Search PubMed⌕ Search

PubMed · 6342377

Insulin binding to plastic bags: a methodologic study.

Abstract

A radiotracer method to assess insulin binding to commercially available plastic peritoneal dialysis solution containers was developed. A peritoneal dialysis bag (bag 2) was emptied and attached to another full bag (bag 1) of the same kind. In the syringe-to-bag method, bag 1 was symmetrically injected through the bag wall with four syringes containing dialysis solution and radioactive insulin, with or without regular insulin. The radioactivity in each syringe was measured with a gamma counter before injection, and all of the samples were counted afterwards directly in the syringes. Using a bag-to-bag transfer method, bag 1 was agitated, eight samples were taken from different parts through the wall, and then the contents were transferred to bag 2. Bag 2 was then agitated and eight samples were taken and counted. In the bag-pieces method, pieces of bag wall were cut and the radioactivity on the walls was measured to determine the amount of binding. The syringe-to-bag method gave negative results, severely underestimating the amount of insulin binding. The bag-to-bag transfer method yielded positive results in all instances. Increasing the amounts of regular insulin had no demonstrable impact on percent of binding. When the bag-to-bag method was compared with the bag-pieces method, it gave only slightly higher values; however, the bag-to-bag method was considered more reliable because the counting can be controlled more effectively. A 15-minute delay in sampling was not found to influence insulin binding. A reliable method of assessing insulin binding must be based on the following two principles: (1) The transfer of samples to intermediate containers should be avoided, and (2) radiotracer concentrations in the samples should be similar.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Z J Twardowski, K D Nolph, T J McGary, H L Moore, P Collin, R K Ausman, W S Slimack. 1983. Insulin binding to plastic bags: a methodologic study.. https://pubmed.ncbi.nlm.nih.gov/6342377/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrodialysis with bipolar membranes for sustainable development.

Electrodialysis with bipolar membranes (EDBM) is a kind of technology that integrates solvent and salt dissociation. It can realize salt conversion without second salt pollution or provide H+ and OH-/alkoxide ions in situ without salt introduction. Thus, it inherently possesses economical and environmental benefits. Moreover, its technological compatibility gives rise to new functions when it couples with other technologies, such as complexion, ion exchange, extraction, and adsorption. In view of the above peculiarities, EDBM has found many interesting applications in chemistry, food processing, biochemical industries, and environmental protection. However, its development has been restricted by such factors as lack of recognition of its contribution to industrial ecology, high membrane cost, insufficient research investment, and scarce operation experience. This paper compiles an introduction to this technology from the perspective of industrial ecology and conducts an extensive examination into EDBM applications. Its purpose is to gather synergic strength from academia, industry, and government to perfect EDBM for sustainable development.

Dialysis↗

Comparative study on the regeneration of flue-gas desulfurizing agents by using conventional electrodialysis (ED) and bipolar membrane electrodialysis (BMED).

Piperazine is an ideal desulfurizing agent but the heat-stable salts formed in desulfurization have caused secondary pollution and waste of resources. In the previous paper, a method was reported to regenerate piperazine by using BMED. To find the variety of that regeneration process, we performed experiments on the regeneration of piperazine by using ED. In comparison, ED has higher piperazine yield and current efficiency, and much lower voltage drop and energy consumption. However, its process cost is higher than that of BMED due to an extra expenditure for the base and its tank and pumps. The process cost is estimated to be 0.96 dollar/kg Pz for BMED and 1.14 dollar/kg Pz for ED. Notably, BMED has more environmental benefits and will be more economically attractive as the control on secondary pollution is strengthened and the bipolar membrane cost decreases.

Dialysis↗

Removal of fluoride from water using anion-exchange membrane under Donnan dialysis condition.

The transport of fluoride through Neosepta-ACM anion-exchange membrane has been studied as a function of feed phase and receiver phase concentration and co-existence anions under Donnan dialysis condition. It was observed that the transport of fluoride was maximum at pH 6 of feed phase and at pH 1 of receiver phase. Moreover, transport of fluoride increased with increase of feed and receiver phase concentration and decreased in the presence of other co-existence anions in the feed phase. The transport of fluoride was also correlated with the flux data and explained according to structure of membrane.

Dialysis↗