Search PubMedSearch

PubMed · 3430373

Multichannel compression processing for profound deafness.

Abstract

Three-channel amplitude compression followed by frequency shaping was used to process test sentences for five profoundly deaf subjects, and the recognition scores were compared to scores achieved with frequency shaping only. At preferred levels, the scores of three of the five subjects showed a statistically significant but not dramatic advantage for compression; the averages of the scores for these three subjects were 29.2 percent for the uncompressed speech and 39.5 percent for the compressed speech. The preferred-level scores of the other two subjects did not show a statistically significant advantage for compression; averages were 33.7 percent for uncompressed speech and 36.1 percent for compressed speech. Tests at input levels 10 dB and 15 dB below preferred levels were also given to four of the subjects (the fifth had to leave the experiment early). In the reduced-level tests all four subjects showed a statistically significant advantage for compression. The averages of reduced-level uncompressed scores for the four subjects were 10.7 percent and 15.2 percent at -15 dB and -10 dB levels, compared to compressed scores at these levels of 31.7 percent and 32.5 percent. When visual cues were added to the auditory presentation in an exploratory experiment with one subject, the benefit of compression carried over into the higher scores.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Villchur. 1987. Multichannel compression processing for profound deafness.. https://pubmed.ncbi.nlm.nih.gov/3430373/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acoustic probe-based ELISA.

The effects of acoustic microstreaming during incubation steps of a prototypical three-step ELISA were studied. Acoustic microstreaming, an orderly mixing of microwell contents induced by linear oscillation of immersible acoustic probes, was shown to be particularly effective when coupled with locating the solid phase on the surface of the probes. Optical densities achieved for acoustic probe-based assays were equivalent to those for uninsonated microwell-based assays with only 20% of the microwell solid phase surface area. Low-level antibody detection was significantly improved and antibody incubation times significantly shortened without loss of signal. Acoustic probe-based assays can enhance assay and laboratory efficiency through testing for multiple analytes in a single sample or increasing available binding surface area (by using probe and well surfaces simultaneously), and by eliminating quenching. Acoustic probe ELISA methodology has significant implications for cost-effective automation.

Acoustics