Which primary total hip replacement?

Abstract

To assist surgeons to select a total hip replacement (THR) we present comparative information on all such implants on the market in the UK. We identified 62 different primary THRs, manufactured by 19 companies; half had been introduced in the last five years, and only 30% have any results published in peer-reviewed journals. The prices range from 250 pounds to 2000 pounds, and the two cheapest implants have the longest reported follow-up. The number of THR implants available in the UK, and presumably the rest of the world, is rapidly increasing, but there is little or no scientific evidence that the newer, more expensive, implants are better than established designs. Some will undoubtedly be worse. We believe that this situation is unsatisfactory and make recommendations for improvement, in particular that preference be given to implants with good results in published peer-reviewed long-term clinical trials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D W Murray, A J Carr, C J Bulstrode. 1995. Which primary total hip replacement?. https://pubmed.ncbi.nlm.nih.gov/7615593/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Characterization of visible dyes for four-decay fluorescence detection in DNA sequencing.

Dyes of several classes were investigated as candidates for use in a multiplex, four-decay fluorescence detection scheme for DNA sequencing. The dyes include nitrobenzofuran dyes, rhodamine dyes, fluorescein dyes, cyanine dyes, Nile Red, and BODIPY dyes. Based on the results of fluorescence spectral and lifetime studies, an initial set of four dyes was selected for further study: NBD-aminohexanoic acid (NBD-HA, r = 1.1 ns), tetramethyl-rhodamine, methyl ester (r = 2.2 ns), rhodamine green (r = 4.3 ns), and BODIPY 505/515 (r = 5.9 ns). Limits of lifetime detection of the four dyes were investigated, and lifetime resolution was demonstrated for mixtures of the free dyes in batch solution. Lifetime of dye-labeled DNA primers also were determined in batch solution and detected on-the-fly in capillary electrophoresis (CE). Conjugation of the dyes to DNA improved the resolution of their individual lifetimes in mixtures in batch measurements. When attached to the primer, tetramethyl-rhodamine exhibited biexponential decay with a dominant lifetime of 3.8 ns, making it unsuitable for four-decay sequencing. Contact with the CE gel lengthened the lifetime of NBD-HA-labeled primer from 1.3 to 2.1 ns but did not affect the lifetimes of the other dyes. Lifetime detectability of labeled primers at individual points along an electrophoretic peak in the attomole range.

Evaluation Studies as Topic