Search PubMedSearch

SEARCH · Search PubMed

Results for “Holographic visualization”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

114 records · Page 2Linked to original sources

Effectiveness of STK Spray® for semen stain localization on solid surfaces: A specificity and sensitivity study.

Semen identification is a crucial step in sexual assault cases. The aim of this study was to assess STK Spray®, a presumptive test for semen, under controlled conditions including, simulated crime scene stains detection. Easy to use, it can be sprayed directly onto different surfaces and visualized under UV light. Several tests were performed on five different substrates (ceramic tile, drywall, metal, wood, and faux leather). The spray was able to enhance semen fluorescence, especially in diluted samples, with characteristic "globular" spots. Although it showed good specificity, false positives could be obtained with 10% bleach. The fluorescence signals were quantified using ImageJ™ and showed a statistically significant substrate-dependent variability. Mixture analysis indicated that saliva did not interfere with detection of semen, while urine partially suppressed the signal and blood markedly affected its interpretation. Simulation tests with UV lamp comparisons confirmed the importance of choosing the right detection method and the utility of this presumptive test in combination with additional immunochromatographic tests. A preliminary signal retention test showed stable fluorescence for up to two years when stains were stored appropriately. Finally, complete DNA profiles (100% of alleles) were obtained from all samples (n = 24) after exposure to the reagent and UV light. Because of its ability to enhance semen signal, especially on specific surfaces, and its rapidity of use and detection, STK Spray® may represent a useful aid in the preliminary screening phase.

Humans

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Effectiveness of Topical Huzhang Sanhuang with Standard Nursing for Chemotherapy-Induced Phlebitis: Randomized Controlled Study.

Chemotherapy-induced phlebitis (CIP) is a common complication of peripheral intravenous chemotherapy that can cause pain, local inflammation, treatment interruption, and diminished quality of life. This randomized controlled trial evaluated the efficacy and safety of the topical Huzhang Sanhuang (HZSH) formula, combined with standard nursing care, in managing CIP. Ninety-four hospitalized patients with CIP (grade I or higher) were randomly assigned in a 1:1 ratio to receive either topical HZSH formula plus standard nursing care (experimental group, n = 47) or 50% magnesium sulfate wet dressing plus standard nursing care (control group, n = 47) for 14 days. Prespecified outcomes included phlebitis grade, visual analog scale (VAS) pain score, high-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6), symptom resolution time, and safety indicators. By Day 14, patients in the experimental group demonstrated significantly greater improvement in phlebitis severity than those in the control group (risk ratio for grade &#x2265; II, 0.42; 95% confidence interval, 0.20-0.87; P = 0.012). The experimental group also showed significantly larger reductions in VAS pain scores, hs-CRP levels, and IL-6 concentrations (all P < 0.01). Kaplan-Meier analysis further demonstrated faster resolution of multiple local symptoms in the experimental group. Treatment adherence was high in both groups, and no serious adverse events or major safety concerns were observed. These findings indicate that the topical HZSH formula, combined with standard nursing care, is a safe and effective integrative nursing intervention that accelerates clinical recovery, alleviates local symptoms, and reduces the inflammatory burden in patients with chemotherapy-induced phlebitis.

Humans

Human-Centered Workspace Optimization: A 2 &#xd7; 2 Factorial Study of Adjustable Furniture and Indoor Environmental Quality.

Small workspaces function as integrated systems, yet ergonomic furniture and indoor environmental conditions are usually evaluated separately. A six-site, assessor-blinded, randomized 2 &#xd7; 2 factorial controlled study was conducted of two multicomponent packages-adjustable furniture and optimized indoor environmental quality (IEQ)-among 240 office workers for four weeks. Each group included 60 participants. Overall comfort in week 4 was highest for both packages (5.62 &#xb1; 0.53 versus 3.99 &#xb1; 0.60 with fixed furniture and basic IEQ). In a site-adjusted factorial model with HC3 robust standard errors, the adjustable-furniture effect was 0.86 points (95% confidence interval [CI], 0.62-1.09), the optimized-IEQ effect was 0.34 points (95% CI, 0.12-0.55), and their interaction was 0.44 points (95% CI, 0.14-0.74). Adjustable furniture improved postural comfort and reduced neck and lower back discomfort; optimized IEQ improved environmental comfort; both packages improved perceived productivity, satisfaction, and fatigue. The task-accuracy interaction did not remain significant after false-discovery-rate adjustment, and exploratory mediation and spline analyses did not support indirect or nonlinear effects. These results support coordinated ergonomic and environmental implementation while preserving distinct outcome pathways.

Interior Design and Furnishings

Screening for neurofibromatosis type 1-related optic pathway gliomas: a systematic review.

BACKGROUND: Neurofibromatosis-type 1 (NF1) is a genetic disorder characterized by developing optic pathway gliomas (OPGs) in 15%-20% of patients with higher estimates where consanguinity is prevalent. Clinically, NF1-OPG might be unpredictable with the risk of OPG progression and visual impairment. The optimal time for screening is controversial. We aim to identify the mean/median age at diagnosis of NF1-OPG and its clinical spectrum. METHODS: A systematic review of PubMed, Web of Science, and Embase databases was conducted for English-language publications from January 1993 to October 2025, exploring the visual screening of OPGs in NF1 patients, following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and registered in the Prospective Register of Systematic Reviews (PROSPERO ID: CRD420251036244). Inclusion criteria focused on studies reporting the age at OPG diagnosis and visual manifestations in NF1 patients. Data were extracted on demographics, age at NF1 and OPG diagnosis, tumour location (using the Dodge classification), and presenting symptoms. Sixteen studies met the inclusion criteria. RESULTS: Among 4 739 NF1 patients, 818 had OPGs, with prevalence ranging from 4.2% to 46.7%. The age at NF1 diagnosis ranged from 0 to 132 months (mean: 18-38 months), and at OPG diagnosis from 0-240 months (median: 29-58 months). Approximately 58.4% of OPGs were asymptomatic, and 25% were above the age of 5 years. Among symptomatic patients, the most frequent presentations included decreased visual acuity (62%), abnormal optic disc (45%), proptosis (20%), strabismus (12%), and visual field defects (7%). CONCLUSIONS: NF1-related OPGs typically present early within 6 years of age. Early ophthalmologic and/or radiologic screening at the time of NF1 diagnosis enhances the detection of silent OPGs.

Humans

An exploratory analysis of decision-making in population affinity estimation among forensic anthropology practitioners in the United States.

Population affinity estimation in forensic anthropology often involves the integration of multiple pieces of information, including visual (nonmetric) and metric data. This study examines how practitioners interpret and synthesize visual and metric information and their decision-making processes. A Qualtrics survey was developed using two cases: Case 1 presented clear nonmetric signal but ambiguous metric signal, while Case 2 showed more ambiguous nonmetric signal but clear metric signal. Practitioners were asked to estimate population affinity based on visual assessment, Fordisc data, and provide a final, integrated assessment. A total of 22 valid survey responses were received, with the majority of survey respondents reporting more than 10&#xa0;years of forensic anthropology experience and holding a PhD degree. Results showed that there is substantial variability in Fordisc use and interpretation. Across both cases, participants synthesized conflicting visual and metric information, converged toward the stronger signal, and came to more consistent final estimates relative to the more ambiguous input. These findings highlight variability in practitioner decision-making but suggest that integration of nonmetric and metric information in population affinity estimation can moderate decision-making uncertainty. The results have implications for forensic anthropology education, training, and proficiency testing.

Humans

Posterior Segment Risk Factors for Penetrating Keratoplasty Failure.

PURPOSE: To analyze the relationship between intraoperative and postpenetrating keratoplasty (PK) posterior segment variables and PK graft survival. DESIGN: Retrospective clinical cohort study. SUBJECTS: Patients undergoing PK between May 1, 2007 and September 1, 2018 at a single tertiary center. METHODS: Chart review for PKs performed was conducted, and the first PK completed at the institution for each patient was included for analysis. Data collected included demographics, medical and ocular history, preoperative and intraoperative findings, and intraoperative and postoperative posterior segment factors (pars plana vitrectomy [PPV], endolaser, retinal detachment [RD], and vitreous hemorrhage [VH]). After univariable analysis, variables were selected for multivariable Cox regression analysis. MAIN OUTCOME MEASURE: Graft failure, defined as irreversible and visually significant corneal edema, haze, or scarring. RESULTS: Eight hundred and thirty-five eyes of 835 patients were included. Mean age was 57.1 &#xb1; 22.0 (range: 0-100) years, and mean time from PK to final follow-up or graft failure was 3.2 &#xb1; 2.9 (range: 0.01-16.1) years. Graft failure occurred in 35.0% of cases with a mean onset of 1.9 &#xb1; 2.0 (range: 0.04-11.4) years after PK. After multivariable analysis, 9 variables had significant associations with failure. Two posterior segment variables were significant: intraoperative VH at the time of PK (hazard ratio [HR] 6.6, 95% confidence interval [CI] 1.6-27.7, P = .010) and silicone oil (SO) tamponade after the PK (HR 3.2, 95% CI 1.4-7.4, P = .007). CONCLUSIONS: Graft failure is a serious complication of PK. VH at the time of the PK and SO tamponade after the PK were associated with graft failure. In complex eyes that are undergoing PK grafts and that may also require posterior segment interventions, these findings may guide patient counseling and discussion of graft prognosis.

Humans

Nonoperative Management is Associated With Similar Long-Term Patient-Reported Outcomes Compared With Surgery for Cervical Radiculopathy: A Systematic Review and Meta-analysis.

STUDY DESIGN: Systematic review and meta-analysis. OBJECTIVE: To compare long-term patient-reported outcomes between surgical and nonoperative management for cervical radiculopathy. SUMMARY OF BACKGROUND DATA: Cervical radiculopathy is a common condition associated with substantial morbidity. While both surgical and nonoperative approaches are effective, it remains unclear which patients benefit most from each strategy and whether earlier operative intervention confers meaningful long-term advantage. MATERIALS AND METHODS: PubMed, Embase, and the Cochrane Library were searched from inception to January 2026 for randomized and observational studies comparing surgical and nonoperative management for cervical radiculopathy. Primary outcomes included visual analog scale (VAS) scores for neck and arm pain, neck disability index (NDI), and overall clinical success. Secondary outcomes included analgesia use and sick leave. Random-effects meta-analyses were performed using restricted maximum likelihood estimation. Risk of bias was assessed using RoB 2 and ROBINS-I, and certainty of evidence using GRADE. RESULTS: Eleven studies comprising 1154 patients (surgical: 522; nonoperative: 632) were included. Surgery was not associated with superior outcomes in VAS for arm pain (MD: -0.67, 95% CI: -1.59 to 0.26, P =0.12), VAS for neck pain (MD: -0.50, 95% CI: -1.38 to 0.38; P =0.19), or NDI (MD: -3.69, 95% CI: -9.63 to 2.25, P =0.16) after 12 months of treatment, nor in overall success (RR: 1.11, 95% CI: 0.93-1.34, P =0.21). No significant differences were observed in analgesia use ( P =0.54) or sick leave ( P =0.48) at last follow-up. Most studies were rated serious risk of bias and overall certainty of evidence was moderate. CONCLUSION: Evidence from this pooled analysis suggests that long-term pain, disability, and functional outcomes are comparable between patients selected for nonoperative management and those selected for surgery. These findings reflect outcomes within selected cohorts and should not be interpreted as evidence of therapeutic equivalence. LEVEL OF EVIDENCE: Level II.

Humans

A Standardized Nursing-Led Protocol Integrated Pain, Sleep, Medication Adherence, and Symptom Management in Postherpetic Neuralgia.

Postherpetic neuralgia (PHN) is a persistent neuropathic pain condition after herpes zoster that frequently coexists with sleep disturbance, medication-related problems, and fluctuating symptoms. This study evaluated whether a standardized nursing-led protocol could improve multidimensional short-term outcomes beyond usual care. In this prospective, parallel-group randomized controlled trial, 128 adults with PHN were allocated 1:1 to usual care or usual care plus an eight-week protocol integrating structured pain assessment, sleep monitoring, medication-adherence support, and rule-based digital symptom monitoring. The primary outcome was the between-group difference in change in Numeric Rating Scale (NRS) pain score from baseline to Week 8. Secondary outcomes included Pittsburgh Sleep Quality Index (PSQI), MMAS-8 medication adherence, symptom burden, pain-related nocturnal awakenings, breakthrough pain, rescue analgesic use, adverse events, rule-based alerts, and nursing satisfaction. Week-8 data were available for 116 participants (57 usual care; 59 protocol). Mean NRS scores decreased from 7.19 &#xb1; 1.08 to 4.82 &#xb1; 1.53 in the usual-care group and from 7.28 &#xb1; 1.05 to 3.24 &#xb1; 1.28 in the protocol group. An NRS reduction of at least 2 points occurred in 49.1% and 76.3% of participants, respectively. The protocol group also showed larger improvements in PSQI, MMAS-8, symptom burden, and nocturnal awakenings, with fewer breakthrough-pain episodes and less rescue-analgesic use. These findings support further evaluation of the standardized nursing-led protocol in preregistered multicenter trials with intention-to-treat analyses and longer follow-up.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

Descemet Stripping Only in Fuchs Endothelial Corneal Dystrophy: Results of a Randomized Clinical Trial of Topical Ripasudil and Directions for Future Innovation.

PURPOSE: To review history of Descemet stripping only (DSO) in Fuchs endothelial corneal dystrophy, describe the results of a clinical trial of topical ripasudil after DSO (K-321-201 study), and discuss future directions. METHODS: A 1-year, phase 2, randomized, placebo-controlled multicenter clinical trial of two doses of K-321 (ripasudil) administered for 12 weeks after DSO surgery in Fuchs endothelial corneal dystrophy was performed. The primary endpoint, central corneal endothelial cell density (ECD) at 12 weeks after surgery, was determined by an independent reading center that was masked to study group assignment. Duration of corneal edema, need for medical or surgical rescue therapy, corneal thickness, and central ECD throughout the entire study period were also examined. Adverse events and exploratory endpoints were collected. RESULTS: Sixty-five subjects were enrolled (21 in the QID group, 22 in the BID, and in the placebo group). Over 95% of subjects completed the trial. The QID group had a higher central ECD 12 weeks after DSO than the placebo group (531 &#xb1; 312 cells/mm2 vs 228 &#xb1; 298 cells/mm2, P = .0065). Corneal edema cleared in 17/21 (81.0%) of the QID group at 12 weeks, compared with 2/22 (9.1%) of the placebo group (P < .0001). Rescue was required in 2/21 (9.5%) subjects in the QID group and 6/22 (27.3%) subjects in the placebo group (P = .0092). Adverse events were mild and did not lead to discontinuation of treatment. CONCLUSIONS: Topical K-321 given QID improves DSO outcomes, as demonstrated by a higher ECD, more rapid resolution of corneal edema, and reduced failure rate. The medication was well-tolerated.

Humans

Second-Generation ELZA-sub400 Protocol: Individualized High-Fluence Cross-Linking for Ultra-Thin Keratoconus Corneas.

PURPOSE: To evaluate the safety and efficacy of a second-generation individualized corneal cross-linking (CXL) protocol (ELZA-sub400) using high-fluence UV-A irradiation in ultrathin ectatic corneas. DESIGN: Retrospective, single-center, consecutive interventional case series. METHODS: Twenty-nine eyes of 24 patients with progressive keratoconus or post-LASIK ectasia and a post-soak intraoperative thinnest stromal thickness <400 &#xb5;m were included. After epithelial removal and riboflavin soaking, continuous UV-A irradiation (365 nm) at 3 or 9 mW/cm&#xb2; was delivered with total fluence titrated up to 10 J/cm&#xb2; based on intraoperative ultrasound pachymetry and a previously published nomogram targeting an uncross-linked stromal margin of approximately 70 &#xb5;m above the endothelium. Outcomes were assessed at baseline and up to 12 months using corrected distance visual acuity (CDVA) and corneal parameters measured using Scheimpflug tomography and anterior segment OCT (AS-OCT) with Placido-based topography. The main outcome measure was the proportion of eyes without progression at 12 months, defined as <1.0 D increase in maximum keratometry (Kmax). Secondary outcomes included changes in CDVA, refraction, Kmax, stromal thickness, demarcation line depth, densitometry, and safety parameters. RESULTS: At 12 months, 22/29 eyes (76%; 95% CI, 57.9%-87.8%) met the nonprogression criterion. Mean change in Kmax was -0.77 &#xb1; 5.10 D (95% CI, -2.71 to 1.17; P = .418). Mean demarcation line-to-anterior stroma distance was 205 &#xb1; 64 &#xb5;m (95% CI, 180.7-229.3), and demarcation line-to-endothelium distance was 64 &#xb5;m (IQR, 49-152). All demarcation lines remained within the stromal layer; 15/29 eyes (51.7%) had a demarcation line located &#x2264;70 &#xb5;m from the endothelium. Median CDVA changed from 0.10 to 0.32 logMAR (P = .142). Minimum stromal thickness showed a median change of -4.0 &#xb5;m (P = .309). No significant change was observed in densitometry, and no eye developed deep stromal haze or endothelial decompensation. CONCLUSIONS: Second-generation ELZA-sub400 CXL halted ectasia progression in 76% of ultrathin corneas at 12 months and was associated with an acceptable short-term safety profile, including stromal-confined demarcation line formation and no observed endothelial decompensation. The numerical decline in spectacle CDVA observed in this severely affected cohort did not reach statistical significance but is clinically important and warrants confirmation in larger prospective studies.

Humans

[Clinical efficacy and safety of electroacupuncture at the motor area for Parkinson's disease with musculoskeletal pain: a randomized controlled trial].

OBJECTIVE: To observe the clinical efficacy and safety of electroacupuncture (EA) at the motor area for Parkinson's disease (PD) with musculoskeletal pain. METHODS: Fifty-eight patients with PD accompanied by musculoskeletal pain were randomly assigned to an EA group (29 cases, 1 case dropped out) and a sham EA group (29 cases, 1 case dropped out). The EA group was treated with EA at the motor area contralateral to the painful side (for bilateral pain, the left motor area was selected), using disperse-dense wave (2 Hz/20 Hz), with a current intensity of 1-2 mA, and needles were retained for 30 min. The sham EA group was treated with sham EA at non-acupoint area located 5-20 mm posterior to the motor area contralateral to the painful side. The connection mode was the same as that in the EA group, but no electrical current was delivered, and the needles were retained for 30 min. Both groups were treated once daily for 5 consecutive days. Visual analogue scale (VAS) for pain, unified Parkinson's disease rating scale part &#x2162; (UPDRS-&#x2162;), 24-item Hamilton depression rating scale (HAMD-24), Hamilton anxiety rating scale (HAMA), and 39-item Parkinson's disease questionnaire (PDQ-39) scores were evaluated before treatment, immediately after treatment, and at 2 and 4 weeks after treatment completion in the two groups. Safety was also assessed in the two groups. RESULTS: In both groups, VAS scores for pain after treatment and at 2 and 4 weeks after treatment completion were lower than those before treatment (P<0.01, P<0.05). VAS scores for pain in the EA group were lower than those in the sham EA group after treatment and at 2 and 4 weeks after treatment completion (P<0.05). In the EA group, UPDRS-&#x2162;, HAMD-24, HAMA, and PDQ-39 scores after treatment and at 2 and 4 weeks after treatment completion were lower than those before treatment (P<0.05, P<0.01). In the sham EA group, there were no statistically significant differences in UPDRS-&#x2162;, HAMD-24, HAMA, and PDQ-39 scores at any post-treatment time point compared with those before treatment (P>0.05). There were no statistically significant differences in UPDRS-&#x2162;, HAMD-24, HAMA, and PDQ-39 scores between the two groups at any post-treatment time point (P>0.05). No serious adverse events occurred during the trial. CONCLUSION: EA at the motor area could reduce pain intensity in patients with PD accompanied by musculoskeletal pain, and improve pain-related motor symptoms, emotional status, and quality of life, with a favorable safety profile.

Humans

Association Between 24-Hour Blood Pressure and Rates of Retinal Nerve Fiber Layer Progression in Glaucoma: The Vascular Imaging in Glaucoma Study.

PURPOSE: Low systemic blood pressure (BP) has been implicated as a risk factor for glaucoma progression. The purpose of this study was to investigate the association between 24-hour BP and rates of retinal nerve fiber layer (RNFL) loss in eyes with primary open-angle glaucoma. DESIGN: Prospective cohort study. PARTICIPANTS: Seventy-nine eyes from 42 subjects with glaucoma (mean age, 68.5 &#xb1; 7.6 years) enrolled in the Vascular Imaging in Glaucoma Study at the Bascom Palmer Eye Institute. METHODS: Participants underwent 24-hour ambulatory BP monitoring at baseline. Follow-up evaluations were conducted at 4-month intervals and included ophthalmic examination, BP measurement, and peripapillary RNFL thickness measurement with spectral-domain optical coherence tomography. The association between BP and RNFL loss over time was assessed using linear mixed-effects models adjusted for age, sex, race, baseline RNFL thickness, central corneal thickness, and intraocular pressure. MAIN OUTCOME MEASURES: The effect of baseline 24-hour mean arterial pressure (MAP), systolic BP (SBP), and diastolic BP (DBP) on the rate of average RNFL loss over time. RESULTS: Eyes underwent an average of 13 &#xb1; 3 optical coherence tomography exams over 43 &#xb1; 10 months of follow-up. The mean rate of RNFL loss was -0.34 &#xb1; 0.64 &#xb5;m/y (median: -0.32; interquartile range: -0.66 to -0.04 &#xb5;m/y). After adjusting for confounding factors, every 10 mm Hg lower in 24-hour minimum MAP, SBP, and DBP was associated with -0.542 &#xb5;m/y (P < .001), -0.360 &#xb5;m/y (P = .003), and -0.458 &#xb5;m/y (P = .008) faster RNFL loss, respectively. Eyes in the lowest quartile of average 24-hour MAP (81-90 mm Hg) and minimum 24-hour DBP (35-47 mm Hg) experienced significantly faster progression compared to those in the highest quartile, with differences of -0.68 &#xb5;m/y (P = .017) and -0.63 &#xb5;m/y (P = .030), respectively. CONCLUSIONS: Lower systemic BP, especially minimum MAP, SBP, and DBP measured by 24-hour ambulatory BP monitoring, is associated with faster rates of RNFL loss in primary open-angle glaucoma eyes. 24-hour BP monitoring may help predict glaucoma patients at greater risk of progression.

Humans

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans

Continuous Ultrasound-guided Erector Spinae Plane Block Versus Thoracic Paravertebral Block for Postoperative Analgesia in Patients Undergoing Thoracotomy.

OBJECTIVES: To compare postoperative analgesia using continuous ultrasound-guided erector spinae plane block (ESPB) versus thoracic paravertebral block (TPVB), with dynamic visual analog scale (VAS) during coughing as the primary outcome. Secondary outcomes included static VAS (at rest), hemodynamic changes, side effects, total opioid consumption, time of first rescue analgesia, length of hospitalization, anesthesia recovery time, postanesthesia care unit stay, time to first ambulation, and patient satisfaction. METHODS: The study included 40 cases scheduled for elective thoracotomy admitted to the cardiothoracic surgery unit of Menoufia University Hospital. Patients were equally randomized into 2 groups, 20 patients each receiving either ultrasound-guided ESPB or TPVB (control group). Both groups received 20&#xa0;mL of 0.25% bupivacaine as a loading dose followed by continuous infusion of 0.125% bupivacaine at 5&#xa0;mL/h, with patient-controlled boluses of 20&#xa0;mL on demand. RESULTS: Dynamic visual analogue pain scale scores were significantly lower in the ESPB group at 6, 9, 12, and 24 hours ( P =0.008, 0.035, 0.001, 0.006). Morphine consumption was significantly reduced in the ESPB group ( P < 0.001). Hypotension was more frequent in TPVB (40% vs. 10%, P =0.028). No significant differences were observed in hospital stay or patient satisfaction. DISCUSSION: The utilization of continuous ultrasound-guided ESPB demonstrated better postoperative visual analogue pain scale scores and a significant decrease in opioid consumption, with fewer side effects than TPVB.

Humans

Pictographs: feasibility and acceptability of a novel method of newborn identification to reduce wrong-patient errors in the NICU.

Wrong-patient errors cause serious harm in newborns. These errors involve ordering and administering tests, procedures, medications, and breast milk to an unintended patient. Newborns receiving care in neonatal intensive care units (NICUs) are at particularly high risk. Although more distinct newborn naming conventions as recommended by the Joint Commission significantly reduce wrong-patient orders, name similarities among multiple-birth infants and truncation of differentiating information in some electronic health record (EHR) systems contribute to this persistent increased risk. Accordingly, novel newborn identifiers are urgently needed. We propose Pictographs&#xa0;-&#xa0;images that are appealing, recognizable, and appropriate&#xa0;-&#xa0;to serve as visual identifiers for newborns in NICUs. Pictographs are selected by caregivers, uploaded into the EHR, and displayed at bedside. As part of a multicenter randomized controlled trial assessing effectiveness of Pictographs to prevent wrong-patient order errors, we initially evaluated feasibility and acceptability of Pictographs at two study sites. Pictographs as novel visual identifiers for newborns in the NICU were generally well received by caregivers and clinicians, and the vast majority of caregivers selected a Pictograph for their infant(s), which was posted at the bedside and uploaded into the EHR. Ordering clinicians&#xa0;-&#xa0;the primary target of the intervention to prevent wrong-patient errors&#xa0;-&#xa0;recognized the potential for Pictographs to provide a visual cue when placing orders, particularly for multiple-birth infants. Here, we describe the rationale, implementation, framework, feasibility, usefulness, and acceptability of Pictographs among key stakeholders. If found effective for preventing wrong-patient errors, Pictographs could be adopted as a patient safety solution in hospitals worldwide.

Female

Aflibercept With Versus Without Reduced-Fluence Photodynamic Therapy for Polypoidal Choroidal Vasculopathy: Optical Coherence Tomography Angiographic Changes From a Randomized Clinical Trial.

OBJECTIVES: To report the longitudinal optical coherence tomography angiography (OCTA) changes in polypoidal choroidal vasculopathy (PCV) treated with intravitreal aflibercept monotherapy or in combination with reduced-fluence PDT. DESIGN: Image analysis of a double-masked, sham-controlled, randomized clinical trial. SUBJECTS: 55 eyes of 55 treatment-na&#xef;ve participants with symptomatic macular PCV completing 52 weeks of follow-up. METHODS: Participants underwent protocolized, multimodal imaging, including OCT, OCTA, fluorescein angiography, and indocyanine green angiography at baseline, week 12, and week 52. Quantitative OCTA parameters included total lesion area, branching neovascular network (BNN) area, and BNN vessel density (VD). Qualitative features included trunk vessel presence and OCTA signal within the polypoidal lesion (PL). Eyes were categorized by treatment arm and PL closure at week 52. MAIN OUTCOME MEASURES: Longitudinal OCTA changes and predictors of PL closure at week 52. RESULTS: We included 55 eyes (28 combination therapy and 27 monotherapy). Total lesion area decreased at week 12 but returned toward baseline at week 52 (combination: 3.72 &#xb1; 3.01mm2 at baseline, 2.86 &#xb1; 2.50mm2 at week 12, 3.59 &#xb1; 3.26mm2 at week 52; monotherapy: 3.77 &#xb1; 2.23mm2 at baseline, 3.27 &#xb1; 2.36mm2 at week 12, and 3.47 &#xb1; 2.58mm2 at week 52). BNN area decreased at week 12 and remained reduced at week 52 in both treatment arms (combination: 2.29 &#xb1; 2.08 mm2 at baseline, 1.46 &#xb1; 1.36mm2 at week 12, and 1.53 &#xb1; 1.32mm2 at week 52; monotherapy: 2.39 &#xb1; 1.85mm2 at baseline, 1.87 &#xb1; 1.68mm2 at week 12, and 1.82 &#xb1; 1.38mm2 at week 52). BNN VD reduction was greater in the combination arm at week 12 (-10 &#xb1; 15% vs - 3 &#xb1; 12%, P = .02). The proportion of eyes with trunk vessels increased over time in both arms (combination: 35.7% at baseline, 59.3% at week 12, and 67.8% at week 52; monotherapy: 25.9% at baseline, 44.4% at week 12, and 71.4% at week 52). In multivariable analysis, baseline BCVA predicted BCVA change at week 52 (&#x3b2;=-0.96 [-1.21 to -0.72], P < .01), and baseline CST predicted CST change (&#x3b2;=0.93 [0.75 to 1.10], P < .01). Greater reduction in BNN VD at week 12 was independently associated with PL closure at week 52 (OR 0.62 [0.39 to 0.97], P = .03). CONCLUSIONS: Early reduction in BNN vessel density, rather than reduction in lesion size, was associated with subsequent PL closure. OCTA-derived vascular changes may serve as noninvasive biomarkers for predicting treatment response in PCV.

Humans