Focused impedance measurement (FIM). A new technique with improved zone localization.

Conventional four-electrode impedance measurements (FEIM) cannot localize a zone of interest in a volume conductor. On the other hand, the recently developed electrical impedance tomography (EIT) system offers an image with reasonable resolution, but is complex and needs many electrodes. By placing two FEIM systems perpendicular to each other over a common zone at the center and combining the two results, it is possible to obtain enhanced sensitivity over this central zone. This is the basis of the proposed new method of focused impedance measurement (FIM). Sensitivity maps in both 2D and 3D show the desired improvement. A comparison of stomach-emptying studies also indicates the improvement achieved. This new method may be useful for impedance measurements of large organs like stomach, heart, and lungs. Being much simpler in comparison to EIT, multifrequency systems can be simply built for FIM. Besides, FIM may have utility in other fields like geology where impedance measurements are performed.

Diagnostic Imaging↗

Pulsed electromagnetic fields for the treatment of bone fractures.

The effectiveness of electrical stimulation and Pulsed Electro Magnetic Field (PEMF) stimulation for enhancement of bone healing has been reported by many workers. The mechanism of osteogenesis is not clear, therefore, studies look for empirical evidence. The present study involved a clinical trial using low amplitude PEMF on 19 patients with non-union or delayed union of the long bones. The pulse system used was similar in shape to Bassett's single pulse system where the electric voltage pulse was 0.3 mSec wide repeating every 12 mSec making a frequency of about 80 Hz. The peak magnetic fields were of the order of 0.01 to 0.1 m Tesla, hundred to thousand times smaller than that of Bassett. Among the 13 who completed this treatment schedule the history of non-union was an average of 41.3 weeks. Within an average treatment period of 14 weeks, 11 of the 13 patients had successful bone healing. The two unsuccessful cases had bone gaps greater than 1 cm following removal of dead bone after infection. However, use of such a low field negates Bassett's claim for a narrow window for shape and amplitude of wave form, and justifies further experimental study and an attempt to understand the underlying mechanism.

Adolescent↗

Noninvasive assessment of gastric acid secretion in man. Application of electrical impedance tomography (EIT).

Electrical impedance tomography (EIT) is a tubeless technique that generates tomographic images of gastric resistivity. We investigated the application of EIT to measure gastric acid secretion. Nineteen normal subjects underwent a standard intubation test. Basal acid output (BAO) and stimulated acid output (SAO) (millimoles per hour) were measured before and after pentagastrin, respectively. On a different day, EIT was performed before (basal) and after pentagastrin (stimulated). The changes in impedance over time were measured and the area under the curve (AUC) was calculated. Both the tests were repeated in 13 subjects after omeprazole treatment. As in the intubation test, there was the expected increase in AUC value after pentagastrin (basal vs stimulated; 1.2 +/- 2.8 vs 731 +/- 297, P < 0.0001). A significant fall in acid output and AUC following omeprazole pretreatment was observed (without vs with omeprazole; 20.5 +/- 5.7 vs 0.03 +/- 0.06, P < 0.0001 for intubation test and 731 +/- 297 vs 44 +/- 172, P < 0.0001 for EIT). There was a significant correlation between SAO and the delta AUC with (r = 0.65 P < 0.001) or without (r = 0.95, P < 0.001) omeprazole and in all the experiments (r = 0.87, P < 0.001). This study demonstrates the predictable change of gastric impedance and may be useful as a noninvasive test for measuring gastric acid secretion.

Adolescent↗

3D object localization using EIT measurements at two levels.

Electrical impedance tomography (EIT) is designed essentially for two-dimensional imaging, but current flow in the third dimension causes images to be formed for objects in 3D. The present work has shown that the image of an object is shifted in position towards the centre almost linearly with the 3D distance from the electrode plane and that the slope of this linear variation depends on the radial distance of the object. An empirical curve has been fitted to this dependence, based on which a method has been developed to locate 3D point objects from EIT measurements in only two planes. This will be useful in clinical and other applications in which 3D objects are few and widely separated. This new methodology may be the basis for 3D imaging in the future.

Electric Impedance↗

Effect of PEMF on fresh fracture-healing in rat tibia.

The present experiment was designed to find out whether PEMF can act as a healing agent on induced fracture of rat tibia. Eighty rats were taken for this experiment. Under general anaesthesia mid-shaft of tibia and fibula of all rats were osteotomied, Intramedullary nailing was done for proper alignment of the fractured fragments. The animals were then divided into two groups: group-1 and Group-II. Each group contained forty animals. Out of these forty animals twenty were treated as experimental and twenty as control. From the third day of osteotomy, PEMF was applied to experimental rats around the osteotomy sites for a period of nine hours a day. PEMF was not applied to the control rats. The animals of group-1 and group-II were sacrificed after applied one week and three weeks of PEMF, respectively. Radiological and microscopical examination of the callus were performed. Gross and microscopic measurements of the callus were statistically analysed. The growth of callus was taken as a criterion of fracture healing. The results of the present experiment revealed significant enhancement of fracture healing in group-I. The results of the radiological evaluation of group-II experimental animals were also consistent with the morphological analysis. It was concluded that healing of fractured rat tibia was enhanced by the application of PEMF and this effect of PEMF was more pronounced at the end of third week.

Animals↗

Studies on the effect of the third dimension on a two-dimensional electrical impedance tomography system.

This work is based on the Applied Potential Tomography (APT) system developed in Sheffield and the results specifically relate to this system. Using a cylindrical phantom containing saline, the effects of extended layers in the third dimension on the two-dimensional tomographic images have been studied. Experimentally obtained magnitudes of pixel values corresponding to different conditions in the third dimension are presented. Analysis of these data brings out two phenomena: (i) layers of changed resistivity out of the electrode plane can appear as both increased and decreased resistivity in the image; and (ii) the position of the maximum resistivity change in the image occurs at increasing distances from the edge of the phantom, as the layers of resistivity change are introduced further from the electrode plane and they have a one to one relationship. An intuitive interpretation related to perturbation of equicurrent surfaces in the third dimension has been suggested to explain these phenomena.

Humans↗

Effect of pulsed electromagnetic field on healing of experimental nonunion in rat tibiae.

To see the effect of Pulsed Electromagnetic Field (PEMF) on nonunited fracture healing, nonunion was induced in rat tibiae and PEMF was applied on it. Out of five different techniques utilised for inducing nonunion soft tissue interposition was found to be the most suitable and effective method of experimental induction of nonunion. Twenty eight experimental and 15 control rats were finally evaluated for the effect of PEMF applied for up to 8 weeks. After sacrifice of 8 experimental and 4 controls, 6 experimental and 3 controls, again 6 experimental and 3 controls and finally 8 experimental and 5 controls at 2, 4, 6 and 8 weeks respectively of PEMF application no significant difference as to the quality of healing was observed between the experimental and control animals. It was thus concluded that PEMF appeared to have no beneficial effect on the healing of nonunited fractures in experimental set-up.

Animals↗