Search PubMedSearch

SEARCH · Search PubMed

Results for “Device compliance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

107 records · Page 2Linked to original sources

Prothrombin complex concentrate (PCC) vs. non-PCC strategies for warfarin reversal in left ventricular assist device recipients: A systematic review and meta-analysis.

BACKGROUND: Left ventricular assist devices (LVADs) prolong survival in end-stage heart failure, and warfarin thromboprophylaxis is recommended to prevent device thrombosis and thromboembolic complications. When bleeding occurs or emergency surgery is required, rapid anticoagulation reversal is critical. Prothrombin complex concentrate (PCC) provides rapid reversal; however, its risk-benefit profile in LVAD recipients remains unclear. We conducted a systematic review and meta-analysis comparing PCC with non-PCC strategies for warfarin reversal in LVAD recipients. METHODS: MEDLINE, Embase, and Scopus were searched through June 2025 for studies of PCC versus non-PCC strategies for warfarin reversal in LVAD recipients. Two reviewers independently extracted data. Random-effects models were used to pool arm-level estimates and to pool head-to-head comparisons using mean differences or risk ratios (RRs). RESULTS: Eighteen studies involving 779 patients were included. Arm-level pooled estimates for PCC versus non-PCC comparators were 24.0% versus 15.8% for mortality, 16.5% versus 12.1% for thrombotic events, and 3.1 versus 5.7 for FFP units. Arm-level time to INR correction was longer with PCC overall (16.5 versus 13.6 h), driven by one elective cohort, but faster within the ICH subgroup (6.0 versus 13.7 h). In head-to-head comparisons, PCC achieved faster INR correction than non-PCC comparators (mean difference - 7.6 h; p = 0.001) and required fewer FFP units (-2.6 units; p = 0.019), with no significant difference in all-cause mortality (RR 1.14; p = 0.490) or thrombotic events (RR 1.43; p = 0.176). CONCLUSIONS: In head-to-head studies, PCC was associated with faster INR correction and lower FFP requirements than non-PCC strategies, whereas mortality and thrombotic events did not differ significantly. Given the observational evidence, wide confidence intervals, and heterogeneity, equivalent safety cannot be established, and prospective studies are needed to define the relative safety and effectiveness of the two approaches. IMPLICATIONS FOR CLINICAL PRACTICE: PCC-based strategies may be considered for urgent warfarin reversal in LVAD recipients, particularly when rapid INR reduction or avoidance of large-volume plasma transfusion is clinically important. Treatment decisions should account for the indication, bleeding severity, and underlying thrombotic risk. TRIAL REGISTRATION: CRD42024573925.

Humans

The effect of nutrition education interventions on dialysis patients' outcomes: a systematic review and meta-analysis.

BACKGROUND: Non-adherence to dietary and fluid restrictions among dialysis patients is associated with adverse clinical outcomes. Quantifying the effectiveness of nutrition education interventions can inform practice and policy. METHODS: We searched MEDLINE, EMBASE, CINAHL, CENTRAL, PsycINFO, Web of Science, and Scopus up to 15 July 2025, supplemented by trial registries and Google Scholar, with an updated search through 8 April 2026. Eligible studies included randomized and non-randomized trials evaluating nutritional education interventions in adult dialysis populations. Risk of bias was assessed using RoB-2 and ROBINS-I, certainty graded using GRADE, and random-effects meta-analyses conducted alongside subgroup, sensitivity, and meta-regression analyses. Publication bias was assessed with Egger and Begg tests and trim-and-fill where applicable. RESULTS: Forty-four studies comprising 4,106 participants were included. Nutrition education significantly improved knowledge (SMD = 1.09; 95% CI: 0.67-1.51) and health-related quality of life (SMD = 1.43; 95% CI: 0.86-2.00; I² = 0%), and reduced serum potassium (SMD = -0.52; 95% CI: -0.91 to -0.14; I² = 92%) and serum phosphate (SMD = -0.35; 95% CI: -0.56 to -0.15; I² = 81%). Results for albumin, creatinine, sodium, calcium, and BUN were inconsistent and non-significant. Most outcomes were rated low or very low certainty by GRADE, reflecting inconsistency, indirectness, and imprecision. Potential publication bias was identified for certain outcomes. CONCLUSIONS: Nutrition education consistently improves knowledge and quality of life and may modestly reduce serum phosphate and potassium in dialysis patients. High-quality registered trials with standardized outcomes and longer follow-up are needed to establish effectiveness and sustainability. PROSPERO REGISTRATION: CRD420251119567.

Humans

Sacral Neuromodulation in the Management of Refractory Pediatric Lower Urinary Tract Dysfunction.

INTRODUCTION: Sacral neuromodulation is currently used in the pediatric patient population for refractory lower urinary tract dysfunction (LUTD). Evidence, however, is currently limited for institutional experiences of long-term outcomes for sacral neuromodulation in the pediatric patient population. OBJECTIVE: The objective of this study is to perform a retrospective review of a large multi-institutional cohort of pediatric patients that underwent sacral neuromodulation (SNM) for refractory LUTD, focused on rates of symptom improvement, quality of life, and bowel-bladder dysfunction measures following device implantation. Secondary objectives included assessing device complication rates and device removals due to failure or successful resolution of symptoms. METHODS: We performed a retrospective cohort study of pediatric patients at three children's hospitals that underwent SNM device implantation for refractory LUTD. Patients 4-18 years of age who were diagnosed with refractory LUTD and managed at a participating institution with follow-up were included. Outcomes were evaluated at baseline and post-operatively after two-stage device implantation at initial follow-up and annually until device removal or final follow-up. RESULTS: From 2010 to 2022, a total of 205 children underwent SNM procedures at three pediatric hospital centers. 204 patients completed the two-stage procedure for permanent device implantation with a median follow-up of 3.4 years (1.3, 4.9). One hundred seventy-eight patients reported partial (25%) or complete (54%) device response/symptom improvement by final follow-up. Comparison of patient-reported validated questionnaires completed at baseline and by final follow-up visit revealed significant improvement in median Pediatric Quality of Life Inventory (PedsQL) (p&#x2009;=&#x2009;0.004) and Vancouver Nonneurogenic Lower Urinary Tract Dysfunction/Dysfunctional Elimination Syndrome bowel-bladder dysfunction (BBD) scores (p&#x2009;<&#x2009;0.001). Of those with any device complication (n&#x2009;=&#x2009;43;21%), 19 patients required device revision, and 20 required complete device removal. Separately, twenty-eight patients (13%) underwent device removal due to resolution of symptoms or treatment success at a median period of 5 years (4,7). CONCLUSION: SNM use demonstrated a majority of patients reporting at least partial subjective symptom improvement following device implantation across multiple institutions by final follow-up. SNM is a viable treatment option for refractory LUTD in the pediatric patient if willing to undergo an invasive procedure and in which thorough counseling of risks and benefits has occurred.

Humans

Intervention components, training dose, and adherence in exercise-based prevention of hamstring strain injury in football: a systematic review and meta-analysis.

OBJECTIVE: To quantify associations between exercise-based prevention programmes and hamstring strain injury (HSI) risk in football participants, and whether training dose and adherence modify effects. METHODS: Six databases were searched to 1 October 2025. Randomised and cluster-randomised trials comparing HSI prevention programmes with usual practice or warm-up in football participants were included. Random-effects meta-analysis pooled risk ratios (RRs); subgroup analyses and meta-regression assessed effect modification. RESULTS: Fifteen trials (n = 7,465) were analysed. Programmes reduced HSI risk (RR = 0.51, 95% CI 0.36-0.71), with I&#xb2;=57% and a prediction interval crossing the null (0.18-1.40). Based on a control event rate of 7.8%, absolute risk reduction was 3.8% (38 fewer HSIs per 1000 participants; 95% CI 23-50 fewer). Effects were stronger for shorter interventions (1-6 months; RR = 0.43) than longer interventions (7-10 months; RR = 0.77; P for interaction=0.04), and for elite/semi-professional players (RR = 0.38) than amateur players (RR = 0.77; P for interaction = 0.02). Training frequency and weekly volume did not modify effects, whereas adherence did. High adherence (&#x2265;75%) was associated with lower HSI risk (RR = 0.36, 95% CI 0.28-0.48), whereas low adherence (<75%) showed no clear benefit (RR = 0.92, 95% CI 0.68-1.23; P for interaction <0.00001). Each 10% increase in adherence corresponded to an RR multiplier of 0.83 (approximately 17% lower RR). Certainty of evidence was low. CONCLUSION: Exercise-based programmes reduce HSI risk in football when implementation supports sustained adherence. Effects may be stronger in shorter interventions and elite populations, but evidence remains insufficient to differentiate programme types or components.

Humans

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper

A prospective crossover study comparing ICCS-recommended and Palmer-adjusted filling rates in children with spina bifida.

OBJECTIVE: This study aimed to investigate whether the maximal cystometric capacity (MCC) in children with spina bifida (SB) is indeed lower, as predicted by the Palmer formula, and to evaluate the impact of different bladder filling rates on urodynamic parameters. MATERIALS AND METHODS: This prospective, randomized, two-sequence crossover-controlled study included 70 children aged 3-18 years with spina bifida under regular follow-up. In Group 1, the first two bladder fillings were performed at the ICCS-recommended rate, and the third at 75% of that rate (Palmer formula). In Group 2, the sequence was reversed. Urodynamic parameters, including maximal cystometric capacity (MCC), bladder compliance, detrusor activity, filling pressures, and detrusor leak point pressure (DLPP), were analyzed across fillings. RESULTS: Cystometric bladder capacity was lower during fillings performed at the Palmer-adjusted rate compared with those at the ICCS-recommended rate. The proportion of reduced compliance significantly decreased in Group 1 (p = 0.046) but remained unchanged in Group 2. A significant positive correlation was observed between expected bladder capacity (EBC) and measured MCC in both groups (&#x3c1; &#x2248; 0.5-0.6). The highest correlation and agreement were found in Group 1 during the third filling at the Palmer rate (ICC = 0.606). No significant intra- or intergroup differences were observed in detrusor pressure, end-filling pressure, DLPP, or overactive bladder prevalence. CONCLUSION: Bladder filling rate was associated with differences in both cystometric capacity and bladder compliance in children with spina bifida. Fillings performed according to the Palmer formula (approximately 75% of the ICCS-recommended rate) were associated with capacities that more closely approximated age-expected values and with modest differences in bladder compliance. Conversely, faster filling rates did not produce similar benefits. These findings suggest that slower filling strategies may improve measurement consistency and agreement with expected bladder capacity estimates. However, the magnitude and direct clinical impact of these differences should be interpreted cautiously, particularly in light of the potential influence of sequence-related effects.

Humans

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Improving Patient Comfort of Vibratory Anesthetic Devices With a Dampener: A Pilot Study.

BACKGROUND: Vibratory anesthetic devices (VADs) reduce dermatologic injection pain, but their vibration can feel harsh at sensitive anatomical sites. Simple modifications improving patient comfort may enhance VAD adoption. OBJECTIVE: The authors evaluated whether dampening VAD vibration with a cotton buffer improves patient comfort and characterized tactile features influencing preferences. MATERIALS AND METHODS: In a single-site, participant-blinded pilot study (N = 53), adults received a dampened VAD (D-VAD) and standard VAD (S-VAD) at 5 sites-lateral nasal wall, submalar cheek, ear helix, lateral neck, and dorsal forearm-in randomized, contralateral application. Site-specific preference was analyzed with binomial and Cochran Q tests; demographic associations with univariate analyses. Word2vec and hierarchical clustering analyzed qualitative reasons behind patient preference. RESULTS: D-VAD was preferred at all sites across demographics-lateral nasal wall (88.7%), submalar cheek (84.9%), ear helix (88.7%), lateral neck (77.4%), and dorsal forearm (75.5%) (all p < .001), with strongest preference at face and head/neck (p = .018). Computational semantics analysis of qualitative responses identified 6 themes driving preference: Smoothness, Gentleness, Controlled, Low Frequency, Low Intensity, and Less Bothersome. CONCLUSION: Dampening VAD vibration with a cotton buffer enhances comfort across sensitive sites, with reduced harshness and smoother sensation underlying preference. This simple modification may improve patient experience, encouraging broader VAD adoption.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha&#x2122; (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut&#x2122; (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut&#x2122; (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut&#x2122; (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade&#x2122; (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80&#x2009;g/min (95% confidence interval [CI] 6.26-9.34&#x2009;g/min) for Piranha, 4.70&#x2009;g/min (95% CI 3.61-5.79&#x2009;g/min) for VersaCut, 5.90&#x2009;g/min (95% CI 3.16-8.64&#x2009;g/min) for DrillCut, and 9.59&#x2009;g/min (95% CI 4.78-14.39&#x2009;g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75&#x2009;g/min; 95% CI -4.58 to -0.92&#x2009;g/min; P&#x2009;=&#x2009;0.003), with an even greater difference in prostates >70&#x2009;mL (-4.34&#x2009;g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Humans

Exercise Snacks Are Feasible to Perform in the Real World and Improve Physical Capacity for Adults Living With Non-Insulin Treated Type 2 Diabetes: A Randomised Trial.

AIMS: To investigate the feasibility and preliminary efficacy of a 12-week remotely-delivered exercise snacks (ES) intervention in adults with type 2 diabetes. MATERIAL AND METHODS: Insufficiently active adults with type 2 diabetes (N&#x2009;=&#x2009;69; 46 females; mean age&#x2009;&#xb1;&#x2009;SD: 58&#x2009;&#xb1;&#x2009;11&#x2009;years) were randomised to an ES or mobility/stretching comparator group (CON), which involved 4&#x2009;&#xd7;&#x2009;1-min bouts of either vigorous or low intensity exercise, respectively, on &#x2265;&#x2009;5&#x2009;days/week. The primary outcome was feasibility based on adherence. Secondary outcomes included exercise enjoyment (1-7 scale), rating of perceived exertion (RPE; 0-10 scale), heart rate (HR), haemoglobin A1c (HbA1c), blood biomarkers of cardiometabolic health, 30-s sit-to-stand capacity, grip strength, estimated maximal oxygen uptake, and anthropometrics. RESULTS: Weekly adherence (estimated marginal mean [95% confidence interval]: 18 bouts [16-21] for both groups; p&#x2009;=&#x2009;0.99) and total enjoyment (ES: 4.5 [4.1-4.8] vs. CON: 4.3 [4.0-4.7]; p&#x2009;=&#x2009;0.64) were high and not different between groups. Despite higher RPE (5.7 [5.4-6.1]) and peak HR (73 [70-77] % of age-predicted HR maximum) in ES versus CON (2.0 [1.7-2.4] and 61 [58-64] % of age-predicted HR maximum, respectively) (all p&#x2009;<&#x2009;0.001), there were no between-group differences in the change in any secondary outcome (all p&#x2009;>&#x2009;0.05) except for greater sit-to-stand capacity in ES after training (between-group effect estimate [95% confidence interval]: 1.9 repetitions [0.3-3.4]; p&#x2009;=&#x2009;0.02). CONCLUSIONS: Exercise snacks were feasible to perform in the real world and improved sit-to-stand capacity to a greater extent than CON in adults living with type 2 diabetes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT06407245.

Aged

Postoperative Curvature Loss in Three-Level Anterior Cervical Discectomy and Fusion With Zero-Profile Device.

PURPOSE: Cervical curvature loss is a frequent complication following 3-level anterior cervical discectomy and fusion (ACDF) using a Zero-Profile device. Consequently, the capacity of this device to maintain cervical sagittal alignment in 3-level ACDF remains highly controversial. This study aimed to identify potential predictors for postoperative curvature loss (PCL) and evaluate its impact on clinical outcomes. METHODS: A total of 113 patients who underwent ACDF for 3-level cervical degenerative disc disease (CDDD) between January 2021 and December 2023 were retrospectively reviewed. Demographic data, radiological parameters, and clinical outcomes were analyzed. Radiographic measures included cervical curvature, T1 slope, C2-7 sagittal vertical axis, and titanium plate and endplate (TPE) distance. Clinical outcomes were assessed using the Visual Analog Scale (VAS), Neck Disability Index (NDI), and Japanese Orthopaedic Association (JOA) scores. Statistical analyses were performed using paired and independent t-tests, as well as Pearson correlation coefficients. RESULTS: The average curvature loss was 6.82&#xb0; from 1&#x2009;week postoperatively to the final follow-up (p&#x2009;<&#x2009;0.001). However, the final curvature (11.65&#xb0;) was maintained, representing a 4.33&#xb0; improvement compared to preoperative values. Significant correlations were observed between PCL and preoperative curvature (r&#x2009;=&#x2009;-0.368, p&#x2009;=&#x2009;0.013), preoperative T1 slope (r&#x2009;=&#x2009;-0.546, p&#x2009;<&#x2009;0.001), &#x2206;T1 slope (r&#x2009;=&#x2009;0.443, p&#x2009;=&#x2009;0.002), and &#x2206;TPE distance (r&#x2009;=&#x2009;0.417, p&#x2009;=&#x2009;0.004). PCL did not correlate with Japanese Orthopaedic Association (JOA) scores or arm VAS scores at the final follow-up. Nevertheless, patients with a PCL&#x2009;&#x2265;&#x2009;6&#xb0; exhibited significantly higher neck VAS (p&#x2009;=&#x2009;0.028) and NDI scores (p&#x2009;=&#x2009;0.041). CONCLUSION: Although contiguous 3-level ACDF with a Zero-Profile device may result in PCL, it preserves an improved cervical lordosis compared to the preoperative baseline. Low preoperative curvature and a low preoperative T1 slope are potentially predictive factors for PCL. Postoperative changes in TPE distance and T1 slope are significantly associated with PCL, suggesting a potential biomechanical link that requires direct validation. Furthermore, PCL may lead to higher neck VAS and NDI scores. Consequently, the Zero-Profile device may require careful consideration in 3-level CDDD patients presenting with low preoperative curvature and a low T1 slope. Importantly, the 6&#xb0; PCL threshold identified is preliminary and requires prospective validation before clinical application.

Humans

Sensor-based measures of knee brace adherence have low agreement with self-report methods: A multi-measure study among knee osteoarthritis patients.

OBJECTIVE: To explore agreement between self-report and objectively measured adherence to brace wearing by patients with knee osteoarthritis. METHOD: A single-arm observational analysis nested within the PROP OA randomised controlled trial (ISRCTN28555470). Of 237 adults with symptomatic knee osteoarthritis randomised to brace treatment, 60 were included in this sub-study investigating three different methods of assessing knee brace wear time over 26 weeks: 1. Self-report questionnaires (SRQ) at 12 weeks and 26 weeks; 2. Short message service (SMS) questions (days worn in past week, typical hours per day when worn) administered from week 1 to week 24; 3. A skin temperature sensor embedded in the brace, sampling every 10&#x202f;min for 26 weeks. The presence and reason for the sensor were concealed from participants. The estimated proportion of participants meeting "minimum brace use", defined a priori as &#x2265;1&#x202f;h on &#x2265;2 days in past week, was described for each measurement method, overall and by brace type (unloader, neutral). For temperature sensor measurements, time spent above 24&#xb0;C and time spent above 25&#xb0;C were used. Agreement between the measures was summarised by percentage agreement and kappa (&#x138;). RESULTS: The estimated proportions of participants meeting "minimum brace use" at 12 weeks were 83% (SRQ), 83% (SMS), 60% and 58% (temperature sensor, 24&#xb0;C and 25&#xb0;C thresholds, respectively). At 26 weeks, the corresponding estimates reduced to 72%, 71% (SMS at 24 weeks), 43% and 37%. Sensor data suggested the sharpest decline in brace use occurred within the first 12 weeks. Agreement between self-report measures was higher than between self-report measures and sensor (SRQ vs SMS at 12 weeks: 92% agreement, &#x138;=0.67 (95%CI: 0.34, 1.00); SRQ vs Sensor at 12 weeks: 74%, 0.35 (0.10, 0.60); SMS vs Sens at 12 weeks: 76%, 0.36 (0.05, 0.66). Agreement between all measurement methods reduced at 26 weeks. CONCLUSIONS: This novel use of a temperature sensor to monitor brace adherence in knee osteoarthritis indicates that self-report adherence substantially overestimates knee brace wearing time, with implications for clinical trials and practice.

Humans

Use of wearable technologies for physical activity promotion in older adults: A systematic review.

This systematic review, conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251055299), examined the use of wearable technologies for promoting physical activity (PA) in adults aged 60 years and older. Searches across five databases (PubMed, Scopus, Web of Science, CINAHL, Cochrane) identified 2438 records, of which only six randomized controlled trials published between 2021 and 2025 met inclusion criteria, with sample sizes ranging from 36 to 551 participants and mean ages between 65 and 79 years. Given the small number of included studies, findings should be interpreted as preliminary. The studies ranged from the standalone use of commercial trackers (Fitbit, Polar, ActiGraph) to multicomponent interventions combining wearables with physiotherapist feedback, telephone counseling, web-based platforms, or interactive cognitive-motor training. Wearables used alone, as in the REACT trial, produced small or non-significant PA effects. In contrast, interventions integrating devices with personalized feedback, professional support, or digital platforms, such as PROMOTE and TASMANIA, were associated with more consistent improvements in PA, physical function, and cognitive outcomes. Multicomponent programs, such as PEER and ICMT, reported broader benefits, including cognition, balance, and reductions in sedentary behavior, though these findings derive from individual trials and require replication. Risk of bias, assessed with the Cochrane Risk of Bias tool version 2 (RoB 2.0), was rated as "some concerns" for five studies and low for only one, mainly due to gaps in randomization reporting, missing data, and lack of preregistration. Tentatively, and based on a very limited evidence base, wearables may have greater impact when embedded within broader behavioral systems, incorporating feedback, coaching, or interactive components, rather than when used in isolation as passive monitoring tools. Adherence and psychosocial outcomes appeared related to comfort and perceived usefulness among older adults, though larger and more robust trials are needed to confirm these patterns.

Humans

Latent profile analysis of pregnant exercise adherence and the relationship with demographic and socio-psychological factors: a multicentre cross-sectional study.

BACKGROUND: Pregnancy physical activity (PA) and exercise benefits both mothers and babies, but requires sustained adherence. Many pregnant women fail to meet recommended levels. The reasons for low adherence comprised fluctuating physiological and environmental factors. This study aims to identify discrete profiles of pregnant women based on exercise adherence and to examine differences in demographic and socio-psychological factors across these profiles. METHODS: A survey was conducted among 1,255 pregnant women in three hospitals in Shenzhen, Dongguan, and Shunde, China, using the Exercise Adherence Rating Scale (EARS), the Pregnancy Exercise Self-Efficacy Scale (P-ESES), and the Pregnancy Physical Activity Social Support Scale (P-PASSS). In the analysis, EARS items were scored higher, indicating a healthier state (e.g., sufficient time and energy). Latent profile analysis (LPA) was employed to classify adherence profiles, and multinomial logistic regression was used to examine differences in demographic, self-efficacy, and social support across four groups. RESULTS: Four profiles of exercise adherence were identified: (1) Profile 1 (16.97%), characterized by deficits in time and energy, (2) Profile 2 (15.22%), a group with sufficient time resources but the lowest self-efficacy, (3) Profile 3 (43.98%), characterized by high adherence despite moderate barriers, and (4) Profile 4 (23.83%), a group with optimal exercise adherence, confidence, and resources. Women with higher P-ESES (OR: 1.14-1.38) and P-PASSS (OR: 1.04-1.06) scores were more likely to be in Profiles 3 and 4. Additionally, women's partners who never or occasionally exercise were significantly more likely to be categorized into Profile 1 (OR = 0.18 for Profile 4 vs. Profile 1). Furthermore, the first trimester emerged as a significant risk period for lower exercise adherence, whereas overweight/obesity was independently associated with higher odds of membership in Profile 4. CONCLUSION: The study identified four distinct profiles of exercise adherence among pregnant women. 32.19% of participants were in the two lower exercise-adherence groups. Pregnant women in Profile 1 were characterized by challenges related to a lack of time and knowledge. Participants in Profile 2 showed the lowest exercise self-efficacy and social support among the four profiles. Furthermore, women in early pregnancy were more likely to have lower adherence profiles. Hence, targeted interventions addressing these specific groups are warranted to improve exercise adherence during pregnancy.

Humans

Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.

BACKGROUND: For a valid one-repetition maximum (1RM) prediction via load-velocity (LV) relationships, high reliability and accuracy must be assumed. OBJECTIVE: Since individual study results indicate ambivalent prediction, this systematic review and meta-analysis was designed to provide a updated and comprehensive overview, extending knowledge about the validity and reliability of commercially available velocity sensors in Part I and the validity and reliability of velocity-based 1RM prediction models in Part II. METHODS: A systematic literature search was conducted in PubMed/MEDLINE, Web of Science, and Scopus. Validity and/or reliability studies or velocity-based 1RM prediction evaluations were included. Methodological quality was assessed using adapted COSMIN. The analysis was performed for intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), and Pearson's correlation coefficient (r). The review was preregistered in PROSPERO (CRD42025634595). RESULTS: Sixty-three studies were included for sensor validity and reliability and 38 for 1RM prediction models. Part I: Velocity sensors demonstrated good-to-excellent pooled validity and device agreement (ICC&#x2009;=&#x2009;0.91-0.92 [0.83-0.97]; k&#x2009;=&#x2009;55 and 439, respectively); intra- and inter-day reliability were classified as good to excellent with ICC&#x2009;=&#x2009;0.90-0.91 [0.85-0.95] (k&#x2009;=&#x2009;228 and 608, respectively), with sensor technology moderating the results. However, substantial heterogeneity and wide ranges of study-level estimates indicated considerable variability across moderators, linear position transducer (LPT) generally showing more consistent performance than inertial measurement units (IMU). Part II: Velocity-based 1RM prediction showed ICCs&#x2009;=&#x2009;0.90 [0.83-0.94] (k&#x2009;=&#x2009;124) and ICC&#x2009;=&#x2009;0.91 [0.72-0.98] (k&#x2009;=&#x2009;9); for reliability and validity, respectively. DISCUSSION: Commercial velocity sensors generally provide high relative validity and reliability. Results varied depending on exercise complexity, intensity, sensor technology, and modeling approach. While velocity-based 1RM prediction demonstrated high average validity, large heterogeneity in lower body exercises significantly biased the results. Furthermore, the dearth of measurement error and agreement analyses prohibits final conclusions. CONCLUSION: Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.

Load&#x2013;velocity relationship

Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Wearable devices are increasingly used for sleep monitoring and as adjunctive treatment. Existing meta-analyses mostly pool composite digital therapies and rarely isolate stand-alone wearables or distinguish between objective and subjective end points. Whether stand-alone wearable interventions improve sleep outcomes in adults with insomnia, and which factors moderate treatment heterogeneity, remains unclear. OBJECTIVE: This study aims to evaluate the effectiveness of wearable digital interventions on sleep outcomes in adults with insomnia versus control strategies and explore moderators of effectiveness, including device-wearing position, intervention duration, and control type, using meta-regression. METHODS: This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses) 2020 statement and the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses Literature Search Extension) guideline. Five electronic databases and clinical trial registries were searched from inception to May 18, 2026. Eligible studies were randomized controlled trials (RCTs) evaluating wearable digital interventions in adults with insomnia compared with sham, waitlist, usual care, or active control conditions and had an intervention duration of at least 1 week. Study screening, data extraction, and risk-of-bias assessment were carried out independently by 2 reviewers. Pooled estimates were calculated using a restricted maximum likelihood random-effects model with the Hartung-Knapp-Sidik-Jonkman correction. Heterogeneity was assessed using the I&#xb2; statistic, and 95% prediction intervals (PIs) were calculated for the primary analyses. The certainty of evidence was rated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach. RESULTS: Sixteen RCTs (N=910) were included. Wearable digital interventions were associated with a significant reduction in objective sleep-onset latency (SOL; mean difference [MD] -4.52, 95% CI -8.38 to -0.67, PI -9.52 to 0.47 min) and a significant improvement in subjective sleep efficiency (SE; MD 2.00%, 95% CI 1.90%-2.11%, PI 1.85%-2.15%). Subjective total sleep time (TST) also showed a significant increase (MD 19.11, 95% CI 2.98-35.24, PI -16.20 to 54.43 minutes). Meta-regression showed that control type, intervention duration, and device location did not explain the heterogeneity of the insomnia severity index (ISI) (R&#xb2;=0). Sensitivity analysis confirmed the robustness of pooled ISI estimates, and an Egger test indicated no small-study effects (P=.07). Certainty of evidence ranged from moderate to high. CONCLUSIONS: Wearable digital interventions provide selective benefits for objective SOL, subjective SE, and subjective TST in adults with insomnia, with no improvement in overall ISI. Despite statistically significant effects on several sleep parameters, wide PIs, substantial heterogeneity, and limited study numbers indicate preliminary, nonconclusive findings. Wearables should be viewed as affordable adjunctive tools requiring further validation, not substitutes for first-line cognitive behavioral therapy for insomnia. Large-scale, long-term RCTs with standardized protocols and patient-level external validation are required to consolidate the evidence base.

Humans

How AI-supported intelligent systems support infection prevention and control training in healthcare: A systematic review of educational functions and outcomes.

AIMS: Artificial intelligence (AI)-supported intelligent systems have been increasingly incorporated into infection prevention and control (IPC) education and training, primarily to support the monitoring of observable behaviors and the provision of feedback. However, existing evidence has focused largely on short-term compliance outcomes, with limited synthesis of the educational role of AI-supported intelligent systems in supporting sustained IPC competence. This systematic review examined how AI-supported intelligent systems have been designed and used to support IPC education and training, with a focus on system characteristics, educational functions, and reported outcomes. DESIGN: A systematic literature search was conducted across the PubMed/MEDLINE, Embase, Cochrane, and CINAHL databases. DATA SOURCES: A total of 18 studies met the inclusion criteria. Findings were qualitatively synthesized according to system design characteristics, educational functions, and outcome domains. REVIEW METHODS: Methodological quality was appraised using the Mixed Methods Appraisal Tool. RESULTS: Most AI-supported intelligent systems focused on hand hygiene and relied on fully automated monitoring systems to capture behaviors and provide performance feedback. Educational functions were predominantly limited to performance assessment, automated feedback, and reminders. Outcomes were mainly measured using compliance or performance metrics, whereas sustained behavioral change and decision quality were rarely assessed. CONCLUSIONS: AI-supported intelligent systems have been used primarily to reinforce short-term IPC performance and compliance. However, their current applications for supporting sustained competence over time remain limited. The findings of this review suggest that AI-supported intelligent systems may serve as maintenance-oriented educational support by extending learning beyond initial instruction through repeated practice and feedback. Future research should prioritize outcome measures that capture the durability of performance and decision-making processes to better align AI-supported intelligent systems used in IPC education and training with the educational demands of clinical practice.

Humans