Search PubMed⌕ Search

PubMed · 9328692

X-ray-ted.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Brinker. 1997. X-ray-ted.. https://doi.org/10.1002/(sici)1097-0304(199710)42%3A2%3C128%3A%3Aaid-ccd6%3E3.0.co%3B2-f

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional flow reserve.

The functional significance of coronary artery stenoses of intermediate severity is important in determining strategy in patient care. Intravascular ultrasound (IVUS) is often used to evaluate coronary stenosis severity. However, at present, few data are available about the role IVUS in the assessment of functional significance of intermediate lesions. Myocardial fractional flow reserve (FFR) <0.75 is a reliable index of a functionally severe coronary stenosis. In 53 lesions we assessed (1) by pressure wire: FFR (index of functional significance), and (2) by IVUS: minimal lumen cross-sectional area (MLA, square millimeters), minimal lumen diameter (MLD, millimeters), lesion length (millimeters), and percent area stenosis at the lesion site. By regression analysis, percent area stenosis and lesion length had a significant inverse correlation with FFR (r = -0.58, p <0.001, r = -0.41, p <0.004, respectively). MLD and MLA showed a significant positive relation with FFR (r = 0.51, p <0.001, r = 0.41, p <0.004, respectively). By using a receiver operating characteristic (ROC) curve, we identified a percent area stenosis > 70% (sensitivity 100%, specificity 68%), a MLD < or = 1.8 mm (sensitivity 100%, specificity 66%), a MLA < or =4.0 mm2 (sensitivity 92%, specificity 56%), and a lesion length of >10 mm (sensitivity 41%, specificity 80%) to be the best cut-off values to fit with a FFR <0.75. The combined evaluation of both percent area stenosis and MLD made the IVUS examination more specific (sensitivity 100%, specificity 76%). In 53 intermediate coronary lesions found by angiography, IVUS area stenosis >70%, MLD < or =1.8 mm, MLA < or =4.0 mm2, and lesion length > 10 mm reliably identified functionally critical intermediate coronary stenoses.

Cardiac Catheterization↗

Cardiac catheterization laboratory imaging quality assurance program.

With the recent approval of the National Electrical Manufacturers Association (NEMA) standard for "Characteristics of and Test Procedures for a Phantom to Benchmark Cardiac Fluoroscopic and Photographic Performance," comprehensive cardiac image assurance control programs are now possible. This standard was developed by a joint NEMA/Society for Cardiac Angiography and Interventions (SCA&I) working group of imaging manufacturers and cardiology society professionals over the past 4 years. This article details a cardiac catheterization laboratory image quality assurance and control program that includes the new standard along with current regulatory requirements for cardiac imaging. Because of the recent proliferation of digital imaging equipment, quality assurance for cardiac imaging fluoroscopy and digital imaging are critical. Included are the previous works recommended by the American College of Cardiology (ACC) and American Heart Association (AHA), Society for Cardiac Angiographers and Interventions (SCA&I), and authors of previous image quality subjects.

Cardiac Catheterization↗