Search PubMedSearch

SEARCH · Search PubMed

Results for “Semen detection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

268 records · Page 2Linked to original sources

Spatially confined electrochemical strategy with DNA-assembled nanogaps for SNP detection.

Accurate detection of low-abundance single nucleotide polymorphisms (SNPs) against a large excess of homologous wild-type sequences requires both selective molecular recognition and effective transduction of small sequence differences into measurable signals. Here, we report a spatially confined electrochemical strategy that couples sequence-selective recognition with size-dependent mass-transport gating. DNA-hybridization-driven self-assembly of gold nanoparticles (AuNPs) forms a three-dimensional self-assembled electrode (3D-SAE) with a DNA-defined interparticle architecture. Competitive probes (SP/WP) convert single-base recognition into distinct molecular-size states: the SNP-associated pathway preferentially triggers a hybridization chain reaction (HCR), generating bulky AuNP-anchored HCR/methylene blue complexes (Au@HCR/MB) with reduced electrochemical accessibility through the porous 3D-SAE, whereas the wild-type pathway does not trigger HCR and maintains a high-current response from more readily accessible MB-containing species. Thus, sequence recognition is translated into a molecular-size difference and subsequently into an electrochemical signal through differential mass transport. Under buffer conditions, the platform achieved a statistically estimated detection limit of ∼0.47 fM and a quantitative range of 1 fM-100 pM. It discriminated a 0.1% mutant abundance in a fragmented genomic-DNA background. The downstream signal-transduction chemistry is enzyme-free and isothermal. This work establishes a mechanistical recognition-size-conversion-mass-transport-gating architecture for electrochemical nucleic acid analysis.

Polymorphism, Single Nucleotide

Machine learning-assisted Mn-N-C nanozyme colorimetric sensor array for trace-level detection of biogenic amines in meat.

Accurate detection of biogenic amines (BAs) in meat remains challenging due to their high structural similarity and co-occurrence. Herein, an Mn-N-C nanozyme was synthesized via a metal-organic framework confined pyrolysis strategy, possessing excellent oxidase (OXD)- and peroxidase (POD)-like activities. The dual enzyme-like activity showed Km values of 0.1584 mM (OXD) and 0.1498 mM (POD), respectively, in detection system. Leveraging these properties, a colorimetric sensor array was constructed, enabling the detection of four representative BAs within a concentration range of 2-10 ppm with 100% classification accuracy. In addition, a concentration independent recognition model based on an artificial neural network was developed to address signal nonlinearity interference in meat. The integrated system achieved accurate trace-level identification of BAs in perishable fish, pork, and chicken, demonstrating its applicability for early-stage BAs monitoring and quality deterioration warning during storage and transportation.

Biogenic Amines

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236 nm, emission 340 nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125 × 4.0 mm, 5 μm) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8 mL/min. The method showed excellent linearity (r > 0.999) over 0.01-1.0 μg/mL for IMQ and 0.1-2.0 μg/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001 μg/mL for IMQ and 0.004 μg/mL for TBF, with quantification limits of 0.02 μg/mL and 0.16 μg/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

A Meta-learning-driven strategy for adulteration detection in sweet potato starch and vermicelli using Raman spectroscopy.

To address the widespread adulteration of sweet potato starch and its vermicelli with cheaper starches and overcome conventional supervised learning's dependency on large labeled datasets, this study developed a few-shot discrimination method integrating Raman spectroscopy with meta-learning. We constructed a meta-learning framework using cassava- and wheat-adulterated sweet potato starch as the source domain for training, with potato-adulterated sweet potato starch and cassava-adulterated sweet potato vermicelli as two target domains for testing. Raman spectra showed high consistency between sweet potato vermicelli and its raw starch, laying the foundation for cross-domain detection. Testing yielded comprehensive classification accuracies of 95.33% and 98.00% for the two target domains, significantly outperforming SVM, RF, and CNN (max. 85.24%). This approach effectively identifies subtle starch variety differences in complex adulteration, providing novel food quality inspection solutions and verifying the feasibility of raw material-to-finished product cross-domain detection.

Ipomoea batatas

Interfacial engineering of cobalt tungstate-halloysite nanotube nanocomposite for electrochemical detection of synthetic vanillin in food matrices.

In processed foods and medicine, synthetic vanillin is widely used, although excessive intake poses toxicological risks. Due to the rising usage of synthetic vanillin in food products and associated health hazards, quick, sensitive, and reliable analytical methods are needed to precisely measure vanillin in complex food matrices. This work introduces a CoWO4@F-HNT/GCE nanocomposite as an efficient electrocatalytic modifier for glassy carbon electrodes aimed at trace-level synthetic vanillin detection. Structural and microscopic analyses confirmed phase-pure monoclinic CoWO4, preservation of the tubular aluminosilicate framework, and homogeneous nanoparticle anchoring on F-HNT. Differential pulse voltammetry provided a broad linear range from 0.01 to 372.14 μM and a low detection limit of 4.3 nM, together with excellent selectivity against common interferents, good cycling stability, and high inter-electrode reproducibility. These characteristics position the CoWO4@F-HNT-modified electrode as a cost-effective and reliable platform for on-site quality control of synthetic vanillin in complex food matrices.

Benzaldehydes

Influence of soil types with different soil-forming process on the qualitative and quantitative detection of microplastics by near-infrared spectroscopy.

Microplastics (MPs) have become a pressing global environmental threat, with soils-acting as sinks for MPs from multiple sources-gaining increasing attention. Near-infrared (NIR) spectroscopy offers a promising tool for MPs detection due to its rapid, non-destructive, and field-applicable features. Although previous studies have focused on the effects of individual soil components on the NIR detection performance of MPs, there is still a lack of systematic research on how the complex background-formed by the coupling of multiple physicochemical properties in natural soils-affects detection performance. This study focuses on soil types with different soil-forming processes, selected five representative agricultural soils to systematically evaluate how the combinations of physicochemical properties they represented affect the performance of NIR-based qualitative and quantitative analysis of MPs in soils. The results demonstrated that soil type significantly affected both the spectral response and detection performance of MPs. Brown Pedocals and Brown Earth exhibited clearer characteristic absorption and stronger linear responses, achieving higher identification accuracy under low (<1.5 %) or zero MPs concentrations and the best quantitative performance (R2 &#x2265; 0.988, prediction set root mean square error (RMSEP) &#x2264; 0.110 %). In contrast, Phaeozem and Red Soil were more prone to misclassification at low concentrations, while Fluvo-aquic Soil showed the poorest quantitative performance. This study is the first to reveal, at a holistic level, the critical constraints posed by natural soil complexity on the NIR detection of MPs, offering targeted empirical evidence to support the application of NIR technology in real-world soil environments.

Soil

Portable metagenomics for preventive surveillance and outbreak control in livestock and poultry: Pathogen detection, resistome profiling, and antimicrobial stewardship.

Conventional diagnostics for livestock and poultry outbreaks commonly rely on culture or targeted PCR panels, which may be too slow or too narrow to guide early control decisions. Portable metagenomics, particularly real-time nanopore sequencing, offers a route to broad pathogen detection, antimicrobial-resistance gene profiling, and outbreak investigation within an integrated workflow. This implementation-focused review evaluates how near-point-of-care metagenomics may support preventive veterinary medicine through earlier detection, surveillance, cohorting, biosecurity decisions, and antimicrobial stewardship. We synthesize sample-to-answer workflows for enteric and respiratory disease in food-producing animals, including sampling, nucleic-acid extraction, host depletion or target enrichment, library preparation, sequencing, bioinformatics, quality control, and interpretation. Applications in calf diarrhea, bovine respiratory disease, poultry outbreaks, mastitis, and resistome monitoring are considered alongside the central limitation that detection alone does not establish causation. Pathogen and resistance-gene signals must therefore be interpreted with clinical signs, lesions, epidemiology, controls, and confirmatory testing. We also propose a minimum reporting checklist, intended as a practical framework rather than a validated consensus standard. Portable metagenomics is not a replacement for conventional diagnostics, but appropriately validated workflows can reduce uncertainty during time-sensitive outbreaks and support more judicious antimicrobial use.

Animals

Recent advances in electrode materials for electrochemical detection of zearalenone.

Zearalenone (ZEN) is an estrogenic mycotoxin commonly found in cereals, animal feed, and processed foods, making it an important concern for food safety and public health. Conventional chromatographic and immunological methods can detect ZEN; however, they often require expensive instruments, lengthy sample preparation, and skilled personnel, which restrict their use for rapid and on-site testing. Electrochemical sensors have attracted enormous interest of the scientific community because of their high sensitivity, rapid response, low cost, miniaturization potential, and compatibility with portable systems. The analytical performance of the electrochemical sensors is strongly influenced by electrode materials, morphology, conductivity, porosity, surface functionality, and the efficiency of bioreceptor immobilization. Despite several reviews on mycotoxin detection, a systematic assessment connecting electrode-material design, modification strategies, sensing mechanisms, and electroanalytical performance specifically for ZEN sensing remain limited. This review critically evaluates recent advances in metal oxides, carbon-based materials, metal-organic- and covalent organic frameworks, MXenes, polymers, and hybrid composites for electrochemical ZEN detection. Particular attention has been given to their roles in electron transfer, analyte enrichment, selectivity, and real-sample analysis. The review also compares the major limitations of current sensing systems, including complex fabrication, matrix interference, insufficient long-term stability, poor inter-electrode reproducibility, and limited scalability. Finally, future directions for developing robust, cost-effective, portable, and commercially viable ZEN sensors are discussed.

Journal Article

Selective and sensitive colorimetric sensing of carbosulfan based on BiO2-x/Bi2O2.75 nanosheets with excellent haloperoxidase-like activity.

The development of colorimetric methods based on directly inhibiting nanozyme activity for pesticide detection has attracted considerable attention. In this study, we report a novel colorimetric sensing strategy utilizing BiO2-x/Bi2O2.75 nanosheets (BiO2-x/Bi2O2.75 NSs) with haloperoxidase (HPO)-like activity for the rapid and sensitive detection of carbosulfan (CBS) in foods. Oxygen-vacancy-rich BiO2-x/Bi2O2.75 NSs with HPO-like activity were rationally constructed. Kinetic studies revealed a remarkable Michaelis-Menten constant (Km) of 0.014&#xa0;mM for I-, indicating a higher affinity for iodide ions than other reported HPO-like nanozymes, as evidenced by its lower Km. Under acidic conditions, CBS tends to be hydrolyzed to produce reductive sulfide species, which directly inhibit the iodoperoxidase-like activity of BiO2-x/Bi2O2.75 NSs, enabling selective detection with a limit of detection (LOD) of 0.18&#xa0;&#x3bc;g/mL and a linear range of 0.20-100&#xa0;&#x3bc;g/mL. When the concentration of interfering pesticides and substances was 5 times that of CBS, the sensor remained unaffected, exhibiting excellent stability and specificity. This work contributes to the detection of CBS in complex food matrices, bridging the application gap of HPO-like nanozymes in pesticide detection and providing a promising method for food safety detection.

Colorimetry

A point-of-use SERS assay for rapid detecting difenoconazole and flusilazole residues in fruit juices using Au/COF substrate.

We developed a ready-to-use surface-enhanced Raman scattering (SERS) sensor for rapid, pretreatment-free detection of difenoconazole (DIF) and flusilazole (FLU) in peach and lychee juices. The substrate combines Au nanoparticles (AuNPs) with covalent organic frameworks (COF) and is implemented on a portable 25-well plate, enabling in situ testing. Juices can be directly applied to the SERS-active Au/COF composite, allowing simultaneous adsorption and signal generation. The correlation between SERS intensity and logarithmic concentration yielded R-values between 0.925 and 0.986, meeting the monitoring needs of non-laboratory scenarios. The entire workflow completes within 12&#xa0;min, offering a faster alternative to conventional methods while maintaining high sensitivity and reproducibility. Detection limits reach 0.96-1.22&#xa0;ppb for DIF and FLU, both of which are below the regulatory maximum residue limits. Distinct SERS fingerprints enable reliable discrimination of mixed residues across juice matrices, supporting rapid on-site monitoring and cost-effective pesticide surveillance.

Triazoles

A homogeneous immunoassay based on AlphaLICA technology for detecting florfenicol residues in animal-derived foods.

Florfenicol (FF), a broad-spectrum amide antibiotic widely used in livestock, poultry, and aquaculture, poses potential threats to food safety and public health due to its residual accumulation. In this study, a novel homogeneous immunoassay based on Amplified Luminescent Proximity Homogeneous Assay (AlphaLICA) technology was developed for the first time for rapid screening of FF residues in milk and egg matrices. By covalently immobilizing the FF-BSA conjugate and goat anti-mouse IgG onto luminescent and photosensitive microspheres, respectively, the method achieved wash-free, homogeneous quantitative detection through a competitive immunoreaction. Under optimized conditions, the assay exhibited a linear range of 0.2-16.2 ng mL-1, with a limit of detection of 9.7 pg mL-1 and a limit of quantification of 183 pg mL-1. The intra- and inter-batch coefficients of variation ranged from 3.08% to 5.70% and 2.44% to 7.09%, respectively. Spike recovery rates in milk and egg matrices ranged from 93.18% to 107.17% (RSD &#x2264; 5.57%). Cross-reactivity with 11 other common antibiotics, including chloramphenicol and thiamphenicol, was below 0.1%, demonstrating excellent specificity. Comparative analysis with a commercial ELISA kit showed high consistency (r2 = 0.9332, p < 0.001). With high sensitivity, strong specificity, simple operation, and a detection time of only 10 min, this method provides a reliable technical platform for high-throughput, rapid monitoring of FF residues in milk and egg matrices.

Journal Article

Emergence of a Novel, Phenotypically Difficult-to-Detect Vancomycin-Resistant Enterococcus faecium Clone (ST117/CT7799).

A significant increase of vancomycin-resistant Enterococcus faecium (VREfm) infections was observed in South-Eastern Austria since 2024. The prolonged outbreak is caused by a novel vanB-VREfm clone (ST117/CT7799, "VREfmstyr"). This study characterizes the atypical difficult-to-detect resistance phenotype and assesses the genomic relatedness of the isolates. Patient and outbreak characteristics were investigated including whole genome sequencing of the isolates. Sensitivity of broth microdilution (BMD), gradient tests (GT), disk diffusion (DD), and automated susceptibility testing (VITEK2) was compared. The performance of commercial screening media was evaluated. From sporadic detections in early 2024 case numbers began to rise during the year. In 30/31 (97%) of all cases, intra-hospital transmission was considered likely and an association with invasive procedures was identified in most cases. Core genome multilocus sequence typing revealed only six allelic differences between VREfmstyr isolates collected in a 12-month period, all belonging to the E. faecium ST117/CT7799 lineage. BMD detected vancomycin resistance (MIC&#x2009;>&#x2009;4&#x2009;mg/L) in no more than 16/31 (52%) of isolates after 24&#x2009;h incubation, while GT and DD misclassified all isolates. Only prolonged incubation improved the performance of these assays. VITEK2 analysis, however, correctly classified all 31 isolates. Of four commercially available VRE-screening agars, only one was capable of detecting VREfmstyr after 24&#x2009;h incubation. The emergence and clonal dissemination of VREfm ST117/CT7799 reveals a serious diagnostic gap as commonly used diagnostic algorithms fail to reliably detect this resistance phenotype. Our findings should help to further evaluate the true geographical distribution and clinical significance of this novel VREfm clone.

Enterococcus faecium

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90&#xa0;min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

Artificial intelligence for dental caries detection: An umbrella review.

Artificial intelligence (AI) has been proposed as a tool to improve dental caries detection across imaging modalities; however, its clinical value remains uncertain. This umbrella review aimed to synthesize and critically appraise systematic reviews evaluating AI for caries detection and diagnosis. An umbrella review was conducted following PRIOR guidance (PROSPERO CRD420261340728). Searches were performed in MEDLINE, Embase, Scopus, Web of Science, and Google Scholar up to 15 March 2026. Methodological quality was assessed using AMSTAR 2, and overlap of primary studies was quantified using the corrected covered area (CCA). Seventeen systematic reviews were included, of which five reported diagnostic test accuracy meta-analyses using bivariate or HSROC models. Across these meta-analyses, pooled sensitivity ranged from 0.76 to 0.94 and specificity from 0.85 to 0.91. Most systems were based on deep learning models applied to bitewing radiographs and intraoral photographs. However, substantial heterogeneity was observed in imaging modalities, lesion thresholds, analytical tasks, and evaluation metrics. In addition, a high degree of overlap across reviews and recurrent methodological limitations, including reliance on retrospective datasets, limited external validation, and inconsistent reporting, substantially weaken the reliability of the evidence. Although AI models demonstrate high diagnostic performance under experimental conditions, current evidence does not support their use as stand-alone diagnostic tools. Their clinical applicability remains limited, and implementation should be restricted to decision-support contexts until robust prospective validation demonstrates meaningful impact on clinical decision-making and patient outcomes.

Dental Caries

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine&#x2011;hydrogen peroxide (TMB-H&#x2082;O&#x2082;) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82&#xa0;CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques