crosslinkable coatings for biomedical application].

A novel crosslinkable coating for biomedical device was prepared by copolymerization of the constituent monomers via a free radical method. 1H-NMR and IR results indicated it had desirable structure. Surface characterization revealed that surface reorganization occurred in aqueous environment and a polyethylene oxied (PEO) enrichment surface was developed on coated surface. The in-vitro platelet-adhesion test and the plasma recalcification time(PRT) determination showed that the coated surface could resist the blood coagulation effectively.

Blood Coagulation↗

A preliminary report on a novel electrospray technique for nanoparticle based biomedical implants coating: precision electrospraying.

The compatibility and biological efficacy of biomedical implants can be enhanced by coating their surface with appropriate agents. For predictable functioning of implants in situ, it is often desirable to obtain an extremely uniform coating thickness without effects on component dimensions or functions. Conventional coating techniques require rigorous processing conditions and often have limited adhesion and composition properties. In the present study, the authors report a novel precision electrospraying technique that allows both degradable and nondegradable coatings to be placed. Thin metallic slabs, springs, and biodegradable sintered microsphere scaffolds were coated with poly(lactide-co-glycolide) (PLAGA) using this technique. The effects of process parameters such as coating material concentration and applied voltage were studied using PLAGA and poly(ethylene glycol) coatings. Morphologies of coated surfaces were qualitatively characterized by scanning electron microscopy. Qualitative observations suggested that the coatings were composed of particles of various size/shape and agglomerates with different porous architectures. PLAGA coatings of uniform thickness were observed on all surfaces. Spherical nanoparticle poly(ethylene glycol) coatings (462-930 nm) were observed at all concentrations studied. This study found that the precision electrospraying technique is elegant, rapid, and reproducible with precise control over coating thickness (mum to mm) and is a useful alternative method for surface modification of biomedical implants.

Coated Materials, Biocompatible↗

Flexible and insulative Plasmalene wire coatings for biomedical applications.

A novel polymeric material, Plasmalene, was synthesized and tested as a functional hermetic polymer coating on Gold, Platinum, and MP35N wire substrates. The flexible Plasmalene polymer coatings were synthesized onto wire substrates by vacuum processes which included radio frequency (RF) initiated plasma polymerization and thermal vapor deposition of methane and xylylene monomers. Mechanical and electrical tests were performed on 75 micron wires coated with either Plasmalene, Parylene, or Teflon polymers. The coated wire substrates were mounted on a flex testing machine that was submerged in a saline bath. A +5VDC electrical bias was continuously applied between the wire substrates and the bath. The flex testing machine mechanically stressed the coatings for 50,000 cycles with tensile and compressive loadings of up to 11% strain. The cyclic strain was applied through a total flexural arc of 170 degrees. Electrical leakage currents were measured through the polymer films to the saline bath at +5VDC versus a Ag/AgCl reference electrode. Analysis of the leakage current data for the Parylene and Teflon coated wires indicated that there was a significant (alpha = 0.05) increase, up to microampere levels, in leakage currents through the films as a result of repeated cyclic stressing. Plasmalene coated wires showed no significant increase in initial picoampere leakage currents with cycling and therefore, demonstrated that a superior insulative and mechanically durable film can be synthesized as a wire encapsulant.

Artificial Organs↗

Control of phase composition in hydroxyapatite/tetracalcium phosphate biphasic thin coatings for biomedical applications.

Biphasic calcium phosphates comprising well-controlled mixtures of nonresorbable hydroxyapatite and other resorbable calcium phosphate phases often exhibit a combination of enhanced bioactivity and mechanical stability that is difficult to achieve in single-phase materials. This makes these biphasic bioceramics promising substrate materials for applications in bone tissue regeneration and repair. In this paper we report the synthesis of highly crystalline, biphasic coatings of hydroxyapatite/tetracalcium phosphate with control over the weight fraction of the constituent phases. The coatings were produced by pulsed laser deposition using ablation targets of pure crystalline hydroxyapatite. The fraction of tetracalcium phosphate phase in the coatings was controlled by varying the substrate temperature and the partial pressure of water vapor in the deposition chamber. A systematic study of phase composition in the hydroxyapatite/tetracalcium phosphate biphasic coatings was performed with X-ray diffraction. Tetracalcium phosphate in the coatings obtained at high substrate temperature is not formed by partial conversion of previously deposited hydroxyapatite. Instead, it is produced by nucleation and growth of tetracalcium phosphate itself from the ablation products of the hydroxyapatite target or by accretion of tetracalcium phosphate grains formed during ablation. This finding was confirmed by formation of calcium oxide, not tetracalcium phosphate, after annealing of pure hydroxyapatite coatings at high temperatures of 700-850 degrees C.

Biomedical Engineering↗

A novel crosslinkable polymer as drug-loaded coating for biomedical device.

A novel copolymer has been synthesized by the radical polymerization of poly (ethylene oxide) methacrylate, stearyl methacrylate, hydroxypropyl methacrylate and trimethoxysilylpropyl methacrylate. The polymer was characterized by Fourier transform infrared spectroscopy, proton nuclear magnetic resonance (1H-NMR) spectroscopy and gel permeation chromatography. The crosslinkable coating was prepared by dip-coating 5mg/ml solution in tetrahydrofuran onto glass substrate. A stable crosslinked coating was obtained after curing the coating at 70 degrees C for 9 h. Contact angle results indicated the possible reorganization of the surface amphiphilic molecule which interpreted the excellent biocompatibility revealed by the results of the platelet adhesion and plasma recalcification time. Rhodamine S and Cibacron Blue were used as model drugs to prepare drug-containing coating at the same conditions. Drug-releasing curves indicated that the mechanism of the release is approximately Fickian release.

Blood Coagulation↗

Plasma-treated nanostructured TiO(2) surface supporting biomimetic growth of apatite.

Although some types of TiO(2) powders and gel-derived films can exhibit bioactivity, plasma-sprayed TiO(2) coatings are always bioinert, thereby hampering wider applications in bone implants. We have successfully produced a bioactive nanostructured TiO(2) surface with grain size smaller than 50 nm using nanoparticle plasma spraying followed by hydrogen plasma immersion ion implantation (PIII). The hydrogen PIII nano-TiO(2) coating can induce bone-like apatite formation on its surface after immersion in a simulated body fluid. In contrast, apatite cannot form on either the as-sprayed TiO(2) surfaces (both <50 nm grain size and >50 nm grain size) or hydrogen-implanted TiO(2) with grain size larger than 50 nm. Hence, both a hydrogenated surface that gives rise to negatively charged functional groups on the surface and small grain size (<50 nm) that enhances surface adsorption are crucial to the growth of apatite. Introduction of surface bioactivity to plasma-sprayed TiO(2) coatings, which are generally recognized to have excellent biocompatibility and corrosion resistance as well as high bonding to titanium alloys, makes them more superior than many current biomedical coatings.

Apatites↗

Host-bacteria interactions in foreign body infections.

Persistent staphylococcal infections are a major medical problem, especially when they occur on implanted materials or intravascular catheters. This review describes some of the recently discovered molecular mechanisms of Staphylococcus aureus attachment to host proteins coating biomedical implants. These interactions involve specific surface proteins, called bacterial adhesins, that recognize specific domains of host proteins deposited on indwelling devices, such as fibronectin, fibrinogen, or fibrin. Elucidation of molecular mechanisms of S aureus adhesion to the different host proteins may lead to the development of specific inhibitors blocking attachment of S aureus, which may decrease the risk of bacterial colonization of indwelling devices.

Adhesins, Bacterial↗

Fluorapatite-mullite glass sputter coated Ti6Al4V for biomedical applications.

A number of bioactive ceramics have been researched since the development of Bioglass in the 1970's. Fluorapatite mullite has been developed from the dental glass-ceramics used for more general hard tissue replacement. Being brittle in nature, glass-ceramics are currently used mainly as coatings. This paper shows that fluorapatite glass LG112 can be used as a sputtered glass coating on roughened surfaces of Ti6Al4V for possible future use for medical implants. An AFM was used to measure the roughness of the surface before and after coating to determine the change in the topography due to the coating process as this greatly affects cell attachment. The sputter coating partially filled in the artificially roughened surface, changing the prepared topography. Osteoblasts have been successfully grown on the surface of these coatings, showing biocompatibility with bone tissue and therefore potential use in hard tissue repair.

Alloys↗

Room-temperature preparation and characterization of poly (ethylene glycol)-coated silica nanoparticles for biomedical applications.

Monodisperse, spherical, polyethylene glycol (PEG)-coated silica nanoparticles have been prepared at room temperature and characterized for the purpose of biomedical applications. The particles were synthesized by the hydrolysis of tetramethyl orthosilicate (TMOS) in alcohol media under catalysis by ammonia, and their size can range from about 50-350 nm in diameter. We studied the particle size and size distribution using a scanning electron microscope (SEM) and an asymmetric field-flow fractionation (AFFF) multiangle static light-scattering instrument. The chemical and/or physical binding of PEG to the silica nanoparticles was studied by infrared spectroscopy, and the weight percentage of PEG attached to the particles was quantified. The PEG-coated silica nanoparticles showed enhanced colloidal stability when redispersed into aqueous solutions from the dried state as a result of the steric stabilization function of the PEG polymer grafted on the surface of particles. A nonspecific protein-binding test was also carried out to show that the PEG coating can help reduce the protein adsorption onto the surface of the particles, relating to the biocompatibility of these PEG-coated particles. Also, the inclusion of magnetic nanoparticles into the silica particles was shown as an example of the possible applications of PEG-coated silica particles. These silica nanoparticles, as a matrix for encapsulation of certain reagents, have potential for applications to in vivo diagnosis, analysis, and measurements inside intact biologic systems.

Biocompatible Materials↗

Toxicity of particulate silicon carbide for macrophages, fibroblasts and osteoblast-like cells in vitro.

There is widespread interest in the use of interfacial layers in the preparation of diamond and diamond-like carbon (DLC) coatings. These DLC coatings deposited onto metal substrates with a silicon carbide (SiC) interfacial layer exhibit improved adhesion and show promise as wear-retardant coatings for biomedical implants. Although the DLC coatings show excellent biocompatibility in vitro, they may be susceptible to damage within the biological environment, leading to exposure of the interfacial silicon carbide. We have investigated the effects of two forms of silicon carbide (alpha-SiC and beta-SiC) on macrophages, fibroblasts and bone cells in vitro. Both alpha- and beta-SiC are well-tolerated by cells at concentrations of up to 0.1 mg/ml but cause severe cytotoxicity at a concentration of 1 mg/ml. If SiC is to be used as an interfacial layer on biomedical implants, the quality of the DLC coating must be optimised to minimise the risk of film breakdown.

Adhesiveness↗

Adhesion of new bioactive glass coating.

A valuable alternative to the existing biomedical implant coatings is a bioactive glass (BAG) coating that is produced by reactive plasma spraying. A mechanical performance requirement that is of the utmost importance is the adhesion strength of the coating. Considering the application as dental implant, a new adhesion test (shear test), which was close to the service conditions, was designed. A Ti6Al4V rod (3 mm) with a sprayed BAG coating of 50 microm was glued with an epoxy glue to a hollow cylindrical counterpart and was used as such in the tensile machine. This test was evaluated by finite element analysis (FEA). Preliminary experiments showed that a conversion from shear to tensile adhesion strength is possible by using the Von Mises criterion (sigma = 3(1/2)tau), indicating that thin coatings of brittle materials can behave as a ductile material. The new coating technique was proved to produce a high quality coating with an adhesion strength of 40.1 +/- 4.8 MPa in shear and 69.4 +/- 8.4 MPa in tension. The FEA revealed that no one homogeneously distributed shear stress is present but several nonhomogeneously distributed stress components (shear and tensile) are present in the coating. This analysis indicated that real service conditions are much more complicated than standard adhesion tests.

Adhesives↗

Engineering analysis of diamond-like carbon coated polymeric materials for biomedical applications.

Diamond-like carbon (DLC) films have received much attention recently owing to their properties, which are similar to diamond: hardness, thermal conductivity, corrosion resistance against chemicals, abrasion resistance, good biocompatibility, and uniform flat surface. Furthermore, DLC films can be deposited easily on many substrates for wide area coat at room temperature. DLC films were developed for applications as biomedical materials in blood contacting-devices (e.g., rotary blood pump) and showed good biocompatibility for these applications. In this study, we investigated the surface roughness by Atomic Force Microscopy (AFM) and Hi-vision camera, SEM for surface imaging. The DLC films were produced by radio frequency glow discharge plasma decomposed of hydrocarbon gas at room temperature and low pressure (53 Pa) on several kinds of polycarbonate substrates. For the evaluation of the relation between deposition rate and platelet adhesion that we investigated in a previous study, DLC films were deposited at the same methane pressure for several deposition times, and film thickness was investigated. In addition, the deposition rate of DLC films on polymeric substrates is similar to the deposition rate of those deposited on Si substrates. There were no significant differences in substrates' surface roughness that were coated by DLC films in different deposition rates (16-40 nm). The surface energy and the contact angle of the DLC films were investigated. The chemical bond of DLC films also was evaluated. The evaluation of surface properties by many methods and measurements and the relationship between the platelet adhesion and film thickness is discussed. Finally, the presented DLC films appear to be promising candidates for biomedical applications and merit investigation.

Anticoagulants↗

In vitro and in vivo investigations into the biocompatibility of diamond-like carbon (DLC) coatings for orthopedic applications.

Diamond-like carbon (DLC) shows great promise as a durable, wear- and corrosion-resistant coating for biomedical implants. The effects of DLC coatings on the musculoskeletal system have not been investigated in detail. In this study, DLC coatings were deposited on polystyrene 24-well tissue culture plates by fast-atom bombardment from a hexane precursor. Two osteoblast-like cell lines were cultured on uncoated and DLC-coated plates for periods of up to 72 h. The effects of DLC coatings on cellular metabolism were investigated by measuring the production of three osteoblast-specific marker proteins: alkaline phosphatase, osteocalcin, and type I collagen. There was no evidence that the presence of the DLC coating had any adverse effect on any of the parameters measured in this study. In a second series of experiments, DLC-coated cobalt-chromium cylinders were implanted in intramuscular locations in rats and in transcortical sites in sheep. Histologic analysis of specimens retrieved 90 days after surgery showed that the DLC-coated specimens were well tolerated in both sites. These data indicate that DLC coatings are biocompatible in vitro and in vivo, and further investigations into their long-term biological and tribological performance are now warranted.

Alkaline Phosphatase↗