Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Aortography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Diagnosis of abdominal lesions. The use of intravenous aortography, nephrotomography and retrograde aortography.

New and safe methods of investigating the kidney by x-ray visualization of its circulation are now available. This can be done either by injecting large amounts of contrast material through a vein and then taking multiple x-ray exposures of the kidneys, or by injecting the contrast material backward into the aorta to the level of the renal arteries. Another method of x-ray examination now available is taking body section films of the kidneys when the contrast medium is in the kidney substance. This makes the kidney outline extremely sharp and allows more precise diagnosis.

Abdomen↗

Use of computed tomographic scanning and aortography in the diagnosis of acute dissection of the thoracic aorta.

Before the introduction of computed tomographic (CT) scanning, aortography was the investigation of choice for acute aortic dissection. Between 1978 and 1982, 24 patients were referred to the Brompton Hospital with suspected acute thoracic aortic dissection; all had aortography with diagnosis confirmed at surgery (n = 12) or necropsy (n = 2) or supported by clinical outcome (n = 8). One patient in whom aortography was negative had type B dissection at necropsy and another patient was lost to follow up. CT scanning became available in this unit in 1983 and between 1983 and 1987 was used as the only imaging investigation in 32 patients with suspected acute dissection of the thoracic aorta while in a further 22 patients aortography was used alone. Results were confirmed at surgery (n = 18), necropsy (n = 3), or supported by clinical outcome (n = 31). Two patients were lost to follow up. In an additional 16 patients both aortography and CT scanning were performed with concordant findings in 10. In six in whom the results were discordant, aortography was normal in three in whom subsequent CT scanning showed type B dissection and CT scanning was normal in three patients in whom aortography showed type A dissection. Both CT scanning and aortography are reliable techniques for assessment of suspected acute dissection of the thoracic aorta. Both techniques misdiagnose occasionally and the frequency of misdiagnosis will be minimised by performing both investigations in patients where the level of clinical suspicion is high and the initial investigation negative. CT scanning tends to miss type A dissection and in view of the success of surgery in this condition this failing has the more serious clinical consequences.

Adult↗

Correlation between the measurement of transverse diameter in the proximal neck on computed tomography and on aortography before endovascular treatment of infrarenal aortic aneurysm.

The aim of this study was to determine the correlation between the measurement of transverse diameter of the proximal neck on computed tomographic angiography (CTA) and graduated catheter aortography in patients who are candidates for endovascular graft placement in order to replace, if both measurements are equivalent, aortography for CTA alone. Preoperative dual-slice CTA and graduated catheter aortography were performed in 35 consecutive patients with infrarenal aortic aneurysm within 10 days. Transverse proximal neck diameters were measured on a true axial section on CTA reconstructions and on aortographic images, always 6 mm distal from the most inferior main renal artery. Mean, median, and standard deviation were obtained and the measurements correlated for each patient using Pearson's correlation and linear regression analysis. A significant difference in proximal neck transverse diameter measurements was found between graduated catheter aortography and CTA in all cases. CTA values were a mean of 1.74 mm higher than aortography values. Pearson's correlation indicates a strong correlation between both techniques, and a regression equation determines the predictive value of aortography on the basis of CTA values. Estimation of the transverse diameter of the proximal neck on aortography on the basis of that obtained on CTA allows us to affirm that CTA could be used as the sole method for the preoperative selection of appropriate endograft size in patients with infrarenal aortic aneurysm.

Angioplasty, Balloon↗

Indications for aortography in blunt thoracic trauma: a reassessment.

The indications for aortography in patients sustaining blunt chest trauma have increased as the number of radiographic and clinical findings associated with traumatic rupture of the thoracic aorta (TRA) proliferate. No studies, however, have demonstrated whether these findings are useful in selecting patients for aortography. In order to determine the predictive value of reported associations in TRA, the presence or absence of nine radiographic and nine clinical findings associated with TRA were tabulated and tested for correlation with the results of aortography in 173 consecutive patients who underwent arch aortography from 1975 to 1980 to rule out TRA following blunt trauma. Mediastinal widening was the most reliable indicator of TRA. All patients less than 65 years old with TRA presented with mediastinal widening. In patients under 65, the reliability of mediastinal widening to predict TRA was not enhanced by any other clinical or radiographic finding studied. On the other hand, only two of six TRA's in patients over 65 had mediastinal widening. Only in this group over 65 did other publicized indications for aortography, including pulmonary contusions or multiple rib fractures including ribs 1 and 2, have any association singly or in combination with TRA. We conclude that all trauma victims who have a widened mediastinum should undergo aortography. Other reported associations by themselves are not absolute indications for aortography except in patients 65 years old or older.

Adolescent↗

Spiral CT angiography versus aortography in the assessment of aortoiliac length in patients undergoing endovascular abdominal aortic aneurysm repair.

PURPOSE: To compare measurements of aortoiliac length obtained with spiral computed tomographic angiography (CTA) and aortography in patients undergoing endovascular aneurysm repair. METHODS: The distances from the lower-most renal artery to the aortic bifurcation and from the aortic bifurcation to the common iliac artery (CIA) bifurcation were measured using both CTA and aortography in 108 patients with abdominal aortic aneurysms. RESULTS: The level of agreement between CTA and aortography was high, with 69% of aortic and 76% of iliac measurements within 1 cm and > 90% within 2 cm of each other. Mean differences were -0.35 +/- 1.20 cm and 0.25 +/- 1.10 cm, respectively, for aortic and iliac lengths. Aortography overestimated renal artery to aortic bifurcation length in comparison to CTA (p = 0.003), particularly in patients with large aneurysms (> 6.5 cm) and lumen diameters > 4.5 cm (p < 0.0001). Measurements of CIA length were shorter by aortography than CTA (p = 0.02). CONCLUSIONS: There is a high level of agreement between CTA and aortography in the measurement of aortoiliac length, but aortography overestimates renal artery to aortic bifurcation length in patients with large-diameter aneurysms and wide aneurysm lumens. CTA is sufficiently accurate in the majority of cases to be used as the sole basis for the construction of endovascular grafts.

Aged↗

Transmediastinal gunshot wounds. A reconsideration of the role of aortography.

OBJECTIVE: To evaluate the contribution of aortography in the management of stable patients with transmediastinal gunshot wounds. DESIGN: Retrospective review of clinical records. SETTING: Level I urban trauma center. PATIENTS: Forty-three patients with aortic or esophageal gunshot injuries. INTERVENTIONS: Patients who were stable after initial resuscitation underwent aortography followed by esophagography. MAIN OUTCOME MEASURES: Hemodynamic status on admission, time devoted to diagnostic workup, surgical (or autopsy) findings, morbidity, and mortality. RESULTS: There were 24 esophageal injuries and 20 aortic injuries. Patients with aortic injuries were less often stable for aortography (10% vs 42%; P = .02), and fewer of them survived (15% vs 58%; P = .01). In no patient was the aortic injury initially detected by aortography. Stable patients with esophageal injuries experienced an average 11-hour interval between injury and surgery (nearly 3 hours attributable to aortography). CONCLUSION: Esophageal evaluation should precede aortography in the workup of stable patients with transmediastinal gunshot wounds.

Adolescent↗

Comparative diagnostic value of transesophageal echocardiography and retrograde aortography in the evaluation of thoracic aortic dissection.

The aim of this study was to assess the comparative diagnostic value of transesophageal echocardiography (TEE) and retrograde aortography for morphologic evaluation and anatomic mapping of aortic dissection. Seventy patients (aged 18 to 79 years) were prospectively evaluated with both techniques for suspected aortic dissection. In 64 patients, findings on aortography and TEE could be validated against intraoperative (n = 53) and postmortem (n = 11) findings. Examination time was significantly shorter for TEE (9 +/- 6 vs 48 +/- 25 minutes; p < 0.001). For the detection of aortic dissection, aortography showed lower sensitivity (87.5% vs 97.5%) and negative predictive value (85.3% vs 96.7%; both trends did not reach statistical significance) due mostly to the inability to identify noncommunicating dissection (dissection without intimal tears). For the epiphenomena of aortic dissection, aortography was significantly more accurate (97.2% vs 78%; p < 0.05) in assessing the site of entry, and TEE was more accurate in identifying thrombus formation (90% vs 65%; p < 0.05). There was no significant difference between aortography and TEE with regard to assessing secondary tears, aortic regurgitation, coronary dissection, and extension of the dissection. Thus, both TEE and aortography offer detailed anatomic mapping for guided surgical interventions. In elective patients, integration of both techniques seems the best approach; in unstable patients, TEE may be preferential because it is less invasive, requires no contrast injection, and provides accurate diagnosis in a short time at the bedside.

Adult↗

Frequency and explanation of false negative diagnosis of aortic dissection by aortography and transesophageal echocardiography.

OBJECTIVES: This study was designed to define the frequency and explanation of false negative diagnosis of aortic dissection by aortography and transesophageal echocardiography. BACKGROUND: Aortography and transesophageal echocardiography have been widely utilized to diagnose aortic dissection. Previous reports have not fully addressed the reasons why these studies yield false negative results in a large number of patients with aortic dissection. METHODS: Sixty-five consecutive patients with aortic dissection underwent aortography and transesophageal echocardiography. Diagnosis of aortic dissection was confirmed at operation or by computed tomography in all patients. RESULTS: Biplane transesophageal echocardiograms yielded false negative results in two patients (sensitivity 97% [63 of 65]). Both patients had well localized DeBakey type II aortic dissection. The diagnosis was probably missed because of image interference from the air-filled trachea and mainstem bronchi. In both patients, the dissection was readily identified by aortography. Aortograms yielded false negative results in 15 patients (sensitivity 77% [50 of 65]); the aortic dissection was type I in 7 patients, type II in 1 and type III in 7. The dissection in all 15 patients was readily identified by transesophageal echocardiography. The missed diagnosis was probably due to a completely thrombosed false lumen or intramural hematoma with noncommunicating dissection in 13 patients and to a large ascending aortic aneurysm with nearly equal flow on both sides of the intimal flap in 2. In no patient was the diagnosis missed by both aortography and transesophageal echocardiography. CONCLUSION: Transesophageal echocardiography is an excellent screening tool for aortic dissection. However, it may miss small type II aortic dissections localized to the upper portion of the ascending aorta because of image interference from the air-filled trachea. An intramural hematoma cannot be easily visualized by aortography, and this lesion is the principal reason for false negative aortographic findings.

Adult↗

What imaging studies are necessary for abdominal aortic endograft sizing? A prospective blinded study using conventional computed tomography, aortography, and three-dimensional computed tomography.

OBJECTIVE: Preoperative imaging modalities for endovascular abdominal aortic aneurysm repair (EVAR) include conventional computed tomography (CT), aortography with a marking catheter, and three-dimensional computed tomography (3D CT). Although each technique has advantages, to date no study has compared in a prospective manner the reproducibility of measurements and impact on graft selection of all three modalities. The objective of this study was to determine the most useful imaging studies in planning EVAR. METHODS: Twenty patients being considered for EVAR were enrolled prospectively to undergo a conventional CT scan and aortography. The CT scans were then reconstructed into 3D images using Preview Treatment Planning Software (Medical Media Systems, West Lebanon, NH). Four measurements of diameter and six of length were made from each modality in determining the proper graft for EVAR. RESULTS: Measurements from all three modalities were reproducible with intraobserver correlation coefficients of 0.79 to 1.0 for aortography, 0.87 to 1.0 for CT, and 0.96 to 1.0 for 3D CT. Measurements between observers were also similar from each modality; interobserver correlations were 0.70 to 0.97 for aortography, 0.76 to 0.97 for CT, and 0.73 to 0.99 for 3D CT. Significant differences ( P < .01) in diameter measurements were noted at D2 with aortography compared with 3D CT, whereas differences in length measurements were found between CT and 3D CT at L4 (nonaneurysmal right iliac) ( P < .01). The correlation between CT and 3D CT for most length measurements was acceptable (0.63 to 1.0). Aortography for diameters correlated poorly (0.35 to 0.67) with 3D CT. When the endograft selected by aortography/CT or 3D CT alone was compared with the actual endograft used, there was agreement in 11 of 11 patients when adjusted for +/- one size in diameter or length. CONCLUSION: Reproducible and comparable measures of diameter and length can be obtained by each of three imaging modalities available for endograft sizing. As a single imaging modality, 3D CT appears to have the best correlation for both diameters and lengths; however, the difference is not sufficient enough to alter endograft selection. Three-dimensional CT may be reserved for challenging aortic anatomy where small differences in measurements would affect patient or graft selection for EVAR.

Aged↗