Search PubMedSearch

SEARCH · Search PubMed

Results for “medical devices in Europe”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,959 records · Page 12Linked to original sources

Artificial intelligence enabled social robotic interventions (PARO) in Australian dementia care: A systematic review and meta-analysis.

BACKGROUND: Although there is a growing body of research indicating that Personal Robot/Social Robot could be used in various aspects of care for individuals with dementia, little is known about how well these types of interventions work in an actual hospital setting in Australia. AIMS & OBJECTIVES: The objective of the present systematic review and meta-analysis is to assess the effectiveness of PARO-based socially assistive robotic intervention in terms of its effectiveness outcomes towards the reduction of dementia-related behavioural and psychological symptoms in Australian based healthcare settings. METHODS: A systematic search was conducted across five electronic databases, including MEDLINE (PubMed), EMBASE, CINAHL, PsycINFO, and the Cochrane Library, to identify randomised controlled trials (RCTs) investigating PARO-based socially assistive robotic interventions for dementia in Australian healthcare settings. This review was registered with PROSPERO (CRD420251251916) and followed the PRISMA 2020 guidelines. In addition, the Cochrane Risk of Bias tool (RoB 2) was used to evaluate the risk of bias across all studies. Pooled standardised mean differences (SMD) with 95 % confidence intervals (CI) were calculated for agitation, anxiety, and depression. Heterogeneity across studies was evaluated using the I2 statistic. RESULTS: Six RCTs involving 1444 participants were identified for inclusion in this review. AI-enabled socially assistive robotic interventions, specifically the PARO therapeutic robot, significantly reduced agitation and anxiety when compared to standard treatment or control conditions. The pooled analysis showed that agitation [SMD = -0.44 (95 % CI: -0.70, -0.18) p = 0.0008] and anxiety [SMD = -0.59 (95 % CI: -0.91, -0.27) p = 0.0003] were reduced significantly, while the decrease in depression [SMD = -0.44 (95 % CI: -0.95, -0.07) p = 0.09] scores was non-significant among dementia patients receiving PARO-based socially assistive robotic interventions as compared to the control. The overall risk of bias across all six studies was considered low to moderate. CONCLUSION: PARO-based socially assistive robotic interventions may provide preliminary evidence of effectiveness in reducing agitation and anxiety in individuals with dementia in Australian healthcare, but the evidence regarding the reduction of depression remains unclear. Therefore, additional high-quality trials with consistent methodology and extended follow-up will be necessary to determine both the short-term and long-term clinical efficacy and practicality of implementing these interventions into practice.

Humans

High-Dose Intravenous Vitamin C and Mortality and Organ Dysfunction in Severe Burn Injury: The VICTORY Randomized Clinical Trial.

IMPORTANCE: Severe burn injury triggers systemic inflammation that can lead to multiple organ dysfunctions and death. High-dose intravenous vitamin C has been proposed to mitigate these effects, but strong evidence in patients with burn injury is lacking. OBJECTIVE: To evaluate the efficacy of high-dose intravenous vitamin C in patients with severe burn injury. DESIGN, SETTING, AND PARTICIPANTS: Randomized, double-blind, placebo-controlled phase 3 trial conducted across 24 burn centers in North, Central, and South America; Europe; and Asia. Adults (≥18 years) with deep second- and/or third-degree burns covering 20% or more of total body surface area and requiring skin grafting were enrolled between August 18, 2020, and September 12, 2025. Final follow-up was completed in March 2026. The trial was stopped early after the first prespecified interim analysis for futility/harm. INTERVENTIONS: Patients were randomly assigned (1:1) to receive intravenous vitamin C (50 mg/kg every 6 hours for 96 hours) or matched placebo. MAIN OUTCOMES AND MEASURES: The primary outcome was a composite of 28-day mortality and persistent organ dysfunction (defined as dependence on mechanical ventilation, kidney replacement therapy, or vasopressor/inotrope support at day 28). The main secondary outcome was time to discharge alive from hospital within 90 days. RESULTS: Among 238 patients enrolled (mean age, 48.9 [SD, 19.1] years; 79% male; mean total body surface area, 37.0% [SD, 14.6%]), 120 were assigned to vitamin C and 118 to placebo. The primary composite outcome occurred in 49 patients (40.8%) in the vitamin C group and 35 patients (29.7%) in the placebo group (adjusted risk ratio [RR], 1.28 [95% CI, 0.99-1.65]; P = .06), crossing the prespecified futility/harm threshold and prompting early trial termination. Time to discharge alive from hospital within 90 days was not improved (adjusted subdistribution hazard ratio, 0.85 [95% CI, 0.62-1.16]; P = .31). Twenty-eight-day mortality was higher in the vitamin C group (15.0% vs 7.6%; adjusted RR, 1.96 [95% CI, 1.32-2.90]; P = .001), as was hospital mortality (23.3% vs 16.1%; adjusted RR, 1.44 [95% CI, 1.03-2.00]; P = .03). CONCLUSIONS AND RELEVANCE: Among patients with severe burn injury, high-dose intravenous vitamin C did not reduce 28-day mortality and persistent organ dysfunction and is possibly harmful. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04138394.

Humans

Post-intervention effectiveness of a computerized personalized cognitive stimulation program adapted according to cognitive reserve in older adults without cognitive impairment in Primary Care: A randomized clinical trial.

BACKGROUND: Cognitive reserve may influence responsiveness to cognitive interventions, yet it is rarely used to tailor computerized stimulation. OBJECTIVE: To evaluate the effectiveness of a computerized cognitive stimulation program personalized according to cognitive reserve on cognition, reserve-related activities, and digital competence in community-dwelling older adults without cognitive impairment in Primary Care. METHODS: In this randomized clinical trial, 102 adults aged ≥65 years with normal cognitive performance were recruited from three primary care centers in Zaragoza, Spain, and stratified by cognitive reserve level before random allocation to intervention or control. The intervention comprised digital literacy sessions followed by 8 weeks of home-based computerized cognitive stimulation tailored to participants' cognitive reserve profiles and life history. Controls received a single group-based health education session focused on maintaining everyday cognitive activity. Outcomes were assessed at baseline and post-intervention using global cognition (MEC-35), the Cognitive Reserve Questionnaire, the Mobile Device Proficiency Questionnaire-16, and domain-specific neuropsychological tests. A total of 100 participants completed the final evaluation and were included in complete-case analyses. RESULTS: Compared with controls, the intervention group showed greater adjusted post-intervention improvements in global cognition (MEC-35 between-group difference: 1.8 points) and several cognitive measures, including temporal orientation, calculation, attention, praxis, verbal fluency, processing speed, executive functions, and verbal learning. CRQ scores and digital competence also improved, with small-to-large effect sizes. CONCLUSIONS: A computerized cognitive stimulation program adapted according to cognitive reserve appears feasible in Primary Care and may improve cognition, engagement in reserve-related activities, and digital competence in older adults without cognitive impairment.

Humans

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2×2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I²=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans

Comparative Evaluation of Virtual Reality versus Standard Nursing Care in Managing Pain and Fear during Lumbar Puncture Procedures: A Randomised Controlled Trial.

BACKGROUND: Meningitis is a serious infectious disease that can cause significant morbidity and long-term neurological problems. Although a lumbar puncture is a necessary diagnostic procedure, it is often accompanied by discomfort, anxiety, and fear, which can severely impact the patient's experience. Although there is few data on its application prior to lumbar puncture in adult patients with meningitis, immersive virtual reality (VR) has become a promising non-pharmacological technique for lowering procedural distress. Thus, among individuals undergoing lumbar punctures, this randomized controlled research assessed how well pre-procedural VR reduced pain, anxiety, and fear while enhancing patient satisfaction. OBJECTIVE: This study aims to evaluate the effectiveness of virtual reality (VR) in reducing pain and fear among adults undergoing lumbar puncture (LP) compared with standard care protocol. METHODS: A randomised clinical trial was conducted from May to October 2025, using a single-blind, true experimental design. A total of 85 patients were randomly assigned to either the VR intervention group ( n = 41) or the control group receiving standard care ( n = 44). Pain levels were assessed using a visual analogue scale. Fear was assessed using the Multidimensional Fear-of-Injection Scale. Data were analysed using SPSS version 26. RESULTS: According to the study, the findings revealed a significant reduction in pain levels among the study group following the VR intervention, with mean pain scores dropping from 7.54 ± 1.925 to 2.49 ± 0.675. In contrast, the control group showed increased pain intensity, with mean scores rising from 6.84 ± 1.842 to 8.36 ± 1.348. The VR group showed a significant reduction in fear scores across all domains, whereas no significant changes were observed in the control group. Direct fear decreased from 20.12 ± 1.71 to 9.44 ± 2.00, indirect fear from 17.24 ± 1.46 to 8.66 ± 2.24, physiological response improved from 0.34 ± 0.66 to 3.00 ± 1.00 and avoidance behaviour decreased from 16.71 ± 1.49 to 7.80 ± 1.85. CONCLUSIONS: The research shows that the use of VR prior to LP significantly reduces level of pain and fear compared to standard care. These results support VR as a non-pharmacological intervention for fear and pain to improve patient experience during invasive procedures. In contrast, the control group experienced no improvement.Trial Registration: The IRCT code for the trial was IRCT ID 20250803066743N1.

Humans

Do adherence-focused interventions in low back pain have an impact on rehabilitation outcomes? A systematic review with meta-analysis.

BACKGROUND: Low back pain (LBP) is the leading cause of disability worldwide. Exercise-based interventions are effective, but adherence remains suboptimal. This systematic review and meta-analysis evaluated the effectiveness of strategies designed to enhance adherence to exercise-based interventions in individuals with LBP in terms of adherence as well as pain and functionality. METHODS: Randomized controlled trials including adults with non-specific LBP were eligible if they compared exercise-based interventions incorporating adherence-enhancing strategies versus exercise alone or usual care. Primary outcome was adherence; secondary outcomes were pain and functionality. Searches were conducted in PubMed, Embase, Web of Science, Cochrane Library, CINAHL, Scopus, and PEDro up to May 2026. Two reviewers independently screened studies, extracted data, and assessed risk of bias using the Cochrane RoB 2 tool. Random-effects meta-analyses were performed using standardized mean differences. Certainty of evidence was evaluated using the GRADE approach. RESULTS: Fourteen randomized controlled trials including 1233 participants were included. Risk of bias was low in six studies, with the remainder showing some concerns or high risk. For adherence outcomes, evidence showed no clear effect of adherence-enhancing strategies on either device-measured physical activity (SMD = 0.21, 95% CI -0.01 to 0.43; 3 trials, 320 participants; moderate-certainty evidence) or questionnaire-based adherence (SMD = 0.33, 95% CI -0.23 to 0.89; 4 trials, 377 participants; very low-certainty evidence). For pain and functionality, moderate certainty of evidence indicated small improvements favoring intervention groups in the medium term. CONCLUSIONS: Strategies to enhance adherence to exercise in LBP show uncertain effects on adherence but may provide small improvements in clinical outcomes in the medium term. Higher-quality trials are needed to strengthen the evidence base.

Adult

Reliability of resting heart rate measurements in atrial fibrillation.

BACKGROUND: Heart rate (HR) control in atrial fibrillation (AF) is commonly guided by resting HR measurements, usually with 12&#x2011;lead ECG or in-office pulse palpation. OBJECTIVES: We aimed to assess the reliability of resting HR measurements in AF patients with long-term ambulatory ECG and activity monitoring. METHODS: We included patients who had recorded a full-disclosure ambulatory ECG with a mobile cardiac telemetry device equipped with an accelerometer (PocketECG, MEDICALgorithmics, Poland), with at least 95% AF. Resting HR samples (&#x2264;20 per individual/day) were collected as 10-s daytime (8&#xa0;am to 8&#xa0;pm) measurements after &#x2265;10&#xa0;min of rest. These samples were compared to each individual's mean daytime resting HR. RESULTS: In 832 patients (median age 77 (interquartile range (IQR) 69-83) years, 42% women) with a median registration duration of 13&#xa0;days (IQR 7-22), the population mean daytime resting HR was 85 (&#xb1;15) beats per minute (bpm). A single resting HR differed from the mean daytime resting HR by a mean of &#xb1;10.4% (IQR 3.6-14.4%). When the mean daytime resting HR was &#x2265;110&#xa0;bpm, 29% of resting HR samples were&#xa0;<&#xa0;110&#xa0;bpm, and when the mean daytime resting HR was 80-109&#xa0;bpm,11% of samples were&#xa0;&#x2265;&#xa0;110&#xa0;bpm. Resting HR measurement variability decreased to 5.3% (IQR 1.9-7.5%) when four resting HR samples were averaged. CONCLUSION: In patients with AF, a single resting HR measurement often differs substantially from the mean daytime resting HR. When a precise measurement is clinically relevant, repeated resting HR sampling or ambulatory monitoring can address this measurement imprecision.

Humans

Impact of Contact Lens Use on Clinical Profile and Outcomes of Fungal Keratitis: An 8-Year Retrospective Study.

PURPOSE: To compare clinical characteristics, microbiological profiles, treatment strategies, and outcomes between contact lens-associated (CL) and noncontact lens-associated (non-CL) fungal keratitis. DESIGN: Retrospective, comparative clinical cohort study. METHODS: A review of culture-proven fungal keratitis treated at a tertiary referral center between 2018 and 2025 was conducted. Cases were categorized as CL or non-CL-associated. Demographic, clinical, microbiological, treatment, and outcome data were analyzed and compared between groups. RESULTS: Thirty-seven eyes were included, comprising 16 CL and 21 non-CL cases. CL users presented earlier than non-CL patients (median 7 vs 14 days, P = .007) and had fewer associated ocular risk factors (31% vs 81%, P = .001). Baseline visual acuity and infiltrate size did not differ significantly between groups. Candida species were isolated in 21% cases, Fusarium in 16% and Aspergillus in 8%. Fusarium (19% vs 13%) and Candida (24% vs 19%) infections were slightly more frequent in non-CL cases. Overall, filamentous fungi were the predominant organism group. Topical voriconazole was the most frequently used antifungal agent (78%). All CL-associated cases resolved with medical therapy alone, with a median time to resolution of 38 days (IQR 22-58). In contrast, 76% of non-CL cases resolved medically (median 42 days, IQR 32-76), while 23% required therapeutic keratoplasty (P = .04). Final visual acuity was comparable between groups (logMAR 0.2 vs 0.5, P = .56). CONCLUSION: Contact lens-associated fungal keratitis is characterized by earlier presentation and fewer underlying ocular comorbidities, with favorable outcomes achieved through medical therapy alone. Despite similar microbiological profiles and treatment approaches, noncontact lens-associated fungal keratitis more frequently follows a complicated course requiring surgical intervention.

Humans

Multidisciplinary mHealth Rehabilitation for Patients With Abdominal Cancer Who Are Receiving Chemoradiotherapy: Randomized Phase II Trial.

BACKGROUND: Concurrent chemoradiotherapy (CCRT) for abdominal cancer frequently induces muscle loss, weight loss, and malnutrition. OBJECTIVE: This exploratory randomized phase II trial evaluated whether a multidisciplinary, mobile health (mHealth)-based multimodal rehabilitation program could preserve handgrip strength and muscle mass in patients with abdominal cancer undergoing CCRT. METHODS: In this prospective, multicenter, randomized, open-label phase II trial (NCT05325554), 111 eligible patients with abdominal malignancies scheduled for CCRT were randomly assigned (1:1) to receive either multidisciplinary mHealth rehabilitation care (MRC; n=57) or standard care (SC; n=54). The MRC program was delivered by a dedicated multidisciplinary team using the AiNST mHealth platform and wearable heart rate monitors. The primary end point was handgrip strength at the end of CCRT (analyzed with analysis of covariance adjusting for baseline). Secondary end points were exploratory and analyzed without multiplicity adjustment; sensitivity analysis using false discovery rate (FDR) correction was performed. RESULTS: Between February 2022 and April 2023, 111 patients were enrolled. Adherence was high (n=93, 83.9% achieved exercise targets). After adjusting for baseline handgrip strength, the MRC group had significantly higher handgrip strength at the end of CCRT than the SC group (adjusted mean difference 4.87 kg, 95% CI 3.36-6.38; P<.001). Exploratory analyses of secondary end points (without multiplicity adjustment) showed that the MRC group also had better preservation of body weight (P=.005), skeletal muscle mass (P<.001), serum albumin (P=.009), prealbumin (P=.02), and lower rates of hematological toxicity (P<.05), as well as improved psychological status (distress thermometer [DT] and Hospital Anxiety and Depression Scale [HADS]) and nutritional scores (Nutritional Risk Screening 2002 [NRS-2002] and Patient-Generated Subjective Global Assessment [PG-SGA]) at the end of CCRT (all P<.05). All nominally significant secondary end points remained significant after FDR correction (q<.05). These findings are preliminary and should be interpreted with caution due to the open-label design, population heterogeneity, and exploratory secondary analyses. CONCLUSIONS: In this exploratory phase II trial, a multidisciplinary, mHealth-based multimodal rehabilitation program was associated with better preservation of handgrip strength, muscle mass, and nutritional status, as well as lower rates of certain treatment toxicities, compared with SC. However, definitive conclusions are limited by the open-label design, heterogeneity of tumor types, and short follow-up. Larger, blinded phase III trials are needed to confirm these findings.

Humans

Multicenter randomized effectiveness/implementation trial of a digital self-management support tool to improve the quality of life during adjuvant hormonal therapy for patients with early breast cancer: The HOPE trial.

BACKGROUND: For patients with hormone receptor (HR) positive early breast cancer (BC), adjuvant endocrine therapy (ET) represents the cornerstone of treatment. However, 75% of patients experience ET-related symptoms that negatively affect their quality of life (QOL). Despite their high prevalence, these symptoms are often underestimated and under-addressed during consultations. As a result, non-adherence to ET is common and remains a major barrier for optimal disease and survival outcomes. METHODS: National, prospective, randomized, open-label hybrid type 1 effectiveness/implementation trial conducted in France comparing a personalized digital health pathway plus standard of care (SoC) vs. SoC alone in patients with HR+ early BC reporting ET-related symptoms. 180 patients will be randomized 1:1 to receive either 12&#xa0;weeks of the digital health pathway or 12&#xa0;weeks of SoC. The intervention is anchored by the Resilience&#xa9; digital companion including remote symptom and needs assessment, an introductory nurse-navigator phone call, and access to personalized, symptom-specific online educational and self-management programs (physical activity, yoga, meditation or cognitive behavioral therapy). In both arms, patients will be invited to wear a wearable device to objectively monitor behavioral parameters. The primary endpoint is the ET symptoms scale of the European Organization for Research and Treatment of Cancer (EORTC) QLQ-BR45 over 12-weeks. Secondary endpoints include other QOL domains, self-reported ET adherence, eHealth literacy, self-efficacy, and evaluation of the implementation process. DISCUSSION: This study should provide evidence on the effectiveness and real-world implementation of a personalized digital health pathway to improve QOL in patients experiencing ET-related symptoms. TRIAL REGISTRATION: ClinicalTrials.gov NCT06781996; Protocol version 3.0.

Humans

Effectiveness of a Web-Based Educational eHealth Platform on Women's Health Literacy About Phthalate Exposure: Randomized Controlled Trial.

BACKGROUND: Phthalates are environmental endocrine-disrupting chemicals widely used in plastics, cosmetics, food packaging, and personal care products. Women may experience frequent exposure through everyday consumer and household products. Improving phthalate-related health literacy may support informed exposure-reduction decisions; however, conventional health education provides limited opportunities for repeated, interactive, and individually tailored learning. OBJECTIVE: This randomized controlled trial evaluated the effectiveness of an eHealth educational intervention (Phthalates Free) in improving women's overall and domain-specific phthalate-related health literacy and examined the association between platform engagement and health literacy outcomes. METHODS: A double-blind randomized controlled trial was conducted in the outpatient department of a regional teaching hospital in Taipei, Taiwan. A total of 114 women were randomly assigned to an intervention group (n=58) receiving a 6-month eHealth platform-based education program and a control group (n=56) receiving conventional paper-based education. Assessments were conducted at baseline (T0), 3 months (T1), and 6 months (T2). The Phthalate Health Literacy Scale (10 items; &#x3b1;=.90, content validity index=0.93) measured overall and domain-specific literacy (health care, disease prevention, and health promotion). Longitudinal outcomes were analyzed using generalized estimating equations based on all available observations according to participants' original randomized assignments, with adjustment for waist circumference and pregnancy history. Analysis of covariance (ANCOVA) was used to compare 6-month outcomes after adjustment for baseline scores. Platform engagement and perceived usability were assessed using back-end analytics and the System Usability Scale (SUS). RESULTS: At 6 months, the intervention group showed a significantly greater increase in total health literacy than the control group (+9.93 points, Wald &#x3c7;&#xb2;1=17.74; P<.001). Domain analyses revealed significant improvements in health care (+1.52; P=.001), disease prevention (+1.32; P=.001), and health promotion (+1.12; P=.001) domains. ANCOVA confirmed the between-group difference at T2 after adjusting for baseline scores (F1,109=11.43; P=.001; adjusted mean difference=7.15, 95% CI 2.96-11.34). Engagement analysis showed that high-engagement users (n=10) scored significantly higher in overall health literacy (t55=-3.00; P=.004) and all domains than general users. The SUS results (mean 84.7, SD 5.2; n=46, 79.3%) indicated high perceived usability. CONCLUSIONS: The Phthalates Free eHealth educational intervention significantly improved women's overall and domain-specific health literacy over 6 months. Higher platform engagement was associated with better health literacy outcomes. The intervention may serve as a practical adjunct to nurse-led education in outpatient and community settings by providing accessible, continuous, and evidence-based guidance on reducing phthalate exposure.

Humans

Perspectives of participating neurologists and study nurses - Mixed-methods process evaluation of a web-based program for relapse management in multiple sclerosis (POWER@M2).

BACKGROUND: Relapsing-remitting multiple sclerosis is a chronic inflammatory disease of the central nervous system and the leading cause of disability in young adults. In Germany, 90% of relapses are treated with high-dose intravenous glucocorticoids, despite limited evidence for long-term benefit and international preference for oral administration. Time constraints often hinder informed decision-making. The multicentre Randomized Controlled Trial (RCT) POWER@MS2 (N&#x202f;=&#x202f;160, 2020-2023), conducted at 18 German MS-centres, aimed to promote self-determined relapse management through a complex intervention (dialogue-based decision aid, nurse-led webinar, online-chat). OBJECTIVE: While RCTs demonstrate effectiveness, process evaluations are essential to understand implementation, mechanisms of impact and contextual factors. This study explored healthcare professionals' experiences and attitudes toward implementing relapse self-management and self-medication in clinical practice. METHODS: A mixed-methods process evaluation followed the UK Medical Research Council- framework. Quantitative data were collected via validated questionnaires at up to three time points and analysed descriptively. Interview guides were developed based on these results. Qualitative data from neurologist and study nurse interviews were thematically analysed. Results were triangulated using a joint display. RESULTS: Data were collected from 55 neurologists and 17 study nurses (quantitative) and from 7 neurologists and 4 nurses (qualitative) (2020-2024). Most neurologists opposed routine steroid use, reserving it for severe relapses. Some voiced concerns about self-management, but informed patients were generally viewed as capable of safe self-medication. Study nurses gave mixed feedback on the intervention, citing overload and improved guidance. CONCLUSION: Clinicians showed openness toward implementing the intervention. Enhancing accessibility and addressing specific concerns may support broader adoption.

Humans

Digital Mindfulness Intervention for Pregnant Women With Affective Disorders and Acute Stress Reactions: Prespecified Secondary Analysis of a Randomized Controlled Trial.

BACKGROUND: Pregnant women with ICD-10 (International Statistical Classification of Diseases, Tenth Revision) affective or stress-related disorders face an elevated risk of perinatal depression and anxiety, yet evidence on digital nonpharmacologic interventions for this population remains limited. OBJECTIVE: This study evaluated the effectiveness of an 8-week digital mindfulness-based intervention (eMBI) compared with treatment as usual (TAU) among pregnant women with ICD-10 affective or stress-related disorders participating in a randomized controlled trial (RCT). METHODS: This prespecified secondary analysis was conducted within a multicenter RCT in Baden-W&#xfc;rttemberg, Germany. Pregnant women aged 18 years and older with elevated depressive symptoms (Edinburgh Postnatal Depression Scale [EPDS]>9) and ICD-10-diagnosed affective or stress-related disorders were randomized 1:1 to eMBI or TAU. The intervention consisted of 8 weekly app-based mindfulness sessions (45 min each) delivered during gestational weeks 29-36, with no direct therapist contact. The primary outcome was continuous depressive symptom severity measured with the EPDS at 4-6 weeks post partum. Secondary outcomes included the EPDS at 6 months post partum, generalized anxiety (State-Trait Anxiety Inventory-State [STAI-S], State-Trait Anxiety Inventory-Trait [STAI-T]), and Pregnancy-Related Anxiety Questionnaire-Revised (PRAQ-R). Analyses followed the intention-to-treat (ITT) principle, using mixed models for repeated measures and multiple imputation. RESULTS: Of the 5299 screened women, 147 met the inclusion criteria for this subgroup analysis (intervention group [IG] had n=73 women and control group had n=74 women). Groups were comparable at baseline. The IG showed significantly greater reductions in EPDS scores at gestational week 34 (&#x394;=-2.21, P=.01), week 36 (&#x394;=-3.25, P=.01), and 4-6 weeks post partum (&#x394;=-4.81, P=.007). Treatment effects remained robust under conservative missing-data assumptions. At 4-6 weeks post partum, a higher proportion of participants in the IG achieved clinically meaningful improvement (31/73, 42.5% vs 21/74, 28.4%; adjusted odds ratio 1.56, 95% CI 1.19-2.05; P=.001). Anxiety outcomes followed a similar pattern, whereas pregnancy-related anxiety did not differ between groups. CONCLUSIONS: In this prespecified subgroup of pregnant women with ICD-10 affective or stress-related disorders, the eMBI was associated with clinically meaningful reductions in depressive symptoms from late pregnancy to 4-6 weeks post partum. Effects at 6 months post partum were attenuated and less stable across missing-data assumptions. These findings support eMBIs as a scalable, nonpharmacological adjunct to perinatal mental health care for women with affective or stress-related disorders, while confirmation in adequately powered trials with strategies to reduce postpartum attrition is warranted.

Humans

Compliance With Ecological Momentary Assessment Among Patients With Cancer: Systematic Review and Meta-Analysis.

BACKGROUND: Patients with cancer often experience substantial fluctuations in psychological states during disease management. Traditional research tools are limited in capturing these dynamic changes in real time, constraining clinicians' understanding of patients' true conditions. Ecological momentary assessment (EMA) enables high-frequency, real-time data collection, providing patient-reported data with greater ecological validity. However, the effectiveness of EMA studies critically depends on patient compliance, and reported compliance rates vary widely, with a lack of systematic quantitative synthesis. OBJECTIVE: This study aims to systematically review and quantitatively analyze compliance with EMA among patients with cancer, and to examine whether EMA design characteristics were associated with compliance. METHODS: Web of Science, PubMed, Embase, Cochrane Library, CINAHL, PsycINFO, CNKI, and Wanfang databases were searched for literature published up to April 30, 2026. Compliance was defined as completed prompts divided by delivered prompts. Single-group proportions were pooled using logit transformation and random-effects models with the Hartung-Knapp-Sidik-Jonkman adjustment. Prediction intervals were calculated to describe the expected distribution of compliance in future comparable settings. Subgroup analyses, univariable meta-regressions, leave-one-out sensitivity analyses, and tests for small-study effects were performed. Risk of bias was assessed using the Joanna Briggs Institute Critical Appraisal Checklist for Studies Reporting Prevalence Data, methodological reporting quality was assessed using a modified Checklist for Reporting EMA Studies, and certainty of evidence was evaluated using the Grading of Recommendations Assessment, Development, and Evaluation approach. RESULTS: Twenty-three studies involving 13,565 participants were included. The pooled compliance rate was 78.55% (95% CI 73.48%-82.87%), with a prediction interval of 48.59%-93.41%. Subgroup analyses identified no robust differences across study characteristics. Although study length showed a statistically significant subgroup test, the result was not stable after excluding singleton categories. Meta-regression analyses similarly found no significant linear associations for study length, prompts per day, items per prompt, or assessment window. Leave-one-out analyses showed that no single study drove the pooled estimate. Regarding the risk of bias, 2 studies were judged as low, while 21 were judged as moderate risk. Quality scores ranged from 6.5 to 9.0, and the certainty of evidence for the pooled compliance rate was rated as very low according to the Grading of Recommendations Assessment, Development, and Evaluation approach. CONCLUSIONS: Overall compliance with EMA among patients with cancer was moderate to high, suggesting that repeated real-world assessment may be feasible in oncology research settings. Nevertheless, the very high heterogeneity, wide prediction interval, and very low certainty of evidence indicate that compliance is context-dependent. The pooled estimate should therefore be interpreted as an approximate benchmark rather than a universal expected rate. Future oncology EMA studies should use standardized compliance denominators, report missing prompts transparently, and prospectively evaluate patient-centered design strategies that reduce burden while preserving data quality.

Humans

Effects of exercise on muscle strength and characteristics in rheumatic diseases and sarcopenia: Protocol for the Care for Muscle (C4M) Study.

OBJECTIVE: Muscle weakness is prevalent in rheumatoid arthritis (RA), osteoarthritis (OA) and sarcopenia (SARC). Endurance exercises may improve mitochondrial function and oxidative capacity, while strength exercises are thought to stimulate myofibrillar protein synthesis. This study aims to compare the effects of strength and endurance exercise and explore the association between muscle characteristics and exercise outcomes in patients with RA, OA and SARC. We hypothesize that responses to endurance and strength exercises in patients with muscle weakness are influenced by intramuscular pathology including muscle morphology, mitochondrial function, and systemic inflammation, based on their disease pathology, potentially requiring personalized training schedules. METHODS: This two-arm, parallel-group exploratory trial will enroll 69 patients (23 RA, 23 OA, 23 SARC), randomized to endurance (n&#x2009;=&#x2009;35) or muscle strength exercises (n&#x2009;=&#x2009;34), using minimization to balance disease type and gender. The 8-week intervention includes two supervised sessions per week using a controlled cable pulley device (Reforter&#x2122;) and fitness equipment, plus one weekly home-based session. The primary outcome is isokinetic muscle strength (peak torque), measured with the Biodex system&#xae;. Secondary outcomes include muscle morphology, mitochondrial function, systemic inflammation and muscle endurance (by Biodex and 6 Minute Walk test). Muscle morphology will be assessed via 3D ultrasound imaging of the vastus lateralis. Mitochondrial function will be analyzed using high-resolution respirometry on muscle biopsies. Systemic inflammation will be measured using multiplex assays or ELISA on serum samples. DISCUSSION: This study will explore differential responses to muscle endurance and muscle strength exercises in patients with RA, OA, and SARC, offering novel insights into the molecular mechanisms of muscle weakness. The findings may help identify potential mechanisms underlying variability in exercise response and provide effect size estimates to guide future confirmatory studies and more targeted exercise interventions. TRIAL REGISTRATION: ClinicalTrials.gov NCT06480643 (date of registration28-06-24).

Humans

Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis.

BACKGROUND: Colorectal cancer remains a leading cause of death despite being largely preventable through polypectomy. AI systems designed to enhance polyp detection during colonoscopy have shown promise, but the extent to which they improve detection of different-sized polyps remains unclear. OBJECTIVE: This study compared the size-stratified efficacy of AI-assisted colonoscopy vs standard colonoscopy using the Hartung-Knapp-Sidik-Jonkman (HKSJ) method, and generated exploratory rankings while acknowledging all cross-platform comparisons are indirect. METHODS: This systematic review and network meta-analysis (NMA) searched PubMed, Embase, Cochrane CENTRAL, and Web of Science from inception to July 25, 2026, supplemented by citation searching. We included randomized controlled trials (RCTs) comparing AI-assisted vs standard colonoscopy in adults (&#x2265;18 years of age), reporting mean polyp detection counts stratified by size (&#x2264;5 mm, 6-9 mm, and &#x2265;10 mm). Two reviewers screened studies, extracted data, and assessed risk of bias using the Cochrane Risk of Bias 2.0. We conducted frequentist NMA using the HKSJ method with restricted maximum likelihood estimation, calculated 95% prediction intervals (PIs), and assessed heterogeneity using I2 and &#x3c4;2. Certainty of evidence was rated using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) framework. RESULTS: A total of 13 RCTs (4156 participants) compared 8 AI systems to standard colonoscopy, forming a network without direct AI comparisons. For diminutive polyps (&#x2264;5 mm), AI showed a modest advantage (standardized mean difference [SMD] 0.21, 95% CI 0.07 to 0.35, 95% PI -1.12 to 1.54), but substantial heterogeneity (I2=86.6%) and wide PI crossing the null indicated high uncertainty. EndoScreener showed the most consistent evidence (SMD 0.36, 95% CI 0.18-0.54). For small and large polyps, effects were minimal (SMD 0.02, 95% CI -0.02 to 0.06, 95% PI -0.03 to 0.07; SMD 0.01, 95% CI 0.00-0.02, 95% PI -0.01 to 0.03). GRADE certainty was very low for diminutive polyps and low for small and large polyps. Sensitivity analysis excluding Tianjin YuJin did not materially change findings. CONCLUSIONS: AI may modestly enhance diminutive polyp detection, but effects on small and large polyps are minimal, with no platform superiority. Given very low to low certainty, findings are hypothesis-generating. This exploratory NMA provides size-stratified comparisons that can inform future head-to-head trial design. Unlike prior reviews aggregating all polyp sizes, we show the overall AI benefit is driven by diminutive polyp detection, providing a framework for targeted deployment-prioritizing AI for diminutive polyp screening, with limited value for larger lesions. Head-to-head trials are urgently needed. TRIAL REGISTRATION: PROSPERO International Prospective Register of Systematic Reviews CRD420251266932; https://www.crd.york.ac.uk/PROSPERO/view/CRD420251266932.

Colonoscopy

Cost-Effectiveness of Electronic Patient-Reported Outcome Measure Interventions in Cancer: Systematic Review and Parameter Extraction for Economic Modeling.

BACKGROUND: Complex digital interventions that integrate electronic patient-reported outcome measures (ePROM) into clinical practice in cancer have the potential to improve quality of life, increase survival, and reduce health resource use and costs. Such systems can help patients with cancer self-manage chemotherapy symptoms, reduce clinicians' workloads through automated decision support, and resolve problems earlier. However, more research on the cost-effectiveness of ePROM monitoring is needed. OBJECTIVE: This paper comprises two complementary components: (1) a systematic literature review summarizing and evaluating the quantitative and qualitative evidence related to the cost-effectiveness of ePROM monitoring and (2) a health economic model parameter extraction. We also conducted supplementary targeted searches and scoping to provide context to our findings. METHODS: We searched Ovid (including MEDLINE and Embase), Scopus, and the International Health Technology Assessment Database for original English-language papers published on or before March 2025 using search strings that combined terms related to ePROMs, health economics, and cancer/oncology. We included papers reporting health economic-related outcomes for ePROM interventions designed for adult cancer populations and excluded screening tools and conference abstracts. RESULTS: We included 34 publications from 27 unique studies and identified and analyzed 26 ePROM-integrated interventions within these. Most (23/26) of the included interventions explicitly described some form of alert handling and automated decision support based on remote ePROM monitoring. Of the 34 publications, 5 presented full cost-effectiveness analysis results, of which 3 were highly uncertain and lacked clear differences in costs and health outcomes between ePROMs and standard care; conversely, 2 presented strong evidence of cost-effectiveness due to quality-of-life improvements, reduced hospitalizations, and potentially more autonomy in health-related travel (eg, ePROM-monitored patients can drive or walk to the hospital instead of using taxis or ambulances). A further 5 publications reported partial health economic results (eg, cost-consequence and budget impact), of which 1 detected no difference in strategies; in contrast, 4 reported lower health resource use and costs of ePROMs, mainly due to hospitalization reductions. Overall, 12 of the 27 studies included a qualitative component but mostly focused on user experience and design-related themes; only 2 of these addressed economic-specific themes (eg, changes in workflow and resource use due to ePROM implementation and integration), indicating some potential for time saving due to ePROM monitoring. CONCLUSIONS: Some ePROM-integrated interventions demonstrated cost-effectiveness in cancer care, but the evidence base remains limited. Where evidence does exist, cost-effectiveness appears driven by reduced hospitalization and improved quality of life. Qualitative research within the included studies rarely addressed economic questions. We provide a detailed parameter extraction for use in future economic modeling and recommend research priorities, including quantitative mapping of ePROM symptom data onto health resource use patterns, and qualitative work exploring how ePROM implementation affects clinical workloads and patient-perspective costs.

Humans

Health Literacy and Capecitabine Adherence in a Remote Monitoring Pilot Trial for Breast Cancer: Post Hoc Exploratory Analysis.

BACKGROUND: Oral anticancer therapy enables convenient, home-based cancer care but can introduce adherence challenges, particularly with complex dosing schedules. Capecitabine is commonly used in breast cancer, often as adjuvant therapy or in advanced disease, and typically requires twice-daily dosing on cyclical schedules, increasing the risk of missed or incorrect doses. Low health literacy may exacerbate these difficulties, and emerging remote monitoring tools may help close this gap. OBJECTIVE: In this post hoc exploratory analysis, we evaluated whether health literacy (1) was associated with capecitabine adherence and (2) modified a remote monitoring intervention's effectiveness. METHODS: We conducted post hoc analyses of a 2-arm pilot trial that randomized women with breast cancer treated with capecitabine to enhanced usual care (EUC) or remote patient monitoring (RPM). Adherence was captured with a smart pill bottle, Nomi by SMRxT, that recorded dose timing and quantity. Participants in the RPM group received messages for missed or incorrect doses and weekly symptom assessments. Incorrect or missed doses and severe symptoms triggered alerts to the oncologist. Health literacy was assessed at enrollment. To evaluate moderation, we used linear regression with an interaction term (health literacy &#xd7; intervention arm) predicting adherence (proportion of days). Marginal effects quantified differences in adherence by study arm and health literacy. RESULTS: Among 28 participants (EUC, n=15 and RPM, n=13), 9 (32.1%) had lower health literacy, 16 (57.1%) identified as Black, 10 (35.7%) identified as White, and 15 (53.6%) had income below 200% of the federal poverty level. In the regression model, the health literacy &#xd7; randomized group interaction did not reach statistical significance (-16.3 percentage points, 95% CI -35.5 to 2.9; P=.09). Predicted adherence among lower health literacy participants was 87.5% in the RPM group and 65.5% in the EUC group (difference: +22.1 percentage points, 95% CI 6.2-37.9; P=.008). Among participants with higher health literacy, adherence was 89.9% in the RPM group and 84.1% in the EUC group (difference: +5.7 percentage points, 95% CI -5.2 to 16.7; P=.29). Within the EUC group, predicted adherence was 18.6 percentage points lower among those with lower versus higher health literacy (95% CI -32.4 to -4.9; P=.01); within the RPM group, this difference was 2.3 percentage points lower among those with lower versus higher health literacy (95% CI -15.8 to 11.1; P=.73). CONCLUSIONS: In this post hoc exploratory analysis, the estimated difference in capecitabine adherence between the RPM and EUC groups was larger among participants with lower health literacy. Although the formal interaction test was not statistically significant, the magnitude and direction of the observed difference support further investigation of RPM as a potential approach to improve adherence among patients facing health literacy-related adherence barriers. Larger, prospectively powered studies are needed to confirm these findings and evaluate downstream clinical outcomes.

Humans