Search PubMedSearch

SEARCH · Search PubMed

Results for “Blood Vessel Prosthesis Implantation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

363 records · Page 2Linked to original sources

Effect of Baseline ASPECTS on Tenecteplase Efficacy Before Thrombectomy in Acute Large-Vessel Occlusion Stroke: A Post Hoc Analysis of the BRIDGE-TNK Randomized Trial.

BACKGROUND AND OBJECTIVES: The impact of ischemic extent on the efficacy and safety of intravenous thrombolysis before thrombectomy remains uncertain. The aim of this study was to evaluate whether the baseline ischemic extent, measured by the Alberta Stroke Program Early Computed Tomography Score (ASPECTS), modifies outcomes of intravenous tenecteplase administered before endovascular thrombectomy. METHODS: This was a post hoc analysis of the BRIDGE-TNK (thrombectomy with vs without rhTNK-tPA in stroke) trial, conducted across China from May 2022 to September 2024. We compared the efficacy and safety of intravenous tenecteplase plus thrombectomy vs thrombectomy alone in acute large-vessel occlusion stroke patients within 4.5 hours of last known well, stratified by baseline ASPECTS (<8 vs 8-10). The outcomes included 90-day functional independence (modified Rankin Scale score of 0-2), 48-hour symptomatic intracranial hemorrhage (sICH), and 90-day mortality. Regression models incorporating a treatment-by-ASPECTS interaction term were used for analysis. RESULTS: Among 550 patients, 241 (43.8%) had ASPECTS <8 (median [interquartile range, IQR] age, 69 [61-77] years; 56.4% male) and 309 had ASPECTS 8-10 (median [IQR] age, 70 [61-77] years; 59.5% male). The rate of functional independence was significantly higher in the tenecteplase plus thrombectomy group than in the thrombectomy-alone group in the ASPECTS <8 subgroup (adjusted risk ratio [aRR], 1.67; 95% CI 1.18-2.35), but not in the ASPECTS 8-10 subgroup (aRR, 0.99; 95% CI 0.84-1.17; pinteraction = 0.007). Rates of sICH did not differ significantly between treatment groups in either ASPECTS subgroups (ASPECTS <8: 10.0% vs 11.2%; ASPECTS 8-10: 7.5% vs 2.8%; pinteraction = 0.11). Ninety-day mortality was comparable between treatment groups in the ASPECTS <8 subgroup, but numerically higher with tenecteplase plus thrombectomy in the ASPECTS 8-10 subgroup (aRR = 1.89, 95% CI 0.99-3.61, pinteraction = 0.04). DISCUSSION: In this exploratory post hoc analysis, a signal of benefit was observed in patients with ASPECTS <8 who received intravenous tenecteplase before thrombectomy, whereas no functional improvement and possible safety concerns were seen in those with ASPECTS 8-10. Prospective confirmation in randomized trials is required before practice change. TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov; Unique identifier: NCT04733742.

Humans

Alignment strategies in total knee arthroplasty and the patellofemoral joint: A systematic review.

BACKGROUND: Different alignment strategies in total knee arthroplasty (TKA) may affect the patellofemoral joint. Mechanical alignment (MA) is commonly used but may alter native anatomy. Newer strategies such as kinematic alignment (KA), restricted kinematic alignment (rKA), and functional alignment (FA) aim to better restore native joint mechanics. This study provides an overview of the effects of alignment strategies on patellofemoral outcomes after TKA. METHODS: A literature search in July 2025 identified studies comparing patellofemoral outcomes in TKA using different alignment strategies. Of 166 studies screened, eight met inclusion criteria. Three studies were considered medium quality and five studies low quality. RESULTS: KA and rKA more closely restored native trochlear morphology than MA and FA, reducing outliers in the anterior trochlear line compared with MA and FA. MA showed greater trochlear translation, suggesting worse patellar tracking. Trochlear angles were more anatomical in KA and rKA. However, KA was associated with increased internal femoral component rotation and more outliers beyond safe thresholds. FA showed more consistent rotational positioning, generally within safe limits. Lateral patellar shift and intraoperative lateral release rates did not differ significantly between KA and MA. Only one study reported patella-specific clinical outcome scores, finding no difference between FA and adjusted MA. CONCLUSION: KA and rKA better restore trochlear morphology, but risk excessive internal femoral component rotation. FA provides a more balanced approach. MA, while widely used, is linked to altered trochlear shape and worse patellar tracking. The clinical impact of these radiological differences remains unclear, and higher-quality studies are needed.

Humans

Robotic assistance in total hip arthroplasty: a systematic review and meta-analysis of leg length, cup orientation, and early outcomes.

This review examined whether robotic assistance alters postoperative leg-length discrepancy (LLD), acetabular cup orientation, or early hip-specific outcomes relative to conventional total hip arthroplasty (THA). We searched PubMed and Web of Science through May 2026 for comparative English-language reports. Study eligibility, data extraction, and methodological appraisal were undertaken independently by two reviewers. Mean differences (MDs) and 95% confidence intervals (CIs) were calculated in Review Manager 5.4. Model selection was based on the target estimand and anticipated clinical and methodological diversity; leave-one-out and alternative-model sensitivity analyses were undertaken for heterogeneous outcomes. The protocol is registered with PROSPERO (CRD420261454043). The review included seven studies and 968 participants. Compared with conventional THA, robot-assisted THA yielded a smaller postoperative LLD (MD = -2.02, 95% CI -3.46 to -0.58; P = 0.006) and a higher Harris Hip Score (MD = 2.96, 95% CI 1.12 to 4.80; P = 0.002). Mean cup anteversion was lower in the robotic group (MD = -1.52, 95% CI -2.29 to -0.76; P < 0.0001), whereas cup inclination did not differ (MD = -0.71, 95% CI -3.26 to 1.83; P = 0.58). The robotic group also had higher Forgotten Joint Score (MD = 14.68, 95% CI 5.02 to 24.33; P = 0.003) and Oxford Hip Score values (MD = 2.61, 95% CI 0.71 to 4.51; P = 0.007). Robotic assistance was linked to a modest improvement in leg-length restoration and to higher scores on several early functional measures. The limited number of studies, predominance of nonrandomized designs, and marked heterogeneity in some analyses temper the certainty of these findings.

Humans

Addressing lignin composition and content via Arabidopsis arogenate dehydratase knockout and over-expression genotypes.

Following the down-selection of 14 Arabidopsis thaliana arogenate dehydratase (ADT) knockout and over-expression (OE) genotypes, the most highly contrasting quadruple knockout adt3/4/5/6 and ADT OE genotypes were subjected to proteomics, metabolomics, and scanning electron microscopy (SEM) analyses as needed, with results compared to Columbia wild-type (WT). The basal adt3/4/5/6 stem cross-sections, &#x223c;70% lignin content reduced, exhibited buckled vessel cell walls and partially detached xylary fibers, in contrast to WT and ADT4m/5&#x202f;m OE genotypes that did not. Anatomical defects primarily resulted from guaiacyl lignin level reductions in vessels with concomitant increased stem syringyl:guaiacyl (S/G) ratios. Phenylpropanoid and various upstream shikimate-chorismate pathway enzyme abundances, as well as specific monolignol oxidases (laccases/peroxidases), generally increased in adt3/4/5/6&#x202f;at different stem and rosette leaf growth/development stages, relative to WT. Opposite effects were largely observed with the ADT5m OE genotype. By contrast, flavonoid and glucosinolate pathway enzyme amounts varied. Such enzyme abundance increases were overall unproductive as adt3/4/5/6 was unable to restore WT, ADT4 OE, ADT5 OE, ADT5m OE, and ADT4m/5&#x202f;m OE secondary metabolite (lignin, phenylpropanoid, lignan, flavonoid, phenolic acid, and glucosinolate) levels. Conversely, ADT OE genotypes did not significantly increase programmed lignin levels or alter S/G compositions. In sum, proteomics analyses of adt3/4/5/6 and adt5 'perceived' that lignin and low molecular weight secondary metabolite amounts were not at 'programmed' levels as for WT and ADT OE genotypes but observed increases in relevant pathway protein abundances were futile. Notably though, proteomics analyses did not lead to predicting that lignin and associated biochemical pathways would have reduced metabolite levels, relative to WT and ADT OE genotypes. Genotype adt3/4/5/6, possibly the highest lignin level reduced genotype reported, did not utilize other phenolics to compensate. By contrast, the differential temporal and spatial deposition of cell wall oxidases again indicate the exquisite control over lignin deposition, and our lack of knowledge of precise lignin structure and assembly in subcellular regions of the lignified cell walls.

Lignin

Endovascular intervention for acute stroke in the very late window: A meta-analysis of 90-day mRS and procedural outcomes.

OBJECTIVE: This study investigates the effectiveness of Endovascular Therapy (EVT) in very late windows (beyond 24&#xa0;h) for patients with ischemic stroke, focusing on 90-day mortality, functional outcomes, and procedural success. METHODS: This systematic review and meta-analysis followed Cochrane and PRISMA guidelines to evaluate the effectiveness of endovascular therapy (EVT) in acute ischemic stroke patients. Literature from PubMed, Embase, Web of Science, and Scopus was reviewed using specific keywords. Studies included those after 2000 with outcomes such as functional independence (mRS 0-2), mortality, TICI scores, and neurological improvements. RESULTS: The data findings reveal mixed outcomes across studies on EVT beyond 24&#xa0;h. Sarraj et al. (2023) found a significant improvement in functional independence with EVT (38% vs. 10%, p&#xa0;<&#xa0;0.05), despite an increased risk of sICH. The forest plots for mRS and procedural outcomes show some significant results, such as Sarraj (2023) for mortality (p&#xa0;<&#xa0;0.05), but most other studies indicated no statistically significant differences (p&#xa0;>&#xa0;0.05). CONCLUSION: The study has concluded that Endovascular Therapy (EVT) beyond 24&#xa0;h can improve functional outcomes and reduce mortality in selected ischemic stroke patients, though patient selection remains crucial.

Humans

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (&#x2265;&#x2009;13&#x2009;mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2&#x2009;=&#x2009;0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2&#x2009;=&#x2009;59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

Impact of Diabetes on Outcomes of Contemporary PCI Guided by OCT vs Angiography: The ILUMIEN IV Trial.

BACKGROUND: Patients with diabetes are at higher risk for adverse events after percutaneous coronary intervention (PCI) compared with patients without diabetes. OBJECTIVES: This study sought to assess the influence of diabetes and complex lesions on the outcomes of patients undergoing PCI with and without optical coherence tomography (OCT) guidance during a follow-up period of 2 years. METHODS: Patients in ILUMIEN IV randomized to OCT-guided vs angiography-guided PCI were grouped into those with (n = 1,044) and without diabetes (n = 1,443). Study endpoints were target vessel failure (TVF) and serious major adverse cardiovascular events (MACE). RESULTS: After adjustment for differences in clinical and angiographic characteristics, the 2-year rates of both TVF (9.9% vs 6.3%; adjusted HR: 1.48; 95% CI: 1.09-2.02; P = 0.01) and serious MACE (5.3% vs 2.7%; adjusted HR: 1.77; 95% CI: 1.14-2.76; P = 0.01) were increased in diabetic compared with nondiabetic patients, consistently in patients with and without complex lesions (Pinteraction = 0.22 and 0.14, respectively), although the highest 2-year rates were in patients with diabetes and complex lesions. In all randomized patients, OCT guidance compared with angiography guidance did not reduce TVF or serious MACE. These effects were consistent in patients with and without diabetes (Pinteraction = 0.41 and 0.20, respectively), and were not modified by treatment of complex lesions. CONCLUSIONS: In the large-scale ILUMIEN IV trial, patients with diabetes remained at increased risk for adverse events after PCI compared with nondiabetic patients despite the use of OCT procedural guidance. Patients with diabetes and complex lesions were at particularly high risk for adverse outcomes after PCI.

Humans

Comparative efficacy and safety of bi-flanged metal stents versus lumen-apposing metal stents for endoscopic drainage of pancreatic fluid collections: a systematic review and meta-analysis.

INTRODUCTION: Pancreatic fluid collections (PFCs), particularly walled-off necrosis, are common complications of acute pancreatitis that often require endoscopic drainage. Bi-flanged metal stents (BFMS; NAGI; Taewoong Medical, Gyenoggi-do, Korea) and electrocautery-enhanced lumen-apposing metal stents (LAMS; AXIOS, Boston Scientific Corporation, Marlborough, Massachusetts, USA) are frequently used, but comparative data remain limited. This study aims to compare the efficacy and safety of BFMS and LAMS in the endoscopic drainage of PFCs. METHODS: This meta-analysis followed the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Comprehensive database searches were conducted through November 2024 to identify studies comparing BFMS and LAMS for endoscopic ultrasound-guided drainage of PFCs. Outcomes were pooled using a random-effects model with RevMan Web, and statistical significance was defined as a P value less than 0.05. RESULTS: Three studies ( n &#x2005;=&#x2005;627; 329 BFMS and 298 LAMS) met inclusion criteria. No significant differences were observed between BFMS and LAMS for technical success [odds ratio (OR): 1.16; 95% confidence interval (CI): 0.55-2.43] or clinical success (OR: 0.97; 95% CI: 0.51-1.87). Similarly, there were no differences in walled-off necrosis recurrence (OR: 2.01; 95% CI: 0.17-24.02), number of direct endoscopic necrosectomy sessions (OR: 0.52; 95% CI: 0.05-5.12), or mean number of endoscopic procedures (mean difference: 0.18, 95% CI: 2.08-2.45). Adverse events were also comparable between groups, including bleeding (OR: 0.64), infection (OR: 1.18), stent migration (OR: 1.83), and stent occlusion/dysfunction (OR: 1.71). CONCLUSION: BFMS and LAMS provide equivalent efficacy and safety in the endoscopic ultrasound-guided drainage of PFCs. Either stent type represents a viable therapeutic option. Further large-scale prospective studies are warranted to refine stent selection strategies.

Humans

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Influence of endodontic access on the fracture resistance, retention and microleakage of full-coverage restorations in vitro: A systematic review and meta-analysis.

BACKGROUND: Endodontic access through retained full-coverage restorations (FCRs) is a preferred option for patients because of its high cost-effectiveness. However, the clinical performance of FCRs after repaired access cavity remains insufficiently characterized. This systematic review investigates the effects of endodontic access cavity preparation through retained FCRs on fracture resistance, retention, and microleakage based on in vitro studies. METHODS: A comprehensive search was performed in PubMed, Web of Science, and Scopus databases. Studies investigating the influence of endodontic access on the fracture resistance, retention, and microleakage of FCRs were included. Two independent reviewers conducted study selection, data extraction, and risk-of-bias assessment using the QUIN tool. Meta-analysis was employed to estimate fracture resistance and retention, with sensitivity analysis and subgroup evaluation also performed. Microleakage was summarized qualitatively. RESULTS: Twentythree studies were included: fracture resistance (n = 15), retention (n = 5), and microleakage (n = 3). Endodontic access significantly reduced fracture resistance for zirconia (p = 0.0002) and lithium disilicate (LD) restorations (p = 0.007), but not for resin-matrix ceramic (RMC) restorations (p = 0.25). Abutment tooth type contributed to heterogeneity within the LD and RMC subgroups. Retention was significantly reduced when access cavities were left unrepaired (p = 0.03), whereas appropriate repair protocols restored or enhanced retention relative to baseline. Accelerated aging increased microleakage in retained FCRs. Surface pretreatments and flowable resin liners tended to reduce microleakage, but findings were inconsistent. CONCLUSIONS: Endodontic access significantly reduces fracture resistance of zirconia and LD FCRs, whereas RMC restorations show no significant change. Appropriate repair protocols can restore or improve retention, potentially exceeding original values. Limited evidence suggests that effective sealing is achievable with appropriate materials. However, well-designed and in-vivo researches are needed to provide more detailed clinical guidance. CLINICAL SIGNIFICANCE: When performing endodontic access through retained FCRs, reduced fracture resistance must be carefully considered for zirconia and LD restorations, while RMC restorations may be exempt from this concern. Loss of retention with access can be restored after repair. Surface pretreatment and flowable resin liners help decrease microleakage.

Humans

The use of diode laser and scalpel blade in stage-two dental implant surgery: a comparative study.

OBJECTIVE: The use of lasers in dental implant procedures raises questions regarding the preservation of keratinized tissues and implant outcomes. This study aimed to compare the clinical effects (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing) of diode lasers and scalpels used during stage-two dental implant surgery. METHOD AND MATERIALS: A prospective randomized clinical trial with a 1:1 allocation ratio was conducted. The study included 30 patients, each with a single, fully osseointegrated implant. Patients were categorized into two groups. The study group underwent stage-two implant surgery using a 970-nm diode laser. In the control group, implants were exposed using a conventional surgical blade. A comparison between the diode laser and conventional scalpel groups was made based on clinical outcomes (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing). Data were analyzed using a paired t test. RESULTS: Pain intensity significantly decreased from immediate postoperative to 7 days in both scalpel (49.87 &#xb1; 6.78, t = 28.48, df = 14, P .001) and diode laser (7.67 &#xb1; 7.58, t = 3.91, df = 14, P = .002) groups. Immediately after surgery, pain scores were significantly higher in the scalpel group compared with the diode laser group (94.53 &#xb1; 4.45 vs 46.93 &#xb1; 5.85, t = 25.076, df = 26.151, P .001). Although pain decreased in both groups by day 7, the scalpel group continued to exhibit significantly greater pain (44.67 &#xb1; 5.96 vs 39.27 &#xb1; 3.73, t = 2.974, df = 23.513, P = .007). Impression time (P = .231) and gingival keratinized tissue (P = .736) did not differ significantly between the scalpel and diode laser approaches. At week 6, the scalpel group exhibited a significantly higher mean peri-implant bleeding index (2.60 &#xb1; 0.507) compared with the laser group (0.07 &#xb1; 0.258, P .001). However, after 12 weeks, no significant difference was observed (1.58 &#xb1; 0.19 vs 1.55 &#xb1; 0.21, P = .748). Laser surgery produced significantly better early wound healing at all intervals (P .001), while intraoperative bleeding was more common with the scalpel technique than with the diode laser (100.0% vs 66.7%, P = .042). CONCLUSION: Compared with the scalpel method, the diode laser method resulted in a significant reduction in pain intensity, improved wound healing, and less peri-implant bleeding during the stage-two dental implant surgery.

Humans

Autologous bone grafts versus alloplastic implants for orbital floor reconstruction: a systematic review and meta-analysis.

PURPOSE: The choice of reconstructive material for orbital floor fractures remains a subject of debate. While autologous bone has historically been considered the "gold standard," alloplastic implants offer potential advantages in reducing surgical morbidity. This meta-analysis aimed to compare the safety and efficacy of autologous bone grafts versus alloplastic implants in orbital floor reconstruction. METHODS: A systematic review was conducted in accordance with PRISMA guidelines (PROSPERO: CRD420251140583). Electronic databases (PubMed, Scopus, Web of Science, Cochrane Library) were searched from inception to August 2025. Randomized controlled trials and comparative cohort studies evaluating functional outcomes (diplopia, enophthalmos) and complications (ectropion, infection, malposition) were included. Data were synthesized using a random-effects model, with risk ratios (RR) and 95% confidence intervals (CI) calculated. RESULTS: Twenty studies comprising 2,119 patients were included. Alloplastic implants demonstrated statistically significant superiority in periocular safety, with a reduced risk of postoperative ectropion compared to autologous grafts (RR&#x2009;=&#x2009;2.245; p&#x2009;=&#x2009;0.020). In an exploratory sensitivity analysis excluding one outlier study, autologous grafts were associated with a significantly higher risk of implant malposition (RR&#x2009;=&#x2009;2.074; p&#x2009;=&#x2009;0.004). Autologous reconstruction was associated with a strong trend toward increased postoperative pain (p&#x2009;=&#x2009;0.052) and inherent donor-site morbidity. No statistically significant differences were observed regarding infection (p&#x2009;=&#x2009;0.402), enophthalmos (p&#x2009;=&#x2009;0.201), or diplopia (p&#x2009;=&#x2009;0.221). CONCLUSION: Alloplastic implants were associated with a lower risk of ectropion and implant malposition, with functional outcomes statistically comparable to autologous bone. Given the elimination of donor-site morbidity, alloplastic biomaterials represent a safe and effective alternative for orbital floor reconstruction; however, the predominance of retrospective, heterogeneous studies in the current evidence base means these findings should inform, rather than replace, individualized surgical decision-making pending further high-quality randomized trials.

Humans

The Soundtrack of Everyday Life: Real-world Music Listening Habits of Adult Cochlear Implant Users.

OBJECTIVE: Characterize real-world patterns of music listening and reward sensitivity among adult cochlear implant (CI) users compared with normal-hearing (NH) listeners. STUDY DESIGN: Cross-sectional observational study. SETTING: Online. PATIENTS: Adults (&#x2265;18&#xa0;y) with a CI or NH who used a music-streaming platform as their primary listening method. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Objective measures included platform-derived audio features (acousticness, danceability, energy, tempo, and valence), listening volume, unique-song ratio, and decade preferences. Self-reported measures included listening habits and the Barcelona Music Reward Questionnaire (BMRQ). Group comparisons used ANCOVAs and mixed-effect models adjusting for age and gender; within-CI analyses compared prelingual versus postlingual deafness. RESULTS: Among 16 CI users (69% male, 39.0&#xb1;15.6&#xa0;y) and 29 NH listeners (38% male, 32.2&#xb1;11.3&#xa0;y), CI users demonstrated a higher unique-song ratio (&#x3b2;=-0.157, CI as reference; 95%CI [-0.281, -0.034]; P =0.014) and stronger preference for older music (Pillai trace=0.537; F8,35 =5.07; P <0.001), adjusting for age. No significant group differences were observed in weekly listening time, listening volume, audio features, or BMRQ scores (total and subscores). Equivalence was confirmed for Emotion Evocation and Sensory-Motor subscales. There were no statistically significant differences in listening environments after Holm correction. No statistically detectable differences were observed between pre- and postlingually deafened CI users. CONCLUSIONS: Musically active CI users showed no significant differences in listening volume or overall music-reward sensitivity compared with NH peers, but demonstrated higher unique-song ratios and a bias toward older music. Findings highlight the value of ecologically valid data in understanding real-world music experiences among CI users.

Adult

Evaluation of intravenous sedation in dental implant surgeries: A prospective cohort study.

PURPOSE: This study aimed to evaluate the impact of intravenous sedation on patient-centered outcomes during implant and bone augmentation surgeries. METHOD: A prospective observational cohort study included 40 patients undergoing placement of &#x2265;3 implants, with or without bone augmentation. Patients underwent surgery under either intravenous sedation (n = 20) or local anesthesia alone (n = 20), according to routine clinical decision-making and patient preference. The sedation group received intravenous sedation with a multimodal regimen comprising remimazolam, dexmedetomidine, alfentanil, and low-dose esketamine, whereas the control group received local anesthesia only. Patient-reported outcome measures, hemodynamic parameters (SBP, DBP, HR, SpO2), postoperative pain (0-10 scale), and OHRQoL (OHIP-14) were recorded from baseline through 7 days post-surgery. RESULTS: Intravenous sedation was associated with significantly lower intraoperative pain (0.5 [IQR: 0&#x223c;2.75] vs. 3.25 &#xb1; 2.40, p = 0.003), anxiety (1 [IQR: 0&#x223c;2.75] vs. 4 [IQR: 3&#x223c;6], p = 0.001), and experienced discomfort (2 [IQR: 1&#x223c;3.75] vs. 4.15 &#xb1; 2.16, p = 0.016), and shortened perceived treatment duration (2.90 &#xb1; 2.34 vs. 5 [IQR: 4&#x223c;5], p = 0.020). Early postoperative pain was lower in the sedation group from Days 1-4 (p = 0.003-0.010). Hemodynamic parameters were more stable under sedation, with lower SBP (116.42 &#xb1; 13.32 vs. 144.11 &#xb1; 17.42 mmHg, p < 0.001), DBP (73.21 &#xb1; 10.28 vs. 82.37 &#xb1; 11.03 mmHg, p = 0.012), and HR (71.00 [IQR: 62.50&#x223c;79.25] vs. 85.00 &#xb1; 10.72 bpm, p = 0.021). OHRQoL scores favored the sedation group in swallowing, diet, malaise, and daily activities, particularly during the first three postoperative days (p=0.006-0.040). CONCLUSION: Intravenous sedation may enhance the patient experience during implant and/or bone augmentation procedures by reducing intraoperative pain and anxiety, improving hemodynamic stability, and promoting better early-postoperative recovery and OHRQoL. These findings suggest that intravenous sedation provides a safe and effective alternative for implant dentistry surgery, particularly for anxious or pain-sensitive individuals.

Humans

Effect of Bariatric Surgery on Improvement of Retinal Microvasculature in Patients With Obesity: A Systematic Review and Meta-Analysis.

Obesity is associated with adverse retinal microvascular changes, including narrower central retinal arteriolar equivalent (CRAE), wider central retinal venular equivalent (CRVE) and lower arteriovenous ratio (AVR). Although bariatric surgery improves cardiometabolic risk, its effect on retinal microvascular calibre remains uncertain. We systematically searched the Cochrane Library, PubMed, ScienceDirect and Scopus up to June 2026. Prospective cohort studies reporting CRAE, CRVE or AVR before and after bariatric surgery in patients with obesity were included. Risk of bias was assessed using the Newcastle-Ottawa Scale. Pooled mean differences (MD) with 95% confidence intervals (CI) were calculated using a random-effects model. Eight prospective cohort studies including 283 patients were included. Seven studies contributed to the CRAE and CRVE analyses, and seven contributed to the AVR analysis. Bariatric surgery was associated with a significant increase in CRAE (MD&#x2009;=&#x2009;+4.02&#x2009;&#x3bc;m, CI [0.26-7.78], p&#x2009;=&#x2009;0.04). Sensitivity analysis excluding one study showed a stronger and more consistent effect (MD&#x2009;=&#x2009;+5.41&#x2009;&#x3bc;m, CI [4.59-6.22], p&#x2009;<&#x2009;0.01). CRVE significantly decreased after surgery (MD&#x2009;=&#x2009;-6.75&#x2009;&#x3bc;m, CI [-7.42 to -6.07], p&#x2009;<&#x2009;0.01), while AVR significantly increased (MD&#x2009;=&#x2009;+0.03, CI [0.02-0.05], p&#x2009;<&#x2009;0.01). Sensitivity analyses suggested that the direction of effect was generally robust, although between-study heterogeneity was present. Bariatric surgery may be associated with favourable retinal microvascular changes in patients with obesity, reflected by increased CRAE and AVR and decreased CRVE.

Humans

Influence of nicotine on protein expression around hydrophilic osseointegrated implants: A proteomic study in male rats.

OBJECTIVE: To ensure the success of dental implant treatment, various factors must be considered, including osseointegration and systemic conditions. There is evidence in the literature that smokers may exhibit alterations in tissue healing, which can compromise the success of implant rehabilitation. Therefore, this study aimed to investigate the influence of nicotine on the protein profile of bone tissue around hydrophilic implants during the osseointegration process in rats. DESIGN: Bone tissue samples from the control and nicotine groups (n&#x202f;=&#x202f;3 per group) were subjected to protein extraction, mass spectrometry, and bioinformatic analyses. Protein identification was performed using Proteome Discoverer 2.1 software and the SEQUEST algorithm, and the protein data were compared with those of a protein database of Rattus norvegicus obtained from UniProt. RESULTS: A total of 740 proteins were detected in both the control group and the nicotine-exposed group. Among them, the proteins biglycan, periostin and histone H4 were highlighted because of their higher abundance in the healthy implant group, while they were reduced in the nicotine-exposed group. CONCLUSIONS: Nicotine has the potential to alter the protein profile of bone tissue around hydrophilic implants during osseointegration, which may impair tissue remodeling and healing.

Animals

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Proteomic insights into the immunomodulatory effects of Ca/Sr co-doped sol-gel coatings for titanium implants.

Ionic functionalization of biomaterial coatings has emerged as a powerful strategy to regulate early host responses at the implant interface. However, how combined Ca/Sr incorporation governs the adsorbed proteome and downstream immune signaling remains poorly understood. This study analyses, employing in vitro tests and proteomics, the effect of adding Sr and Ca to Si-based coatings designed to bioactivate Ti implants. Hybrid Si-based coatings were synthesized by the sol-gel route with a fixed Ca content (0.5&#x202f;wt%) and increasing Sr contents (0.5, 1.0, 1.5&#x202f;wt%), and their physicochemical properties, ion release kinetics, and hydrolytic stability were characterized. The coatings remained highly crosslinked despite Ca/Sr incorporation, whereas the highest Sr content increased hydrolytic degradation to around 70% after 56 days. Proteomic analysis identified 183 adsorbed proteins, of which 56 were differentially adsorbed on Ca/Sr-coatings, mainly associated with immune and coagulation pathways. In vitro, RAW 264.7 showed increased gene expression of TNF-&#x3b1; and TGF-&#x3b2;; with an enhanced TNF-&#x3b1; secretion by the addition of Ca and Sr. In parallel, MC3T3-E1 indicated that Ca/Sr-coatings were not cytotoxic and did not impair cell proliferation. However, ALP activity was reduced in the co-doped groups, indicating that the immunomodulatory effects induced by Ca/Sr incorporation were not accompanied by enhanced early osteogenic differentiation. The Ca/Sr combination induced alterations in the adsorption of immune-related proteins, which correlated with the in vitro findings. The deeper insight into how Ca/Sr mixtures modulate protein adsorption on biomaterial surfaces may be key to understanding the immunomodulatory capacity of these bioactive cations.

Animals