Search PubMedSearch

SEARCH · Search PubMed

Results for “Lung Volume Measurements”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

761 records · Page 11Linked to original sources

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

The impact of absolute change in tibiofemoral morphology on patient reported outcome measures post total knee arthroplasty.

BACKGROUND: Reconstructing knee morphology and alignment is important for outcomes post total knee arthroplasty (TKA). Personalised alignment strategies are proposed to improve outcomes by replicating native alignment. However, how change in morphology affects patient outcomes is unclear. This study aimed to investigate the relationship between absolute change in morphological measures post-TKA and patient reported outcome measures (PROMs). METHOD: An observational analysis of a randomised clinical trial was conducted. Participants received preoperative and postoperative CT scans and completed PROMs at six-months post-TKA. Absolute change in hip-knee-ankle angle, medial proximal tibial angle, lateral distal femoral angle, non-weightbearing joint line convergence angle, tibial and femoral rotation, and posterior tibial slope (PTS) were calculated. PROMs included visual analogue scales of pain and satisfaction (0-100), Oxford Knee Score, Forgotten Joint Score, and the Kujala Score. Regression and principal component (PCA) analyses investigated relationships between PROMs and change in morphology. RESULTS: Sixty-one participants were included for analysis (61% women, age 66.9&#xa0;&#xb1;&#xa0;9.1 [mean&#xa0;&#xb1;&#xa0;SD] years, BMI 32.8&#xa0;&#xb1;&#xa0;6.8&#xa0;kg/m2). The PCA demonstrated coronal, axial, and sagittal plane measures were interdependent, with over 65% of variability driven by change in tibial rotation (PC1) and the PTS (PC2). The regression analysis showed no relationships between morphological change and PROMs postoperatively. CONCLUSION: Tibiofemoral morphology was interrelated across coronal, axial, and sagittal planes. However, this study suggests absolute morphological change had minimal impact upon PROMs at six-months post-TKA. Future research should clearly distinguish between osteoarthritic versus prearthritic alignment and consider the influence of soft-tissue releases upon PROMs.

Humans

Reliability of resting heart rate measurements in atrial fibrillation.

BACKGROUND: Heart rate (HR) control in atrial fibrillation (AF) is commonly guided by resting HR measurements, usually with 12&#x2011;lead ECG or in-office pulse palpation. OBJECTIVES: We aimed to assess the reliability of resting HR measurements in AF patients with long-term ambulatory ECG and activity monitoring. METHODS: We included patients who had recorded a full-disclosure ambulatory ECG with a mobile cardiac telemetry device equipped with an accelerometer (PocketECG, MEDICALgorithmics, Poland), with at least 95% AF. Resting HR samples (&#x2264;20 per individual/day) were collected as 10-s daytime (8&#xa0;am to 8&#xa0;pm) measurements after &#x2265;10&#xa0;min of rest. These samples were compared to each individual's mean daytime resting HR. RESULTS: In 832 patients (median age 77 (interquartile range (IQR) 69-83) years, 42% women) with a median registration duration of 13&#xa0;days (IQR 7-22), the population mean daytime resting HR was 85 (&#xb1;15) beats per minute (bpm). A single resting HR differed from the mean daytime resting HR by a mean of &#xb1;10.4% (IQR 3.6-14.4%). When the mean daytime resting HR was &#x2265;110&#xa0;bpm, 29% of resting HR samples were&#xa0;<&#xa0;110&#xa0;bpm, and when the mean daytime resting HR was 80-109&#xa0;bpm,11% of samples were&#xa0;&#x2265;&#xa0;110&#xa0;bpm. Resting HR measurement variability decreased to 5.3% (IQR 1.9-7.5%) when four resting HR samples were averaged. CONCLUSION: In patients with AF, a single resting HR measurement often differs substantially from the mean daytime resting HR. When a precise measurement is clinically relevant, repeated resting HR sampling or ambulatory monitoring can address this measurement imprecision.

Humans

Measuring Coping Strategies in Daily Life: A Systematic Review of Experience Sampling Methodology and Daily Diary Studies.

Advances in daily diary methods and experience sampling method (ESM) have improved the study of coping strategies in daily life and their role in shaping health and well-being. In this review, we examine study designs, measurement approaches, and analytical practices used to investigate coping in natural contexts. We performed a systematic review of studies published before 5 December 2025 that used daily diary or ESM to measure coping strategies over multiple days or moments. Studies were examined with regard to sampling schemes, assessment frequency and duration, measurement of coping strategies, incorporation of stressor appraisals, and analytic techniques used to model coping processes. Fifty-five studies met the inclusion criteria. Results indicated that 80% employed end-of-day diary designs, generally lasting 1-3 weeks, whereas higher-frequency ESM protocols were less common and ranged 2-14&#xa0;days. Coping strategies were often assessed using abbreviated or single-item measures, frequently adapted from established questionnaires. Many studies incorporated appraisals such as perceived stressor intensity or controllability, enabling tests of coping flexibility. Multilevel modelling was the dominant analytic approach, allowing researchers to distinguish within-person dynamics from between-person differences. However, analyses were predominantly concurrent, and temporally ordered models remained comparatively rare. Overall, the literature demonstrates substantial progress in capturing coping in everyday contexts, yet heterogeneity in measurement and limited use of temporal modelling constrain cumulative knowledge about the temporal links between coping and psychological and physiological health outcomes. Future research would benefit from greater alignment between theoretical assumptions, assessment strategies, and analytic methods.

Humans

Proprioception Training and Surrogate Outcomes: A Systematic Review of Definitions, Measures, and Effectiveness Claims.

BACKGROUND: "Proprioception training" is widely advocated in rehabilitation and sports practice, yet the term encompasses heterogeneous constructs, interventions, and outcomes. Many trials infer proprioceptive benefits from surrogate outcomes (balance, strength, or pain) rather than direct psychophysical indices. OBJECTIVE: We aimed to examine how proprioception is defined and measured, and how improvement is claimed, in randomized controlled trials. METHODS: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020, PubMed, Scopus, and Web of Science were searched to October 2025. Eligible randomized controlled trials explicitly described interventions as "proprioceptive" or "sensorimotor training" and reported at least one proprioceptive outcome, either direct (e.g., joint position reproduction, threshold to detection of passive motion, active movement extent discrimination) or indirect (e.g., sway, balance). Methodological quality was appraised with the Physiotherapy Evidence Database (PEDro) scale and risk of bias using the Cochrane Risk of Bias 2 (RoB 2) tool. RESULTS: Fifty-one randomized controlled trials (n&#x2009;=&#x2009;2319) were included. Comparative synthesis showed that improvements inferred from surrogate outcomes were more frequent and often larger than improvements observed in direct psychophysical measures. Directly targeted practice, angle specific, attentionally demanding, and aligned with the measured proprioceptive submodality and task construct, produced the most consistent benefits in position-reproduction accuracy/error, movement-detection sensitivity, or discrimination performance, depending on the outcome assessed. In contrast, multimodal regimens (balance, strengthening, taping, manual therapy) commonly improved balance, pain, strength, or function without comparably consistent evidence of enhanced direct psychophysical proprioceptive function. CONCLUSIONS: Specific psychophysical components of proprioceptive function appear modifiable, but only when training explicitly targets the sensory construct measured. The field remains conceptually diffuse, with frequent conflation of sensorimotor performance and proprioception. Progress depends on defining proprioceptive submodalities a priori, privileging validated psychophysical outcomes over surrogate outcomes, and aligning intervention content with measurement to substantiate true perceptual learning rather than generic motor adaptation.

Journal Article

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Patient-reported outcome measures within European cohorts of severely injured patients: a systematic review and meta-analysis.

PURPOSE: Severe injury affects multiple health-related domains, yet comprehensive European data on patient-reported outcomes remain limited. This systematic review and meta-analysis evaluates patient-reported outcome measures (PROMs) use and outcomes in severely injured European cohorts. METHODS: A systematic search of four databases up to October 14, 2025, identified European studies from 2000 onward reporting PROMs in severely injured patients. Severe injury was defined as an Injury Severity Score&#x2009;&#x2265;&#x2009;16, Glasgow Coma Scale&#x2009;&#x2264;&#x2009;8, intensive care unit admission, spinal cord injury, traumatic amputations, or pelvic fractures. Two reviewers independently screened records, with disagreements resolved by a third reviewer. Meta-analysis was performed when &#x2265;&#x2009;3 studies reported comparable PROMs at similar follow-up timepoints. RESULTS: Of 2,479 studies, 119 were included. Most cohorts originated from the Netherlands (26%), Norway (18%), and Germany (16%). General severely injured cohorts were most frequently studied (61%), followed by traumatic brain injury (17%), and spinal cord injury (15%). In total, 94 PROMs were used across 277 follow-up timepoints. Health-related quality of life was assessed most frequently (63%), after that anxiety/depression (14%), post-traumatic stress (9%), and social functioning (6%). At one year follow-up, the pooled EuroQol-5D-3&#xa0;L index score was 0.70 (95% CI 0.62-0.77) and VAS score was 68 (95% CI 60-75), indicating persistent impairment compared to population norms. CONCLUSION: Severely injured patients show persistent impairments with incomplete restoration of pre-injury functioning. Despite increased PROMs use, heterogeneity in selection and outcome reporting limits comparability, underscoring the need for standardised PROM assessment to improve outcome evaluation after severe injury.

Humans

Cost-Effectiveness of Electronic Patient-Reported Outcome Measure Interventions in Cancer: Systematic Review and Parameter Extraction for Economic Modeling.

BACKGROUND: Complex digital interventions that integrate electronic patient-reported outcome measures (ePROM) into clinical practice in cancer have the potential to improve quality of life, increase survival, and reduce health resource use and costs. Such systems can help patients with cancer self-manage chemotherapy symptoms, reduce clinicians' workloads through automated decision support, and resolve problems earlier. However, more research on the cost-effectiveness of ePROM monitoring is needed. OBJECTIVE: This paper comprises two complementary components: (1) a systematic literature review summarizing and evaluating the quantitative and qualitative evidence related to the cost-effectiveness of ePROM monitoring and (2) a health economic model parameter extraction. We also conducted supplementary targeted searches and scoping to provide context to our findings. METHODS: We searched Ovid (including MEDLINE and Embase), Scopus, and the International Health Technology Assessment Database for original English-language papers published on or before March 2025 using search strings that combined terms related to ePROMs, health economics, and cancer/oncology. We included papers reporting health economic-related outcomes for ePROM interventions designed for adult cancer populations and excluded screening tools and conference abstracts. RESULTS: We included 34 publications from 27 unique studies and identified and analyzed 26 ePROM-integrated interventions within these. Most (23/26) of the included interventions explicitly described some form of alert handling and automated decision support based on remote ePROM monitoring. Of the 34 publications, 5 presented full cost-effectiveness analysis results, of which 3 were highly uncertain and lacked clear differences in costs and health outcomes between ePROMs and standard care; conversely, 2 presented strong evidence of cost-effectiveness due to quality-of-life improvements, reduced hospitalizations, and potentially more autonomy in health-related travel (eg, ePROM-monitored patients can drive or walk to the hospital instead of using taxis or ambulances). A further 5 publications reported partial health economic results (eg, cost-consequence and budget impact), of which 1 detected no difference in strategies; in contrast, 4 reported lower health resource use and costs of ePROMs, mainly due to hospitalization reductions. Overall, 12 of the 27 studies included a qualitative component but mostly focused on user experience and design-related themes; only 2 of these addressed economic-specific themes (eg, changes in workflow and resource use due to ePROM implementation and integration), indicating some potential for time saving due to ePROM monitoring. CONCLUSIONS: Some ePROM-integrated interventions demonstrated cost-effectiveness in cancer care, but the evidence base remains limited. Where evidence does exist, cost-effectiveness appears driven by reduced hospitalization and improved quality of life. Qualitative research within the included studies rarely addressed economic questions. We provide a detailed parameter extraction for use in future economic modeling and recommend research priorities, including quantitative mapping of ePROM symptom data onto health resource use patterns, and qualitative work exploring how ePROM implementation affects clinical workloads and patient-perspective costs.

Humans

Long-term outcomes of surgical correction of ventral penile curvature in children: Patient-reported measures, surgical results, and decisional regret.

INTRODUCTION: There is a dearth of data on long-term outcomes, including patient-reported outcomes (PROMs), decisional regret, and complication rates for surgical correction of isolated ventral penile curvature in childhood. PATIENTS AND METHODS: Twenty-six children treated for ventral curvature between 1993 and 2008 were identified; 24 met inclusion criteria (isolated ventral curvature without hypospadias or need for urethral reconstruction). Surgical correction consisted of degloving alone or degloving with Nesbit-like dorsal plication when residual curvature >20&#xb0; persisted after degloving. PROMs were collected via pre-mailed validated questionnaires after puberty: Danish Prostatic Symptom Score (DAN-PSS) for LUTS, Erection Hardness Score (EHS) for erectile function, Penile Perception Score (PPS) for cosmetic perception, and items assessing decisional regret and perceived appropriateness of surgical timing. RESULTS: Curvature was corrected intraoperatively in all 24 patients. Twelve underwent degloving alone and 12 required additional dorsal plication. During long-term follow-up (median 14.2 years), one patient (4%) underwent re-operation for residual curvature, and three (13%) underwent cosmetic revisions; two (8%) underwent cystoscopy for flow concerns. 71% returned PROMs at a median age of 16.2 years. LUTS were uncommon, with low bother scores. Erectile function was favorable: 87% (13/15) reported EHS 4 and 93% (14/15) reported ejaculation. Cosmetic outcomes were favorable, with PPS dissatisfaction rates comparable to controls. Two patients reported dissatisfaction with overall appearance, and one with residual subjective curvature. No patient expressed decisional regret, and 88% felt timing of surgery was appropriate. CONCLUSION: Early surgical correction of isolated ventral penile curvature using degloving with or without dorsal plication provided durable anatomical correction and favorable long-term functional and cosmetic outcomes. These findings support early intervention as an effective approach with sustained patient-perceived benefits.

Humans

Technology choice, glycemic control and patient-reported outcome measures in adults with type 1 diabetes: A randomized crossover trial comparing a smart insulin pen with an automated insulin delivery system (EBIACE-1).

AIMS: To compare glycemic outcomes and patient-reported outcome measures (PROMs) between smart insulin pens (SIP) and an automated insulin delivery (AID) system in adults with type 1 diabetes (T1D), and to identify individuals able to maintain near-optimal glycemic control using SIP. METHODS: EBIACE-1 was a randomized, open-label, crossover trial including 31 adults with T1D. Participants received SIP (InPen&#x2122;) and AID (MiniMed&#x2122; 780G) for 6&#xa0;months each. Co-primary outcomes were time in range (TIR 70-180 mg/dL) and HbA1c. Treatment effects were assessed using longitudinal models in intention-to-treat (ITT) and per-protocol (PP) analyses. Predictors of near-optimal glycemic control with SIP were evaluated using multivariable logistic regression. RESULTS: AID improved glycemic control versus SIP, with higher TIR (81&#xa0;% vs 66&#xa0;%; +15&#xa0;%, 95&#xa0;% CI 10-19; P&#xa0;<&#xa0;0.001) and lower HbA1c (6.9&#xa0;% [52&#xa0;mmol/mol] vs 7.3&#xa0;% [56&#xa0;mmol/mol]; -0.4&#xa0;%, 95&#xa0;% CI&#xa0;-&#xa0;0.6 to&#xa0;-&#xa0;0.3; P&#xa0;<&#xa0;0.001). Near-optimal glycemic control with SIP was achieved by 12 of 26 participants (46&#xa0;%). In exploratory analyses, higher baseline diabetes-related life interference was associated with a lower probability of achieving this outcome. CONCLUSIONS: AID provides superior glycemic control, although nearly half of participants achieved near-optimal control with SIP, supporting a personalized approach to technology selection.

Adult

Understanding specificity in immune-brain pathways: A systematic review of differential associations between individual cytokines and brain structure and function measured through magnetic resonance imaging in humans.

Research shows that cytokines are associated with psychiatric disorders, including major depression, and multiple aspects of brain structure and function. Accumulating data suggest that different cytokines may have unique profiles of biological activity, particularly in their neuromodulatory roles, but it is currently unclear whether they have unique associations with specific neural circuits in humans. In this paper, we systematically review magnetic resonance imaging studies conducted with depressed or healthy control human participants under age 65 that examine associations between peripheral cytokines and brain structure and function, with the goal of evaluating evidence for the specificity of these cytokine-brain associations. We find that across multiple measures of brain structure and function, the majority of studies reviewed reported unique associations between individual cytokines and brain outcomes. A synthesis of findings across studies also suggests a preliminary hypothesis of specific associations of interleukin-6 levels in circulation with the default mode network and tumor necrosis factor-alpha with the salience network, which could be tested in future research. We conclude the review with future directions for research that can strengthen understanding of these associations.

Humans

Comparison of black carbon measurements using filter-specific reference transmittance to those using lab blanks or an average of unloaded filters.

Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). We analyzed 5,379 15&#x2009;mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial to assess the influence that different methods of I0 estimations have on eBC measures. We compared eBC measurements using filter-specific I0 values (Method 1) to those using three other methods of I0 estimation: the lab blank scan from a given session (Method 2), the average of all pre-sample filter scans (Method 3), and the average of all lab blank filter scans (Method 4). We assessed the agreement between Method 1 and the alternative methods using Bland-Altman analysis. We also assessed the relationship between Method 1 and the alternative methods across the complete measurement range and after stratifying exposure data into quartiles according to Method 1 eBC exposures. The mean (SD) personal eBC exposure for Method 1 was 7.8&#x2009;&#x3bc;g/m3 (5.9), and exposures ranged from 1.3 to 46.8&#x2009;&#x3bc;g/m3. Compared to Method 1, eBC using Methods 2, 3, and 4 were higher by 0.7&#x2009;&#x3bc;g/m3, 0.1&#x2009;&#x3bc;g/m3, and 0.7&#x2009;&#x3bc;g/m3, respectively. The performances of linear regression models between Method 1 and all other methods were moderate to strong (R2 range: 0.42-0.93) in the second, third, and fourth quartiles; however, the models in the first quartile (eBC range: 1.3-2.9&#x2009;&#x3bc;g/m3) performed poorly (R2&#x2009;=&#x2009;0.25-0.26), with error approximately 25% of the mean. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.Implications: Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). To assess the influence that different methods of I0 estimations have on eBC measures, we analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.

Soot

Measurement of low-density lipoprotein cholesterol and other circulating lipids in Brazil: a systematic literature review.

Accurate laboratory assessment of circulating lipids underpins cardiovascular risk stratification, yet clinical interpretation depends not only on the assays but on the formula chosen to estimate low-density lipoprotein cholesterol (LDL-C). This review integrates the 2019-2025 evidence on laboratory methods for triglycerides (TG), total cholesterol (TC), and high-density lipoprotein cholesterol (HDLC), and on the formulas estimating LDL-C, VLDL-C, and non-HDL cholesterol, to determine how these should be measured, reported, and harmonized in Brazil, where lipid thresholds are adapted from international consensus. A PRISMA 2020 systematic search (PROSPERO CRD420251241064) of PubMed/MEDLINE, Scopus, SciELO, LILACS, Web of Science, and Embase retrieved 57,915 records; after removing 38,210 duplicates, 19,705 titles/abstracts were screened, 312 full texts assessed, and 25 sources included. Enzymatic colorimetric assays remain standard for TG, TC, and HDLC. For LDL-C, Martin/Hopkins classifies more accurately than Friedewald (89.6% vs 83.2% correct categorization in 5,051,467 patients), particularly at high TG and low LDL-C, while Sampson/NIH and modified Sampson/NIH extend reliable estimation into hypertriglyceridemia and very low LDL-C; direct measurement is reserved for TG beyond the validated range. Although the review centers on the Friedewald, Martin/Hopkins, and Sampson/NIH families that dominate guideline practice, other published equations exist and are addressed in context. In Brazil, atherogenic-lipid thresholds are risk-based decision limits rather than reference intervals; national surveys describe lipid distributions but were not designed to establish them. Analytical standardization through traceability programs, multicenter validation of formulas, and-where the distribution-based construct applies (HDLC, pediatrics)-nationally derived reference intervals are priorities for equitable cardiovascular risk assessment in Brazil.

Humans

Measurable Residual Disease and the Unresolved Biology of Leukemic Stem Cells.

Measurable residual disease (MRD) testing has transformed the management of hematologic cancers by enabling detection of residual malignant cells after therapy. Current approaches rely on qPCR and next-generation sequencing to monitor leukemia-associated somatic mutations, while multiparameter flow cytometry identifies aberrant leukemic immunophenotypes. Although these methods provide valuable prognostic and therapeutic information, MRD negativity remains an imperfect surrogate for cure. Most MRD platforms evaluate CD45+, rapidly dividing leukemic populations and fail to detect quiescent cells that may survive cytotoxic therapies which efficiently target proliferating hematopoietic cells. Relapse frequently occurs despite deep molecular remission, suggesting persistence of rare leukemic stem cells (LSCs) that are intrinsically resistant to chemotherapy and targeted therapies. The paradox of relapse despite molecular remission could be explained by the presence of very small embryonic-like stem cells (VSELs) which are pluripotent, quiescent stem cells sitting at the top of cellular hierarchy in multiple adult tissues including bone marrow. A pluripotent VSEL divides through asymmetrical cell division to give rise to two cells of different sizes and fates, smaller cell is to self-renew while the bigger is lineage-restricted and tissue-committed progenitor which undergoes extensive epigenetic changes, divides rapidly and undergoes clonal expansion before further differentiation. Dysfunctions of VSELs initiate both solid and hematologic cancers. Based on this view, somatic mutations monitored during MRD assessment possibly represent downstream consequences of clonal expansion rather than the initiating drivers of disease persistence. Thus, exclusive monitoring of somatic mutations and CD45&#x2009;+&#x2009;leukemic populations possibly overlook rare, small-sized, CD45- VSELs that contribute to therapeutic resistance and relapse.

Humans

Measuring economic efficiency in adult intensive care units: A systematic review of methods, metrics, and evidence.

OBJECTIVES: Intensive care units (ICUs) consume substantial hospital resources, yet "efficiency" is inconsistently defined and measured. This study systematically reviewed how economic efficiency has been conceptualised and quantified in adult ICUs and appraised the quality of evidence. METHODS: Following PRISMA 2020 and a PROSPERO-registered protocol (CRD420251107866), we searched MEDLINE, Embase, CINAHL, Cochrane Library and Web of Science (2000-August 2025), plus global grey sources. Eligible studies explicitly defined efficiency and reported an efficiency metric/model linking ICU inputs (e.g., staff, beds/capacity, time, consumables, or costs) to outputs/outcomes (e.g., throughput/discharges, length of stay/resource use, risk-adjusted mortality). Dual independent screening and extraction were performed. Study quality was appraised using MMAT, and findings were synthesised narratively (SWiM), given heterogeneity. RESULTS: 39 studies (2001-2025) from 17 countries were included, all from high-income or upper-middle-income settings. Four methodological families were identified: (1) frontier modelling (predominantly DEA; occasional SFA/RFDH), (2) benchmarking indicators (risk-adjusted mortality and LOS/resource-use ratios; "efficiency matrix" quadrant classification), (3) cost-outcome evaluations, and (4) operational/process metrics. Across families, variation in decision-making units, input/output selection, and risk adjustment limited comparability; long-term and patient-reported outcomes were absent, and equity considerations were uncommon. CONCLUSIONS: ICU efficiency research is feasible but fragmented and often methodologically limited. Standardised definitions, validated risk adjustment, uncertainty quantification, and inclusion of patient-centred and equity-relevant outcomes are needed before efficiency metrics can reliably inform value-based decision making.

Intensive Care Units

What do we know about medical invalidation and related concepts? - A scoping review and thematic analysis about the definitions, measurements, causes, consequences and potential solutions for medical invalidation.

BACKGROUND: Medical invalidation, medical gaslighting, and related constructs have gained visibility in public discourse but remain inconsistently defined in scientific literature. Despite growing research-often focused on specific diseases- to date, no single review has comprehensively synthesized their definitions, causes, consequences, or methods of measurement. This scoping review addresses this gap by examining medical invalidation and related constructs. METHODS: Using a preregistered protocol, we systematically searched PubMed, CINAHL, Web of Science, Google Scholar, and ProQuest (dissertations) without year restrictions. Eligible sources included peer-reviewed empirical, theoretical, and conceptual work in English addressing invalidation, gaslighting, or closely related notions within healthcare. A total of 158 studies were identified through database searches and citation tracking. Data extraction followed a standardized schema, and findings were synthesized descriptively and through thematic analysis to clarify terminology, map determinants and outcomes, and identify existing measurement approaches. RESULTS: The results showed substantial inconsistency in how "invalidation," "not being taken seriously," and "gaslighting" were defined. Medical invalidation emerged as a multifactorial phenomenon driven by diagnostic challenges, structural and societal factors, provider and patient characteristics, stigma, misattribution, interactional dynamics, academic knowledge gaps, and disease-related complexity. Invalidation was associated with wide-ranging behavioural, emotional, cognitive, physical, relational, and systemic harms, while validation had consistently beneficial effects. Proposed solutions in the summarized studies included communication improvements, clinician training, patient support, targeted research, and structural and systemic changes. DISCUSSIONS: Medical invalidation represents a complex, systemic issue with significant implications for patient safety. The discussion highlights its multifactorial origins, its potential to cause both psychological and physical harm, and the need for clearer conceptualisation within the field. Advancing research requires validated instruments and longitudinal designs to examine underlying mechanisms and consequences. Addressing medical invalidation will demand multi-level interventions to improve communication, reduce structural barriers, and promote equitable, patient-centred care. OSF PREREGISTRATION: https://doi.org/10.17605/OSF.IO/MPE6U.

Humans

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans