Search PubMed⌕ Search

PubMed · 782572

Chemically sensitive field-effect transistors.

Abstract

The present state of the art and trends in development of chemically sensitive field-effect transistors are reviewed. In the theoretical section, a brief description of principles, temperature sensitivity, stability and the question of a reference electrode are discussed. In the practical section some aspects of the design and recommendations for device evaluation procedures are given. The article concludes with the authors' view of future development, particularly with respect to biomedical applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Janata, S D Moss. 1976. Chemically sensitive field-effect transistors.. https://pubmed.ncbi.nlm.nih.gov/782572/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A pragmatic approach to structure based calculation of coupled proton and electron transfer in proteins.

The coupled motion of electrons and protons occurs in many proteins. Using appropriate tools for calculation, the three-dimensional protein structure can show how each protein modulates the observed electron and proton transfer reactions. Some of the assumptions and limitations involved in calculations that rely on continuum electrostatics to calculate the energy of charges in proteins are outlined. Approaches that mix molecular mechanics and continuum electrostatics are described. Three examples of the analysis of reactions in photosynthetic reaction centers are given: comparison of the electrochemistry of hemes in different sites; analysis of the role of the protein in stabilizing the early charge separated state in photosynthesis; and calculation of the proton uptake and protein motion coupled to the electron transfer from the primary (Q(A)) to secondary (Q(B)) quinone. Different mechanisms for stabilizing intra-protein charged cofactors are highlighted in each reaction.

Electrochemistry↗

Electrochemically modulated preconcentration and matrix elimination for organic analytes coupled on-line with electrospray mass spectrometry.

Demonstrated for the first time is the use of electrochemically modulated preconcentration and sample matrix elimination combined on-line with electrospray mass spectrometry (EMPM/ES-MS) for the enhanced analysis of organics by ES-MS. EMPM is similar to adsorptive stripping analysis. Accumulation of the targeted analytes at the working electrode of an on-line electrochemical flow cell is accomplished via a nonelectrolytic adsorption process that is controlled through the proper combination of the solvent system, the working electrode material, and applied potential. Once on the electrode, the analyte may be washed free of sample matrix components detrimental to mass spectrometric detection. The potential applied to the electrode during the detection step is chosen to release or strip the analytes unaltered back into the solvent stream for mass spectrometric detection rather than to oxidize or reduce them as would be the case for electrochemical detection. Thus, retention and elution of a target analyte with EMPM are controlled by switching the working electrode potential, rather than via a switch in mobile-phase composition, as is done in more traditional preconcentration and cleanup schemes used on-line with ES-MS. The proof-of-principle studies described here use the breast cancer drug tamoxifen and a metabolite, 4-hydroxytamoxifen, as the target analytes. A thin-layer, flow-by electrode cell with a glassy carbon working electrode is used as the preconcentration device. The nature of the working electrode, the solvent systems, and the electrode potentials necessary to accumulate and strip tamoxifen and 4-hydroxytamoxifen are discussed. Calibration curves were fitted using the Langmuir isotherm. Detection limits (DLs) using a 5.0 min preconcentration period with selected reaction monitoring for tamoxifen (m/z 372 --> 72) were bracketed as 0.010 nM < DL < 0.025 nM. The ability to simultaneously detect low nanomolar levels of both tamoxifen and 4-hydroxytamoxifen in pristine solution and 1/10 diluted urine is also demonstrated.

Electrochemistry↗

The effect of hexadecaprenyl diphosphate on phospholipid membranes.

In the present study we investigated phospholipid bilayer membranes and phospholipid vesicles made from dioleoylphosphatidylcholine (DOPC) or its mixture with the phosphate ester derivative of long-chain polyprenol (hexadecaprenyl diphosphate, C(80)-PP) by electrophysiological and transmission electron microscopy (TEM) techniques. The membrane conductance-temperature relationships and the membrane breakdown voltage have been measured for different mixtures of C(80)-PP/DOPC. The current-voltage characteristics, the membrane conductance, the activation energy of ion migration across the membrane and the membrane breakdown voltage were determined. Hexadecaprenyl diphosphate decreases the membrane conductance, increases the activation energy and the membrane breakdown voltage for the various values of C(80)-PP/DOPC mole ratio. The analysis of TEM micrographs shows several characteristic structures, which have been described. The data indicate that hexadecaprenyl diphosphate modulates the surface curvature of the membranes by the formation of aggregates in liquid-crystalline phospholipid membranes. The properties of modified membranes can result from the presence of the negative charges in the hydrophilic part of C(80)-PP molecules and can be modulated by the concentration of this compound in membranes. We suggest that the dynamics and conformation of hexadecaprenyl diphosphate in membranes depend on the transmembrane electrical potential.

Electrochemistry↗