Search PubMedSearch

SEARCH · Search PubMed

Results for “Delphi technique”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

132 records · Page 2Linked to original sources

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

Endoscopic mucosal resection with precutting vs. anchoring technique using snare tip for 10-25 mm nonpedunculated colorectal polyps: a randomized controlled trial.

BACKGROUND AND AIMS: Modified endoscopic mucosal resection (EMR) techniques using a snare tip, precutting EMR (P-EMR) and anchoring EMR (A-EMR), have been developed for the effective resection of nonpedunculated colorectal polyps measuring 10-25&#x2005;mm. Although previous studies have compared either P-EMR or A-EMR with conventional EMR, no study has directly compared these two snare tip-assisted techniques within modified EMR. This study aimed to evaluate P-EMR and A-EMR in terms of the R0 resection rate and procedure duration. METHODS: This prospective randomized controlled trial enrolled patients with nonpedunculated colorectal polyps measuring 10-25&#x2005;mm. The patients were randomly assigned to the P-EMR or A-EMR groups. The primary outcome was R0 resection rate, defined as en bloc resection with histologically tumor-free margins. Secondary outcomes included the injection-to-snaring time, total procedure time, and adverse events. RESULTS: Each group included 63 polyps, of which 126 were analyzed in the final evaluation. Both groups achieved high R0 resection rates (93.7% for P-EMR and 88.9% for A-EMR), with no significant difference ( P &#x2005;=&#x2005;0.344). However, the A-EMR group demonstrated significantly shorter injection-to-snaring time (181.8&#x2005;&#xb1;&#x2005;81.9 vs. 320.9&#x2005;&#xb1;&#x2005;143.5&#x2005;s, P &#x2005;<&#x2005;0.001) and total procedure time (259.7&#x2005;&#xb1;&#x2005;139.7 vs. 479.8&#x2005;&#xb1;&#x2005;249.0&#x2005;s, P &#x2005;<&#x2005;0.001). Adverse events, including intraprocedural and delayed bleeding, were comparable between the groups. CONCLUSION: Both P-EMR and A-EMR demonstrated high R0 resection rates for nonpedunculated polyps measuring 10-25&#x2005;mm. However, A-EMR achieved these outcomes with a shorter procedure time than P-EMR.

Humans

Artificial neural network data fusion-mediated dual-mode sensor based on Fe3O4@PdIr for Salmonellatyphimurium detection in food.

Salmonella Typhimurium (S. typhimurium) is a major foodborne pathogen that poses a serious threat to public health. In this study, a colorimetric/electrochemical dual-mode biosensor assisted by artificial neural network (ANN) was developed for the sensitive detection of S. typhimurium. Fe3O4@PdIr nanocomposites with enhanced peroxidase-like activity and electrochemical performance were prepared and conjugated with an aptamer specific to S. typhimurium to obtain Fe3O4@PdIr-Apt. Through the sandwich binding of Fe3O4@PdIr-Apt and Apt to the target, the nanocomposites were attached to microplates or Au electrodes, thereby generating colorimetric and electrochemical signals. The ANN model deeply resolved the complex nonlinear relationship between the dual signals, enabling mutual correction and ultimately performing data fusion to output a single detection result, which significantly reduced the mean square error while improving detection sensitivity and reliability. This sensor exhibited a wide linear range of 2.7-2.7&#xa0;&#xd7;&#xa0;108&#xa0;CFU/mL and a low detection limit of 1.66&#xa0;CFU/mL. Additionally, this method was successfully applied to the detection of S. typhimurium in pork and milk, with a recovery rate of 95.19%&#xa0;&#x223c;&#xa0;104.07%. It indicated that the constructed sensor holds great practical potential for S. typhimurium detection.

Neural Networks, Computer

Spatially confined electrochemical strategy with DNA-assembled nanogaps for SNP detection.

Accurate detection of low-abundance single nucleotide polymorphisms (SNPs) against a large excess of homologous wild-type sequences requires both selective molecular recognition and effective transduction of small sequence differences into measurable signals. Here, we report a spatially confined electrochemical strategy that couples sequence-selective recognition with size-dependent mass-transport gating. DNA-hybridization-driven self-assembly of gold nanoparticles (AuNPs) forms a three-dimensional self-assembled electrode (3D-SAE) with a DNA-defined interparticle architecture. Competitive probes (SP/WP) convert single-base recognition into distinct molecular-size states: the SNP-associated pathway preferentially triggers a hybridization chain reaction (HCR), generating bulky AuNP-anchored HCR/methylene blue complexes (Au@HCR/MB) with reduced electrochemical accessibility through the porous 3D-SAE, whereas the wild-type pathway does not trigger HCR and maintains a high-current response from more readily accessible MB-containing species. Thus, sequence recognition is translated into a molecular-size difference and subsequently into an electrochemical signal through differential mass transport. Under buffer conditions, the platform achieved a statistically estimated detection limit of &#x223c;0.47&#x202f;fM and a quantitative range of 1&#x202f;fM-100 pM. It discriminated a 0.1% mutant abundance in a fragmented genomic-DNA background. The downstream signal-transduction chemistry is enzyme-free and isothermal. This work establishes a mechanistical recognition-size-conversion-mass-transport-gating architecture for electrochemical nucleic acid analysis.

Polymorphism, Single Nucleotide

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (&#x2265;&#x2009;13&#x2009;mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2&#x2009;=&#x2009;0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2&#x2009;=&#x2009;59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

Rational design of high-productivity perfusion processes for CHO Cells: From growth inhibitory strategies to model-driven optimization.

While perfusion culture for Chinese hamster ovary (CHO) cells offers advantages such as continuous operation and flexibility, it suffers from product loss through cell bleeding and difficulties in reaching high productivity due to sustained rapid cell growth. Growth inhibitory strategies are widely used to enhance productivity in fed&#x2011;batch processes; however, their practical implementation and comparative effectiveness in perfusion processes remain insufficiently explored. Meanwhile, process development often relies on costly trial&#x2011;and&#x2011;error approaches. Here, we systematically compared three growth inhibitory strategies in perfusion culture-low cell&#x2011;specific perfusion rate (CSPR), sodium butyrate, and mild hypothermia-with respect to cell growth, metabolism, productivity, and product quality. Genome&#x2011;scale metabolic flux sampling analysis revealed that low&#x2011;CSPR and sodium butyrate induce a convergent up&#x2011;regulation of energy metabolism, correlating with greater gains in specific productivity (qp). Building on this insight, we developed a growth&#x2011;kinetic model for the combined low&#x2011;CSPR + butyrate strategy, incorporating parameter uncertainty. This model&#x2011;guided framework enabled the rational design of two distinct high&#x2011;productivity perfusion processes: a sustained mode that achieved robust long&#x2011;term stability alongside substantial productivity gains, and a high&#x2011;intensity mode that pushed qp and daily volumetric titer to their maxima, with increases of up to 108.94% and 190.36%, respectively, in a model CHO cell line with a moderate baseline productivity. Our study provides a proof&#x2011;of&#x2011;concept framework for perfusion intensification, from strategy selection to rational process design.

Animals

Hysteroscopic platelet-rich plasma and medically assisted reproduction outcomes: a systematic review and SWOT analysis.

BACKGROUND: Platelet-rich plasma (PRP) has been proposed as an adjuvant treatment in reproductive medicine. While most evidence refers to blind intrauterine instillation, subendometrial administration under hysteroscopic guidance allows targeted delivery under direct visualisation. This systematic review aimed to synthesise the available evidence on hysteroscopic PRP administration and its impact on clinical medically assisted reproduction (MAR) outcomes. METHODS: A systematic search was conducted from inception to December 2025 across major databases. Studies were included if they evaluated hysteroscopic PRP administration in women undergoing MAR, comparing reproductive outcomes between treated and control groups. RESULTS: Out of 142 records, 3 studies met the inclusion criteria. Study populations were heterogeneous and included women with refractory thin endometrium and/or a history of implantation failure. Hysteroscopic PRP administration protocols varied in timing, technique, and dosage. In a prospective case-control study, hysteroscopic intraendometrial PRP injection at a depth of 2-3&#x2009;mm in the four uterine walls, using an ovum aspiration needle, on days 11-13 of the cycle prior to euploid frozen embryo transfer (ET), was associated with higher implantation (IR), clinical pregnancy (CPR), and live birth rates (LBR) compared with standard therapy. Conversely, no significant differences in CPR, miscarriage rate, or LBR were observed in an observational study evaluating a single intraendometrial PRP injection (35-40&#x2009;mL, 2-3&#x2009;mm depth), administered via endoscopic needle on days 6-8 of the menstrual cycle preceding frozen ET, alone or after electrical impulse therapy. A randomised controlled trial in women undergoing intrauterine insemination reported a significant improvement in CPR following hysteroscopic subendometrial PRP instillation in the four uterine walls (1.0&#x2009;mL each). CONCLUSIONS: Current literature on hysteroscopic PRP administration in reproductive medicine is limited, and robust conclusions cannot yet be drawn. Well-designed randomised controlled trials with standardised protocols are needed to clarify its clinical role.

Humans

Adding Rib Mobilization to Diaphragm Release Techniques in Patients With Non-Specific Neck Pain: Randomized Controlled Trial.

BACKGROUND: Non-specific neck pain (NSNP) is a frequent issue that can negatively affect both mobility and function. Recently, there has been growing interest in newer therapeutic approaches, including rib mobilization and diaphragm release techniques, as potential ways to address NSNP and support better outcomes for those affected. PURPOSE: To find out the immediate effects of how (DRT) combined with (RMT) affects the level of pain and the extent to which patients' functional abilities are improved in cases of NSNP. METHODS: For this prospective RCT, 96 participants aged 20 to 45&#xa0;years were randomly assigned to one of three equal groups based on their pain score (VAS). Group B engaged in (DRT) for 40&#xa0;minutes, three times weekly for 8&#xa0;weeks, in contrast to Group A, which got both RMT combined with DRT. Group C (active control) received advice and some exercises. Measurements were collected before and after the intervention; the primary outcomes included pain severity, evaluated using a visual analog scale (VAS); active neck range of motion (ROM), measured with a cervical range of motion (CROM) device; and neck flexion endurance. Additionally, the secondary outcome of neck-related disability was assessed using the Neck Disability Index (NDI). RESULTS: No statistically significant difference was identified among the three groups at baseline; nevertheless, a treatment effect emerged after 8&#xa0;weeks (p&#xa0;=&#xa0;0.001 and f-value&#xa0;=&#xa0;4.15, &#x19e;2&#xa0;=&#xa0;0.306). A statistically significant time-treatment interaction was seen when comparing the pre- and post-treatment periods in groups A and B (p&#xa0;=&#xa0;0.001, f-value&#xa0;=&#xa0;3.16, &#x19e;2&#xa0;=&#xa0;0.251). CONCLUSION: The addition of rib mobilization to diaphragm release techniques in patients with non-specific neck pain resulted in statistically significant improvements in pain intensity, cervical flexion, right lateral rotation, left lateral rotation, right rotation, and neck flexor endurance, with moderate to large effect sizes for pain reduction and cervical motion. However, no statistically significant differences were observed between groups for cervical extension, left rotation, or the Neck Disability Index (NDI), and only a marginal clinical improvement in NDI was noted in Group A. The observed benefits in the combined intervention group may not be attributable solely to rib mobilization. The increased treatment complexity and greater therapist interaction inherent in the combined approach could also have influenced the outcomes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT07133646.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Stapled versus hand-sewn intestinal anastomosis in pediatric surgery: A systematic review and meta-analysis.

BACKGROUND: Intestinal anastomosis is a core procedure in pediatric gastrointestinal surgery, performed for conditions such as necrotizing enterocolitis, intestinal atresia, Hirschsprung's disease, and inflammatory bowel disease. Although stapled anastomosis (SA) may improve operative efficiency, its safety and effectiveness compared with hand-sewn anastomosis (HA) in children remain uncertain. This meta-analysis compared clinical outcomes of SA and HA in pediatric patients. METHODS: The study followed PRISMA guidelines and was prospectively registered in PROSPERO (CRD420251177257). A systematic search of PubMed, Dimensions, and the Cochrane Library was conducted through June 2025. Studies including children under 7 years undergoing intestinal SA or HA were eligible. Two reviewers independently performed study selection, data extraction, and risk-of-bias assessment using ROB 2 and ROBINS-I tools. Statistical analysis was conducted using Comprehensive Meta-Analysis software (v3) with a random-effects model. RESULTS: Eleven studies involving 903 patients met inclusion criteria, including two randomized controlled trials. Of these, 333 patients underwent SA and 570 underwent HA. SA was associated with significantly shorter operative time (mean difference [MD] = -19.26 min; 95% CI: -24.24 to -14.28; p < 0.001) and earlier initiation of oral feeding (MD = -2.32 days; 95% CI: -3.78 to -0.86; p = 0.002). No significant differences were found in anastomotic leakage, stricture formation, reoperation rate, or length of hospital stay. CONCLUSIONS: Stapled anastomosis appears as safe as hand-sewn techniques in pediatric intestinal surgery while offering shorter operative duration and faster postoperative feeding recovery. Selective use of stapled techniques is supported when anatomically feasible, though further multicenter randomized trials are needed.

Humans

Interfacial engineering of cobalt tungstate-halloysite nanotube nanocomposite for electrochemical detection of synthetic vanillin in food matrices.

In processed foods and medicine, synthetic vanillin is widely used, although excessive intake poses toxicological risks. Due to the rising usage of synthetic vanillin in food products and associated health hazards, quick, sensitive, and reliable analytical methods are needed to precisely measure vanillin in complex food matrices. This work introduces a CoWO4@F-HNT/GCE nanocomposite as an efficient electrocatalytic modifier for glassy carbon electrodes aimed at trace-level synthetic vanillin detection. Structural and microscopic analyses confirmed phase-pure monoclinic CoWO4, preservation of the tubular aluminosilicate framework, and homogeneous nanoparticle anchoring on F-HNT. Differential pulse voltammetry provided a broad linear range from 0.01 to 372.14&#xa0;&#x3bc;M and a low detection limit of 4.3&#xa0;nM, together with excellent selectivity against common interferents, good cycling stability, and high inter-electrode reproducibility. These characteristics position the CoWO4@F-HNT-modified electrode as a cost-effective and reliable platform for on-site quality control of synthetic vanillin in complex food matrices.

Benzaldehydes

Morphology-engineered NiFe@C nanocages boosting electrochemical quantification of ractopamine in meat samples.

It is essential to acquire efficient electrocatalysts to develop ractopamine (RAC) electrochemical sensors. Herein, we report the synthesis of a series of carbon coated NiFe alloy nanostructures (e.g., NiFe@C nanoparticles, nanocubes and nanocages) using NiFe Prussian blue analogue (PBA) as the precursor. The NiFe@C nanocages exhibited the best electrocatalytic performance for RAC sensing. This is attributed to the embedded NiFe alloy nanoparticles that provide abundant active sites, and the unique nanocage structure facilitates electron transfer pathways while offering a high specific surface area. The resulting sensor achieves a low detection limit (LOD) of 54&#xa0;nM (S/N&#xa0;=&#xa0;3) within a linear range of 0.2-12&#xa0;&#x3bc;M. Moreover, the sensor demonstrates good reproducibility, stability, and excellent long-term stability. Practical applicability was confirmed in meat samples, yielding satisfactory recovery rates ranging from 98% to 108%. A feasible strategy was introduced herein for rational design of metal@carbon electrocatalysts.

Phenethylamines

Machine learning-assisted Mn-N-C nanozyme colorimetric sensor array for trace-level detection of biogenic amines in meat.

Accurate detection of biogenic amines (BAs) in meat remains challenging due to their high structural similarity and co-occurrence. Herein, an Mn-N-C nanozyme was synthesized via a metal-organic framework confined pyrolysis strategy, possessing excellent oxidase (OXD)- and peroxidase (POD)-like activities. The dual enzyme-like activity showed Km values of 0.1584&#xa0;mM (OXD) and 0.1498&#xa0;mM (POD), respectively, in detection system. Leveraging these properties, a colorimetric sensor array was constructed, enabling the detection of four representative BAs within a concentration range of 2-10&#xa0;ppm with 100% classification accuracy. In addition, a concentration independent recognition model based on an artificial neural network was developed to address signal nonlinearity interference in meat. The integrated system achieved accurate trace-level identification of BAs in perishable fish, pork, and chicken, demonstrating its applicability for early-stage BAs monitoring and quality deterioration warning during storage and transportation.

Biogenic Amines

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine&#x2011;hydrogen peroxide (TMB-H&#x2082;O&#x2082;) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82&#xa0;CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

PdIr bimetallic nanozyme engineered metal-organic frameworks integrated dual-mode sensor toward Stx2 detection in food.

Shiga toxin II (Stx2) has attracted extensive attention due to its toxicity and pathogenicity, making the development of sensitive detection methods urgent. This study constructed a dual-mode sensing platform for the sensitive detection of Stx2 in food. Composite material UIO-66@PdIr with peroxidase-like activity and fluorescent properties was synthesized and combined with cDNA as the signal probe, while aptamer-modified magnetic beads served as the capture probe. Specific binding of Stx2 to the aptamer triggered the release of the signal probe, enabling colorimetric and fluorescence signal readout. The colorimetric mode showed a linear range of 0.05-100&#xa0;ng/mL with an LOD of 0.039&#xa0;ng/mL, and the fluorescence mode exhibited 0.01-1000&#xa0;ng/mL with an LOD of 0.0097&#xa0;ng/mL. Additionally, this method was successfully applied to the detection of Stx2 in food, and the recovery rates were 94.33%&#xa0;&#x223c;&#xa0;102.20%. It indicated that the constructed sensor holds great practical potential for Stx2 detection.

Food Contamination

A MIL-88@Ru-based molecularly imprinted electrochemiluminescence sensor for highly selective and sensitive detection of enrofloxacin residues in animal-derived foods.

Using a metal-organic framework (MOF) - supported Ru(bpy)32+ (MIL-88@Ru) composite luminescent material, this study innovatively adopted electropolymerization to fabricate a molecularly imprinted polymer-based electrochemiluminescent (MIP-ECL) sensor for enrofloxacin (ENR) detection in animal-derived foods. Systematic investigation of the ECL luminescence and ENR's quenching mechanism confirmed that the sensor integrates ECL's high sensitivity and MIP's high specificity, enabling rapid and accurate recognition of ENR. Experimental results show a good linear response in the range of 1&#xa0;nmol/L-20&#xa0;&#x3bc;mol/L (R2&#xa0;=&#xa0;0.99), a limit of detection (LOD) as low as 0.28&#xa0;nmol/L, as well as excellent selectivity and stability. Recoveries of ENR in all investigated matrices ranged from 97.7% to 106.4%, confirming the reliability of the established method. This ECL-MIP coupling strategy provides a new technical approach and application references for the efficient detection of trace pollutants in food safety and environmental monitoring fields.

Enrofloxacin

DNM1L depletion leads to accelerated heteroplasmy shifting of m.10191C allele through ATG7-dependent pathways.

Nucleotide composition bias in mitochondrial DNA (mtDNA) makes the heavy strand prone to form a DNA secondary structure called a guanine quadruplex (G4). This secondary structure has been shown to inhibit polymerase processivity in vitro. We previously identified pathogenic mtDNA variants that lead to increased G4-forming propensity, including a T to C mutation at m.10191 (m.10191&#xa0;T&#xa0;>&#xa0;C) that causes Leigh syndrome. Cells treated with G4 binding agent (G4BA) berberine show a reduction in m.10191C pathogenic heteroplasmy levels. To help better understand the underlying mechanism behind berberine-induced heteroplasmy shift, we examined the relationship between mitochondrial fission and berberine-mediated shift. Here we show that knockdown of the fission factor DNM1L leads to an accelerated heteroplasmy shift towards the healthy mtDNA allele, lowering m.10191C by 10% in 3&#xa0;weeks, compared to the 5&#xa0;weeks required for berberine alone. The specific mechanism involves ATG7, as knockdown of ATG7 is able to partially delay this accelerated heteroplasmy shift. Taken together, we show that DNM1L knockdown is able to accelerate berberine-induced m.10191C heteroplasmy shifting through an autophagy-related mechanism.

Humans