Impedance analyser module for EIT and spectroscopy using undersampling.

Abstract

In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware for voltage and current measurement, early signal digitization and subsequent digital signal processing in order to calculate the components of impedance (or admittance). At low frequencies, the module utilizes the conventional direct conversion method, whereas at high frequencies the undersampling technique is used. The advantages of the described system are the following: (a) the frequency range is extended to higher frequencies, (b) the number of data sampled per time interval is significantly reduced, and (c) the current consumption and the costs of the ADCs can be significantly reduced. The validation procedure is performed by comparing the measured and theoretical values of the magnitude and the phase of the impedance for a commonly used tissue model. The module offers an accuracy of better than 0.012% for the magnitude of impedance and better than 0.02 degrees for the phase.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Dudykevych, E Gersing, F Thiel, G Hellige. 2001. Impedance analyser module for EIT and spectroscopy using undersampling.. https://doi.org/10.1088/0967-3334%2F22%2F1%2F303

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantification of pore induction in human epidermal membrane during iontophoresis: the importance of background electrolyte selection.

It has been shown that significant pore induction (electroporation) occurs in human epidermal membrane (HEM) during iontophoresis even at moderate applied voltages (1-10 V). Recent efforts in our laboratory have been aimed at quantifying HEM electroporation by examining the proportionality between flux enhancement due to electroporation and electrical conductance changes during iontophoresis. The specific purpose of the present study was to test the hypothesis that by matching the background electrolyte ion sizes with the permeant ion sizes, the flux enhancement due to electroporation can be quantified by the change in HEM electrical conductance. In this study, radiolabeled tetraethylammonium (TEA(+)), methylammonium (MA(+)), and mannitol were the permeants. Potassium chloride (KCl), tetraethylammonium bromide (TEAB), tetraethylammonium pivalate (TEAP), and sodium fluoride (NaF) were the background electrolytes. Iontophoresis experiments were carried out over an applied voltage range of 1 to 3 V. The experimental flux enhancement results were compared with the theoretical predictions from the Nernst-Planck model after corrections were made: (a) for HEM pore induction during iontophoresis based on electrical conductance changes and (b) for electroosmosis employing mannitol as the neutral probe permeant. In experiments where the ion sizes of the background electrolyte and permeant were closely matched (e.g., TEA(+) as the permeant and TEAP as the background electrolyte), there was excellent agreement between experimental results and theoretical predictions of the modified Nernst-Planck model, with only modest data scatter. When the electrolyte and permeant sizes were quite different (e.g., TEA(+)/KCl and MA(+)/TEAP), the experimental flux data were inconsistent with model predictions and there were large variations in the experimental results. The results of the present study illustrate that permeant flux enhancement can be predicted by the modified Nernst-Planck model even during moderate voltage iontophoresis when electroporation is operative.

Electric Impedance↗

Front-end architecture for a multi-frequency electrical impedance tomography system.

This paper provides a critical review of a number of the primary aspects of EIT system hardware presented in the literature. A thorough analysis of injection and measurement errors is presented to provide clarifying extensions to that provided by previous authors. From this basis, it proposes a novel design for a distributed parallel multi-frequency EIT system. The system described is modular, employs active electrodes to maximise CMRR (common mode rejection ratio) and was designed to employ digitally generated current injection and digital demodulation of the acquired signals.

Electric Impedance↗

Do battery depletion indicators reliably predict the need for pulse generator replacement?

The aim of this study was to test the validity of battery depletion indicators to forecast end of service (EOS) in dual chamber pulse generators (PG). Two additional approaches for prediction of EOS were evaluated as well: the real-time telemetry of cell impedance and a battery stress test (BST) that used a transitory increase in pacing rate. The study population consisted of 119 patients with Intermedics dual chamber PG models Cosmos II and Relay, in which cell impedance had exceeded 2.5 k omega. The patients were followed in 6-month intervals. If the interrogation of the PG or the BST prompted the appearance of the intensified follow-up indicator (IFI), the next follow-up was scheduled within 2 months. PG replacement was performed on physician's discretion or immediately on appearance of the elective replacement indicator (ERI), regardless of the method of ERI provocation. During a period of 2 years/and 9 months, 33 patients underwent PG replacement. Out of 21 patients with positive ERI indicators, only 5 had positive warning indicators of approaching battery depletion in the preceding follow-up (IFI during BST, n = 4; ERI during BST n = 1). The majority of patients (n = 16, 76%) revealed ERI without prior activation of IFI, neither spontaneous nor during the BST. Four of these 16 ERI-positive patients had cell impedance values far below the ERI limits of the manufacturer. Based on battery depletion indicators, an exact prediction of EOS of dual chamber pacemakers is not possible. Measuring battery impedance allows for a statistical estimation of remaining service life but it may be misleading in the individual case. A BST that is based on a temporary increase of pacing rate is invalid in forecasting battery depletion. As activation of the ERI can trigger an abrupt change to the VVI backup mode, pacemaker dependent patients with low programmed basic pacing rates may be hemodynamically compromised by an unexpected activation of ERI. Close monitoring intervals and PG replacement before appearance of the ERI is recommended in those patients.

Electric Impedance↗