Publications and source records attributed to M Viceconti.

At least 19 recordsLinked to original sources

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Meniscal wear at a three-component total ankle prosthesis by a knee joint simulator.

Despite the fundamental value of wear simulation studies to assess wear resistance of total joint replacements, neither specialised simulators nor established external conditions are available for the human ankle joint. The aim of the present study was to verify the suitability of a knee wear simulator to assess wear rates in ankle prostheses, and to report preliminary this rate for a novel three-component total ankle replacement design. Four intact 'small' size specimens of the Box ankle were analysed in a four-station knee wear simulator. Special component-to-actuator holders were manufactured and starting spatial alignment of the three-components was sought. Consistent load and motion cycles representing conditions at the ankle joint replaced exactly with the prosthesis design under analysis were taken from a corresponding mechanical model of the stance phase of walking. The weight loss for the three specimens, after two million cycles, was 32.68, 14.78, and 62.28mg which correspond to a linear penetration of 0.018, 0.008, and 0.034mm per million-cycle, respectively for the specimens #1, #2, and #3. The knee wear simulator was able to reproduce load-motion patterns typical of a replaced ankle. Motion of the meniscal bearing in between the tibial and talar components was smooth, this component remaining in place and in complete congruence with the metal components throughout the test.

Ankle Joint↗

Multimodal visualization interface for data management, self-learning and data presentation.

A multimodal visualization software, called the Data Manager (DM), has been developed to increase interdisciplinary communication around the topic of visualization and modeling of various aspects of the human anatomy. Numerous tools used in Radiology are integrated in the interface that runs on standard personal computers. The available tools, combined to hierarchical data management and custom layouts, allow analyzing of medical imaging data using advanced features outside radiological premises (for example, for patient review, conference presentation or tutorial preparation). The system is free, and based on an open-source software development architecture, and therefore updates of the system for custom applications are possible.

Anatomy↗

A new software tool for 3D motion analyses of the musculo-skeletal system.

BACKGROUND: Many clinical and biomechanical research studies, particularly in orthopaedics, nowadays involve forms of movement analysis. Gait analysis, video-fluoroscopy of joint replacement, pre-operative planning, surgical navigation, and standard radiostereometry would require tools for easy access to three-dimensional graphical representations of rigid segment motion. Relevant data from this variety of sources need to be organised in structured forms. Registration, integration, and synchronisation of segment position data are additional necessities. With this aim, the present work exploits the features of a software tool recently developed within a EU-funded project ('Multimod') in a series of different research studies. METHODS: Standard and advanced gait analysis on a normal subject, in vivo fluoroscopy-based three-dimensional motion of a replaced knee joint, patellar and ligament tracking on a knee specimen by a surgical navigation system, stem-to-femur migration pattern on a patient operated on total hip replacement, were analysed with standard techniques and all represented by this innovative software tool. Segment pose data were eventually obtained from these different techniques, and were successfully imported and organised in a hierarchical tree within the tool. FINDINGS: Skeletal bony segments, prosthesis component models and ligament links were registered successfully to corresponding marker position data for effective three-dimensional animations. These were shown in various combinations, in different views, from different perspectives, according to possible specific research interests. INTERPRETATION: Bioengineering and medical professionals would be much facilitated in the interpretation of the motion analysis measurements necessary in their research fields, and would benefit therefore from this software tool.

Aged↗

On the biomechanical stability of cementless straight conical hip stems.

The aim of the present study was to investigation in vitro the effect of deficient bone-implant contact on the primary stability of a straight conical stem. Various possible deficient contact patterns were derived from surgical simulations. The effect of stair climbing loads on the bone-implant micromotion was firstly investigated using a finite element model and then an in vitro test aimed at assessing primary stability. It was found that if the surface features are prevented from biting dense bone in a few small but critical regions, stem primary stability is completely lost. These results suggest that the surface features used in the axisymmetric stem under investigation can be too sensitive to deficient contact conditions, and thus should be augmented with additional antirotational fins. Preliminary tests showed that a stem with the addition of such fins presents good primary stability in all tested conditions.

Arthroplasty, Replacement, Hip↗

The predictive power of surface profile parameters on the amount of wear measured in vitro on metal-on-polyethylene artificial hip joints.

Various studies report a weak correlation between the average surface roughness R(a) of metallic ballheads and the observed wear rate of the polyethylene cups coupled to them. The aim of this study is to verify, with controlled in vitro experiments, whether other parameters such as the total roughness R(t), and the skewness R(sk) are better predictors of the polyethylene wear when the metallic heads present a surface conditioning that varies substantially from specimen to specimen, as is usually the case with retrieved specimens. Twelve CoCrMo (cobalt-chromium-molybdenum) ballheads were intentionally damaged in order to reproduce a wide spectrum of surface conditioning and were then subjected to the standard wear test against polyethylene cups, using a hip joint wear simulator. After 2 x 10(6) cycles the weight lost by the cups was assessed with a gravimetric procedure, and the surface roughness of the metallic ballheads was qualified in terms of R(a), R(t), and R(sk). The various parameters were correlated to the weight loss using a linear regression analysis. The skewness R(sk) showed a coefficient linear regression R2 = 0.80, while the average roughness R(a), used in most previous studies, presented an R2 = 0.56. It was concluded that when specimens with substantially different surface conditioning are compared, as in retrievals analysis, it is also important to report the skewness R(sk) so that qualify the surface roughness of the specimens can be qualified.

Coated Materials, Biocompatible↗

Outlook for grid service technologies within the @neurIST eHealth environment.

The aim of the @neurIST project is to create an IT infrastructure for the management of all processes linked to research, diagnosis and treatment development for complex and multi-factorial diseases. The IT infrastructure will be developed for one such disease, cerebral aneurysm and subarachnoid haemorrhage, but its core technologies will be transferable to meet the needs of other medical areas. Since the IT infrastructure for @neurIST will need to encompass data repositories, computational analysis services and information systems handling multi-scale, multi-modal information at distributed sites, the natural basis for the IT infrastructure is a Grid Service middleware. The project will adopt a service-oriented architecture because it aims to provide a system addressing the needs of medical researchers, clinicians and health care specialists (and their IT providers/systems) and medical supplier/consulting industries.

Database Management Systems↗

Evaluation of achievable registration accuracy of the femur during minimally invasive total hip replacement.

The aim of the paper was to investigate whether accurate, point-based registration of the intra-operative femur will be achieved within the context of minimally invasive surgery for total hip replacement. Computer tomography images, collected for pre-operative planning purposes, were used to simulate the intra-operative registration procedure using algorithms for various levels of measurement noise, different small areas of the femur available to the surgeon, and a limited number of collected data points (20-60). This helped with the choice of design variables to perform in vitro registration on a plastic bone model to validate the procedure, which included a multistart algorithm developed for intra-operative registration. The algorithm minimised the distance between the measured and image-derived surfaces and was able to cope with the presence of multiple local minima given sufficient computational effort, even with realistically large measurement noise. It was found that, if a small patch of the femur was used, accessible by a needle that could at times penetrate thin layers of soft tissue, errors in the order of 1.0 mm in translation and 0.5 degrees in rotation were achievable.

Algorithms↗

Kinematic study of a reconstructed hip in paediatric oncology.

In 1997, a large portion of the femur of a four-year-old child affected by a Ewing's sarcoma was reconstructed with an innovative technique that used a massive bone allograft, in conjunction with a vascularised fibula autograft that was directly articulated within the acetabulum. The aim of the present study was to assess the kinematic behaviour of the reconstructed hip during flexion, once the acute remodelling process observed after the operation had ceased. A few additional CT slices of the hip joint region, in a flexed position, were taken at month 33 of the follow-up. The helical axes relative to the neutral-flexion motor action were estimated: their relative positions, with respect to the anatomical femoral heads, were compared, and the translation of the anatomical head centres was estimated. The angles spanned by the two femurs were almost equal, as were the translations along the respective helical axis. The main difference between the two femurs was the distance between the estimated femoral head centres and the relative helical axes. This resulted in a non-negligible translation of 2.9 mm of the fibula head inside the acetabulum during flexion, significantly higher than the 0.5 mm found for the intact contralateral femur. The results showed that, although the transplanted fibula grew and remodelled during the follow up, the action of the reconstructed hip joint still cannot be described as a ball-and-socket.

Biomechanical Phenomena↗

Advanced multimodal visualisation of clinical gait and fluoroscopy analyses in the assessment of total knee replacement.

Traditional gait and fluoroscopy analysis of human movement are largely utilised but are still limited in registration, integration, synchronisation and visualisation capabilities. The present work exploits the features of a recently developed software tool based on multimodal display (Data Manager developed within the EU-funded project 'Multimod') in an exemplary clinical case. Standard lower limb gait analysis, comprising segment position, ground reaction force and EMG data collection, and three-dimensional fluoroscopy analysis at the replaced joint were performed in a total knee replacement patient while ascending stairs. Clinical information such as X-rays and standard scores were also available. Data Manager was able to import all this variety of data and to structure these in an original hierarchical tree. Bone and prosthesis component models were registered to corresponding marker position data for effective three-dimensional animations. These were also synchronised with corresponding standard video sequences. Animations, video, time-histories of collected and also processed data were shown in various combinations, according to specific interests of the bioengineering and medical professionals expected to observe and to interpret this large amount of data. This software tool demonstrated to be a valuable means to enhance representation and interpretation of measurements coming from human motion analysis. In a single software, a thorough and effective clinical and biomechanical analysis of human motion was performed.

Arthroplasty, Replacement, Knee↗

Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

A numerical model able to investigate the influence of biomechanical factors on the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discrete-states machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62% (distal fit) and 78% (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75%, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.

Arthroplasty, Replacement, Hip↗

Numerical model to predict the long-term mechanical stability of cementless orthopaedic implants.

The objective of this research was to develop a purely biomechanical model, intended to predict the long-term secondary stability of the implant starting from the biomechanical stability immediately after the operation. A continuous rule-based adaptation scheme was formulated as a dynamic system, and the work verified if such a model produced unique and clinically meaningful solutions. It also investigated whether this continuous model provided results comparable with those of a simpler, discrete-states model used in a previous study. The proposed model showed stable convergence behaviour with all investigated initial conditions, with oscillatory behaviour limited to the first steps of the simulation. The results obtained with the wide range of initial conditions support the hypothesis of the existence and uniqueness of the solution for all initial conditions. The differences between the continuous model and the simpler and more efficient finite-states model were found to be extremely modest (less than 4% over the predicted bonded area). Because of these minimal differences, the use of the much faster finite-states model is recommended to investigate asymptotic conditions, and the continuous model described should be used to investigate the evolution over time of the adaptive process.

Adaptation, Physiological↗

A procedure and criterion for bone cement fracture toughness tests.

Nowadays, two procedures, based on the recommendation of two American standards (ASTM E399 and ASTM D5045), are used to determine the fracture toughness, KIc, of bone cement. However, there is a lack of knowledge about the equivalence of the two testing methods applied to bone cement. Additionally, in spite of the recommendation of several authors to introduce a rejection criterion for specimens based on the size of defects found in the fracture surface, no data are available about the effect of porosity within the material on the KIc of bone cement. The aims of this study were to verify whether the KIc values calculated for bone cement using the two procedures are comparable and whether macroporosity within the tested samples affects the KIc value of bone cement, and, if so, to establish a rejection criterion for specimen selection. Samples of pure polymethyl methacrylate (PMMA) were tested by both procedures. Additionally, samples showing defects (macroporosity) of different sizes and located in different positions within the specimen were tested. The KIc value determined following the ASTM E399 procedure was 13 per cent lower than that calculated following the ASTM D5045 procedure. In the first series a lower data scatter was observed. Also, the presence of macroporosity on the fracture surface of the specimen affected the KIc value of bone cement. Therefore, the mechanical behaviour of samples was affected by defects within the material. Since it is possible to mould specimens without macroporosity, it seems recommendable to reject specimens with macroporosity on the fracture surface before calculating the KIc value of bone cement.

Bone Cements↗

Differences in proximal femur geometry distinguish vertebral from femoral neck fractures in osteoporotic women.

Bone mineral density (BMD) is generally used to predict the risk of fracture in osteoporotic subjects. However, femoral neck BMD and spine BMD have been reported not to be significantly different among patients with hip or vertebral fractures, suggesting that other risk factors are needed to determine the different fracture types. Proximal femur geometry (PFG) parameters, such as hip axis length (HAL), femoral neck-shaft angle (NSA) and femoral neck diameter (FND) have also been shown to predict the risk of hip fracture. These parameters are statistically different in spine fractures compared with both types of hip fractures (trochanteric and femoral neck) when considered together. We wanted to assess the difference in these parameters by comparing spine fractures with a homogeneous group of hip fractures, i.e. femoral neck fractures. 807 post-menopausal women were divided into three groups; those with vertebral fractures (182), those with femoral neck fractures (134) and a control group without fractures (491). Dual X-ray absorptiometry (DXA) scans of the spine and hip were carried out to measure BMD and define the PFG parameters of the hip. Data were statistically analysed. In agreement with other authors, we found that women with femoral neck fractures had longer HAL, wider FND and larger NSA than controls, whereas there were no statistically significant differences in PFG between women with spine fractures and controls. Logistic regression showed HAL and NSA could predict the risk of femoral neck but not vertebral fracture. These data indicate specificity of some PFG parameters for hip fracture risk.

Aged↗

CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning.

The present study is aimed to compare accuracy and the repeatability in planning total hip replacements with the conventional templates on radiographs to that attainable on the same clinical cases when using CT-based planning software. The sizes of the cementless components planned with new computer aided preoperative planning system called Hip-Op and with standard templates were compared to those effectively implanted. The study group intentionally included only difficult clinical cases. The most common aetiology was congenital dysplasia of hip (65.6%). The Hip-Op planning system allowed the surgeons to obtain a preoperative planning more accurate than with templates, especially for the socket. Assuming correct a size planned one calliper above or below that implanted the accuracy increased from 83% for the stem and 69% for the socket when using templates to 86% for the stem and 93% for the socket when using the Hip-Op system. The repeatability of the Hip-Op system was found comparable to that of the template procedure, which is much more familiar to the surgeons. Furthermore, the repeatability of the preoperative planning with the Hip-Op system was consistent between surgeons, independently from their major or minor experience. The study clearly shows the advantages of a three-dimensional computer-based preoperative planning over the traditional template planning, especially when deformed anatomies are involved. The surgical planning performed with the Hip-Op system is accurate and repeatable, especially for the socket and for less experienced surgeons.

Arthroplasty, Replacement, Hip↗

The muscle standardized femur: a step forward in the replication of numerical studies in biomechanics.

The standardized femur is the computer aided design (CAD) solid model of a synthetic human femur, commonly used in experiments in vitro, available in the public domain through the International Society of Biomechanics Finite Element Mesh Repository. Currently used by hundreds of researchers, it was made available to simplify the experimental cross-validation of numerical studies as well as their replication by other researchers. One aspect that the standardized femur left uncovered is the definition of muscles and ligaments. In particular, for a variety of simulations it would be extremely useful to map on to the femoral surface the insertion of the principal muscles. The aim of the present study was to create a new solid model, called the muscle standardized femur, where the femoral insertion of each muscle is mapped on to the surface of the femur. Published data on muscle insertion morphometry were registered to the model by applying an affine scaling defined on bone landmarks. Good agreement was found with another similar study in which only the insertion centres were defined. The new model will be made available in the public domain for no-profit uses. When combined with published data on the direction and intensity of muscular forces this model is expected to make a useful contribution to the steadily growing library of models and data sets made available to the biomechanical community.

Anatomy, Cross-Sectional↗

Mechanical strength of a femoral reconstruction in paediatric oncology: a finite element study.

In 1997 the proximal femur of a four-year-old child affected by a Ewing sarcoma was reconstructed using a massive bone allograft in conjunction with a vascularized fibula autograft. During the first three years of follow-up the reconstruction underwent important morphological changes. The aim of the present study was to evaluate the risk of fracture of the reconstructed proximal femur, once the physiological loads are restored, associated with a short, slow but unprotected level walk. Subject-specific finite element models of the operated femur, and of the intact contralateral one, were generated from a computed tomography exam, taken for routine clinical monitoring at month 33 of follow-up. The material properties were mapped on to the mesh and a loading condition comprising the hip joint reaction and the abductor muscle force was simulated. The risk of fracture was locally estimated, for the operated and intact femur, using the ratio between the bone tissue strength and the predicted Von Mises equivalent stress, taking into account the different behaviours of the bone tissue in tension or compression. The results showed that although the fibula grew dramatically during follow-up, the reconstructed femur had not recovered the whole mechanical strength of a normal femur. The reconstructed femoral neck seemed to be weaker than the contralateral one and hence at a higher fracture risk. However, no region reached the failure limit, so the model predicted no fracture of the femur if a short, slow but unprotected walk were allowed. The model predictions found an indirect clinical validation when the child was allowed to perform short unprotected walks and did not experience any fracture.

Bone Transplantation↗

Development and numerical validation of a finite element model of the muscle standardized femur.

The human femur is one of the parts of the musculo-skeletal system most frequently analysed by means of the finite element (FE) method. Most FE studies of the human femur are based on computed tomography data sets of a particular femur. Since the geometry of the chosen sample anatomy influences the computed results, direct comparison across various models is often difficult or impossible. The aim of the present work was to develop and validate a novel three-dimensional FE model of the human femur based on the muscle standardized femur (MuscleSF) geometry. In the new MuscleSF FE model, the femoral attachment of each muscle was meshed separately on the external bone surface. The model was tested under simple load configurations and the results showed good agreement with the converged solution of a former study. In the future, using the validated MuscleSF FE model for numerical studies of the human femur will provide the following benefits: (a) the numerical accuracy of the model is known; (b) muscle attachment areas are incorporated in the model, therefore physiological loading conditions can be easily defined; (c) analyses of the femur under physiological load cases will be replicable; (d) results based on different load configurations could be compared across various studies.

Compressive Strength↗