Search PubMedSearch

SEARCH · Search PubMed

Results for “Hospital Design and Construction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,986 records · Page 16Linked to original sources

Measuring Coping Strategies in Daily Life: A Systematic Review of Experience Sampling Methodology and Daily Diary Studies.

Advances in daily diary methods and experience sampling method (ESM) have improved the study of coping strategies in daily life and their role in shaping health and well-being. In this review, we examine study designs, measurement approaches, and analytical practices used to investigate coping in natural contexts. We performed a systematic review of studies published before 5 December 2025 that used daily diary or ESM to measure coping strategies over multiple days or moments. Studies were examined with regard to sampling schemes, assessment frequency and duration, measurement of coping strategies, incorporation of stressor appraisals, and analytic techniques used to model coping processes. Fifty-five studies met the inclusion criteria. Results indicated that 80% employed end-of-day diary designs, generally lasting 1-3 weeks, whereas higher-frequency ESM protocols were less common and ranged 2-14 days. Coping strategies were often assessed using abbreviated or single-item measures, frequently adapted from established questionnaires. Many studies incorporated appraisals such as perceived stressor intensity or controllability, enabling tests of coping flexibility. Multilevel modelling was the dominant analytic approach, allowing researchers to distinguish within-person dynamics from between-person differences. However, analyses were predominantly concurrent, and temporally ordered models remained comparatively rare. Overall, the literature demonstrates substantial progress in capturing coping in everyday contexts, yet heterogeneity in measurement and limited use of temporal modelling constrain cumulative knowledge about the temporal links between coping and psychological and physiological health outcomes. Future research would benefit from greater alignment between theoretical assumptions, assessment strategies, and analytic methods.

Humans

Navigating Social Media: Balancing Connectivity With Media Literacy to Combat Misinformation and Protect Mental Well-Being.

BACKGROUND: The pervasive use of social media has created a complex digital ecosystem where high connectivity coexists with significant challenges, including the rapid spread of misinformation, particularly regarding mental health, and documented negative impacts on psychological well-being. Platform architectures designed for engagement maximization have been identified as central factors in both issues. OBJECTIVE: This paper critically analyzes the interconnected relationships between social media use, misinformation dissemination, and mental health impacts, with particular attention to psychiatric misinformation across diagnostic categories (e.g., depression, anxiety, ADHD). A primary objective is to evaluate the potential of advanced critical digital literacy frameworks to serve as protective mechanisms against these dual threats. METHODS: A systematic search was conducted following PRISMA 2020 guidelines across APA PsycInfo, PubMed, JSTOR, and Google Scholar for literature published between January 2018 and March 2026 (updated from the original 2023 search). The search yielded 2672 records. After removing 624 duplicates, 2048 records underwent title and abstract screening, with 1802 excluded. The remaining 246 full-text articles were assessed for eligibility, resulting in 86 studies included in the final qualitative synthesis. Inter-rater reliability was established (Cohen's κ = 0.82). Quality assessment was conducted using the Joanna Briggs Institute Checklist, AXIS, and CASP tools, with findings weighted by methodological quality. A thematic analysis was undertaken to synthesize findings. RESULTS: The analysis reveals that core architectural features of social media platforms, algorithmic curation and engagement-based metrics, simultaneously foster environments ripe for misinformation spread and contribute to psychological distress, including anxiety, depression, and harmful social comparison. Psychiatric misinformation specifically (e.g., inaccurate claims about treatment effectiveness, diagnostic criteria, and medication side effects) represents a growing concern, particularly on image- and video-based platforms. The findings indicate that conventional media literacy approaches focused solely on fact-checking are insufficient. Instead, a critical digital literacy framework encompassing algorithmic awareness, data literacy, and emotional awareness is essential for building user resilience, with evidence from high-quality systematic reviews supporting this approach. CONCLUSIONS: Navigating the complexities of modern social media requires an integrated approach combining "pedagogies of play" for experiential skill development with advocacy for structural change (e.g., algorithmic transparency, well being by design principles). This dual strategy empowers individual users to critically engage with digital content while advocating for ethical platform design, thereby safeguarding both mental well-being and democratic discourse. Implications for educators, mental health professionals (including competencies for addressing patient encounters with psychiatric misinformation), policymakers, and platform designers are discussed.

Humans

Effectiveness of Mobile-Delivered Exercise and Yoga Programs on Depressive Symptom Reduction in Employees: Randomized Controlled Trial.

BACKGROUND: Mental health challenges such as stress and depression are prevalent among employees. Mobile health platforms that deliver exercise or yoga interventions offer a promising approach to improve mental health outcomes in this population. OBJECTIVE: This study aimed to assess the effectiveness of 12-session adaptive moderate-intensity exercise and yoga programs delivered via a motion-detecting digital platform in reducing stress and depressive symptoms among employees. METHODS: This was an unblinded, 3-arm, parallel-group, randomized controlled trial conducted at Seoul National University Bundang Hospital and Boramae Medical Center between November 2023 and January 2024. Eligible participants were full-time employees. Seventy-five participants were randomly assigned to an exercise, a yoga, or a cognitive behavioral therapy-based self-care control group using computer-generated randomization. The exercise and yoga groups engaged in motion-detecting, adaptive physical activity training, whereas the control group accessed mobile-based, self-directed stress management educational materials. The intervention was largely automated, with no individualized therapeutic guidance provided. Allocation was concealed until trial entry. All recruitment and outcome assessments were conducted in person at the hospitals. The primary outcomes were perceived stress and depressive symptoms, whereas the secondary outcomes included posttraumatic stress, insomnia severity, cognitive stress response, occupational stress, and burnout. Physiological outcomes were assessed using heart rate variability and electroencephalography. Measurements were collected at baseline, immediately after the intervention, and at 4-week follow-up. Data were analyzed using a multivariate linear model to evaluate the main effects of time, group, and time&#xd7;group interactions. RESULTS: Of the 75 randomized participants (exercise: n=24, 32%; yoga: n=25, 33.3%; and control: n=26, 34.7%), 71 (94.7%) who completed at least 9 of the 12 sessions (&#x2265;40 min each) were included in the outcome analysis (exercise: n=21, 29.5%; yoga: n=24, 33.8%; and control: n=26, 36.6%). For the coprimary outcomes, the group&#xd7;time interaction for depressive symptoms (Patient Health Questionnaire-9) approached but did not reach the Bonferroni-corrected threshold (F4,136=2.71; P=.03; adjusted &#x3b1;=.025); however, planned pairwise comparisons revealed significantly greater improvement in the yoga group compared to the control group at 4-week follow-up (&#x3b2;=-3.67; adjusted P<.001). For the Perceived Stress Scale, the interaction was not significant (P=.29), although a significant main effect of time (P<.001) indicated overall stress reduction across all groups. For secondary outcomes, a significant group&#xd7;time interaction was found for the Cognitive Stress Responses Scale (P=.003), indicating differential trajectories of improvement. The yoga group showed a consistent linear decrease, whereas the exercise group showed immediate but less sustained gains. CONCLUSIONS: Digitally delivered adaptive yoga programs demonstrated superior and sustained improvements in depressive symptoms and Cognitive Stress Responses Scale scores compared with the active cognitive behavioral therapy-based self-care control group. However, the exercise program showed more modest and less sustained effects, warranting further investigation using larger samples.

Adult

Design, rationale, and baseline patient characteristics for the Sickle Cell Disease and CardiovAscular Risk-Red cell Exchange (SCD-CARRE) trial.

BACKGROUND: Despite wide utilization of automated red blood cell exchange (RBCX) transfusion in adult patients with sickle cell disease (SCD), no consensus or quality efficacy data exist on its use. The Sickle Cell Disease and CardiovAscular Risk- Red cell Exchange (SCD-CARRE) trial tests the hypothesis that an automated chronic RBCX transfusion strategy reduces acute health care encounters and death while improving quality of life and end-organ function (cardiac, pulmonary and renal) in participants with SCD that are at high risk of death. METHODS: Adult patients with SCD with elevated tricuspid regurgitant jet velocity (TRV) and/or chronic kidney disease were considered to be at high risk of death and were randomly assigned to RBCX plus standard of care vs standard of care alone. Participants assigned to RBCX received 12 months of exchange transfusions to maintain target pretransfusion hemoglobin S% < 30%, post-transfusion hemoglobin S% < 20%, and post-transfusion hemoglobin concentration &#x2265;10 g/dL. All study participants were managed according to NHLBI/ASH/ATS Expert Panel guidelines. The primary endpoint was the number of SCD acute health care encounters or death over 13 months. Secondary endpoints included measures of cardiovascular and renal function, exercise capacity, patient reported outcomes (all collected at baseline, and months 4, 8, and 12), and transfusion-related adverse events (collected monthly). RESULTS: Between 2020 and 2025, the SCD-CARRE trial randomized 173 participants at 23 sites across 3 countries. Enrolled participants had mean (SD) age of 45.8 (11.8) years and 54% were female. At baseline, participants had average TRV of 2.8 (0.5) m/s such that 45.9% had a TRV between 2.5 to 2.9 m/sec and 28.1% had a TRV &#x2265; 3.0 m/sec. The median (Q1, Q3) eGFR in this cohort was 60 (36, 110) mL/min/1.73 m2. The median (Q1, Q3) 6-minute walk test distance was 375 meters (309, 439), the median daily steps were 3,728 (2,187, 5,821), and participants experienced a median (Q1, Q3) of 2 (1, 5) pain episodes in the year prior to randomization. The trial results are pending. CONCLUSIONS: The SCD-CARRE trial successfully enrolled a cohort of n = 173 adults with SCD. This study highlights a rationale to evaluate the effect of automated chronic RBCX transfusion strategy plus standard of care as compared to standard of care alone in SCD patients at high risk of death with a focus on patient centered outcomes, preservation of cardiovascular function, end-organ complications and death. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT04084080, https://clinicaltrials.gov/study/NCT04084080.

Adult

Endoscopic Ultrasound-Guided Franseen Fine-Needle Biopsy for Solid Pancreatic Lesions: A Systematic Review and Meta-Analysis.

INTRODUCTION: Accurate tissue acquisition (TA) of solid pancreatic lesions is essential for guiding treatment with endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) being the preferred method. Among FNB designs, the three-pronged Franseen-tip needle demonstrates strong diagnostic performance, though direct head-to-head comparisons with other FNB designs remain limited. METHODOLOGY: This meta-analysis was conducted in accordance with PRISMA guidelines (PROSPERO: CRD420251123856). Eligible studies enrolled patients with solid pancreatic lesions who underwent EUS-guided FNB, directly compared the Franseen-tip with other FNB needles. Six databases were systematically searched through July 2025, and study selection, data extraction, and risk of bias assessment (QUADAS-2 tool) were performed independently by two reviewers. Pooled estimates were generated using random-effects and bivariate hierarchical models. RESULTS: Sixteen studies (2,010 Franseen vs. 2,811 comparator) were included. Bivariate analysis showed that sensitivity and specificity of the Franseen needle were comparable to newer-generation comparator needles (sensitivity 91.3% vs. 94.0%; specificity 99.99% vs. 99.15%), whereas older-generation needles demonstrated lower sensitivity (80.8%) and inferior discriminatory performance (Negative Likelihood Ratio [LR&#x207b;] 0.19 vs. 0.09). Diagnostic accuracy was higher with the Franseen needle (RR 1.07, 95% CI 1.01-1.14; I2&#x2009;=&#x2009;69%). Sample adequacy was similar overall (RR 1.04, 95% CI 0.95-1.14) but superior to older-generation needles (RR 1.19, 95% CI 1.02-1.41) and in lesions&#x2009;>&#x2009;30&#xa0;mm (RR 1.14, 95% CI 1.02-1.28, I2&#x2009;=&#x2009;81.2%). The Franseen needle achieved nominally strong diagnostic performance (DOR 116.6), although small-study effects were observed. Primary procedural outcomes were comparable between Franseen and comparator needles, including technical success (RR 1.00, 95% CI 0.98-1.02) and histological core procurement (RR 1.04, 95% CI 0.92-1.17). The Franseen needle had fewer low-cellularity samples (RR 0.56, 95% CI 0.45-0.69) and lower specimen bloodiness (RR 0.48, 95% CI 0.25-0.90) but a slightly higher overall adverse event rate (RR 1.29, 95% CI 1.06-1.57). CONCLUSION: The Franseen needle provides superior diagnostic accuracy and sample adequacy compared to older-generation FNB needles with comparable performance to newer-generation designs. It reduces low-cellularity samples and specimen bloodiness, although adverse events are slightly increased, with other primary procedural outcomes remaining comparable. TRIAL REGISTRATION: PROSPERO (Registration No. CRD420251123856).

Humans

Redefining the real problem in psychedelic trials: Why fighting the Lessebo matters more than blinding integrity.

Imperfect blinding is not specific to psychedelic trials. In randomized trials, treatment allocation is frequently correctly guessed, yet blinding integrity is rarely assessed outside of psychedelic research and is generally not considered a barrier in regulatory evaluation. The intense debate in psychedelics may reflect a broader double standard affecting mental health research, when uncertainties arising from imperfect blinding are confounded by those linked to patient-reported outcome measures. Indeed, people living with mental disorders are often viewed as unreliable reporters, despite well-documented limitations of clinician-rated scales and the absence of robust biological markers of symptomatic change. Importantly, it is the maintenance of reasonable doubt of treatment allocation that sustains internal validity and ethical feasibility of placebo-controlled designs, rather than perfect blinding. Concerns about expectancy bias in psychedelic trials are closely tied to blinding debates. When allocation is inferred, expectations may cluster in the arm perceived as active or in stereotyped experiences and influence outcomes differently in active and control arms, leading to a risk of lessebo, a negative placebo effect due to the negative expectation related to receiving a placebo. However, we argue that an underrecognized mechanism of lessebo is disappointment. This risk may reflect insufficient clinical management of disappointment rather than pre-treatment expectation alone. We therefore propose shifting the emphasis from preserving inevitably imperfect blinding towards mitigating disappointment in both arms. Establishing non-stereotyped expectations prior to treatment through structured psychoeducation, strengthened therapeutic alliance, and realistic preparation would help avoid lessebo effects. Such strategies would enhance ethical rigor, interpretability, and the clinical usefulness of psychedelic trials.

Humans

Human-Centered Workspace Optimization: A 2 &#xd7; 2 Factorial Study of Adjustable Furniture and Indoor Environmental Quality.

Small workspaces function as integrated systems, yet ergonomic furniture and indoor environmental conditions are usually evaluated separately. A six-site, assessor-blinded, randomized 2 &#xd7; 2 factorial controlled study was conducted of two multicomponent packages-adjustable furniture and optimized indoor environmental quality (IEQ)-among 240 office workers for four weeks. Each group included 60 participants. Overall comfort in week 4 was highest for both packages (5.62 &#xb1; 0.53 versus 3.99 &#xb1; 0.60 with fixed furniture and basic IEQ). In a site-adjusted factorial model with HC3 robust standard errors, the adjustable-furniture effect was 0.86 points (95% confidence interval [CI], 0.62-1.09), the optimized-IEQ effect was 0.34 points (95% CI, 0.12-0.55), and their interaction was 0.44 points (95% CI, 0.14-0.74). Adjustable furniture improved postural comfort and reduced neck and lower back discomfort; optimized IEQ improved environmental comfort; both packages improved perceived productivity, satisfaction, and fatigue. The task-accuracy interaction did not remain significant after false-discovery-rate adjustment, and exploratory mediation and spline analyses did not support indirect or nonlinear effects. These results support coordinated ergonomic and environmental implementation while preserving distinct outcome pathways.

Interior Design and Furnishings

Prevalence and Factors Associated with Receiving a Prescription for a Direct Oral Anticoagulant Among Patients with Atrial Fibrillation on Hospice Admission.

Atrial fibrillation (AF) is prevalent in hospice care, but anticoagulation decisions in this population are not well understood. In this cross-sectional study, we described the prevalence and characteristics associated with direct oral anticoagulant (DOAC) prescription on hospice admission. We used electronic health data from adult decedents with AF in a large, for-profit hospice chain in the United States between January 1, 2017 and December 31, 2019. We used multivariable logistic regression with results reported as adjusted odds ratios (AORs) and 95% confidence intervals (CIs). Among 13,233 decedents, mean (standard deviation [SD]) age was 84.2 (9.9) years, 53.6% were female, 65.1% were White, and 56.1% were referred to hospice from a hospital. Mean (SD) CHA2DS2-VASc score were 3.8 (1.4) for males and 4.8 (1.3) for females, and mean (SD) HAS-BLED score was 2.2 (1.0). Overall, 8% of patients received a DOAC prescription on hospice admission. Characteristics associated with receiving a DOAC prescription included PPS scores of &#x2265; 20% (compared to scores < 20%), and receiving hospice care at home, nursing home, assisted living facility, or residential care home (compared to inpatient hospice). Further studies about the risks and benefits of DOAC use are needed to optimize decision-making in this population.

DOAC

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans

Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis.

BACKGROUND: Obstructive sleep apnea (OSA) is highly prevalent but remains substantially underdiagnosed. Polysomnography (PSG) is the reference standard, but its cost and limited availability constrain large-scale case identification. AI-based screening tools may support risk stratification and referral prioritization, but their diagnostic accuracy across apnea-hypopnea index (AHI) thresholds remains uncertain. OBJECTIVE: This review aimed to systematically evaluate the diagnostic accuracy of AI-based OSA screening tools at AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, with emphasis on models using non-PSG-derived inputs. METHODS: PubMed, Embase, Scopus, and Web of Science were searched for studies published from January 1, 2016, to May 3, 2026. Eligible studies included adults evaluated for suspected OSA or recruited from population-based cohorts, assessed AI-based models intended or interpretable for OSA screening, risk prediction, or screening-oriented severity classification, used PSG as the reference standard, and reported sufficient data to construct or reconstruct 2&#xd7;2 contingency tables. Diagnostic accuracy was synthesized separately by AHI threshold and input source using bivariate random-effects models, with 95% CIs and prediction intervals (PIs). Risk of bias and certainty of evidence were assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) and GRADE (Grading of Recommendations Assessment, Development, and Evaluation), respectively. RESULTS: A total of 60 studies were included, of which 47 contributed data to the meta-analysis. At AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, pooled sensitivities were 0.94 (95% CI 0.92-0.96; 95% PI 0.71-0.99), 0.87 (95% CI 0.84-0.89; 95% PI 0.66-0.96), and 0.83 (95% CI 0.79-0.87; 95% PI 0.61-0.94), respectively; the corresponding specificities were 0.77 (95% CI 0.69-0.84; 95% PI 0.30-0.96), 0.81 (95% CI 0.75-0.85; 95% PI 0.39-0.96), and 0.91 (95% CI 0.87-0.94; 95% PI 0.55-0.99), respectively. The corresponding areas under the summary receiver operating characteristic curves were 0.943, 0.907, and 0.920. For non-PSG-derived tools, sensitivities were 0.92, 0.85, and 0.81, and specificities were 0.70, 0.74, and 0.85 at the 3 thresholds, respectively. For PSG-derived models, sensitivities were 0.96, 0.90, and 0.85, and specificities were 0.82, 0.88, and 0.96, respectively. Exploratory subgroup analyses suggested performance variation across selected study and model characteristics, including region, algorithmic framework, data source, and validation method. CONCLUSIONS: AI-based tools showed generally favorable screening performance for OSA across clinically relevant AHI thresholds, although wide PIs suggest variable performance across future comparable populations and settings. By synthesizing diagnostic accuracy across 3 AHI thresholds and distinguishing non-PSG-derived from PSG-derived models, this review extends previous broad or modality-specific reviews and offers a clinically interpretable, pathway-specific basis for linking model performance to intended use. The findings may clarify potential roles for non-PSG-derived tools in front-end screening and referral prioritization and for PSG-derived models in reduced-channel assessment and sleep-laboratory workflow support. Given substantial heterogeneity, limited external validation, and low or very low certainty of evidence, prospective validation is needed before routine implementation.

Humans

Re-evaluating pediatric laryngoscope blade size recommendations: Comparable intubation performance across blade sizes in pediatric manikin models.

BACKGROUND: Pediatric airway management traditionally emphasizes strict adherence to age-based laryngoscope blade size recommendations, despite limited empirical validation. OBJECTIVES: To evaluate whether intubation performance varies across a range of blade sizes, and whether a Macintosh 2 blade performs comparably across multiple pediatric age groups in a simulation setting. METHODS: We conducted a randomized crossover simulation study using three pediatric airway manikins (neonate, infant, and child age groups). Emergency medicine residents and faculty physicians performed intubations using multiple laryngoscope blade types and sizes, including standard and nonstandard options. Primary outcomes were intubation time and first-attempt success. Secondary outcomes included complications and operator-rated ease of glottic view and tube passage. Between-blade differences were estimated with 95% confidence intervals. RESULTS: Across manikin sizes and blade types, intubation times were short and first-attempt success rates exceeded 98% in most conditions. Performance remained consistent even with blade sizes outside conventional age-based recommendations. Between-blade differences in intubation time were small, and complication rates were low across conditions. The Macintosh 2 blade performed comparably across all manikin sizes, with similar intubation times, high success rates, and favorable ease ratings. CONCLUSIONS: Intubation performance in pediatric manikin models was similar across a wide range of blade sizes. These hypothesis-generating findings warrant prospective clinical evaluation of simplified blade selection strategies for pediatric intubation.

Manikins

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Beyond da Vinci: a systematic review of next-generation multiport robotic platforms in pediatric surgery.

As robotic surgery expands beyond the da Vinci platform, the relevance of new-generation systems to pediatric patients remains uncertain. This review examined the technical characteristics, applications, and perioperative outcomes of alternative multiport robotic platforms in children. PubMed/MEDLINE, Web of Science, Scopus, and the Cochrane Library were searched through 28 February 2026 in accordance with PRISMA 2020. Owing to clinical heterogeneity, findings were synthesized narratively, with Wilson 95% confidence intervals for key binary outcomes. Six studies reported 166 patients across 27 procedure types. Senhance accounted for 164 patients, while Hugo RAS and Hinotori were each represented by one patient. Ages ranged from 15&#xa0;days to 17&#xa0;years and weights from 3.8 to more than 100&#xa0;kg. Senhance was the only platform used with 3-mm robotic instruments. Conversion or planned escalation occurred in 19 patients (11.4%; 95% CI, 7.5-17.2%). Four intraoperative complications were reported (2.4%; 95% CI, 0.9-6.0%). Across all reports, 20 patients experienced postoperative complications (12.0%; 95% CI, 7.9-17.9%). In the largest cohort, seven patients required reintervention (4.6%; 95% CI, 2.2-9.2%) and seven were readmitted (4.6%; 95% CI, 2.2-9.2%). No deaths or comparative pediatric studies were reported. Published experience remains sparse and is almost entirely limited to Senhance. Current evidence describes early clinical use without establishing comparative safety, effectiveness, or platform superiority. Prospective multicenter studies with standardized reporting are needed.

Humans

Evaluating Patient Satisfaction and Oral Health Impact Profile-14 (OHIP-14): A Multicenter Crossover Study Comparing Selective Pressure Impression Conventional Dentures with Mucostatic Digital Dentures.

PURPOSE: To compare patient satisfaction and oral health impact between individuals receiving complete dentures made by digital methods and those using conventional techniques. MATERIALS AND METHODS: In this randomized crossover clinical trial, 23 patients aged 40 years and older with completely edentulous arches were enrolled at three treatment centers. Each participant received two sets of complete dentures: one set created using conventional methods (selective pressure impression) and the other through digital techniques (mucostatic digital impression). The order of denture placement was randomized, with each set used for 4 weeks. A trained specialist administered treatments alongside research tools, including a general information questionnaire, a denture satisfaction survey, and the OHIP-14 interview tool. Statistical analysis was conducted using Mann-Whitney U test. RESULTS: Participants with digital dentures reported significantly higher satisfaction regarding treatment duration, comfort, confidence, chewing ability, esthetics, and overall satisfaction compared to those with conventional dentures. There were no significant differences in satisfaction concerning speech and pronunciation. Overall, the oral health impact on quality of life was similar between denture types, but participants indicated improved quality of life while using dentures compared to being edentulous. CONCLUSIONS: Patients with digital dentures exhibited greater satisfaction across various domains compared to those with conventional dentures, despite similar satisfaction levels in speech and pronunciation. The impact on quality of life was comparable between both types, as measured by the OHIP-14.

Humans

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Clinical predictors of severe and fatal respiratory syncytial virus infection in adults and the elderly: A retrospective cohort study.

BACKGROUND: Respiratory syncytial virus (RSV) is increasingly recognized as a cause of severe respiratory illness in adults, especially the elderly and those with comorbidities. However, data on outcomes and risk factors for severe disease in this population remain limited. METHODS: We retrospectively analyzed 123 adult patients diagnosed with RSV infection at a tertiary center in Taiwan from 2015 to 2023. Clinical characteristics, laboratory data, detection of other pathogens, clinical course and outcome were reviewed. Multivariable logistic regression identified risk factors for severe RSV infection, including ICU admission and 30-day mortality. RESULTS: The mean age was 55.7 years; 50% were aged &#x2265;60 years and 13% were &#x2265;75 years. ICU admission occurred in 17%, with significant associations to viral coinfection and elevated C-reactive protein (CRP). Thirty-day mortality was 13%, and overall in-hospital mortality was 18%, all among patients with comorbidities. Independent predictors of 30-day mortality included late elderly (aOR 24.2, p&#x202f;=&#x202f;0.03), high CRP > 11.5&#x202f;mg/dL (aOR 16.4, p&#x202f;=&#x202f;0.005) and thrombocytopenia < 34,103/&#x3bc;L (aOR 11.4, p&#x202f;=&#x202f;0.01). CONCLUSION: Advanced age (&#x2265;75 years), high CRP, and severe thrombocytopenia are key predictors of mortality in adults RSV patients. These findings highlight the need for targeted prevention strategies, including vaccination, in high-risk populations.

Co-infection

Patient-reported outcome measures for depression or anxiety symptoms in patients with cardiovascular disease: A COSMIN systematic review.

BACKGROUND: Depression and anxiety are common in patients with cardiovascular disease (CVD), but the measurement quality of patient-reported outcome measures (PROMs) used in this population remains unclear. This review aimed to evaluate the methodological quality, measurement properties, and certainty of evidence for depression and anxiety PROMs in adults with CVD and to inform instrument selection. METHODS: Following COSMIN and PRISMA guidance, four databases were searched from inception to February 2026. Studies assessing measurement properties of PROMs in adults with CVD were included. Methodological quality was evaluated using the COSMIN Risk of Bias checklist, and certainty of evidence was graded using an adapted GRADE approach. RESULTS: Sixty-six studies assessing 38 PROMs were included, comprising 29 generic and 9 CVD-specific instruments. Six PROMs met COSMIN Category A criteria: Cardiac Depression Scale-Short Form, Patient Health Questionnaire-9, Beck Depression Inventory-II, Hospital Anxiety and Depression Scale, Generalized Anxiety Disorder-7, and Major Depression Inventory. Four instruments were classified as Category C because of insufficient structural validity. Content-validity evidence was largely indeterminate or of limited certainty. Only 24 studies used confirmatory factor analysis or Rasch analysis, and no study assessed measurement error or responsiveness. Cross-cultural validity evidence was scarce. CONCLUSIONS: Six PROMs met Category A criteria, but selection should remain purpose- and context-specific. Particular attention should be given to somatic symptom overlap and intended clinical use. Further validation should prioritize content validity, measurement invariance, responsiveness, measurement error, and clinimetric performance.

Humans

Hybrid robotic transversus abdominis release (hrTAR) for complex ventral hernias: a systematic review and preliminary synthesis.

Hybrid robotic transversus abdominis release (hrTAR) combines robotic posterior component separation with a planned limited open phase. Evidence supporting this strategy is sparse. Following PRISMA 2020, we searched PubMed, Embase, Scopus, and the Cochrane Library and registered the protocol in PROSPERO (CRD420261303285). Eligible studies reported hrTAR outcomes for ventral or incisional hernia repair. Findings were synthesized narratively; no pooled effect estimates were calculated. Three reports contained 85 hrTAR cohort entries. Because two reports came from the same institution and overlap could not be excluded, this total should not be interpreted as a unique-patient count. Surgical-site outcomes were heterogeneous: two reports used SSO endpoints (4% and 5%), whereas another reported surgical-site events in 25% of patients, including seroma and wound infection. Mean length of stay ranged from 1.8 to 3.7 days; the sample-size-weighted mean across studies reporting means was 2.9 days. One propensity-matched comparison reported shorter hospitalization and lower 30-day SSO with hrTAR than open TAR. No perioperative deaths or recurrences were reported during limited follow-up. hrTAR appears feasible in selected patients, but available evidence is exploratory. Standardized prospective multicenter studies with non-overlapping cohorts and longer follow-up are needed before comparative effectiveness, economic value, or wider adoption can be supported.

Humans