Search PubMedSearch

SEARCH · Search PubMed

Results for “Lung Volume Measurements”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

761 records · Page 10Linked to original sources

Intravenous lidocaine reduces the propofol EC50 for loss of consciousness and intraoperative anesthetic consumption in gynecological laparoscopy: A randomized controlled trial.

BACKGROUND: Intravenous lidocaine reduces propofol requirements and procedure-related adverse events. OBJECTIVES: The study aimed to test whether intravenous lidocaine would reduce the effect-site concentration of propofol required to achieve loss of consciousness and decrease propofol consumption during total intravenous anesthesia in gynecological laparoscopy. METHODS: This was a prospective, randomized, double-blind, placebo-controlled trial. Sixty patients were randomly allocated to receive either intravenous lidocaine (1.5 mg·kg-¹ bolus) followed by continuous infusion or an equal volume of saline. Propofol was administered via target-controlled infusion starting at an effect-site concentration of 3.5 μg/mL. The concentration was then adjusted in steps of 0.5 μg/mLaccording to Dixon's up-and-down sequential method: decreased if loss of consciousness was achieved, or increased if not. Loss of consciousness was defined as loss of response to verbal commands. The median effective concentration (EC50) of propofol for inducing loss of consciousness was calculated using the Dixon's up-and-down method. General anesthesia was maintained with propofol and remifentanil, guided by state entropy (target 40-60) and surgical pleth index (target 20-50). Drug consumption was normalized to anesthesia duration and body weight. RESULTS: The estimated EC50 of propofol for inducing loss of consciousness was significantly lower in the lidocaine group than in the saline group (3.32 μg/mL, 95% Confidence Interval (CI): 3.04-3.59 vs. 3.89 μg/mL, 95% CI: 3.50-4.28). Under the study protocol, the lidocaine group also required less propofol (8.62 mg·kg-1·h-1, 95% CI: 8.10-9.15 vs. 9.89 mg·kg-1·h-1, 95% CI: 9.05-10.73) and less remifentanil (0.23 μg·kg-1·min-1, 95% CI: 0.21-0.24 vs. 0.27 μg·kg-1·min-1, 95% CI: 0.24-0.30) compared with the saline group. CONCLUSION: Intravenous lidocaine reduced the propofol EC50 for Loss of Consciousness (LOC) and decreased intraoperative propofol and remifentanil consumptions in patients undergoing gynecological laparoscopy. These findings suggest a propofol- and opioid-sparing effect of intravenous lidocaine in this setting, although confirmation in larger multicenter trials is needed.

Humans

Characteristics of post-exercise responders versus non-responders following aerobic or isometric exercise in physically inactive adults of African and South Asian descent with high-normal blood pressure or grade I hypertension.

OBJECTIVE: To investigate interindividual variability in post-exercise hypotension (PEH) and to characterise cardiovascular and autonomic differences between responders and non-responders following aerobic and isometric exercise in adults of African and South Asian descent with elevated blood pressure (BP). METHODS: Physically inactive adults of African and South Asian descent living in Suriname (18-65 years) with high-normal BP or grade I hypertension participated in a randomised controlled crossover trial. In this randomised cross-over trial, 47 adults (50.1 ± 10.8 years; 38% male) with high-normal blood pressure or grade I hypertension completed three conditions: aerobic exercise (30 min at 40-60% heart rate reserve), isometric handgrip exercise, and a non-exercise control. Ambulatory BP was assessed over 24 h. PEH was defined as the net effect: (post-exercise - pre-exercise) - (post-control - pre-control). Participants were classified as responders if daytime BP decreased ≥5 mmHg. Arterial stiffness, cardiac, and autonomic parameters were assessed. RESULTS: Following aerobic exercise, 46% of participants were classified as systolic responders compared with 28% after isometric exercise. No baseline differences were observed in demographic or clinical characteristics between responders and non-responders, suggesting that PEH variability may reflect underlying physiological rather than clinical differences. Aerobic responders demonstrated greater reductions in aortic augmentation index (-19.4% vs. -10.9%, p = 0.05), larger increases in stroke volume (+8.1 vs. -5.3 mL, p = 0.05) and cardiac output (+1.54 ± 1.89 vs. +0.58 ± 1.60 L/min, p = 0.009), and more favourable autonomic recovery. Among all variables, only the change in cardiac output was associated with PEH magnitude (r = -0.46, p = 0.006). No consistent physiological differences were observed following isometric exercise. CONCLUSION: PEH following aerobic exercise is characterised by a distinct responder phenotype associated with greater reductions in aortic augmentation index and favourable cardiac adaptations. These findings highlight substantial interindividual variability in BP responses and support the need for individualised exercise strategies in hypertension management.

Adolescent

[Study of a patient with azoospermia due to variant of MOV10L1 gene].

OBJECTIVE: To explore the clinical and genotypic characteristics of a patient with Sertoli cell-only syndrome (SCOS) due to variants of MOV10L1 gene. METHODS: A 27-year-old patient with Non-obstructive azoospermia (NOA) underwent routine semen analysis. Serum levels of follicle-stimulating hormone (FSH), luteinizing hormone (LH), progesterone (P), estradiol (E2), prolactin (PRL), and testosterone (T) were determined by chemiluminescence assays. Peripheral blood samples were collected for G-banded karyotyping analysis. Multiplex PCR fluorescence detection was used to screen for AZF gene microdeletions. Whole exome sequencing (WES) and Sanger sequencing were performed simultaneously. Testicular biopsy tissues were subjected to Hematoxylin-Eosin (HE) staining to assess seminiferous tubule cell composition, and MOV10L1 protein expression was detected by immunohistochemical staining. Bioinformatics tools were employed to predict the pathogenicity of variants and their impact on protein structure and function. This study was approved by the Medical Ethics Committee of the Guangdong Institute of Reproductive Sciences [Ethics No.: 2023(01)]. RESULTS: The patient's two semen analyses had failed to detect any sperm. Hormone tests indicated elevated FSH (22.32 mIU/mL) and PRL (397.6 mIU/mL), while T (3.68 nmol/L) and E2 (38.32 pmol/L) were reduced. Chromosomal karyotyping revealed 46,XY, and no AZF gene deletion was detected. WES and Sanger sequencing detected compound heterozygous variants of the MOV10L1 gene, including a c.345C>A (p.C115X) nonsense variant and a c.3323C>T (p.T1108I) missense variant, with the former being unreported previously. HE staining showed only Sertoli cells in the seminiferous tubules, confirming the diagnosis of SCOS. Immunohistochemical staining revealed absent MOV10L1 protein expression in the testicular tissue. Based on the guidelines from American College of Medical Genetics and Genomics (ACMG), the c.345C>A (p.C115X) was classified as a pathogenic variant (PVS1+PM2_Supporting+PP4), while the c.3323C>T (p.T1108I) was deemed variant of uncertain significance (PM2_Supporting+PP3_Supporting+PP4). Bioinformatics analysis demonstrated that c.345C>A (p.C115X) may cause premature termination of protein translation, while c.3323C>T (p.T1108I) may disrupt the hydrophobicity of the RNA helicase domain, reducing the active pocket volume and decreasing its affinity for MILI protein. CONCLUSION: This study has diagnosed a case of SCOS due to compound heterozygous variants of the MOV10L1 gene, which also enriched its mutational spectrum.

Humans

Artificial Intelligence Cannot Replace Peer Reviewers but May Help Editors Triage: A Comparative Analysis of a Large Language Model and Human Reviewer Recommendations at the American Journal of Sports Medicine.

BACKGROUND: The peer review system faces increasing strain from rising manuscript volumes, reviewer fatigue, and well-documented interreviewer disagreement. Large language models (LLMs) have shown potential to support the peer review process, but their ability to replicate editorial decisions at high-impact medical journals and their utility as manuscript screening tools remain unknown. PURPOSE: To compare the agreement between an LLM and the final editorial decision on manuscripts submitted to the American Journal of Sports Medicine and to evaluate the potential of LLMs as a manuscript screening tool. STUDY DESIGN: Cross-sectional agreement study. METHODS: Fifty-four manuscripts randomly selected from submissions to the American Journal of Sports Medicine (September 2024-October 2024) were reviewed by a locally deployed LLM (Ministral 3 14B; Mistral AI) using a standardized prompt. The artificial intelligence (AI) produced a categorical recommendation (reject, cascade, revision, or accept) and a numerical score (0-100) for each manuscript. Agreement with the final editorial decision was assessed by Cohen kappa (4-category model) for pooled human reviewers (n = 139 reviews) and the AI (n = 54). Screening performance was evaluated by positive predictive value (PPV), sensitivity, and specificity. RESULTS: Pooled human reviewers demonstrated fair agreement with the final decision (&#x3ba; = 0.181 [P < .001]; 42.4% agreement), while the AI demonstrated slight, nonsignificant agreement (&#x3ba; = 0.126 [P = .099]; 37.0% agreement). The AI recommended revision for 61.1% of manuscripts, of which 72.7% were ultimately rejected or cascaded, demonstrating systematic "revision bias." When the AI recommended rejection, 54.5% of those manuscripts were ultimately rejected and 27.3% were cascaded; when the AI recommended cascade, 50% were rejected and 50% were cascaded. However, when the AI recommended rejection or cascade (n = 21), 90.5% received a final decision of rejection or cascade (PPV, 90.5%; specificity, 81.8%). Manuscripts with an AI score <70 were rejected or cascaded 88.0% of the time (PPV, 88.0%). CONCLUSION: AI cannot replicate the nuanced judgment of human peer reviewers at a high-impact sports medicine journal. When AI recommended rejection or cascade, 90.5% of manuscripts received that final decision (descriptive PPV, 90.5%; 95% CI, 71.1%-97.3%), suggesting potential utility as an exploratory first-pass screening tool warranting further validation in larger cohorts. However, AI could not reliably distinguish manuscripts destined for outright rejection from those that would be cascaded to a sister journal-an important limitation for editorial triage applications.

Sports Medicine

Aquablation/AquaBeam Waterjet Therapy for Benign Prostatic Hyperplasia: Three-Year Functional and Ejaculatory Outcomes in a Multicenter Real-World Italian Cohort.

OBJECTIVE: To evaluate the 3-year functional outcomes of Aquablation/AquaBeam waterjet therapy for bladder outlet obstruction secondary to benign prostatic hyperplasia (BPH), with particular attention to urinary symptoms, quality of life, continence, ejaculatory function, and complications. METHODS: We performed a retrospective analysis of a prospectively maintained multicenter database including 218 consecutive men who underwent Aquablation/AquaBeam for symptomatic BPH between January 2019 and January 2022 at three referral centers. Functional outcomes assessed preoperatively and during follow-up included International Prostate Symptom Score (IPSS), IPSS quality-of-life item (IPSS-QoL), maximum urinary flow rate (Qmax), post-void residual urine (PVR), continence, and ejaculatory function. Median follow-up was 36&#x2009;months. Ejaculatory preservation was evaluated only in patients with preserved antegrade ejaculation at baseline. RESULTS: Median age was 61&#x2009;years (IQR 57-66), median prostate-specific antigen (PSA) was 2.52&#x2009;ng/mL (IQR 0.40-21.60), and median prostate volume was 55&#x2009;mL (IQR 40-73). Median operative time was 56&#x2009;min, while median catheterization time and length of hospital stay were both 48&#x2009;h. Functional improvements were evident from the 3-month follow-up and remained stable through 36&#x2009;months. At 36&#x2009;months, median IPSS improved to 5 and median Qmax to 18&#x2009;mL/s. Median PSA changed modestly from 2.52&#x2009;ng/mL at baseline to 2.75&#x2009;ng/mL at 36&#x2009;months. No cases of de novo urinary incontinence were observed throughout follow-up. Among patients with preserved antegrade ejaculation at baseline, 87% maintained antegrade ejaculation at 36&#x2009;months. Most postoperative complications were minor (Clavien-Dindo grade I-II, 20.2%). One grade III rectal injury occurred (0.5%). Median hemoglobin decreased from 15.2&#x2009;g/dL preoperatively to 14.0&#x2009;g/dL before hospital discharge, and two patients required blood transfusion. During the 36-month follow-up, no surgical retreatment was required, whereas 11 patients (5.0%) received temporary medical retreatment. CONCLUSION: In this multicenter real-world cohort, Aquablation/AquaBeam was safe and effective over 3&#x2009;years, providing durable improvement in lower urinary tract symptoms and quality of life while preserving continence and antegrade ejaculation in most patients. These findings support Aquablation/AquaBeam as a valuable minimally invasive surgical option for selected men with BPH, particularly those who prioritize preservation of ejaculatory function. Longer-term and comparative studies are warranted. TRIAL REGISTRATION: 48281.

Humans

Structured robotic colorectal training in a non-tertiary NHS hospital: a 502-case consecutive cohort implementation study.

Robotic-assisted colorectal surgery has expanded rapidly across NHS practice in the UK. Structured unit-wide training pathways are essential for safe technology adoption, yet published outcome data from non-tertiary hospitals remain limited. This study describes the implementation and feasibility of a unit-wide robotic colorectal program at a high-volume non-tertiary hospital, reporting outcomes across 502 consecutive resections performed by eight consultant surgeons and presenting these in the context of nationally published benchmarks. A retrospective cohort study of 502 consecutive robotic colorectal resections performed at York Teaching Hospital between May 2022 and December 2025. Eight consultant surgeons (A-H) participated in a structured four-phase training pathway incorporating simulation training, proctored cases, complexity-based case progression, and formal credentialing. Primary outcomes were 30-day mortality, unplanned return to theatre (RTT), and anastomotic leak (AL). Anastomotic leak was calculated using only patients who underwent anastomosis as the denominator. Procedure-stratified and individual surgeon outcomes with 95% confidence intervals were reported. Risk-adjusted cumulative sum (RA-CUSUM) analysis was performed to evaluate learning curves. Outcomes are presented descriptively alongside nationally published reference data; no formal statistical comparison against national benchmarks was performed. 502 robotic colorectal resections were performed. Mean patient age was 70.0 &#xb1; 11.3&#xa0;years; 58.4% were male. Median ASA grade was III. The indication was malignancy in 89.2% of cases. Length of stay was non-normally distributed and is therefore reported using median and interquartile range in the revised analysis. Key outcomes: - 30-day mortality: 1.0% (5/502; 95% CI 0.4-2.3%) - Unplanned return to theatre (RTT): 5.2% (26/502; 95% CI 3.6-7.5%) - Anastomotic leak (AL): 3.3% (15/450; 95% CI 2.0-5.5%; denominator = patients with anastomosis) - 30-day unplanned readmission: 5.0% (25/502; 95% CI 3.4-7.2%) - Conversion to open surgery: 3.6% (18/502; 95% CI 2.3-5.6%) - Lymph node yield &#x2265;12: 91.3% of cancer resections - R0 resection rate: 95.1% of cancer resections All primary outcomes fell within or below the published reference ranges used for descriptive context. RA-CUSUM trajectories were heterogeneous: no surgeon crossed the predefined upper control limit, but several curves showed later upward movement. Accordingly, the analysis is interpreted as safety surveillance rather than evidence of uniform performance improvement. RA-CUSUM monitoring showed that no surgeon crossed the predefined upper control limit; however, heterogeneous trajectories precluded a claim of uniform performance improvement.

Humans

Instruments for measuring body image in breast cancer patients: a systematic review of measurement properties.

PURPOSE: To evaluate the psychometric properties of PROMs for measuring body image in breast cancer patients. METHODS: In December 2024, a psychometric systematic review was performed in the nine databases. The COSMIN checklist was employed to evaluate the methodological quality and psychometric properties of the included body image measures. The&#xa0;level of evidence was assessed using the GRADE framework, and final recommendations were formulated for the scale. RESULTS: Thirty-eight articles evaluating fifteen PROMs were included in this review. Structural validity, internal consistency, and hypothesis testing had been most frequently evaluated. Measurement error had not been assessed for all PROMs. Twelve instruments show potential application value but require further research. The BAS-BC, PSPP, and ASI-R are not recommended for use, as these instruments do not meet the strict COSMIN thresholds for full recommendation. CONCLUSION: The BIS can be recommended as a temporary screening tool for assessing body image outcome in clinical practice. The BIRS can be tentatively advised for measuring specific postoperative body image changes. However, further comprehensive studies are required to validate the psychometric properties of existing PROMs.

Female

Patient-reported outcomes in pediatric regional anesthesia trials: current use and limitations.

PURPOSE OF REVIEW: This review examines the current use and limitations of patient-reported outcome measures (PROMs) in pediatric regional anesthesia research. Despite the increasing emphasis on patient-centered outcomes, existing pediatric outcome assessment frameworks may inadequately capture the pain experience and interference with daily living. RECENT FINDINGS: Across 17 identified randomized controlled trials and 15 ongoing studies, PROM use remains highly variable, with consistent reliance on observational pain scales such as the Face, Legs, Activity, Cry, and Consolability scale and limited incorporation of standardized, longitudinal health-related quality-of-life measures. SUMMARY: Current pediatric PROM frameworks remain fragmented, limiting comprehensive evaluation of recovery. Greater standardization and incorporation of developmentally appropriate, longitudinal outcome measures are needed to better align clinical research with meaningful patient-centered endpoints and to improve assessment of functional and psychosocial recovery.

Humans

Patient-reported outcome measures for depression or anxiety symptoms in patients with cardiovascular disease: A COSMIN systematic review.

BACKGROUND: Depression and anxiety are common in patients with cardiovascular disease (CVD), but the measurement quality of patient-reported outcome measures (PROMs) used in this population remains unclear. This review aimed to evaluate the methodological quality, measurement properties, and certainty of evidence for depression and anxiety PROMs in adults with CVD and to inform instrument selection. METHODS: Following COSMIN and PRISMA guidance, four databases were searched from inception to February 2026. Studies assessing measurement properties of PROMs in adults with CVD were included. Methodological quality was evaluated using the COSMIN Risk of Bias checklist, and certainty of evidence was graded using an adapted GRADE approach. RESULTS: Sixty-six studies assessing 38 PROMs were included, comprising 29 generic and 9 CVD-specific instruments. Six PROMs met COSMIN Category A criteria: Cardiac Depression Scale-Short Form, Patient Health Questionnaire-9, Beck Depression Inventory-II, Hospital Anxiety and Depression Scale, Generalized Anxiety Disorder-7, and Major Depression Inventory. Four instruments were classified as Category C because of insufficient structural validity. Content-validity evidence was largely indeterminate or of limited certainty. Only 24 studies used confirmatory factor analysis or Rasch analysis, and no study assessed measurement error or responsiveness. Cross-cultural validity evidence was scarce. CONCLUSIONS: Six PROMs met Category A criteria, but selection should remain purpose- and context-specific. Particular attention should be given to somatic symptom overlap and intended clinical use. Further validation should prioritize content validity, measurement invariance, responsiveness, measurement error, and clinimetric performance.

Humans

Timing of OMERACT core domain measurement in gout clinical trials: a systematic review of randomised trials.

AIMS: The Outcome Measures in Rheumatology (OMERACT) initiative has endorsed core domain sets for gout trials. The aims of this study were to evaluate the time points and frequencies at which the gout core domains are measured in existing gout urate-lowering therapy and gout flare trials, and whether all collected measurements were reported. METHODS: Urate-lowering therapy (n = 29) and gout flare randomised clinical trials (n = 14) from 2005 were identified from a prior systematic review of core domain reporting. Data were extracted for the time points and frequencies at which each core domain was measured, as well as whether all collected measurements were reported. RESULTS: In urate-lowering therapy trials, the core domains were measured at seven different frequencies. Serum urate and gout flares were most commonly measured monthly, and tophus burden was most commonly measured three monthly. Reporting of all collected measurements varied, from 24/29 (83%) trials for serum urate to 0/2 (0%) trials for activity limitation. In gout flare trials, core domains were measured at nine different frequencies. Pain, joint tenderness and joint swelling were most commonly measured monthly. Reporting of all collected measurements varied, from 13/14 (93%) trials for pain to 3/8 (37.5%) trials for joint tenderness. CONCLUSION: In both urate-lowering therapy and gout flare trials, there is substantial variability in when the core domains are measured, and reporting of collected measurements is inconsistent. This work provides the foundation for a consensus process to establish standardised time points and frequencies for measuring the OMERACT-endorsed gout core domains.

Gout

An Assessment of Reliability Estimation Methods for Binomial Health Care Quality Measures.

We evaluated the performance of commonly used methods for estimating the reliability of binomial health care quality measures using simulated datasets spanning a range of performance score means and variances, numbers of entities, and patient sample sizes. For each simulation, reliability was estimated for all selected methods and compared with the known true reliability derived from the simulation parameters, with methods assessed on their accuracy and precision. Logistic regression with reliability estimated on the outcome scale demonstrated the highest accuracy and precision among all methods evaluated. The widely used Adams beta-binomial method performed poorly, although a modification recommended by Nieser and Harris substantially improved its performance. These approaches are applicable only to binomial measures. Among methods that can be applied to both binomial and continuous measures, permutation resampling of the Spearman rank correlation coefficient was the most accurate and precise, outperforming other commonly used approaches. Overall, for binomial quality measures, logistic regression on the outcome scale is the preferred method for reliability estimation, followed closely by the modified beta-binomial approach, while for non-binomial measures, permutation-based Spearman rank correlation appears to be the most suitable method.

Reproducibility of Results

Sensor-based measures of knee brace adherence have low agreement with self-report methods: A multi-measure study among knee osteoarthritis patients.

OBJECTIVE: To explore agreement between self-report and objectively measured adherence to brace wearing by patients with knee osteoarthritis. METHOD: A single-arm observational analysis nested within the PROP OA randomised controlled trial (ISRCTN28555470). Of 237 adults with symptomatic knee osteoarthritis randomised to brace treatment, 60 were included in this sub-study investigating three different methods of assessing knee brace wear time over 26 weeks: 1. Self-report questionnaires (SRQ) at 12 weeks and 26 weeks; 2. Short message service (SMS) questions (days worn in past week, typical hours per day when worn) administered from week 1 to week 24; 3. A skin temperature sensor embedded in the brace, sampling every 10&#x202f;min for 26 weeks. The presence and reason for the sensor were concealed from participants. The estimated proportion of participants meeting "minimum brace use", defined a priori as &#x2265;1&#x202f;h on &#x2265;2 days in past week, was described for each measurement method, overall and by brace type (unloader, neutral). For temperature sensor measurements, time spent above 24&#xb0;C and time spent above 25&#xb0;C were used. Agreement between the measures was summarised by percentage agreement and kappa (&#x138;). RESULTS: The estimated proportions of participants meeting "minimum brace use" at 12 weeks were 83% (SRQ), 83% (SMS), 60% and 58% (temperature sensor, 24&#xb0;C and 25&#xb0;C thresholds, respectively). At 26 weeks, the corresponding estimates reduced to 72%, 71% (SMS at 24 weeks), 43% and 37%. Sensor data suggested the sharpest decline in brace use occurred within the first 12 weeks. Agreement between self-report measures was higher than between self-report measures and sensor (SRQ vs SMS at 12 weeks: 92% agreement, &#x138;=0.67 (95%CI: 0.34, 1.00); SRQ vs Sensor at 12 weeks: 74%, 0.35 (0.10, 0.60); SMS vs Sens at 12 weeks: 76%, 0.36 (0.05, 0.66). Agreement between all measurement methods reduced at 26 weeks. CONCLUSIONS: This novel use of a temperature sensor to monitor brace adherence in knee osteoarthritis indicates that self-report adherence substantially overestimates knee brace wearing time, with implications for clinical trials and practice.

Humans

Longitudinal Repeated Protein Measurements in a Multiethnic Cohort Identify Novel Diabetes Biomarkers That Reveal Unique Disease Pathways.

There is up to a fourfold increase in diabetes biomarkers identified with longitudinal repeated versus single time point proteomic measurements. The increase in biomarkers identified with longitudinal repeated measurements is supported by a similar proportion being nominated as causal for type 2 diabetes with Mendelian randomization. Proteins unique to the longitudinal repeated analyses highlighted biological pathways (e.g., posttranslational protein modification and cellular structure and cycle regulation) that were distinct from pathways enriched among the shared proteins (e.g., small-molecule metabolic and catabolic processes). Longitudinal protein measurements identify additional novel disease biomarkers and disparate biological pathways compared with single measurement analyses.

Journal Article

Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically &#x2264;0.03 s; spatial parameters generally &#x2264;0.03 m). For joint kinematics during overground walking, median SEMs were 2.4&#xb0; (sagittal), 1.9&#xb0; (frontal), and 3.3&#xb0; (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Humans

Endoscopic Ultrasound-Guided Versus Transjugular Portal Pressure Measurements: Systematic Review and Meta-Analysis.

PURPOSE: Published reviews of endoscopic ultrasound-guided portal pressure gradient (EUS-PPG) have emphasized feasibility and safety. We performed a systematic review and meta-analysis specifically to evaluate how closely EUS-based portal pressure measurements track invasive comparator measurements in prospective paired studies and to summarize agreement, technical success, and adverse events. METHODS: We searched major databases through January 2026 for prospective cohorts reporting same-patient EUS-based portal pressure measurement and invasive hemodynamic measurements. Correlations were pooled with random-effects models and analyzed separately for studies comparing EUS-PPG with hepatic venous pressure gradient (HVPG) and studies comparing EUS-based portal measurements with direct portal venous pressure. Agreement and threshold discordance were summarized descriptively. RESULTS: Six prospective cohorts (127 attempted procedures) were included. In studies using HVPG as the comparator, the pooled correlation was 0.82 (95% CI, 0.72-0.89; I2&#x2009;=&#x2009;0%). In studies comparing EUS-based portal measurements with direct portal venous pressure, the pooled correlation was 0.86 (95% CI, 0.72-0.93; I2&#x2009;=&#x2009;16.9%). Technical success was 95.3%. EUS-PPG-attributed adverse events occurred in 2.4% of procedures, with no procedure-related deaths. Agreement data were limited. Reported limits of agreement were wide (approximately -&#xa0;6 to&#x2009;+&#x2009;7&#xa0;mmHg), and discrepancies of 5&#xa0;mmHg or greater occurred in 4 of 30 paired measurements. CONCLUSIONS: EUS-based portal pressure measurement is feasible and shows a strong association with invasive hemodynamic comparators, but the evidence base remains small (six cohorts, 127 attempted procedures). Further study will be necessary to establish patient-level agreement, procedural reproducibility, EUS-specific clinically significant portal hypertension thresholds, and whether HVPG-based decision thresholds can be transferred to EUS-derived measurements.

Humans

Genome-wide association study of estimated glomerular filtration rate using repeated measurements in the Taiwan Biobank.

BACKGROUND: Chronic kidney disease (CKD) is a major global public health issue, with genetic factors playing a significant role in kidney function. Although genome-wide association studies (GWAS) have identified numerous loci associated with estimated glomerular filtration rate (eGFR), most studies relied on a single time-point measurement, which limits the capacity to account for within-individual measurement variability. METHODS: We performed a repeated-measurement GWAS in the prospective Taiwan Biobank (Taiwanese ancestry; n = 25,004) using two repeated creatinine-based eGFR measurements. Repeated eGFR values were analyzed using a linear mixed-effects model with a subject-specific random intercept and time-varying covariates, providing a more precise estimate of eGFR level. Identified loci underwent functional annotation (expression quantitative trait locus, deleteriousness prediction, and epigenetic markers) and were compared with results from a single-measurement GWAS. RESULTS: Six loci associated with eGFR were identified, including four previously reported regions (1q22, 4q21.1, 11p14.1, and 17q21.2) and two additional loci (6p21.32 and 15q24.2). Functional annotation implicated several candidate genes-such as MUC1/EFNA1, SHROOM3, HLA-DQB1, MPPED2, NRG4, and PGAP3/FBXL20-in the regulation of kidney function. CONCLUSION: Incorporating repeated eGFR measurements into GWAS may improve phenotypic precision for identifying genetic associations with kidney function. This study identified eGFR-associated loci and biologically plausible candidate genes in a Taiwanese population, which require further replication and functional validation.

Chronic kidney disease