Search PubMed⌕ Search

PubMed · 8664509

Does re-exposure to mismatched HLA antigens decrease renal re-transplant allograft survival?

Abstract

UNLABELLED: We analyzed 420 kidney retransplants at the University of Minnesota, 87 of which did and 333 which did not share HLA mismatches with the previous transplant. There was no difference in outcome. We conclude that exceptions to routine HLA matching policies do not have to be made for kidney retransplants. OBJECTIVE: To determine if the kidney graft functional survival rate for retransplants is influenced by presence of HLA mismatches in common with the previous (failed) transplant. SUMMARY BACKGROUND DATA: Kidney retransplants have a lower function rate than primary grafts. An anamnestic response to HLA antigens shared with the previous donor could be one factor responsible, but reports in the literature are conflicting. METHODS: Of 420 kidney retransplants with HLA information done at the University of Minnesota, 87 shared > or = 1 HLA antigens specifically mismatched with the previous donor (63 cadaver and 24 living donor retransplants), while 333 did not (247 cadaver, 86 living donor). Patient and graft survival rates were calculated by life-table analysis for recipients with vs. without repeat mismatches, with the significance of differences determined by the Lee-Desu statistic. RESULTS: Patient and kidney graft retransplant survival rate curves were not significantly different (p > or = 0.41) for those exposed or not exposed to the same HLA mismatches as before. At 2 years, 70% vs. 61%, respectively, of cadaver grafts and 71% vs. 78%, respectively, of living donor grafts were functioning. CONCLUSIONS: The probability of a successful outcome with a kidney retransplant is no different for patients who do than for those who do not receive an organ sharing HLA mismatches with the previous donor. Exceptions to routine HLA matching policies do not need to be made for kidney retransplants.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A C Farney, A J Matas, H J Noreen, N Reinsmoen, M Segall, W J Schmidt, K Gillingham, J S Najarian, D E Sutherland. 1996. Does re-exposure to mismatched HLA antigens decrease renal re-transplant allograft survival?. https://pubmed.ncbi.nlm.nih.gov/8664509/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An anatomic study of the lumbar plexus with respect to retroperitoneal endoscopic surgery.

STUDY DESIGN: The distribution of the lumbar plexus was analyzed using cadavers. OBJECTIVE: To clarify the safety zone to prevent nerve injuries with respect to retroperitoneal endoscopic surgery. SUMMARY OF BACKGROUND DATA: Surgical approaches to the retroperitoneal space vary among surgeons. Recently, retroperitoneal endoscopic surgery has been applied to various spinal disorders. When the psoas major muscle is separated during retroperitoneal endoscopic surgery, there is a potential risk of injury to the lumbar plexus or nerve roots. However, there is sparse knowledge regarding the relationship between the greater psoas muscle and the lumbar plexus. METHODS: A total of 30 cadavers were analyzed. Six lumbar spines of the cadavers were cut in parallel with the lumbar disc space. Each axial section was photographed and captured into a computer. The distribution of the lumbar plexus was analyzed using computer images. The positions where the genitofemoral nerve emerged on the abdominal surface of the psoas major muscle were analyzed using 24 cadavers. RESULTS: L2/3 and above, all parts of the lumbar plexus, and nerve roots were located from the dorsal fourth of the vertebral body and dorsally. The genitofemoral nerve descends obliquely forward through the psoas major muscle, emerging on the abdominal surface between the cranial third of the L3 vertebra and the caudal third of the L4 vertebra. The safety zone of the psoas major muscle to prevent nerve injuries, excluding the genitofemoral nerve, is at L4/L5 and above. CONCLUSIONS: The safety zone, excluding the genitofemoral nerve, is at L4-L5 and above.

Cadaver↗

[Hepatic artery system variations correlated to split-liver surgery: anatomic study in cadavers].

BACKGROUND: The liver donor shortage and the higher demand on liver transplantation led to advanced liver surgery techniques in order to better utilization of the cadaveric liver donors. That is why the split-liver technique had been applicated in liver transplantation where the liver after been divided into two lobes would be implanted in two recipients. AIMS: This paper has the goal of study both the extra-hepatic arterial distribuition and anatomie of the liver with application on the split-liver transplantation separating the liver in right and left hepatic lobe. PATIENTS AND METHODS: The authors studied 60 livers from fresh cadaver looking at hepatic artery and its main anatomic variations correlating with split-liver surgery. The liver was split into two portions, right and left lobe. RESULTS: The total liver weight was 1536 +/- 361,8 g, right hepatic lobe 890,3 +/- 230,9 g and left hepatic lobe 649,3 +/- 172,6 g. Common hepatic trunk was found in one (1,6%) case and came from superior mesenteric artery and in another one (1,6%), both left hepatic artery and left gastric artery came from the abdominal aorta. The right hepatic artery raised from celiac trunk in 44 (73,3%) cases, and in 15 (25%) from superior mesenteric artery it was acessory in 11 (18,3%) cases and dominant in 4 (6,6%). The left hepatic artery was acessory of left gastric artery in 2 (3,3%) cases. Hepatic artery trifurcation was found in 9 (15%) cases out of this 6 (10%) to segment IV, 2 (3,3%) to segment III and 1 (1,6%) to segment II. Also we found 2 (3,3%) medium hepatic artery to segment IV. CONCLUSION: Hepatic artery variations allowed liver section into right and left hepatic lobe.

Cadaver↗

A contact lens as an artificial cornea for improved visualization during practice surgery on cadaver eyes.

OBJECTIVE: To describe the use of a polymethylmethacrylate contact lens as an artificial cornea to enhance visualization for practice surgery using cadaver eyes. DESIGN: The opaque cornea of a cadaver eye is removed by trephination. Cyanoacrylate glue is used to secure a large-diameter polymethylmethacrylate contact lens to the corneal rim. RESULTS: Excellent visualization for practice surgery is achieved with this technique. The adhesion of the contact lens to the cadaver eye maintains the anterior chamber sufficiently to perform phacoemulsification cataract extraction or pars plana vitrectomy. CONCLUSIONS: This technique improves visualization of the intraocular structures during practice surgery, thereby enhancing the ability of the learning surgeon to perform and practice delicate surgical maneuvers. The procedure is simple, effective, and inexpensive.

Cadaver↗