Search PubMedSearch

SEARCH · Search PubMed

Results for “prostate‐specific membrane antigen”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

872 records · Page 18Linked to original sources

The Role of Artificial Intelligence Combined With Digital Cholangioscopy for Indeterminant and Malignant Biliary Strictures: A Systematic Review and Meta-analysis.

BACKGROUND: Current endoscopic retrograde cholangiopancreatography (ERCP) and cholangioscopic-based diagnostic sampling for indeterminant biliary strictures remain suboptimal. Artificial intelligence (AI)-based algorithms by means of computer vision in machine learning have been applied to cholangioscopy in an effort to improve diagnostic yield. The aim of this study was to perform a systematic review and meta-analysis to evaluate the diagnostic performance of AI-based diagnostic performance of AI-associated cholangioscopic diagnosis of indeterminant or malignant biliary strictures. METHODS: Individualized searches were developed in accordance with PRISMA and MOOSE guidelines, and meta-analysis according to Cochrane Diagnostic Test Accuracy working group methodology. A bivariate model was used to compute pooled sensitivity and specificity, likelihood ratio, diagnostic odds ratio, and summary receiver operating characteristics curve (SROC). RESULTS: Five studies (n=675 lesions; a total of 2,685,674 cholangioscopic images) were included. All but one study analyzed a deep learning AI-based system using a convoluted neural network (CNN) with an average image processing speed of 30 to 60 frames per second. The pooled sensitivity and specificity were 95% (95% CI: 85-98) and 88% (95% CI: 76-94), with a diagnostic accuracy (SROC) of 97% (95% CI: 95-98). Sensitivity analysis of CNN studies (4 studies, 538 patients) demonstrated a pooled sensitivity, specificity, and accuracy (SROC) of 95% (95% CI: 82-99), 88% (95% CI: 72-95), and 97% (95% CI: 95-98), respectively. CONCLUSIONS: Artificial intelligence-based machine learning of cholangioscopy images appears to be a promising modality for the diagnosis of indeterminant and malignant biliary strictures.

Humans

Diagnostic performance of panfungal PCR on tissue specimens for the diagnosis of invasive fungal diseases: a systematic review and meta-analysis of the Fungal PCR Initiative (FPCRI).

UNLABELLED: Invasive fungal diseases are difficult to diagnose because of the limited sensitivity of culture. Panfungal PCR amplicon sequencing assays (targeting ribosomal RNA, such as 18S, 28S, ITS) are recommended for fungal identification in histopathology samples showing fungal elements. However, data describing its overall performance and consistency are lacking. This systematic literature review and meta-analysis assessed the performance of panfungal PCR on formalin-fixed paraffin-embedded (FFPE) and non-fixed (fresh or frozen) tissue samples. A systematic literature search was performed to include studies reporting the use of panfungal PCR for fungal identification in FFPE or non-fixed tissue samples. PCR sensitivity and specificity were assessed using the reference standard of histopathology showing fungal elements. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled estimates were obtained using random-effects meta-analysis. Twenty-eight studies were included. In FFPE samples (18 studies, 852 samples), sensitivity and specificity were 75.4% (95% confidence interval [CI], 59.2-86.6) and 93.5% (70.2-98.9), respectively. Sensitivity in non-fixed samples (13 studies, 207 samples) was 86.5% (74.7-93.3), while specificity could not be assessed (insufficient data). Comparative analyses showed a significantly higher sensitivity of panfungal PCR over culture (88.2%; 76-94.7 vs 52.2%; 39-65, P = 0.001). Sub-analyses could not demonstrate the superiority of one PCR target over another due to limited data. Panfungal PCR exhibited adequate sensitivity and good specificity in FFPE samples. Sensitivity was even higher in non-fixed samples and largely superior to culture. Nevertheless, large interstudy variability was observed, warranting interlaboratory studies to define the optimal PCR target and standardized protocols. IMPORTANCE: Invasive fungal diseases are difficult to diagnose because of the low sensitivity of culture. Panfungal PCRs are widely used for fungal identification in tissue specimens but suffer from heterogeneous procedures and performance. This meta-analysis shows an acceptable sensitivity (75.4% and 86.5% in fixed and non-fixed samples, respectively) and good specificity (93.5%) of panfungal PCR, supporting its use, not only on histopathology-positive fixed samples but also in non-fixed samples concomitantly with other diagnostic tools (cultures and fungal-specific PCRs if available). These results provide a strong basis for further standardization of panfungal PCR techniques via interlaboratory assays to assess reproducibility and optimize analytical protocols. CLINICAL TRIALS: This study is registered with PROSPERO as CRD42023461148.

Humans

Parent-of-origin effects on allelic expression bias in interspecific poplar hybrids.

In hybrid plants, phenotypic outcomes are governed by interactions between the two parental genomes. However, the mechanisms underlying the interplay of divergent regulatory networks from these genomes remain poorly understood. In this study, we compared gene-level and allele-specific expression patterns, as well as differentially enriched pathways between F₁ and complex backcross (CBC) lines derived from a natural interspecific hybrid population of Populus fremontii (Pf) and P. angustifolia (Pa). Metabolic differences between Pf and Pa which exhibit low and high levels respectively of phenylpropanoid-derived condensed tannins were leveraged. Using individualized transcriptome references, differential expression and clustering analyses revealed CBC-biased and F₁-biased expression for genes involved in phenylpropanoid metabolism and photosynthesis, respectively. Biased expression of these genes at the allele level was also observed in F1. At the whole-transcriptome level, Pa-biased genes predominated in F₁ hybrids, and Pa alleles displayed more conserved expression patterns than Pf alleles across examined samples. Further analyses indicated that allelic expression bias was significantly associated with parental origin, which could be driven by sequence variations in cis-regulatory elements and differences in CpG island length. Our findings demonstrate strong parent-of-origin effects on divergent regulatory networks governing gene expression in poplar hybrids and provide clues for strategic parental selection tailored to specific metabolic pathways of interest.

cis-regulation

Diagnostic performance of machine learning models for malignant and non-malignant pleural effusion: Systematic review and meta-analysis.

BACKGROUND: Accurately distinguishing malignant pleural effusion (MPE) from non-malignant pleural effusion is clinically important, but the generalisability and methodological quality of machine-learning (ML) models remain uncertain. METHODS: We searched eight databases to 23 April 2026. Diagnostic performance was pooled using random-effects and Reitsma bivariate models, and study quality was assessed using PROBAST+AI. RESULTS: Forty-two studies were included; 17 contributed to the AUC meta-analysis and 14 to the bivariate analysis. The pooled AUC was 0.90 (95 % CI 0.85-0.94; 95 % prediction interval 0.62-0.98), with sensitivity of 0.80 (95 % CI 0.77-0.83) and specificity of 0.87 (95 % CI 0.79-0.92). Only nine studies reported external, temporal or independent validation. Externally validated studies had a lower pooled AUC than studies without external validation (0.83 vs 0.92), with lower specificity observed in the two externally validated studies contributing sensitivity and specificity data. All 42 development assessments had high overall quality concerns, and all 42 model evaluations were judged at high risk of bias. CONCLUSIONS: ML models showed good apparent accuracy for distinguishing MPE from non-MPE, but the evidence was limited by substantial heterogeneity, high risk of bias and scarce external validation. The pooled estimates reflect the average performance of different selected models rather than the expected accuracy of a single clinical test. ML models should be regarded as adjuncts to existing diagnostic pathways until they are confirmed by rigorous multicentre prospective external validation and clinical-impact studies.

Humans

Assessment of atypical glandular cell interpretation in Pap tests using the Hologic Genius Digital Diagnostics System.

Atypical glandular cells (AGC) are a diagnostic challenge. The aim of this study was to evaluate the efficacy and diagnostic performance of AGC detection on the Hologic Genius Digital Diagnostics System (HGDDS). A retrospective analysis of 451 ThinPrep Pap cases was conducted, including 207 cases of AGC, 27 cases of high-grade squamous intraepithelial lesion (HSIL), 25 cases of low-grade squamous intraepithelial lesion (LSIL), and 192 benign cases. All AGC cases had follow-up histologic diagnoses, with 66 cases subsequently diagnosed as adenocarcinoma. The slides were randomized, scanned, and analyzed by the HGDDS. Patient age and HPV test results were provided to reviewers, an experienced cytologist, who screened the cases, followed by two cytopathologists who independently examined the cases on the HGDDS. Diagnostic concordance between the two cytopathologists indicated strong agreement (κ = 0.829). Sensitivity of AGC on Papanicolaou (Pap) tests for adenocarcinoma detection on HGDDS was 98.5% and 95.5%, respectively, comparable to the original ThinPrep interpretation (OTPI). Specificity for adenocarcinoma detection was significantly higher (84.6% and 85.6%) with the HGDDS than 27.7% with OTPI. Overall, the diagnostic performance for AGC/HSIL interpretation to detect CIN2/3/adenocarcinoma appeared to have improved with HGDDS compared with OTPI, particularly for specificity and positive predictive value (PPV). This is the first study evaluating AGC diagnosis using the HGDDS. The findings demonstrate that the sensitivity of adenocarcinoma detection as AGC on HGDDS is comparable to the ThinPrep Imaging System, but the specificity and PPV are improved. This suggests the potential of artificial intelligence to augment the performance of cervical cancer screening.

Humans

Cre-loaded integrase-defective lentiviral vectors for targeted cassette exchange in CHO cells.

Genome-modifying enzymes, such as recombinases and CRISPR-associated nucleases, enable targeted gene insertion when delivered transiently to minimize off-target effects. Precise genome engineering requires controlled enzyme activity, as well as efficient donor DNA transfer. Integrase-defective lentiviral vectors (IDLVs) provide a promising platform for transient episomal DNA transfer; however, their integration efficiency depends on complementary genome-targeting strategies. Here, we engineered Cre-loaded IDLVs (Cre-IDLVs) that co-package lentiviral vector genomes together with bioactive Cre recombinase. Cre was inserted into the Gag region of an integrase-defective gag-pol construct, allowing for efficient encapsidation and protease-mediated release during virion maturation without compromising the viral titer. The resulting particles carried donor cassettes flanked by heterospecific loxP sites. When applied to CHO founder cells harboring compatible genomic loxP landing pads, Cre-IDLVs efficiently mediated recombination-mediated cassette exchange, producing the highest number of G418-resistant colonies among the plasmid ratios tested. Genomic PCR and sequencing confirmed precise locus-specific insertion without detectable random integration in the analyzed clones. These findings establish Cre-IDLVs as a streamlined dual-delivery platform that couples transient recombinase activity with episomal donor DNA transfer. This hybrid lentiviral strategy provides a programmable approach for controlled and site-specific genome modification in mammalian cells.

Integrases

Can ChatGPT Replace Human Clinical Coders? A Comparative Study in Otology Billing.

OBJECTIVE: Evaluate the utility of the large language model (LLM), ChatGPT, for the analysis of operative notes and the generation of Current Procedural Terminology (CPT) codes in comparison to human clinical coders. STUDY DESIGN: CPT billing codes assigned by ChatGPT were compared to existing billing data. Otology practice within a tertiary academic center. METHODS: About 191 operative notes from a single surgeon (9/2022-10/2023) were analyzed. ChatGPT-3.5 and 4 models were prompted for CPT codes based on operative notes. Assessment included determining exact and partial match rates, sensitivity and specificity for targeted procedures, and work Relative Value Units (wRVU) differences between ChatGPT-generated and human-assigned codes. RESULTS: ChatGPT-3.5 achieved exact matches in 22% of cases and partial matches in 32%, while ChatGPT-4 achieved 14% exact and 33% partial matches. When cochlear implantation (CI) was excluded, performance dropped significantly. For CI, ChatGPT-3.5 demonstrated a sensitivity of 94% and specificity of 90%, while ChatGPT-4 showed a sensitivity of 96% and specificity of 92%. In contrast, performance on cartilage grafting was poor, with sensitivities of 4.2% for ChatGPT-3.5 and 0% for ChatGPT-4. ChatGPT-3.5 and 4 showed moderate CPT code matching accuracy among themselves, with slight agreement to human coders. Both models tended to underbill for wRVUs compared to human coders, with significant differences in the values generated. CONCLUSION: This study assessed ChatGPT's effectiveness in automating CPT code assignment for otologic surgeries. While the models achieved high sensitivity values for assigning codes related to cochlear implantation, both models struggled with complex cases, failed to apply modifiers, and often assigned fewer wRVUs. The findings highlight ChatGPT's potential in medical billing but indicate a need for further refinement.

Humans

MIC-based tuberculosis drug susceptibility testing using Sensititre MYCOTB: a diagnostic accuracy meta-analysis.

Accurate drug susceptibility testing (DST) is crucial for designing effective regimens for multidrug-resistant (MDR) and pre-extensively drug-resistant tuberculosis (pre-XDR TB). Sensititre MYCOTB enables simultaneous determination of minimum inhibitory concentrations (MICs) for multiple drugs, but its diagnostic performance varies across studies. This meta-analysis evaluated the diagnostic performance of Sensititre MYCOTB for key MDR and pre-XDR TB drugs. The protocol was registered in PROSPERO (CRD420251230599). PubMed, Cochrane, Google Scholar, Scopus, ONOS, Web of Science, ScienceDirect, and registries were systematically searched for studies published between 2010 and 2025. Studies comparing the Sensititre MYCOTB with reference DST for Mycobacterium tuberculosis complex (MTBC) were included. Bias assessment and pooled diagnostic accuracy estimates were generated. Fourteen studies, including 1,728 isolates, were analyzed. Rifampicin and isoniazid demonstrated high sensitivity (0.976 [95% CI: 0.94-0.99] and 0.977 [95% CI: 0.95-0.99]) and specificity (0.958 [95% CI: 0.84-0.98] and 0.957 [95% CI: 0.83-0.99], respectively) with low heterogeneity. Amikacin, kanamycin, and ofloxacin demonstrate good diagnostic accuracy, with high specificity (>0.98 [95% CI]). Moderate diagnostic accuracy was observed for ethambutol, streptomycin, ethionamide, and rifabutin. Cycloserine, moxifloxacin, and para-aminosalicylic acid showed inconsistent performance despite excellent specificity (>0.97 [95% CI]). Sensitivity analysis partially improved pooled sensitivity for moxifloxacin 0.801 (95% CI: 0.585-0.924) and para-aminosalicylic acid 0.76 (95% CI: 0.518-0.894), whereas cycloserine remained at 0.436 (95% CI: 0.190-0.725), although heterogeneity persisted. Sensititre MYCOTB DST demonstrates high diagnostic accuracy for MDR-TB and pre-XDR-TB drugs, while caution is required with cycloserine, moxifloxacin, and para-aminosalicylic acid. These findings support the integration of MIC-based testing into clinical decision-making.

Microbial Sensitivity Tests

Webcam-Based Real-Time Visual Feedback During Baduanjin Practice in Older Adults: 6-Week Pilot Randomized Study.

BACKGROUND: Baduanjin qigong is a traditional mind-body exercise used to support balance and physical health in older adults. Age-related changes in proprioception may make accurate self-directed performance difficult without external guidance. OBJECTIVE: The aim of this study is to explore whether webcam-based real-time visual feedback delivered during supervised laboratory sessions was associated with differences in webcam-derived 2D pose discrepancy and movement consistency during Baduanjin practice in older adults. METHODS: A total of 31 older adults were enrolled, and 28 participants with complete analyzable records were included in this complete-case dataset (feedback group, n=14; nonfeedback group, n=14). All sessions were conducted face-to-face in a supervised motion-analysis laboratory. Weekly 2D pose-discrepancy values were analyzed using a linear mixed-effects model with fixed effects for group, categorical week, and the group-by-week interaction and a participant-specific random intercept. Joint- and movement-specific participant-level 6-week means were analyzed exploratorily using Welch independent-samples t tests. Holm correction was applied across 24 exploratory contrasts (6 week-specific, 8 joint-specific, and 10 movement-specific comparisons), and Hedges g and 95% CIs were reported. Participant-specific weekly slopes and within-participant variability were additionally examined to directly assess longitudinal error drift. RESULTS: The linear mixed-effects model showed no significant group-by-week interaction (Wald χ25=1.09; P=.96) and no significant overall week effect (Wald χ25=6.40; P=.27). Averaged across 6 weeks, the feedback group had an estimated mean 2D pose discrepancy 1.20° lower than the nonfeedback group (95% CI -2.38° to -0.02°; P=.046), although this marginal pilot finding was sensitive to an analytic approach. No week-specific contrast remained significant after Holm adjustment. Nominal right elbow, right shoulder, and right knee differences did not survive global Holm correction. Form 3 showed a lower mean discrepancy in the feedback group (mean difference -3.70°, 95% CI -5.86° to -1.54°; Hedges g=-1.30; unadjusted P=.002; Holm-adjusted P=.04). Direct analyses of participant-specific slopes and within-participant SDs did not support a significant between-group difference in longitudinal error drift. CONCLUSIONS: In this small exploratory pilot study conducted under supervised laboratory conditions, the 6-week trajectories did not differ significantly between groups. A marginally lower average 2D pose discrepancy was observed in the feedback group across the 6 weeks, but no individual week- or joint-specific comparison remained significant after multiplicity adjustment. Form 3 was the only exploratory contrast that remained significant after global Holm correction. Direct longitudinal analyses did not demonstrate prevention of error drift. Larger studies using validated reference measurements, prespecified outcomes, and adequately powered longitudinal designs are required.

Humans

Comparison of black carbon measurements using filter-specific reference transmittance to those using lab blanks or an average of unloaded filters.

Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). We analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial to assess the influence that different methods of I0 estimations have on eBC measures. We compared eBC measurements using filter-specific I0 values (Method 1) to those using three other methods of I0 estimation: the lab blank scan from a given session (Method 2), the average of all pre-sample filter scans (Method 3), and the average of all lab blank filter scans (Method 4). We assessed the agreement between Method 1 and the alternative methods using Bland-Altman analysis. We also assessed the relationship between Method 1 and the alternative methods across the complete measurement range and after stratifying exposure data into quartiles according to Method 1 eBC exposures. The mean (SD) personal eBC exposure for Method 1 was 7.8 μg/m3 (5.9), and exposures ranged from 1.3 to 46.8 μg/m3. Compared to Method 1, eBC using Methods 2, 3, and 4 were higher by 0.7 μg/m3, 0.1 μg/m3, and 0.7 μg/m3, respectively. The performances of linear regression models between Method 1 and all other methods were moderate to strong (R2 range: 0.42-0.93) in the second, third, and fourth quartiles; however, the models in the first quartile (eBC range: 1.3-2.9 μg/m3) performed poorly (R2 = 0.25-0.26), with error approximately 25% of the mean. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.Implications: Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). To assess the influence that different methods of I0 estimations have on eBC measures, we analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.

Soot

Divergent responses of the gill, hepatopancreas, and eyestalk to acute alkalinity stress in Penaeus vannamei: Osmoregulatory compromise, metabolic trade-off, and endocrine disruption.

The expansion of aquaculture into inland saline-alkali waters is constrained by high carbonate alkalinity (CA), a severe environmental stressor for crustaceans. However, the systemic molecular mechanisms underlying its lethal toxicity remain poorly understood. In this study, we employed a comparative transcriptomic approach to investigate the tissue-specific responses of Pacific white shrimp, Penaeus vannamei, under acute lethal stress (48 h-LC50). We focused on three functionally distinct organs: the gill, hepatopancreas, and eyestalk. The results revealed a systemic but highly tissue-specific transcriptomic response. The gill, as the primary interface, exhibited severe structural impairment and critical failure of osmoregulation, highlighted by the significant downregulation of delta-1-pyrroline-5-carboxylate synthetase (P5CS). In contrast, the hepatopancreas initiates a profound metabolic trade-off, sacrificing growth-related pathways to bolster a robust antioxidant defense system, as evidenced by the activation of sulfur metabolism and high protein turnover. The eyestalk displayed a striking disconnect between hyperactivated stress signaling pathways (e.g., mTOR/FoxO) and the collapse of its protein secretory machinery, marked by the suppression of the ER translocon component Sec61. Collectively, our findings suggest that lethal alkalinity toxicity in P. vannamei results from systemic collapse driven by a complex interplay of osmoregulatory failure, metabolic trade-offs, and endocrine disruption. This study provides a comprehensive molecular snapshot of an organism at its physiological limit, offering novel insights into the adaptive strategies and ultimate tolerance boundaries of crustaceans in extreme environments.

Animals

HPV circulating tumor DNA as a potential prognostic and predictive biomarker in head and neck squamous cell carcinoma: a systematic review.

PURPOSE: Human papillomavirus circulating tumor DNA (HPVctDNA) has emerged as a promising prognostic biomarker in HPV-related head and neck squamous cell carcinoma (HNSCC). This systematic review aimed to synthesize current evidence on the diagnostic accuracy and prognostic value of HPVctDNA in HNSCC management. MATERIAL/METHODS: We systematically reviewed a PubMed-indexed database of studies published between January 2012 and September 2025. Eligible studies were assessed for design, primary tumor site and stage, treatment modality, HPVctDNA detection method, diagnostic accuracy (sensitivity and specificity), and reported clinical endpoints. Descriptive syntheses were performed; sensitivity and specificity were standardized to proportions and summarized as median values per group. RESULTS: A total of 60 studies, including 8,234 patients were analyzed, of which 41 (68.3%) focused exclusively on oropharyngeal squamous cell carcinoma (OPSCC) and 17 (28.3%) included mixed HPV-related HNSCC subsites and HPV-positive cancers of unknown primary. The median follow-up across the included studies was 23 months. Among the included studies, 19 were retrospective (31.7%) and 33 were prospective (55.0%), with a small proportion of cross-sectional and randomized clinical trials. Overall, 40 (66.7%) evaluated the role of HPVctDNA in a curative setting. Plasma was the most common sample type, analyzed in 55 studies (91.7%), while 5 studies also included saliva. Detection methods varied: 40 employed droplet digital PCR (ddPCR), 16 used quantitative PCR (qPCR) and 4 applied NGS-based assays. Most of these studies (38, 63.3%) evaluated the prognostic utility of HPVctDNA, while only 4 (6.7%) assessed HPVctDNA in a screening or diagnostic setting. Regarding diagnostic accuracy, the median sensitivity across evaluable studies was 91.1%, while the median specificity was 99.4%. In OPSCC-only cohorts, the median sensitivity and specificity were 89.4% and 99.4%, respectively. Dynamic changes in HPVctDNA levels during or after treatment were consistently associated with outcomes: clearance or sustained negativity correlated with higher response rates, improved progression-free survival and overall survival, while persistent positivity or increasing levels predicted disease progression and recurrence. CONCLUSIONS: HPVctDNA demonstrates high diagnostic and prognostic accuracy in HPV-related HNSCC, especially OPSCC, supporting its use for prognosis, treatment monitoring and early detection of recurrence. However, prospective interventional studies are still required to demonstrate that HPVctDNA-guided treatment decisions improve clinical outcomes before routine implementation.

Humans

Quantitative susceptibility mapping in neurodegenerative diseases: An umbrella review of iron-related biomarkers and mechanisms.

Pathological iron accumulation is a common pathophysiological hallmark across multiple neurodegenerative diseases (NDDs), motivating the need for accurate, non-invasive quantification methods. Quantitative susceptibility mapping (QSM) is an advanced magnetic resonance imaging (MRI) technique that enables in vivo measurement of tissue magnetic susceptibility (χ), providing a sensitive proxy for iron content. This umbrella review systematically evaluates the diagnostic accuracy, clinical correlations, and distinct iron distribution patterns of QSM in major NDDs, such as Parkinson's disease (PD), Alzheimer's disease (AD), amyotrophic lateral sclerosis (ALS), and atypical Parkinsonism. We included 15 (13/15 were rated Low or Critically Low on AMSTAR 2) systematic reviews and meta-analyses (through July 15, 2026); however, the findings should be interpreted cautiously because of heterogeneity and the low methodological quality. A Corrected Covered Area (CCA) analysis demonstrated only slight overlap of primary studies across the included reviews (CCA = 5.42%). Collectively, the evidence indicates that QSM provides comparable or higher diagnostic sensitivity and reliability than conventional R2* and SWI techniques, particularly for deep gray matter structures. The findings support significant iron overload in the substantia nigra, particularly in the pars compacta, as a robust biomarker for PD that correlates with motor severity and disease duration. Furthermore, regional iron profiling in the basal ganglia is critical for differential diagnosis; specifically, elevated χ in the putamen and globus pallidus effectively distinguishes multiple system atrophy and progressive supranuclear palsy from idiopathic PD. Distinctively, AD and ALS exhibit specific χ alterations in the thalamus, motor cortex, and hippocampus, reflecting divergent iron-related pathophysiological mechanisms, which correlate with cognitive impairment and upper motor neuron signs. Overall, QSM shows diagnostic promise and offers mechanistic insights into iron-related neurodegenerative processes.

Humans

Divergent evolutionary strategies in spider venoms: A comparative proteomic profiling of four sympatric species from Yunnan.

Spider venoms comprise complex cocktails of bioactive molecules evolved for predation and defense, representing a valuable resource for biological research and pharmaceutical discovery. In this study, we performed a systematic analysis of venom gland extracts from four common spider species indigenous to Yunnan, China: Agelena limbata, Hippasa lycosina, Lycosa grahami, and Sinopoda pengi. Using an integrated transcriptomic and proteomic targeted profiling approach, we successfully annotated 141 distinct toxins. Comparative analysis revealed significant interspecific heterogeneity, suggesting distinct evolutionary trajectories and "weapon system economics." Both A. limbata and L. grahami exhibited a "peptide-dominant" profile anchored by neurotoxic peptides and isomerases, optimized for rapid chemical paralysis. In contrast, S. pengi displayed a distinct "protein-dominant" signature enriched with high-molecular-weight enzymes and CAP superfamily proteins, likely functioning to facilitate tissue degradation and toxin diffusion. Occupying an intermediate position, H. lycosina demonstrated a hybrid composition. These findings suggest that although these species share the same geographical range, their venom systems have undergone divergent evolutionary adaptations driven by specific ecological niches and hunting strategies. This study represents the first systematic proteomic characterization of these venom components, providing a valuable reservoir of molecular candidates while highlighting the bioinformatic nuances of analyzing whole-gland homogenates.

Animals

Artificial Intelligence for Diagnosing Meibomian Gland Dysfunction: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies.

PURPOSE: To identify, appraise, and synthesize the performance of artificial intelligence-based meibography reading as compared with human graders in diagnosing meibomian gland dysfunction. METHODS: We followed Cochrane methodology and reporting guidelines for diagnostic test accuracy reviews. To assess potential risk of bias and applicability, we used a modified Quality Assessment of Diagnostic Accuracy Studies-2 checklist. We applied bivariate logistic models to estimate summary sensitivity and specificity when appropriate and used the GRADE framework to rate the certainty of the evidence. RESULTS: We identified 14 eligible studies involving 5511 predominantly middle-aged participants (average age: 27-55 years) who were primarily female (≥54.5%). A total of 18,926 meibography images were obtained through noncontact infrared (11 studies) or in vivo confocal microscopy (three studies). Two studies reported external validation of deep learning models, 12 reported internally validated models, and one reported both. All but one study had high risk of bias in at least one domain; 12 studies raised high or intermediate concern about applicability. Based on three external evaluations, the summary sensitivity and specificity for diagnosing meibomian gland dysfunction from normal glands were 97.5% (95% confidence interval: 77.5%-99.8%) and 85.5% (95% confidence interval: 47.3%-97.5%). Sources of heterogeneity in internally validated models included study population, case mix, and others. The overall evidence was very low to low certainty because of imprecision, high risk of bias, and concerns about applicability. CONCLUSIONS: Artificial intelligence-based meibography grading appears less accurate than human graders. Future studies should adopt rigorous designs, including a more diverse participant pool (or image set), and external validation.

Humans

Performance of Automated Hematology Analyzer Criteria in Detecting Peripheral Blood Smear Abnormalities: A Systematic Literature Review.

OBJECTIVES: Criteria for visual examination of stained peripheral blood smear (PBS) differ among institutions in the United States and internationally. In an effort to standardize review criteria, the International Consensus Group for Hematology Review (ICGHR) proposed in 2005 a consensus list of rules for CBC findings that should trigger a review of automated cell counter results and potentially lead to further testing or blood smear review. The primary aim of this paper is to report on the published literature in the past 20 years regarding PBS review criteria and their ability to identify relevant peripheral blood abnormalities. METHODS: We performed a systematic review of the published literature from 2005 to 2025 to investigate and summarize PBS review criteria and performance in the context of automated hematology analyzers in clinical laboratories. RESULTS: Of 5351 citations, 68 studies met our search criteria. These studies included 22 countries and all major hematology analyzer manufacturers. Marked variability was observed in study populations, analyzer flagging criteria, details of PBS visual review, definitions of a "positive" smear, and approaches to statistical data analysis. Across studies, the blast flag sensitivity ranged from 18% to 100% while the blast flag specificity ranged from 17% to 100%. Wide ranges in sensitivity/specificity were also seen for atypical and/or abnormal lymphocyte flags across studies. For studies analyzing the same patient population, less striking variation was seen across instruments. CONCLUSIONS: This systematic review provides a 20-year overview of the literature, highlighting significant variability in PBS review criteria, dependence on study design and hematology analyzer, and the importance of developing harmonized evidence-based guidelines.

Humans

Artificial intelligence for dental caries detection: An umbrella review.

Artificial intelligence (AI) has been proposed as a tool to improve dental caries detection across imaging modalities; however, its clinical value remains uncertain. This umbrella review aimed to synthesize and critically appraise systematic reviews evaluating AI for caries detection and diagnosis. An umbrella review was conducted following PRIOR guidance (PROSPERO CRD420261340728). Searches were performed in MEDLINE, Embase, Scopus, Web of Science, and Google Scholar up to 15 March 2026. Methodological quality was assessed using AMSTAR 2, and overlap of primary studies was quantified using the corrected covered area (CCA). Seventeen systematic reviews were included, of which five reported diagnostic test accuracy meta-analyses using bivariate or HSROC models. Across these meta-analyses, pooled sensitivity ranged from 0.76 to 0.94 and specificity from 0.85 to 0.91. Most systems were based on deep learning models applied to bitewing radiographs and intraoral photographs. However, substantial heterogeneity was observed in imaging modalities, lesion thresholds, analytical tasks, and evaluation metrics. In addition, a high degree of overlap across reviews and recurrent methodological limitations, including reliance on retrospective datasets, limited external validation, and inconsistent reporting, substantially weaken the reliability of the evidence. Although AI models demonstrate high diagnostic performance under experimental conditions, current evidence does not support their use as stand-alone diagnostic tools. Their clinical applicability remains limited, and implementation should be restricted to decision-support contexts until robust prospective validation demonstrates meaningful impact on clinical decision-making and patient outcomes.

Dental Caries

Enhancing Hemoglobin Bart's hydrops fetalis syndrome prevention: a single-tube multiplex real-time PCR assay for the comprehensive detection of four significant α0-thalassemia deletions (--SEA, --THAI, --CR, and --SA) found in Thailand.

BACKGROUND: Hemoglobin (Hb) Bart's hydrops fetalis is a major public health concern in Southeast Asia, particularly in Thailand. Current screening strategies target the two most common α0 -thalassemia deletions (--SEA and --THAI). METHOD: In this study, we developed a single-tube multiplex real-time PCR assay for the simultaneous detection of four clinically relevant α0-thalassemia deletions (--SEA, --THAI, --CR, and --SA). The assay was validated using 538 clinical samples with diverse thalassemia genotypes and compared against conventional gap-PCR as the reference method. Analytical performance, including sensitivity, specificity, and limit of detection (LOD), was evaluated. In addition, clinical utility was assessed in 22 prenatal diagnosis cases at risk of Hb Bart's hydrops fetalis. RESULTS: The study cohort demonstrated substantial genetic heterogeneity, comprising 43 distinct genotypes. The developed assay achieved 100% sensitivity and specificity for all targeted deletions, with complete concordance with gap-PCR results. No cross-reactivity was observed with α+-thalassemia. The assay demonstrated a high analytical sensitivity with a LOD of 9.76 × 10-3 ng per reaction. Whereas in prenatal diagnosis, all 22 fetal genotypes were accurately identified, including five cases of homozygous --SEA and one rare compound heterozygous --SEA/--CR fetus. CONCLUSIONS: This study presents a rapid, accurate, and cost-effective multiplex real-time PCR assay capable of detecting both common and rare α0-thalassemia deletions in a single reaction. The assay demonstrates strong potential for implementation in routine clinical laboratories and large-scale population screening, contributing to improved prevention and control of severe thalassemia syndromes in high-prevalence regions.

Humans