Search PubMed⌕ Search

Biomedical subjects

D W Murray

Publications and source records attributed to D W Murray.

At least 19 recordsLinked to original sources

No deterioration of kinematics and cruciate function 10 years after medial unicompartmental arthroplasty.

The mechanisms of failure for unicompartmental arthroplasty are poorly understood. There is some suggestion that long term ligament degeneration, particularly of the anterior cruciate ligament (ACL), may affect long term survivorship. This study evaluated whether the cruciate mechanism remained functional in the long term (10 years) following UKA. Two separate cohorts of patients who had undergone St Georg Sled medial compartmental arthroplasty had knee kinematics assessed using an established fluoroscopic technique. One group (early) was assessed at a mean of 46 months (3.8 years) since surgery, whilst the other (late) was assessed at a mean of 125 months (10.4) following surgery. No significant difference was found in the sagittal plane kinematics between the two groups or in comparison to the control normal knee. The results suggest that after fixed bearing UKA the cruciate mechanism remains intact over time and the ligaments continue to function similarly to those of the normal knee.

Aged↗

In vivo measurement of volumetric wear of a total knee replacement.

A new Roentgen Stereophotogrammetric Analysis (RSA) system is reported; it can measure penetration of the metallic femoral component of a Total Knee Replacement (TKR) prosthesis into the polyethylene bearing on the tibial component. This system was used to analyse a study group of six Anatomic Graduated Components (AGC) knee prostheses more than 6 years post-implantation, and to compare with a control group of six newly implanted AGC prostheses. The volumetric loss of polyethylene was estimated by imaging each prosthesis at a series of different knee flexion angles. The mean difference between the RSA measured polyethylene bearing thickness and the manufacturer's quoted values for the control group was -0.03 mm (SD 0.17). The estimated linear penetration at 6.4 years in this prosthesis was determined to be 0.1 mm/year. Volumetric wear was estimated to be 600-700 mm(3)/year at 6.4 years, equating to approximately 100 mm(3)/year. This does not appear to be clinically significant amount of wear as this prosthesis has excellent survival at 10 years.

Aged↗

A convex lateral tibial plateau for knee replacement.

Unicompartmental knee replacements have not performed as well in the lateral compartment as in the medial. This may be because the tibial components have flat or slightly concave surfaces which match the medial plateau but not the convex lateral plateau. The aim of this study was to find the optimal radius for a convex lateral tibial component. Twelve normal lateral tibial plateau were retrieved at knee replacement, and their surface contour in their mid sagittal plane was determined. The optimal circle was fitted and its radius measured. A series of different shaped tibial components were superimposed. From published information about the position of the femoral condyle relative to the tibia in different degrees of flexion, the flexion gap at these angles was determined. The average radius of the lateral tibial plateau was 40 mm. However, as the surface was polyradial it was not clear if this average radius would be optimal. In full flexion, a flat tibial plateau distracted the knee by 8 mm (p<0.001). A 75 mm radius spherical tibial plateau did not alter the knee kinematics significantly and gave rise to a change in joint distraction of 1.5 mm. Spherical tibial plateau of 50 mm and 25 mm radii significantly altered knee kinematics (p<0.001) and resulted in changes in distraction of 3 mm and 4 mm respectively. The optimal shape for a unicompartmental lateral tibial plateau is likely to be a spherical dome with radius of about 75 mm. The incorporation of this shape in the lateral side of a total knee replacement might improve its flexion.

Femur↗

RSA-measured inducible micromotion and interface modeling with finite element methods.

Osteolysis is the main cause of aseptic loosening and stem failure. The mechanism that leads to osteolysis is poorly understood; pressure generation caused by reversible stem micromotion may play an important role. We aimed to determine whether dynamically inducible micromotion occurs in vivo at the prosthesis-cement interface and to use these data to develop and confirm a finite element representation of this interface. Dynamically inducible micromotion was measured using radiostereometric analysis in 21 hips implanted with an Exeter stem, at 3 months and 12 months postoperatively, by changing loading from double-leg stance to single-leg stance. Dynamically inducible micromotion occurred at 3 and 12 months; similar micromotion was observed at both time points. At 3 months the head of the stem was displaced posteriorly (0.10 +/- 0.16 mm) and inferiorly (0.08 +/- 0.12 mm) on loading. A Coulomb friction nonbonded representation of the stem-cement interface was used to fit the clinically measured dynamically inducible micromotion. The final finite element model predicted gap opening and closing between the implant and the mantle. This may be a mechanism for generating pressure and distributing wear debris, which are believed to important contributors to failure.

Aged↗

The influence of surgical approach on cemented stem stability: an RSA study.

UNLABELLED: The surgical approach used is an important aspect of hip arthroplasty and will have an effect on the loading of the implant. Our goal was to establish whether there was a difference in early stem migration between the posterior and the lateral surgical approaches. The migration patterns of 45 Exeter stems in 45 patients were measured using radiostereometric analysis during a 2-year period; 19 of the stems were implanted using the posterior approach and 26 were implanted using the lateral approach. From postoperative radiostereometric measurements it was established that there was no difference in initial stem position between the two approaches. The posterior approach group had greater internal rotation of the stem, approximately 2 degrees during the first 2 years. The lateral group had almost 1/2 this amount of internal rotation. Overall stem subsidence was similar between the groups. These differences suggest that the lateral approach may give a survival advantage, especially for less rotationally stable stem designs and suboptimal cementing technique. The posterior approach gives rise to greater degree of internal rotation during the first 2 years. LEVEL OF EVIDENCE: Therapeutic Level II. See the Guidelines for Authors for a complete description of levels of evidence.

Aged↗

The Oxford medial unicompartmental knee replacement using a minimally-invasive approach.

This prospective study describes the complications and survival of the first 688 Phase 3 Oxford medial unicompartmental knee replacements implanted using a minimally-invasive technique by two surgeons and followed up independently. None was lost to follow-up. We had carried out 132 of the procedures more than five years ago. The clinical assessment of 101 of these which were available for review at five years is also presented. Nine of the 688 knees were revised: four for infection, three for dislocation of the bearing and two for unexplained pain. A further seven knees (1%) required other procedures: four had a manipulation under anaesthesia, two an arthroscopy and one a debridement for superficial infection. The survival rate at seven years was 97.3% (95% confidence interval 5.3). At five years, 96% of the patients had a good or excellent American Knee Society score, the mean Oxford knee score was 39 and the mean flexion was 133 degrees. This study demonstrates that the minimally-invasive Oxford unicompartmental knee replacement is a reliable and effective procedure.

Adult↗

Simultaneous in vitro measurement of patellofemoral kinematics and forces following Oxford medial unicompartmental knee replacement.

The Oxford medial unicompartmental knee replacement was designed to reproduce normal mobility and forces in the knee, but its detailed effect on the patellofemoral joint has not been studied previously. We have examined the effect on patellofemoral mechanics of the knee by simultaneously measuring patellofemoral kinematics and forces in 11 cadaver knee specimens in a supine leg-extension rig. Comparison was made between the intact normal knee and sequential unicompartmental and total knee replacement. Following medial mobile-bearing unicompartmental replacement in 11 knees, patellofemoral kinematics and forces did not change significantly from those in the intact knee across any measured parameter. In contrast, following posterior cruciate ligament retaining total knee replacement in eight knees, there were significant changes in patellofemoral movement and forces. The Oxford device appears to produce near-normal patellofemoral mechanics, which may partly explain the low incidence of complications with the extensor mechanism associated with clinical use.

Arthroplasty, Replacement, Knee↗

The premature failure of the Charnley Elite-Plus stem: a confirmation of RSA predictions.

We performed a clinical and radiological study to determine the rate of failure of the Charnley Elite-Plus femoral component. Our aim was to confirm or refute the predictions of a previous roentgen stereophotogrammetric analysis study in which 20% of the Charnley Elite-Plus stems had shown rapid posterior head migration. It was predicted that this device would have a high early rate of failure.We examined 118 patients at a mean of nine years after hip replacement, including the 19 patients from the original roentgen stereophotogrammetric study. The number of revision procedures was recorded and clinical and radiological examinations were performed. The rate of survival of the femoral stems at ten years was 83% when revision alone was considered to be a failure. It decreased to 59% when a radiologically loose stem was also considered to be a failure. All the patients previously shown in the roentgen stereophotogrammetric study to have high posterior head migration went on to failure. There was a highly significant difference (p = 0.002) in posterior head migration measured at two years after operation between failed and non-failed femoral stems, but there was no significant difference in subsidence between these two groups. Our study has shown that the Charnley Elite-Plus femoral component has an unacceptably high rate of failure. It confirms that early evaluation of new components is important and that roentgen stereophotogrammetric is a good tool for this. Our findings have also shown that rapid posterior head migration is predictive of premature loosening and a better predictor than subsidence.

Adult↗

Combined anterior cruciate reconstruction and Oxford unicompartmental knee arthroplasty.

The options for treatment of the young active patient with isolated symptomatic osteoarthritis of the medial compartment and pre-existing deficiency of the anterior cruciate ligament are limited. The potential longevity of the implant and levels of activity of the patient may preclude total knee replacement, and tibial osteotomy and unicompartmental knee arthroplasty are unreliable because of the ligamentous instability. Unicompartmental knee arthroplasties tend to fail because of wear or tibial loosening resulting from eccentric loading. Therefore, we combined reconstruction of the anterior cruciate ligament with unicompartmental arthroplasty of the knee in 15 patients (ACLR group), and matched them with 15 patients who had undergone Oxford unicompartmental knee arthroplasty with an intact anterior cruciate ligament (ACLI group). The clinical and radiological data at a minimum of 2.5 years were compared for both groups. The groups were well matched for age, gender and length of follow-up and had no significant differences in their pre-operative scores. At the last follow-up, the mean outcome scores for both the ACLR and ACLI groups were high (Oxford knee scores of 46 (37 to 48) and 43 (38 to 46), respectively, objective Knee Society scores of 99 (95 to 100) and 94 (82 to 100), and functional Knee Society scores of 96 and 96 (both 85 to 100). One patient in the ACLR group needed revision to a total knee replacement because of infection. No patient in either group had radiological evidence of component loosening. The radiological study showed no difference in the pattern of tibial loading between the groups. The short-term clinical results of combined anterior cruciate ligament reconstruction and unicompartmental knee arthroplasty are excellent. The previous shortcomings of unicompartmental knee arthroplasty in the presence of deficiency of the anterior cruciate ligament appear to have been addressed with the combined procedure. This operation seems to be a viable treatment option for young active patients with symptomatic arthritis of the medial compartment, in whom the anterior cruciate ligament has been ruptured.

Adult↗

In vivo kinematics of the ACL-deficient limb during running and cutting.

Anterior cruciate ligament-deficient (ACLD) knee kinematics during high-demand activities are poorly understood. We have devised a new method, using gait analysis, to more accurately assess 3-D in vivo kinematics of the knee. This has enabled us to report on how knee kinematics are altered after ACL rupture, during running and cutting. Fifteen unilaterally ACLD subjects were assessed using a 12-camera 100 Hz VICON motion analysis system. Simultaneous electromyographical (EMG) recordings were used to assess the role of the sensorimotor system in knee joint stability. All subjects were able to perform demanding cutting activities without experiencing symptoms of instability. We found that running produces fundamentally different kinematic patterns to those seen during walking. Tibiofemoral translation in the anteroposterior plane is controlled to within normal limits. Conversely, coronal translation and rotation are poorly controlled. We found that the injured leg was maintained in greater extension during the stance phase of all running activities studied and that the quadriceps muscle was active for longer during this period. We believe that low-demand activities, such as walking, do not reproduce kinematics relevant to ACLD instability and that future investigations into functional instability in the ACLD knee should focus on coronal and rotational displacements.

Adolescent↗

[Is computer navigation a useful tool in unicompartmental knee arthroplasty? A pilot cadaver study].

We conducted this pilot cadaver study to investigate whether the use of a navigation system during minimally invasive unicompartmental knee arthroplasty leads to more consistent results than the conventional hand-guided technique. We describe the accuracy of implant positioning in using standard instrumentation and computer navigation. Radiographic assessment showed that accurate component placement was achieved using both methods. These results were not statistically significant. The computer navigated femoral component placement without intramedullary (IM) rod was as accurate as the conventional method with IM rod. The study showed that computer navigation can produce accurate results even without an intramedullary rod. Image guidance can maintain the accuracy of the standard instrumentation and enhance 3D vision and the intraoperative orientation of the surgeon.

Arthroplasty, Replacement, Knee↗

A novel method for in vivo knee prosthesis wear measurement.

Wear remains an important cause of failure in knee replacement. Of the current methods of early performance assessment or prediction, simulators have been un-physiological, single X-ray film analyses remain limited by accuracy and retrieval and survival methods have a prohibitive time scale. An accurate method is needed to allow a timely assessment of polyethylene component wear in vivo, when a new design is introduced, in order to predict likely outcome. We present a new method for measuring wear in vivo that we believe will allow this prediction of long-term wear. X-ray film pairs were taken of implanted prosthetic metal components. When the X-ray system was calibrated, projections of the appropriate Computer Aided Design (CAD) model could be matched to the shapes on the scanned X-ray films to find component positions. Interpenetration of the metal femoral component into the polyethylene component could then be established and represents our estimate of "wear". This method was used to measure in vivo prosthesis wear to an accuracy of 0.11 mm.

Arthroplasty, Replacement, Knee↗

In-vivo sagittal plane knee kinematics: ACL intact, deficient and reconstructed knees.

Sagittal plane video fluoroscopy was used to analyse the bilateral knee kinematics of patients with unilateral ACL deficiency (ACLD) before, and 4 months after, hamstrings graft ACL reconstruction. Kinematics were studied during weight resisted knee extension, passive knee extension, and a step up. Thigh EMG records were also obtained from five subjects. In addition, six uninjured control subjects were analysed to establish normal kinematics. Kinematics were analysed by calculating the angle between the long axis of the tibia and the patella tendon through the range of knee flexion. Shear forces were calculated using a model of knee extension and force plate data. A maximum anterior TT of 7.3 (S.D. 2.1) mm was recorded in ACL intact (ACLI) knees during the weightbearing activity. Hamstrings activity was able to control ATT in the ACLD tibia to within the normal range of translation of the ACLI knee. Despite clinical improvements, ATT increased postoperatively in the reconstructed knees to 11.6 (S.D. 3.8) mm (P<0.048). The findings suggest that the ACL has only a minor role in the control of ATT during activity, and that the extent of ATT is more closely related to the level of quadriceps-generated shear force. A reduction in hamstrings force is proposed as the most likely cause for increased ATT post reconstruction. These findings have implications for the development of ACL rehabilitation regimes, and also may modify graft choice and the surgical aims of the procedure.

Adult↗

Efficacy of an accelerated recovery protocol for Oxford unicompartmental knee arthroplasty--a randomised controlled trial.

Unicompartmental knee arthroplasty (UKA) is appropriate for one in four patients with osteoarthritic knees. This study was performed to compare the safety, effectiveness and economic viability of a new accelerated protocol with current standard care in a state healthcare system. A single blind RCT design was used. Eligible patients were screened for NSAID tolerance, social circumstances and geographical location before allocation to an accelerated recovery group (A) or standard care group (S). Primary outcome was the Oxford Knee Assessment at 6 months post operation, compared using independent Mann-Whitney U-tests. A simple difference in costs incurred was calculated. The study power was sufficient to avoid type 2 errors. Forty-one patients were included. The average stay for Group A was 1.5 days. Group S averaged 4.3 days. No significant difference in outcomes was found between groups. The new protocol achieved cost savings of 27% and significantly reduced hospital bed occupancy. In addition, patient satisfaction was assessed as greater with the accelerated discharge than with the routine discharge time. The strict inclusion criteria meant that 75% of eligible patients were excluded. However, a large percentage of these were due to the distances patients lived from the hospital.

Arthroplasty, Replacement, Knee↗

Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties.

We did an in vivo fluoroscopic study comparing the sagittal plane kinematics of mobile-bearing and fixed-bearing total knee arthroplasties in a unique group of patients. These patients were part of a larger bilateral randomized controlled outcome trial with each patient having received both types of total knee arthroplasties. Invited patients did three exercises with each of their different knee replacements; extension against gravity, flexion against gravity, and a step-up. These exercises were recorded using video fluoroscopy, and a series of still digital images over the flexion range were retrieved. The relationship of patella tendon angle to knee flexion angle for each patient was derived. The patella tendon angle to knee flexion angle of the mobile-bearing knee behaved in a linear manner more closely replicating the normal knee, whereas the fixed-bearing knee behaved in a nonlinear, more variable manner. This pattern of results was similar for all three exercises with each patient having one knee replacement that behaved differently in the sagittal plane when compared with their other knee replacement. These kinematic differences may explain the clinical differences observed in the randomized controlled trials that compared these two total knee arthroplasties.

Adult↗

Oxford medial unicompartmental knee arthroplasty in patients younger and older than 60 years of age.

We present a comparison of the results of the Oxford unicompartmental knee arthroplasty in patients younger and older than 60 years of age. The ten-year all-cause survival of the < 60 years of age group (52) was 91% (95% confidence interval (CI) 12), while in the > or = 60 years of age group (512), the figure was 96% (95% CI 3). For the younger group, the mean Hospital for Special Surgery score at ten-year follow-up (n = 21) was 94 of 100, compared with a mean of 86 of 100 for the older group (n = 135). The results show that the Oxford unicompartmental arthroplasty can achieve ten-year results that are comparable to total knee arthroplasty in patients < 60 years of age. We conclude that for patients aged over 50, age should not be considered a contraindication for this procedure.

Adult↗

Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty.

Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the in vivo ten-year linear wear of the device, using a roentgenstereophotogrammetric technique. In this in vivo study, seven medial Oxford unicompartmental prostheses, which had been implanted ten years previously were studied. Stereo pairs of radiographs were acquired for each patient and the films were analysed using a roentgen stereophotogrammetric analysis calibration and a computer-aided design model silhouette-fitting technique. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. In addition, eight control patients were examined less than three weeks post-insertion of an Oxford prosthesis, where no wear would be expected. The control group showed no measured wear and suggested a system accuracy of 0.1 mm. At ten years, the mean linear wear rate was 0.02 mm/year. The results from this in vivo study confirm that the device has low ten-year linear wear in clinical practice. This may offer the device a survival advantage in the long term.

Adult↗

The effect of hip resurfacing on oxygen concentration in the femoral head.

We inserted an electrode up the femoral neck into the femoral head of ten patients undergoing a metal-on-metal hip resurfacing arthroplasty through a posterior surgical approach and measured the oxygen concentration during the operation. In every patient the blood flow was compromised during surgery, but the extent varied. In three patients, the oxygen concentration was zero at the end of the procedure. The surgical approach caused a mean 60% drop (p < 0.005) in oxygen concentration while component insertion led to a further 20% drop (p < 0.04). The oxygen concentration did not improve significantly on wound closure. This study demonstrates that during hip resurfacing arthroplasty, patients experience some compromise to their femoral head blood supply and some have complete disruption.

Adult↗