Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper↗

Ageing effects on chemical, physical, mechanical, and morphological properties of clear aligners - a systematic review.

BACKGROUND: Clear aligner (CA) therapy has experienced rapid use over the past two decades to treat orthodontic malocclusions. However, evidence on CA material degradation in the oral environment remains limited and often focuses on single brands or isolated material properties. OBJECTIVES: To investigate CA ageing characteristics across different materials and brands and evaluate the chemical, physical, mechanical, and morphological changes following simulated or intraoral ageing. SEARCH METHODS: Five databases (PubMed, Web of Science, MEDLINE [Ovid], ProQuest, and Scopus) were searched to 18 March 2026, with no restrictions. ELIGIBILITY CRITERIA: Studies assessing CA properties after intraoral use or simulated ageing (thermocycling, cyclic loading, or liquid immersion) were included. DATA COLLECTION AND ANALYSIS: Study selection followed PRISMA 2020. RoB was assessed using QUIN for purely in vitro studies, JBI for cohort in vivo studies, and Cochrane RoB 2 for RCTs. Results were synthesised narratively and organised by property domain, as substantial methodological heterogeneity precluded formal meta-analysis. Where protocols were comparable, a simple pooled weighted mean was calculated and presented graphically. RESULTS: Ninety-five studies were included. RoB was low in eight studies, moderate in sixty-two, and high in twenty-five. Chemical composition remained largely stable during ageing, though some brands showed trace elemental release. Physical, mechanical, and morphological properties showed material-dependent deterioration. Pooled discolouration was greatest with coffee (weighted mean ΔE = 70.9), versus tea (ΔE = 18.4) and red wine (ΔE = 11.5), with Invisalign® consistently exceeding the clinically perceptible threshold. Force decay of 40-90% typically occurred within 48 h. Thermoplastic polyurethane (TPU)-based and directly printed aligners (DPAs) generally showed greater susceptibility than polyethylene terephthalate glycol-modified (PETG)-based aligners, though findings on hardness, roughness, and stiffness were inconsistent. CONCLUSIONS: CA materials undergo clinically relevant degradation during use, particularly in TPU-based and DPAs aligners. Clinicians may need to prioritise material-specific protocols, reinforce dietary and cleaning instructions, and consider force decay when determining aligner replacement intervals. PROSPERO number: CRD420251110248.

Humans↗

Clinical performance of a giomer-based pit and fissure sealant with and without air-abrasion pretreatment: a 12-month randomized clinical trial.

BACKGROUND: Pit and fissure sealants are widely used for caries prevention; however, their long-term success depends largely on retention. Giomer-based sealants containing surface pre-reacted glass ionomer fillers offer bioactive properties, yet concerns remain regarding their bonding durability when applied with mild self-etch primers. This randomized clinical trial evaluated the effect of bioactive glass air-abrasion pretreatment on the retention and caries preventive efficacy of a giomer-based sealant in young adults over 12 months. METHODS: This parallel-arm randomized clinical trial included 96 participants, each contributing one eligible sound permanent molar (n&#x2009;=&#x2009;48 per group). Participants were randomly allocated to either bioactive glass air-abrasion pretreatment followed by application of a giomer-based sealant (intervention group) or application of the same sealant without pretreatment (comparator group). Sealant retention and secondary caries incidence were evaluated at baseline, 6 months, and 12 months using Simonsen's criteria, and modified United States Public Health Service (USPHS) criteria, respectively. The primary outcome was sealant retention at 12 months, whereas secondary caries incidence was assessed as a secondary outcome. Intergroup comparisons were analyzed using the Chi-square test. Intragroup comparisons were analyzed using Cochran's Q test followed by multiple comparisons. Relative risk with 95% confidence intervals was calculated. Statistical significance was set at p&#x2009;&#x2264;&#x2009;0.05. RESULTS: At 6 months, complete sealant retention was observed in 91.7% of teeth in the intervention group and 75.0% in the comparator group, with no statistically significant difference between groups (p&#x2009;=&#x2009;0.068). At 12 months, complete sealant retention was significantly higher in the intervention group (87.5%) than in the comparator group (33.3%) (p&#x2009;<&#x2009;0.0001). Teeth in the intervention group exhibited an 81.25% lower risk of sealant retention failure compared with the comparator group (RR&#x2009;=&#x2009;0.1875; 95% CI: 0.0864-0.4069; p&#x2009;<&#x2009;0.0001). No differences in secondary caries incidence were detected between groups during the 12-month follow-up period (p&#x2009;=&#x2009;1.0000). CONCLUSIONS: Bioactive glass air-abrasion pretreatment significantly improved the retention of a giomer-based fissure sealant compared with sealant application without pretreatment. No differences in secondary caries incidence were detected between groups during the 12-month follow-up period. Incorporating mechanical surface conditioning prior to sealant placement may enhance sealant retention without compromising preventive efficacy. TRIAL REGISTRATION: https://clinicaltrials.gov/ , (NCT06003452), 15-08-2023.

Humans↗

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n&#x202f;=&#x202f;50) of articles showed low risk-of-bias, while 7.4% (n&#x202f;=&#x202f;4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones↗

Proteomic insights into the immunomodulatory effects of Ca/Sr co-doped sol-gel coatings for titanium implants.

Ionic functionalization of biomaterial coatings has emerged as a powerful strategy to regulate early host responses at the implant interface. However, how combined Ca/Sr incorporation governs the adsorbed proteome and downstream immune signaling remains poorly understood. This study analyses, employing in vitro tests and proteomics, the effect of adding Sr and Ca to Si-based coatings designed to bioactivate Ti implants. Hybrid Si-based coatings were synthesized by the sol-gel route with a fixed Ca content (0.5&#x202f;wt%) and increasing Sr contents (0.5, 1.0, 1.5&#x202f;wt%), and their physicochemical properties, ion release kinetics, and hydrolytic stability were characterized. The coatings remained highly crosslinked despite Ca/Sr incorporation, whereas the highest Sr content increased hydrolytic degradation to around 70% after 56 days. Proteomic analysis identified 183 adsorbed proteins, of which 56 were differentially adsorbed on Ca/Sr-coatings, mainly associated with immune and coagulation pathways. In vitro, RAW 264.7 showed increased gene expression of TNF-&#x3b1; and TGF-&#x3b2;; with an enhanced TNF-&#x3b1; secretion by the addition of Ca and Sr. In parallel, MC3T3-E1 indicated that Ca/Sr-coatings were not cytotoxic and did not impair cell proliferation. However, ALP activity was reduced in the co-doped groups, indicating that the immunomodulatory effects induced by Ca/Sr incorporation were not accompanied by enhanced early osteogenic differentiation. The Ca/Sr combination induced alterations in the adsorption of immune-related proteins, which correlated with the in vitro findings. The deeper insight into how Ca/Sr mixtures modulate protein adsorption on biomaterial surfaces may be key to understanding the immunomodulatory capacity of these bioactive cations.

Animals↗

Marginal fit and five-year outcomes of posterior monolithic zirconia restorations: A randomized paired and observational clinical study.

OBJECTIVES: The aim of this study was to evaluate the marginal fit and five-year clinical performance of posterior 5 mol% yttria-partially stabilized zirconia restorations. A randomized paired comparison with lithium disilicate crowns was performed for marginal fit. METHODS: A total of 65 posterior restorations were placed in 38 patients, including 32 zirconia crowns, 17 lithium disilicate crowns, and 16 zirconia partial coverage restorations. In the randomized paired comparison, 17 patients received one lithium disilicate crown and one zirconia crown. Additional zirconia crowns (n=15) and zirconia partial coverage restorations (n=16) were included in a prospective observational cohort. The primary outcome was marginal fit within the randomized cohort. Marginal and internal fit were assessed using the replica technique. Marginal and internal gap values were compared using the Wilcoxon signed-rank test; clinical outcomes were analyzed descriptively, and Kaplan-Meier estimates were calculated for survival and complication-free survival. Clinical performance was assessed using CDA criteria, periodontal parameters, complication recording, and patient-reported outcomes. Clinical examinations were performed at baseline and at 12, 24, 36, 48, and 60 months. RESULTS: Mean marginal gap values at the crown margin were 46 &#xb1;33 &#xb5;m for lithium disilicate crowns and 50 &#xb1;32 &#xb5;m for zirconia crowns (p>0.05). No restoration required replacement, resulting in 100% restoration survival after a median follow-up of 60 months (range: 57-64 months). Most complications were biological or functional, including endodontic, periodontal, occlusal, and proximal-contact-related events. One zirconia partial coverage restoration exhibited a small ceramic fracture managed by polishing. The Kaplan-Meier probability of complication-free survival was 76.4% for zirconia crowns, 66.7% for lithium disilicate crowns, and 87.5% for zirconia partial coverage restorations. CONCLUSIONS: In the randomized paired comparison, 5 mol% yttria-partially stabilized zirconia crowns showed marginal gap values similar to lithium disilicate crowns. All restorations remained in situ during the observation period. Lower complication-free survival was mainly related to biological and functional events and should be interpreted separately from restoration survival. CLINICAL SIGNIFICANCE: Clinical evidence for posterior 5 mol% yttria-partially stabilized zirconia restorations remains limited. This study provides mid-term clinical data on crowns and partial coverage restorations. In the randomized full-crown comparison, marginal fit was similar to that of lithium disilicate crowns, supporting the clinical consideration of monolithic zirconia restorations for posterior teeth.

Humans↗

Preparation and study of non-thrombotic and biostable sulfobetaine-modified small-diameter polyurethane vascular grafts.

A novel sulfobetaine-modified polysiloxane-polycarbonate polyurethane (ZSiPCU) was synthesized. In vitro characterizations revealed that polysiloxane surface enrichment endowed the material with excellent biostability. Importantly, sulfobetaine zwitterions formed a robust hydration layer, effectively suppressing protein adsorption and platelet adhesion to ensure outstanding hemocompatibility. Furthermore, the material supported the adhesion and proliferation of vascular endothelial cells, confirming its cytocompatibility, while its elastomeric matrix provided rapid mechanical self-sealing capabilities. Electrospun ZSiPCU grafts were evaluated in a 3-month rat abdominal aorta model, maintaining high patency rates and facilitating in situ luminal endothelialization and smooth muscle cell remodeling. Additionally, superior puncture resistance of the grafts was demonstrated by puncture tests, with complete hemostasis achieved within 2&#x202f;mins through mechanical self-sealing.

Polyurethanes↗

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans↗

Effectiveness of STK Spray&#xae; for semen stain localization on solid surfaces: A specificity and sensitivity study.

Semen identification is a crucial step in sexual assault cases. The aim of this study was to assess STK Spray&#xae;, a presumptive test for semen, under controlled conditions including, simulated crime scene stains detection. Easy to use, it can be sprayed directly onto different surfaces and visualized under UV light. Several tests were performed on five different substrates (ceramic tile, drywall, metal, wood, and faux leather). The spray was able to enhance semen fluorescence, especially in diluted samples, with characteristic "globular" spots. Although it showed good specificity, false positives could be obtained with 10% bleach. The fluorescence signals were quantified using ImageJ&#x2122; and showed a statistically significant substrate-dependent variability. Mixture analysis indicated that saliva did not interfere with detection of semen, while urine partially suppressed the signal and blood markedly affected its interpretation. Simulation tests with UV lamp comparisons confirmed the importance of choosing the right detection method and the utility of this presumptive test in combination with additional immunochromatographic tests. A preliminary signal retention test showed stable fluorescence for up to two years when stains were stored appropriately. Finally, complete DNA profiles (100% of alleles) were obtained from all samples (n&#xa0;=&#xa0;24) after exposure to the reagent and UV light. Because of its ability to enhance semen signal, especially on specific surfaces, and its rapidity of use and detection, STK Spray&#xae; may represent a useful aid in the preliminary screening phase.

Humans↗