Search PubMedSearch

PubMed · 7268627

Interobserver variability in single-plane aortography.

Abstract

Arteriography is regarded as the objective method for evaluation of arterial disease and is commonly used as the reference for the assessment of the accuracy of noninvasive diagnostic methods. Because no data are available supporting its reliability, a study regarding the interobserver variability of single-plane arteriography was done. Twenty-one translumbar aortograms were read by 11 surgeons and radiologists, and the results were analyzed with a statistical method which takes into account agreement by chance. It was found that interobserver agreement concerning the profunda bifurcation was only marginally more than that provided by chance. Occlusions were well recognized by the 11 observers, but the interobserver agreement on the degree of arterial stenosis was poor.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H B Slot, L Strijbosch, J M Greep. 1981. Interobserver variability in single-plane aortography.. https://pubmed.ncbi.nlm.nih.gov/7268627/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New technique using temporary balloon occlusion for transcatheter closure of patent ductus arteriosus with Gianturco coils.

We describe our early experience with a new technique involving temporary balloon occlusion for transcatheter closure of patent ductus arteriosus (PDA) using single or multiple Gianturco coils. Coil occlusion was attempted in 21 patients of median age 3 (range 1-11) years, and angiographic PDA diameter 3.0 mm +/- 0.87 mm. The inflated balloon of a pulmonary wedge pressure catheter over a transductal wire was used to mechanically hold the first extruded loop of the coil at the pulmonary end of the duct. If a residual shunt persisted after the delivery of the first coil, additional coils were delivered with or without the balloon support. One to nine coils (median 2) of different sizes varying between 3-12 mm diameter and 4-15 cm length were used. Immediate angiographic occlusion rate was 47.6%. However color Doppler (CD) at 24 hours and at 6 weeks revealed complete closure in 66.6% and 80.9%, respectively. Blood transfusion was required in 2 (9.5%) patients. Three out of 56 coils (5.4%) embolized during deployment. The use of balloon occlusion is effective and safe in the treatment of ducti up to 4.7 mm. Residual shunts lend to occlude with time.

Aortography

[Chronic mesenteric ischemia--surgical therapy in 3 level occlusion].

A 57-year-old patient with general arteriosclerosis and end-stage renal failure was found to be suffering from occlusion of the mesenteric arteries. The symptoms were rapidly progressive. The aortogram showed that nutrition of the whole intestine took place via a collateral vessel that originated at both internal iliac arteries. Revascularization of the superior mesenteric artery with interposition of Gore-Tex prosthesis and transposition to the aorta were performed. The postoperative course was uncomplicated, but prolonged due to the accompanying diseases. In conclusion, single-vessel revascularization for chronic intestinal ischemia is a safe and sufficient procedure. Interpositioning of a graft and transposition to the aorta have the advantages of infrarenal access with an antegrade blood flow and no kinking of the prosthesis.

Aortography

Early implantation of multiple spring coils for severe haemolysis after incomplete transcatheter occlusion of persistent arterial duct.

An 18 month old girl with an angiographically measured ductus of 4.5 mm underwent transcatheter occlusion of the persistent arterial duct with a 17 mm Rashkind umbrella and an occluding spring coil. Severe intravascular haemolysis developed 20 hours later. Significant residual ductal leakage was noted and the residual duct measured 6 mm. Previous underestimation might have been related to ductal spasm as a catheter was placed across the duct before angiography. The haemolysis was abolished within 48 hours by a previously unreported approach of antegrade transcatheter closure of the residual duct by multiple spring coils.

Aortography