Search PubMed⌕ Search

PubMed · 9768388

Consultation section. Refractive surgical problem.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1998. Consultation section. Refractive surgical problem.. https://pubmed.ncbi.nlm.nih.gov/9768388/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Late-onset laser in situ keratomileusis (LASIK) flap dehiscence during retinal detachment surgery.

PURPOSE: To report a case of laser in situ keratomileusis (LASIK) flap dehiscence during retinal detachment surgery 7 months after uneventful refractive surgery. DESIGN: Interventional case report. METHODS: A 47-year-old man noticed a defect of the upper visual field in his right eye 7 months after a LASIK procedure. The fundus showed rhegmatogenous retinal detachment, and a scleral buckling procedure was performed. During the buckling procedure, the corneal flap became detached. RESULTS: At completion of the buckling procedure, the detached corneal flap was carefully raised and the exposed corneal stroma was cleansed of any residual epithelial cells or red blood cells with irrigation using balanced salt solution. One day after the operation, the LASIK flap was repositioned, the cornea had cleared, and the retina was reattached. CONCLUSIONS: As LASIK increases in popularity, the complication we have reported may become more common. We suggest that a retinal detachment surgery should be performed with careful avoidance of corneal trauma even if a long time has passed since the LASIK procedure.

Corneal Stroma↗

Corneal flap displacement and drift in LASIK: comparison of Hansatome and Automated Corneal Shaper microkeratomes.

PURPOSE: To describe and compare the displacement of corneal flaps created during laser in situ keratomileusis (LASIK) procedures performed with two different microkeratomes and analyze parameters (for example, pupil-to-hinge distance, drift during suction) that might affect the flap displacement or be influenced by flap displacement. DESIGN: This work was based on a cross-sectional study design. METHODS: Images copied from video recordings of 206 consecutive LASIK surgeries were analyzed to determine the distance from pupil center to corneal flap hinge (pupil-to-hinge distance), the hinge size, the distance from the center of the pupil to the margins of the flap, and the positions of the suction ring before and after vacuum in corneal flaps created by the Hansatome and the Automated Corneal Shaper (ACS) microkeratomes. Accurate measurements of all these variables could be obtained in 121 eyes (Hansatome: n = 66, right eye (OD) = 27 eyes, left eye (OS) = 39 eyes; ACS: n = 55, OD = 25 eyes, OS = 30 eyes), which were included in the analysis. Formulas were derived to calculate from the measurements the magnitude and direction of the drift of the suction ring during vacuum and the final displacement of the corneal flap. RESULTS: The mean +/- standard deviation (SD) drift of eyes during suction with the Hansatome was 0.27 +/- 0.02 mm and with the ACS was 0.12 +/- 0.02 mm (P <.001). The Hansatome induced, on average, more biased (temporal vs random) drift than did the ACS. The mean final displacement of the center of the flap from the center of the pupil was of equal magnitude for the two instruments (0.37 +/- 0.02 mm and 0.36 +/- 0.02 mm with the Hansatome and ACS, respectively). CONCLUSION: The drift induced by the Hansatome contributes to the horizontal component of the final decentration of the corneal flaps. This tendency for drift and the resultant decrease in pupil-to-hinge distance should be considered to minimize flap displacements during LASIK.

Corneal Stroma↗