Search PubMed⌕ Search

SEARCH · Search PubMed

Search Search PubMed

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

The Role of Artificial Intelligence Combined With Digital Cholangioscopy for Indeterminant and Malignant Biliary Strictures: A Systematic Review and Meta-analysis.

BACKGROUND: Current endoscopic retrograde cholangiopancreatography (ERCP) and cholangioscopic-based diagnostic sampling for indeterminant biliary strictures remain suboptimal. Artificial intelligence (AI)-based algorithms by means of computer vision in machine learning have been applied to cholangioscopy in an effort to improve diagnostic yield. The aim of this study was to perform a systematic review and meta-analysis to evaluate the diagnostic performance of AI-based diagnostic performance of AI-associated cholangioscopic diagnosis of indeterminant or malignant biliary strictures. METHODS: Individualized searches were developed in accordance with PRISMA and MOOSE guidelines, and meta-analysis according to Cochrane Diagnostic Test Accuracy working group methodology. A bivariate model was used to compute pooled sensitivity and specificity, likelihood ratio, diagnostic odds ratio, and summary receiver operating characteristics curve (SROC). RESULTS: Five studies (n=675 lesions; a total of 2,685,674 cholangioscopic images) were included. All but one study analyzed a deep learning AI-based system using a convoluted neural network (CNN) with an average image processing speed of 30 to 60 frames per second. The pooled sensitivity and specificity were 95% (95% CI: 85-98) and 88% (95% CI: 76-94), with a diagnostic accuracy (SROC) of 97% (95% CI: 95-98). Sensitivity analysis of CNN studies (4 studies, 538 patients) demonstrated a pooled sensitivity, specificity, and accuracy (SROC) of 95% (95% CI: 82-99), 88% (95% CI: 72-95), and 97% (95% CI: 95-98), respectively. CONCLUSIONS: Artificial intelligence-based machine learning of cholangioscopy images appears to be a promising modality for the diagnosis of indeterminant and malignant biliary strictures.

Humans↗

Diagnostic performance of machine learning models versus established risk stratification for intracranial aneurysm rupture: a systematic review and bivariate meta-analysis.

BACKGROUND: Machine learning (ML) models have been proposed to improve the discrimination of intracranial aneurysm rupture status beyond established clinical risk stratification tools. However, reported performance is heterogeneous and the relative contribution of model architecture and feature dominance remains unclear. METHODS: We performed a Preferred Reporting Items for Systematic Reviews and Meta-Analyses-diagnostic test accuracy systematic review and diagnostic meta-analysis of studies evaluating ML models for intracranial aneurysm rupture discrimination. PubMed, Embase and CENTRAL were searched to February 2026. Sensitivity and specificity were pooled using a bivariate random-effects model, with summary receiver operating characteristic curves generated across training, internal testing and external validation datasets. Models were compared with regression-based approaches and Population, Hypertension, Age, Size of aneurysm, Earlier subarachnoid haemorrhage, Site of aneurysm (PHASES) scores. Subgroup and meta-regression analyses explored associations between algorithm family and feature domain. RESULTS: Sixty-two retrospective cohorts (29 709 patients 209 models) met the inclusion criteria. In training datasets, pooled sensitivity and specificity for ML were 0.81 (95% CI 0.75 to 0.85) and 0.83 (0.80-0.86), with an area under the curve (AUC) of 0.878, exceeding PHASES (AUC 0.667). In testing datasets, ML retained higher discrimination (AUC 0.837) than regression models (0.806) and PHASES (0.646). In external validation, sensitivity was preserved (0.82), but specificity declined (0.66). Deep learning demonstrated the highest AUCs (training and testing). Incorporation of haemodynamic or radiomic features improved pooled discrimination relative to morphology alone. Evidence of small-study effects and mostly unclear Prediction Model Risk Of Bias Assessment Tool ratings were observed. CONCLUSIONS: ML approaches demonstrate higher pooled discrimination for aneurysm rupture status than conventional risk scores in retrospective datasets, but reduced external validation specificity and heterogeneity limit confidence for clinical translation. Prospective, externally validated, calibrated models are required before integration into routine cerebrovascular risk stratification.

Humans↗

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2×2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I²=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans↗

Repeated scoring with the adult appendicitis score improves the sensitivity and the specificity of appendicitis diagnosis in patients with early equivocal signs of appendicitis: a secondary analysis.

PURPOSE: The utilization of computed tomography in the early stage of acute appendicitis may result in overdiagnosis and unnecessarily expose patients to ionising radiation. The Adult Appendicitis Score (AAS) can be used to select patients for imaging. Observation and re-scoring in the DIAMOND trial reduced the need for imaging. Now, we wanted to determine if the change in AAS (∆AAS) can serve as a diagnostic tool to select patients for imaging even more precisely. METHODS: Eighty-eight patients with early equivocal appendicitis participated in the observation arm of the DIAMOND trial. The data for these patients were reanalysed, and ∆AAS during the observation was calculated. The baseline AAS, final AAS, and the change in C-reactive protein (∆CRP) were selected as reference standards. RESULTS: Eighty-three patients with complete data were included in the analysis. The AUROC (Area Under the Receiver Operating Characteristic) values are as follows: ∆AAS, 0.932 (95% CI 0.868-0.996); baseline AAS, 0.629 (95% CI 0.498-0.760); final AAS, 0.936 (95% CI 0.886-0.987); and ∆CRP, 0.796 (95% CI 0.696-0.897). Using receiver operating characteristic curves, we established the thresholds for low (AAS ≤ -2), intermediate (AAS -1 to 0), and high (AAS ≥ 1) probability of appendicitis. The negative predictive value for the low-probability group and the positive predictive value for the high-probability group concerning acute appendicitis were 97% and 94%, respectively. CONCLUSION: Patients with equivocal signs of appendicitis may benefit from short observation and the calculation of ∆AAS to reduce overdiagnosis and exposure to excessive imaging. REGISTRATION: The DIAMOND trial was officially registered on ClinicalTrials.gov (NCT02742402) on April 13, 2016.

Adult↗

Diagnostic and prognostic value of fibroblast growth factor 23 in acute kidney injury: systematic review and meta-analysis.

Background: Acute kidney injury (AKI) is associated with high mortality and adverse outcomes. Fibroblast growth factor 23 (FGF23) has emerged as a potential biomarker for AKI; however, its diagnostic and prognostic utility remains inconsistent.Methods: We conducted a systematic review and meta-analysis of studies evaluating circulating intact FGF23 (iFGF23) or C-terminal FGF23 (cFGF23) (PROSPERO: CRD42022302659). PubMed, EMBASE, CNKI, and Wanfang databases were searched through June 9, 2026. QUADAS-2 was used for quality assessment. A random-effects bivariate model pooled sensitivity, specificity, positive/negative likelihood ratio (PLR/NLR), diagnostic odds ratio (DOR), and area under the summary receiver operating characteristic curve (SROC AUC).Results: Twenty-three studies were included: 17 diagnostic, 6 prognostic (one addressing both). For AKI diagnosis, the pooled sensitivity was 0.79 (95% CI 0.73-0.86), specificity 0.82 (95% CI 0.75-0.89), PLR 4.40 (95% CI 2.59-6.21), NLR 0.25 (95% CI 0.16-0.34), DOR 17.49 (95% CI 8.67-35.16), and SROC AUC 0.87 (95% CI 0.81-0.92). Substantial heterogeneity was observed (I2 = 67%), with iFGF23 demonstrating higher accuracy than cFGF23 (AUC 0.91 vs 0.81). For AKI mortality, pooled sensitivity was 0.77 (95% CI 0.69-0.84), specificity 0.76 (95% CI 0.70-0.82), DOR 10.89 (95% CI 6.86-17.30), and SROC AUC 0.77 (95% CI 0.70-0.83). Significant heterogeneity was noted (I2 = 86.2% for sensitivity, 80.4% for specificity). No significant publication bias was detected.Conclusions: Circulating FGF23 exhibits moderate-to-high diagnostic and moderate prognostic performance in AKI, though interpretation is limited by substantial heterogeneity. It may serve as a complementary biomarker for risk stratification, pending further validation with standardized protocols.

Humans↗

Comprehensive assessment of vasospastic angina using coronary computed tomography angiography: synergistic value of the presence of myocardial bridge, perivascular inflammation, and myocardial extracellular volume fraction.

AIMS: Coronary computed tomography angiography (CCTA) has evolved beyond anatomical assessment to include sophisticated tissue characterization. While an elevated perivascular fat attenuation index around the right coronary artery (FAI-RCA) is known to reflect coronary inflammation in vasospastic angina (VSA), recurrent vasospasms may also induce chronic subclinical myocardial injury and subsequent remodelling, potentially associated with an increased myocardial extracellular volume fraction (ECV). However, the diagnostic integration of ECV and FAI-RCA for identifying VSA in patients with angina with non-obstructive coronary arteries (ANOCA) remains to be elucidated. METHODS AND RESULTS: This study included consecutive ANOCA patients who underwent CCTA with a dedicated ECV protocol, followed by an invasive spasm provocation test. Comprehensive CCTA analysis quantified both FAI-RCA and the transmural ECV gradient (the difference between endocardial and epicardial ECV: ECVEndo - ECVEpi). Of the 100 patients analysed (mean age: 65.3 &#xb1; 11.8 years; 55% male), 27 were diagnosed with VSA. Multivariable logistic regression analysis identified transmural ECV gradient [odds ratio (OR): 1.12, 95% confidence interval (CI): 1.01-1.25], presence of myocardial bridging (MB) (OR: 3.49, 95% CI: 1.25-9.74), and high FAI-RCA (> -70.95 Hounsfield units [HU]) (OR: 5.79, 95% CI: 2.06-16.30) as significant independent predictors of VSA (all P < 0.05). Notably, the integration of transmural ECV gradient provided incremental diagnostic value beyond FAI-RCA and MB, as assessed by the Net Reclassification Improvement and Integrated Discrimination Improvement. CONCLUSION: A multi-parametric CCTA approach potentially identifies patients at high risk for VSA. The significant association of the transmural ECV gradient with VSA suggests that myocardial remodelling imaging provides a novel diagnostic window into the cumulative myocardial impact of vasospasm, independent of active adipose tissue inflammation and the presence of MB.

Humans↗

HPV circulating tumor DNA as a potential prognostic and predictive biomarker in head and neck squamous cell carcinoma: a systematic review.

PURPOSE: Human papillomavirus circulating tumor DNA (HPVctDNA) has emerged as a promising prognostic biomarker in HPV-related head and neck squamous cell carcinoma (HNSCC). This systematic review aimed to synthesize current evidence on the diagnostic accuracy and prognostic value of HPVctDNA in HNSCC management. MATERIAL/METHODS: We systematically reviewed a PubMed-indexed database of studies published between January 2012 and September 2025. Eligible studies were assessed for design, primary tumor site and stage, treatment modality, HPVctDNA detection method, diagnostic accuracy (sensitivity and specificity), and reported clinical endpoints. Descriptive syntheses were performed; sensitivity and specificity were standardized to proportions and summarized as median values per group. RESULTS: A total of 60 studies, including 8,234 patients were analyzed, of which 41 (68.3%) focused exclusively on oropharyngeal squamous cell carcinoma (OPSCC) and 17 (28.3%) included mixed HPV-related HNSCC subsites and HPV-positive cancers of unknown primary. The median follow-up across the included studies was 23&#xa0;months. Among the included studies, 19 were retrospective (31.7%) and 33 were prospective (55.0%), with a small proportion of cross-sectional and randomized clinical trials. Overall, 40 (66.7%) evaluated the role of HPVctDNA in a curative setting. Plasma was the most common sample type, analyzed in 55 studies (91.7%), while 5 studies also included saliva. Detection methods varied: 40 employed droplet digital PCR (ddPCR), 16 used quantitative PCR (qPCR) and 4 applied NGS-based assays. Most of these studies (38, 63.3%) evaluated the prognostic utility of HPVctDNA, while only 4 (6.7%) assessed HPVctDNA in a screening or diagnostic setting. Regarding diagnostic accuracy, the median sensitivity across evaluable studies was 91.1%, while the median specificity was 99.4%. In OPSCC-only cohorts, the median sensitivity and specificity were 89.4% and 99.4%, respectively. Dynamic changes in HPVctDNA levels during or after treatment were consistently associated with outcomes: clearance or sustained negativity correlated with higher response rates, improved progression-free survival and overall survival, while persistent positivity or increasing levels predicted disease progression and recurrence. CONCLUSIONS: HPVctDNA demonstrates high diagnostic and prognostic accuracy in HPV-related HNSCC, especially OPSCC, supporting its use for prognosis, treatment monitoring and early detection of recurrence. However, prospective interventional studies are still required to demonstrate that HPVctDNA-guided treatment decisions improve clinical outcomes before routine implementation.

Humans↗

Diagnostic performance of panfungal PCR on tissue specimens for the diagnosis of invasive fungal diseases: a systematic review and meta-analysis of the Fungal PCR Initiative (FPCRI).

UNLABELLED: Invasive fungal diseases are difficult to diagnose because of the limited sensitivity of culture. Panfungal PCR amplicon sequencing assays (targeting ribosomal RNA, such as 18S, 28S, ITS) are recommended for fungal identification in histopathology samples showing fungal elements. However, data describing its overall performance and consistency are lacking. This systematic literature review and meta-analysis assessed the performance of panfungal PCR on formalin-fixed paraffin-embedded (FFPE) and non-fixed (fresh or frozen) tissue samples. A systematic literature search was performed to include studies reporting the use of panfungal PCR for fungal identification in FFPE or non-fixed tissue samples. PCR sensitivity and specificity were assessed using the reference standard of histopathology showing fungal elements. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled estimates were obtained using random-effects meta-analysis. Twenty-eight studies were included. In FFPE samples (18 studies, 852 samples), sensitivity and specificity were 75.4% (95% confidence interval [CI], 59.2-86.6) and 93.5% (70.2-98.9), respectively. Sensitivity in non-fixed samples (13 studies, 207 samples) was 86.5% (74.7-93.3), while specificity could not be assessed (insufficient data). Comparative analyses showed a significantly higher sensitivity of panfungal PCR over culture (88.2%; 76-94.7 vs 52.2%; 39-65, P = 0.001). Sub-analyses could not demonstrate the superiority of one PCR target over another due to limited data. Panfungal PCR exhibited adequate sensitivity and good specificity in FFPE samples. Sensitivity was even higher in non-fixed samples and largely superior to culture. Nevertheless, large interstudy variability was observed, warranting interlaboratory studies to define the optimal PCR target and standardized protocols. IMPORTANCE: Invasive fungal diseases are difficult to diagnose because of the low sensitivity of culture. Panfungal PCRs are widely used for fungal identification in tissue specimens but suffer from heterogeneous procedures and performance. This meta-analysis shows an acceptable sensitivity (75.4% and 86.5% in fixed and non-fixed samples, respectively) and good specificity (93.5%) of panfungal PCR, supporting its use, not only on histopathology-positive fixed samples but also in non-fixed samples concomitantly with other diagnostic tools (cultures and fungal-specific PCRs if available). These results provide a strong basis for further standardization of panfungal PCR techniques via interlaboratory assays to assess reproducibility and optimize analytical protocols. CLINICAL TRIALS: This study is registered with PROSPERO as CRD42023461148.

Humans↗

MIC-based tuberculosis drug susceptibility testing using Sensititre MYCOTB: a diagnostic accuracy meta-analysis.

Accurate drug susceptibility testing (DST) is crucial for designing effective regimens for multidrug-resistant (MDR) and pre-extensively drug-resistant tuberculosis (pre-XDR TB). Sensititre MYCOTB enables simultaneous determination of minimum inhibitory concentrations (MICs) for multiple drugs, but its diagnostic performance varies across studies. This meta-analysis evaluated the diagnostic performance of Sensititre MYCOTB for key MDR and pre-XDR TB drugs. The protocol was registered in PROSPERO (CRD420251230599). PubMed, Cochrane, Google Scholar, Scopus, ONOS, Web of Science, ScienceDirect, and registries were systematically searched for studies published between 2010 and 2025. Studies comparing the Sensititre MYCOTB with reference DST for Mycobacterium tuberculosis complex (MTBC) were included. Bias assessment and pooled diagnostic accuracy estimates were generated. Fourteen studies, including 1,728 isolates, were analyzed. Rifampicin and isoniazid demonstrated high sensitivity (0.976 [95% CI: 0.94-0.99] and 0.977 [95% CI: 0.95-0.99]) and specificity (0.958 [95% CI: 0.84-0.98] and 0.957 [95% CI: 0.83-0.99], respectively) with low heterogeneity. Amikacin, kanamycin, and ofloxacin demonstrate good diagnostic accuracy, with high specificity (>0.98 [95% CI]). Moderate diagnostic accuracy was observed for ethambutol, streptomycin, ethionamide, and rifabutin. Cycloserine, moxifloxacin, and para-aminosalicylic acid showed inconsistent performance despite excellent specificity (>0.97 [95% CI]). Sensitivity analysis partially improved pooled sensitivity for moxifloxacin 0.801 (95% CI: 0.585-0.924) and para-aminosalicylic acid 0.76 (95% CI: 0.518-0.894), whereas cycloserine remained at 0.436 (95% CI: 0.190-0.725), although heterogeneity persisted. Sensititre MYCOTB DST demonstrates high diagnostic accuracy for MDR-TB and pre-XDR-TB drugs, while caution is required with cycloserine, moxifloxacin, and para-aminosalicylic acid. These findings support the integration of MIC-based testing into clinical decision-making.

Microbial Sensitivity Tests↗

Diagnostic performance of machine learning models for malignant and non-malignant pleural effusion: Systematic review and meta-analysis.

BACKGROUND: Accurately distinguishing malignant pleural effusion (MPE) from non-malignant pleural effusion is clinically important, but the generalisability and methodological quality of machine-learning (ML) models remain uncertain. METHODS: We searched eight databases to 23 April 2026. Diagnostic performance was pooled using random-effects and Reitsma bivariate models, and study quality was assessed using PROBAST+AI. RESULTS: Forty-two studies were included; 17 contributed to the AUC meta-analysis and 14 to the bivariate analysis. The pooled AUC was 0.90 (95&#xa0;% CI 0.85-0.94; 95&#xa0;% prediction interval 0.62-0.98), with sensitivity of 0.80 (95&#xa0;% CI 0.77-0.83) and specificity of 0.87 (95&#xa0;% CI 0.79-0.92). Only nine studies reported external, temporal or independent validation. Externally validated studies had a lower pooled AUC than studies without external validation (0.83 vs 0.92), with lower specificity observed in the two externally validated studies contributing sensitivity and specificity data. All 42 development assessments had high overall quality concerns, and all 42 model evaluations were judged at high risk of bias. CONCLUSIONS: ML models showed good apparent accuracy for distinguishing MPE from non-MPE, but the evidence was limited by substantial heterogeneity, high risk of bias and scarce external validation. The pooled estimates reflect the average performance of different selected models rather than the expected accuracy of a single clinical test. ML models should be regarded as adjuncts to existing diagnostic pathways until they are confirmed by rigorous multicentre prospective external validation and clinical-impact studies.

Humans↗

Artificial intelligence-supported double reading in European population breast cancer screening: A systematic review and meta-analysis of prospective programs.

BACKGROUND: Most European population mammography screening programs rely on double reading with arbitration, a model that delivers mortality benefit but is increasingly challenged by radiologist workload, variable specificity, and interval cancers. Artificial intelligence (AI) is being evaluated to support or optimize these established European screening pathways. PURPOSE: To synthesize prospective or program-embedded evaluations of AI conducted within European-style population screening programs and to estimate exploratory program-level absolute risk differences (RDs) per 1000 examinations for cancer detection rate (CDR) and recall. MATERIALS AND METHODS: We performed a prespecified, focused evidence synthesis of three large studies embedded within routine population screening programs operating under European-relevant workflows: MASAI (randomized AI-supported risk triage within a national program), ScreenTrustCAD (prospective paired-reader evaluation with AI as an independent reader in a double-reading framework), and PRAIM (nationwide decision-referral implementation). Outcomes were harmonized as AI-control RDs per 1000 examinations. Random-effects pooling used Hartung-Knapp-Sidik-Jonkman models. For the paired-reader design, sensitivity analyses applied a Kish effective sample-size approach across plausible within-examination correlations (&#x3c1;&#xa0;=&#xa0;0.3-0.8). Positive predictive value (PPV) and workflow/time outcomes were summarized descriptively. RESULTS: Across 597,419 examinations, the pooled CDR RD was +0.9 per 1000 (95% CI -0.0 to +1.8; I2&#xa0;&#x2248;&#xa0;12%), consistent with a modest directional increase with borderline statistical uncertainty. The pooled recall RD was -0.6 per 1000 (95% CI -3.1 to +2.1; I2&#xa0;&#x2248;&#xa0;41-43%), indicating no consistent recall increase across screening programs. Where reported, PPV was higher with AI-supported screening. Efficiency signals included 44.3% fewer total readings in MASAI and shorter reading times for AI-normal examinations in PRAIM; in PRAIM, a program-level safety-net mechanism recovered 204 cancers that would otherwise have been missed. CONCLUSION: In European population screening programs characterized by double reading and arbitration, prospective program-embedded evidence suggests that AI integration may yield a small absolute increase in cancer detection (&#x2248;1/1000) without a consistent increase in recall, alongside improved PPV and efficiency signals. These findings suggestAI primarily as a complementary reader within European screening workflows, with implementation requiring explicit quality assurance and monitoring of interval cancers and stage distribution.

Humans↗

Ultra-high-frequency ECG quantifies residual electrical dyssynchrony during left bundle branch area pacing in patients with wide QRS: a paired within-patient study.

BACKGROUND: Left bundle branch area pacing (LBBAP) may restore a more physiological pattern of ventricular activation in patients with conduction delay; however, QRS narrowing alone may incompletely characterize electrical resynchronization. Ultra-high-frequency ECG (UHF-ECG) provides quantitative markers of ventricular activation timing and dyssynchrony. OBJECTIVE: To quantify paired OFF-to-ON changes in conventional ECG and UHF-ECG metrics during LBBAP in patients with baseline wide QRS and to assess the relationship between paced R-wave peak time (RWPT) and residual UHF-ECG dyssynchrony. METHODS: In this prospective single-center paired study, 21 patients with bradycardia and baseline wide QRS underwent standard ECG and UHF-ECG assessment during intrinsic rhythm (pacing OFF) and during LBBAP (pacing ON). Endpoints included QRS duration, signed VED16, absolute VED16 (|VED16|), mean ventricular delay (meanVD), and a clinically interpretable distance-to-normal metric defined as dist&#xa0;=&#xa0;max(|VED16|-20, 0). Paired changes were summarized as medians with bootstrap 95% confidence intervals and tested using the Wilcoxon signed-rank test. Associations between paced RWPT and residual dyssynchrony during pacing were evaluated using Pearson and Spearman correlation coefficients. RESULTS: LBBAP significantly narrowed QRS duration from 136.8 [130.2-153.6] ms during intrinsic rhythm to 116.0 [107.8-125.6] ms during pacing (median &#x394; -21.0&#xa0;ms; 95% CI -33.9 to -18.6; p&#xa0;<&#xa0;0.001). Signed VED16 did not change significantly (median &#x394; 0.4&#xa0;ms; p&#xa0;=&#xa0;1.000), consistent with the mixed conduction-phenotype composition of the cohort. In contrast, severity-oriented UHF-ECG endpoints improved: |VED16| decreased numerically (median &#x394; -5.2&#xa0;ms; p&#xa0;=&#xa0;0.070), whereas dist decreased significantly (median &#x394; -0.7&#xa0;ms; 95% CI -14.4 to 0.0; p&#xa0;=&#xa0;0.015). The proportion of patients within the normal dyssynchrony band (|VED16|&#xa0;&#x2264;&#xa0;20&#xa0;ms) increased from 7/21 (33.3%) to 12/21 (57.1%). Median paced RWPT was 66.6 [58.6-74.6] ms, and shorter RWPT correlated with lower residual |VED16| during pacing (Pearson r&#xa0;=&#xa0;-0.45, p&#xa0;=&#xa0;0.038). CONCLUSIONS: In patients with baseline wide QRS, LBBAP produces marked QRS narrowing, whereas UHF-ECG provides complementary quantification of residual electrical dyssynchrony. Severity-oriented UHF-ECG endpoints, particularly a distance-to-normal metric, may offer an interpretable mechanistic framework beyond conventional ECG alone. Shorter paced RWPT was associated with lower residual dyssynchrony during pacing, supporting physiological coherence between procedural and high-resolution electrocardiographic markers.

Humans↗

Diagnostic accuracy of bronchoalveolar lavage fluid-based testing for pulmonary cryptococcosis: A systematic review and meta-analysis.

BACKGROUND: Pulmonary cryptococcosis(PC) presents diagnostic challenges because of its non-specific clinical and radiological manifestations. Bronchoalveolar lavage fluid (BALF)-based testing, which includes latex agglutination (LA) and lateral flow assay (LFA), offers a minimally invasive diagnostic method, yet its pooled diagnostic accuracy remains unclear. METHODS: We systematically searched PubMed, Embase, Cochrane Library, and Scopus from inception to May 2026. Studies evaluating BALF-based testing for PC with extractable 2 &#xd7; 2 data were included. The methodological quality of relevant studies was assessed by the QUADAS-2 tool. Pooled sensitivity, specificity, likelihood ratios, and diagnostic odds ratio (DOR) were estimated using a bivariate random-effects model. Subgroup analyses were performed by testing method and reference standard type. Heterogeneity was evaluated through paired forest plots, HSROC visualization, and exploratory bivariate meta-regression. RESULTS: The pooled sensitivity was 0.87 (95% CI: 0.81-0.91), and the specificity was 0.99 (95% CI: 0.982 - 0.995). The pooled positive likelihood ratio (PLR) was 88.00 (95% CI: 47.39 - 163.42), the negative likelihood ratio (NLR) was 0.13 (95% CI: 0.09 -0.20), and the DOR was 658.50 (95% CI: 285.36-1519.55). No significant threshold effect or publication bias was detected. Exploratory meta-regression suggested a possible assay-method effect in the joint model (P = 0.03), mainly driven by specificity (P = 0.01). CONCLUSIONS: The study demonstrates the high accuracy of CrAg in BALF for the diagnosis of pulmonary cryptococcosis, supporting its role as an important adjunctive diagnostic tool, particularly when tissue biopsy is not feasible or rapid results are needed. Larger prospective studies with standardized protocols are needed to validate these estimates.

Humans↗

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2&#xa0;-&#xa0;V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12&#x2011;lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2&#xa0;-&#xa0;V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12&#x2011;lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000&#xa0;Hz. In the standard recording, the digital PBL was calculated as V2&#xa0;-&#xa0;V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008&#xa0;mV). CONCLUSIONS: Physical acquisition of the V2&#xa0;-&#xa0;V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans↗

Diagnostic accuracy of nuclear STAT6 immunohistochemistry for solitary fibrous tumour: a systematic review and meta-analysis.

Nuclear STAT6 immunohistochemistry is the diagnostic surrogate for the NAB2::STAT6 fusion of solitary fibrous tumour (SFT); its sensitivity is established, but specificity varies for unexamined reasons. This review quantified pooled accuracy and tested whether antibody clone and nuclear threshold govern specificity. PubMed, Scopus and Web of Science were searched to 29 June 2026 for studies reporting nuclear STAT6 immunohistochemistry against a reference standard (NAB2::STAT6 confirmation and/or expert consensus) in SFT and comparators, with extractable two-by-two data. Two reviewers screened, extracted data and applied QUADAS-2. A bivariate generalised linear mixed model gave summary sensitivity and specificity, and exploratory subgroup analysis and meta-regression tested antibody clone, anatomical site and reference-standard type. Twenty-three studies (1216 SFT and 4715 comparators) were included. Summary sensitivity was 98.7% (95% confidence interval 96.7-99.5) and specificity 99.1% (97.8-99.6); the diagnostic odds ratio was approximately 8656. The monoclonal YE361 subgroup (8 studies) reached specificity 99.9% (99.3-100), with one false positive among 861 comparators, versus 98.1% (96.0-99.1) for polyclonal and other antibodies. False positives concentrated in dedifferentiated liposarcoma and prostatic stromal tumours. Estimates were stable after removing studies at higher risk of bias (98.9%/99.1%) and on leave-one-out analysis; the Deeks test was non-significant (p&#xa0;=&#xa0;0.08). Nuclear STAT6 immunohistochemistry is therefore highly sensitive and specific for SFT, and the residual specificity loss is structured and largely avoidable: the monoclonal YE361 read at a strict nuclear threshold is preferred, with MDM2 and CDK4 applied to exclude dedifferentiated liposarcoma when nuclear STAT6 is unexpectedly positive.

Humans↗

Malaria rapid diagnostic tests: performance, pitfalls, and progress.

PURPOSE OF REVIEW: Malaria rapid diagnostic tests (RDTs) have revolutionized malaria diagnosis in endemic settings. RDTs are simple to use and accurate for clinical cases, although sensitivity is reduced at parasite densities below 200&#x200a;parasites/&#x3bc;l. However, increasing prevalence of hrp2/3 gene deletions in certain areas threaten utility of histidine-rich protein 2 (HRP2)-based RDTs, and lingering HRP2 antigenemia can generate false-positive results after parasite clearance. This review summarizes current performance of malaria RDTs, threats to their validity, and recent innovations to improve their performance and continued role in malaria diagnosis. RECENT FINDINGS: Most World Health Organization (WHO) prequalified RDTs perform well for clinical diagnosis, with only occasional exceptions, including a recently reported issue affecting several countries. RDT sensitivity is generally related to malaria transmission intensity, with higher proportions of false-negative results in lower-transmission areas. Newly prequalified lactate dehydrogenase (pLDH)-based RDTs perform well for both Plasmodium falciparum in areas with >5% hrp2/3 gene deletions&#xa0;and for Plasmodium vivax diagnosis. Several point-of-care alternatives to RDTs, including micro-fluidic devices, hemozoin-detecting devices, and automated hematology analyzers, have shown promising results in small studies, but require larger-scale trials before widespread use. SUMMARY: RDTs remain a critical tool in clinical diagnosis of malaria, and newer pLDH-based tests perform well in areas where hrp2/3 gene deletions threaten validity of HRP2-based RDTs.

Humans↗

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans↗

Evaluation of one-step amplicon-based targeted enrichment for SARS-CoV-2 whole-genome sequencing using the Midnight amplicon scheme.

Genomic surveillance proved invaluable during the COVID-19 pandemic for tracking SARS-CoV-2 variants and guiding outbreak responses, underscoring the ongoing need to reduce whole-genome sequencing (WGS) costs and improve workflow efficiency to ensure accessibility in resource limited settings. Here, we evaluated a one-step reverse transcription polymerase chain reaction (RT-PCR) approach using the Midnight V2 primer scheme for targeted amplification of the SARS-CoV-2 genome, assessed its compatibility with Illumina sequencing, and compared its performance to a well-established two-step method. Initially, we determined optimal RT-PCR reaction conditions using the Midnight V2 primer panel for the one-step RT-PCR kit and scaled reaction volumes for both RT-PCR and library preparation. Clinical specimens (n&#x202f;=&#x202f;53) that had undergone routine WGS for surveillance purposes using the established two-step RT-PCR method were compared using the one-step RT-PCR assay. For samples with genome completeness greater than 70%, both methods gave comparable results with similar sequence coverage and 100% concordance for lineage assignment. Further investigation revealed a higher percentage of reads aligning to the SARS-CoV-2 genome with a greater depth of coverage using the one-step method compared to the two-step method. Finally, analysis of scaled one-step and library reaction volumes revealed significant cost savings for samples undergoing WGS. Overall, the results presented here verify the accuracy and reproducibility of one-step targeted amplification and offer an efficient and cost-effective workflow for routine SARS-CoV-2 genomic surveillance.

Humans↗