Search PubMed⌕ Search

PubMed · 8870059

3D object localization using EIT measurements at two levels.

Abstract

Electrical impedance tomography (EIT) is designed essentially for two-dimensional imaging, but current flow in the third dimension causes images to be formed for objects in 3D. The present work has shown that the image of an object is shifted in position towards the centre almost linearly with the 3D distance from the electrode plane and that the slope of this linear variation depends on the radial distance of the object. An empirical curve has been fitted to this dependence, based on which a method has been developed to locate 3D point objects from EIT measurements in only two planes. This will be useful in clinical and other applications in which 3D objects are few and widely separated. This new methodology may be the basis for 3D imaging in the future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K S Rabbani, M Hassan, A Kiber. 1996. 3D object localization using EIT measurements at two levels.. https://doi.org/10.1088/0967-3334%2F17%2F3%2F005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Impedance analyser module for EIT and spectroscopy using undersampling.

In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware for voltage and current measurement, early signal digitization and subsequent digital signal processing in order to calculate the components of impedance (or admittance). At low frequencies, the module utilizes the conventional direct conversion method, whereas at high frequencies the undersampling technique is used. The advantages of the described system are the following: (a) the frequency range is extended to higher frequencies, (b) the number of data sampled per time interval is significantly reduced, and (c) the current consumption and the costs of the ADCs can be significantly reduced. The validation procedure is performed by comparing the measured and theoretical values of the magnitude and the phase of the impedance for a commonly used tissue model. The module offers an accuracy of better than 0.012% for the magnitude of impedance and better than 0.02 degrees for the phase.

Electric Impedance↗

Mk3.5: a modular, multi-frequency successor to the Mk3a EIS/EIT system.

This paper describes the Sheffield Mk3.5 EIT/EIS system which measures both the real and imaginary part of impedance at 30 frequencies between 2 kHz and 1.6 MHz. The system uses eight electrodes with an adjacent drive/receive electrode data acquisition protocol. The system is modular, containing eight identical data acquisition boards, which contain DSPs to generate the drive frequencies and to perform the FFT used for demodulation. The current drive is in three sequentially applied packets, where each packet contains ten summed sine waves. The data acquisition system is interfaced to a host PC through an optically isolated high speed serial link (RS485) running at 2 Mbaud (2 Mbits s(-1)). Measurements on a saline filled tank show that the average signal to noise performance of the system is 40 dB measured across all frequencies and that this figure is independent of frequency of measurement. These results suggest that the current system is 10 dB better in absolute terms than the previous Sheffield (Mk3a) system.

Electric Impedance↗

Generalized optimal current patterns and electrical safety in EIT.

There are a number of constraints which limit the current and voltages which can be applied on a multiple drive electrical imaging system. One obvious constraint is to limit the maximum ohmic power dissipated in the body. Current patterns optimizing distinguishability with respect to this constraint are singular functions of the difference of transconductance matrices with respect to the power norm (the optimal currents of Isaacson). If one constrains the total current (L1 norm) the optimal patterns are pair drives. On the other hand if one constrains the maximum current on each drive electrode (an L(infinity) norm), the optimal patterns have each drive channel set to the maximum source or sink current value. In this paper we consider appropriate safety constraints and discuss how to find the optimal current patterns with those constraints.

Electric Impedance↗