Automatic fracture reduction with a computer-controlled external fixator.

Abstract

The reduction of fractures by means of an Ilizarov's fixator is obtained by successively shortening or lengthening the rods. This entails that all reduction operations of the fracture stumps be performed with a series of empirical attempts, requiring great experience and manual dexterity in the surgeon. Moreover this process involves a long exposure of both physician and patient to potentially harmful radiation due to the continuous checking of the intermediate positions on the X-ray image intensifier. In order to overcome these limits a new device has been conceived, based on the application of three stepper-motors on three-rods. Its basic principle is functionally very similar to Ilizarov's prototype. The relative motions between the two frames are carried out by controlling the three actuators with a computer, which processes the number of required steps on the basis of an algorithm, starting from a few inputs supplied by the surgeon. This article illustrates the functional kinematic study necessary for the complete automation of the reduction process. Also considered is the complex problem of the reduction trajectory definition, intended as a sequence of configurations of partial correction, obtained by formalizing in geometrical terms the empirical criteria followed by the orthopaedic surgeon in reducing fractures. Such a sequence is intended to be a suggestion for the surgeon who can visualize and possibly interact with the system to determine a trajectory harmless for the soft tissues surrounding the bone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Viceconti, A O Andrisano, A Toni, A Giunti. 1994. Automatic fracture reduction with a computer-controlled external fixator.. https://doi.org/10.1016/1350-4533(94)90027-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Safety evaluation of large external fixation clamps and frames in a magnetic resonance environment.

Large orthopedic external fixation clamps and related components were evaluated for force, torque, and heating response when subjected to the strong electromagnetic fields of magnetic-resonance (MR) imaging devices. Forces induced by a 3-Tesla (T) MR scanner were compiled for newly designed nonmagnetic clamps and older clamps that contained ferromagnetic components. Heating trials were performed in a 1.5 and in a 3 T MR scanner with two assembled external fixation frames. Forces of the newly designed clamps were more than a factor 2 lower as the gravitational force on the device whereas, magnetic forces on the older devices showed over 10 times the force induced by earth acceleration of gravity. No torque effects could be found for the newly designed clamps. Temperature measurements at the tips of Schanz screws in the 1.5 T MR scanner showed a rise of 0.7 degrees C for a pelvic frame and of 2.1 degrees C for a diamond knee bridge frame when normalized to a specific absorption rate (SAR) of 2 W/kg. The normalized temperature increases in the 3 T MR scanner were 0.9 degrees C for the pelvic frame and 1.1 degrees C for the knee bridge frame. Large external fixation frames assembled with the newly designed clamps (390 Series Clamps), carbon fiber reinforced rods, and implant quality 316L stainless steel Schanz screws met prevailing force and torque limits when tested in a 3-T field, and demonstrated temperature increase that met IEC-60601 guidelines for extremities. The influence of frame-induced eddy currents on the risk of peripheral nerve stimulation was not investigated.

External Fixators↗