Search PubMedSearch

SEARCH · Search PubMed

Results for “Microcomputers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

The microcomputer and image analysis in diagnostic pathology.

This paper presents a snapshot view of the influence and direction of microcomputer technology for image analysis techniques in diagnostic pathology. Microcomputers have had considerable impact in bringing image analysis to wider application. Semi-automated tracing techniques are a simple means of providing objective data and assist in a wide range of diagnostic problems. From the common theme of reducing subjectivity in diagnostic assessment, an extensive body of research has accrued. Some studies have addressed the need for quality control for reliable, routine application. Video digitizer cards bring digital image analysis within the reach of laboratory budgets, providing powerful tools for investigation of a wide range of cellular and tissue features. The use of staining procedures compatible with quantitative evaluation has become equally important. As well as assisting scene segmentation, cytochemical and immunochemical staining techniques relate the data to biological processes. With the present state of the art, practical use of microcomputer based image analysis is impaired by limitations of information extraction and specimen throughput. Recent advances in colour video imaging provide an extra dimension in the analysis of multi-spectral stains. Improvements will also be felt with predictable increase in speed of microprocessors, and with single chip devices which deliver video rate processing. If the full potential of this hardware is realized, high-speed, routine analysis becomes feasible. In addition, a microcomputer imaging system can play host to companion functions, such as image archiving and transmission. With this outlook, the use of microcomputers for image analysis in diagnostic pathology is certain to increase.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

Rapid evolution of microcomputer use in a faculty of health sciences.

OBJECTIVE: To assist with educational planning we surveyed health sciences faculty members in 1989 to determine their use of microcomputers, desire for further instruction and perceptions on what microcomputer services should be provided for students. The 1989 results were compared with those of a similar survey performed in 1986. DESIGN: A self-completed, mailed questionnaire, with up to three reminders. SETTING: Faculty of Health Sciences, McMaster University, Hamilton, Ont. PARTICIPANTS: All full-time (FT) and part-time (PT) faculty members were sent the questionnaire; over 80% of the FT and 65% of the PT faculty members responded in 1986 and in 1989. RESULTS: The proportions of faculty members who used microcomputers increased significantly over the 3 years, from 71% to 87% among FT members (p = 2.2 x 10(-8)) and from 48% to 69% among PT members (p = 4.9 x 10(-8)). There were significant increases in the use of many of the applications, especially database and filing uses (from 10% to 41% among FT members [p less than 1 x 10(-9)] and from 6% to 34% among PT members [p less than 1 x 10(-9)]) and on-line access to bibliographic databases (from 7% to 37% among FT members [p less than 1 x 10(-9)] and from 3% to 18% among PT members [p less than 1 x 10(-9)]. These changes occurred mainly through individual initiative and voluntary continuing education. CONCLUSIONS: The extraordinary rate of adoption of microcomputers attests to their perceived usefulness. Curriculum planners need to consider how the success of microcomputer applications can be evaluated objectively and how successful applications can be integrated into educational programs.

Attitude of Health Personnel

Development of a microcomputer-based system to quantify the effective dose of drug through epithelial cells.

It is well documented that the rate-limiting step of pharmaceutical investigation is the amount of drug absorbed through the epithelial cells, not the total dose taken. To date, the only measure of the effective dose of medication is by measuring the circulating level of the ingested medication. This mode of measurement is neither accurate nor practical in determining the active ingredient required. However, a more efficient method of testing which constitutes simplicity and practically is desired. The aim of this project was the design of a microcomputer-based system for detecting and quantifying steroid hormones taken up by mucosal intestinal cells in vitro, for eventual in vivo application in animals and humans. A microcomputer-based system capable of controlling and monitoring four cell membranes simultaneously has been designed, consisting of a microcomputer system and a data acquisition subsystem. The data acquisition subsystem consists of instrumentation amplifiers with an analog-to-digital converter and digital-to-analog converter. This subsystem converts the ionic exchanges first to electrical signals, and then to digital format, to be processed and stored by the microcomputer. Subsequently, the stored information can be clinically interpreted. Due to the complexity of membrane behavior (nonlinear) in response to feedback control signals, software development was difficult. Therefore, a unique scheme was developed to control various unexcitable tissues in order to reach the predetermined values very rapidly, and then to collect cell membrane data periodically.

Drug Monitoring

Comparison of six microcomputer dietary analysis systems with the USDA Nutrient Data Base for Standard Reference.

We compared the general operating features and nutrient databases of six microcomputer dietary analysis systems. A 3-day food record with 73 food items was entered into each program; nutrient averages were compared with the US Department of Agriculture Nutrient Data Base for Standard Reference (USDA NDB), full version, release 9, for microcomputers. The six programs were found to vary widely in cost, number of foods and nutrients in the database, use of non-USDA data and imputation of data for missing values, number of print/export options, time to analyze the 3-day food record, and overall ease of use. Although all of the microcomputer dietary analysis systems were within 7% of the USDA NDB for energy, protein, total fat, and total carbohydrates, the proportion of other nutrients varying more than 15% from the USDA NDB varied considerably between programs. Variance among programs for 3-day food record nutrient values occurred because of differences in the number of food items included in the database (leading to varying degrees of substitution), the recency of the nutrient data (whether or not the most recent USDA releases had been incorporated), and the number of missing values (the degree to which non-USDA sources or estimated calculations were used to fill in the blanks from the USDA standard). Our results demonstrate that it is important for each dietitian to carefully choose a microcomputer dietary analysis system that is suitable to specific and predetermined needs.

Databases, Factual

Nonlinear least-squares regression programs for microcomputers.

Nonlinear least-squares regression can be performed on a microcomputer with BASIC language capability and 8K or more bytes of random access memory. At least five nonlinear regression programs written in BASIC exist, two of which have been implemented on microcomputers. These programs and some of their characteriscics are described. Advantages and disadvantages of performing nonlinear regression on microcomputers are contrasted with use of nonlinear regression programs requiring large computers.

Computers

A new method for analyzing smooth-pursuit eye movements. Description of a microcomputer program and evaluation in healthy volunteers.

The study of ocular movements has been increasingly used to detect subtle pathological modifications, caused by a wide variety of neurological diseases. We have developed a new microcomputer-based method for the analysis of smooth-pursuit ocular movements induced by constant velocity targets moving unpredictably at different velocities (including velocity values as high as 100 deg/s). The ocular movements are recorded by an electro-oculographic technique using silver-silver chloride electrodes fixed near the inner and outer canthi of both eyes. The signals are amplified by two DC amplifiers after a low-pass filtering (50 Hz), sampled at 250 Hz and digitized in a 12-bit form by an analog/digital converter. For each patient's evaluation, a series of 20 sweeps of the target is generated. The data analysis, which is performed automatically by the microcomputer, is based on the calculation of four parameters: average peak eye velocity (APEV); typical target velocity (TTV); percent target matching index after saccade removal (PTMI); typical matching target velocity (TMTV) after saccade removal. APEV is calculated as the average of the peak velocities estimated from the 20 sweeps. The purpose of TTV, which is defined as the value of target velocity at which the percent gain has decreased to slightly more than one third of the maximum percent gain, is to provide an overall index of the rate at which the percent gain decreases as the target velocity increases. PTMI describes the eye performance for each value of target velocity.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

EEG data acquisition and preprocessing by microcomputer satellite system.

Recent development in computer technology allows already medium scale EEG data processing to be performed within the clinical neurophysiology department, if a fast minicomputer with adequate mass storage and graphical output facilities is used. Data acquisition, however, should be delegated to a microcomputer which also should take over as much preprocessing as possible. A system is presented, where one or several microcomputer-based satellite units perform analog-digital conversion, Fourier transformation (FFT), calculation of power spectra and crossproducts, as well as event related averaging or other preprocessing procedures. The units are connected to a fast central minicomputer, where a supervisor program loads the microprocessors with their programs, supervises their activity, receives preprocessed data and activates appropriate postprocessing programs to produce the final results.

Analog-Digital Conversion

Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

Artificial Limbs

A model of a microcomputer database system to assist medical schools in recruiting and retaining students.

A model for a microcomputer database to aid a school's efforts to recruit and retain students is presented. The model is based upon a working system developed by the author at the University of Colorado Health Sciences Center. The article discusses data needs for adequate records of the recruitment and retention efforts, especially those concerning minority students, and how these records can be used to administer and evaluate programs. The model provides a framework for microcomputer data files, record fields, relationships, and system development and maintenance considerations.

Colorado

The use of microcomputer-based psychomotor tests for the evaluation of benzodiazepine effects on human performance: a review with emphasis on temazepam.

1. The literature relating to the effects of benzodiazepines in general, and temazepam in particular, on human psychomotor performance as assessed using microcomputer-based testing batteries is surveyed. 2. The adverse effects of central nervous system depressants on performance is an important mediocolegal issue and frequently comes into question in on-the-road and on-the-job accidents. The use of microcomputer-based testing batteries allows for performance evaluation both in the laboratory and at-the-scene, as well as providing the opportunity to model a large number of different behaviours required in routine yet complex psychomotor tasks. 3. The conclusions in general are: (1) The benzodiazepines as a class of drugs impair both cognitive and motor performance. These effects are often subtle when low doses are involved or when testing occurs the morning following evening administration of the medication. (2) No single psychomotor task adequately simulates complex daily tasks such as automobile driving. A battery of tests that evaluates a number of the components of such tasks is necessary to determine adequately the full range of effects of these medications.

Benzodiazepines

Measuring children's social skills using microcomputer-based videodisc assessment.

This article describes the development of a microcomputer-based videodisc assessment prototype for measuring children's social skills. The theoretical and empirical foundations for the content are described, and the contributions of interactive microcomputer-based video technology to assessment of children with handicaps are detailed. An application of Goldfried and D'Zurilla's "behavior-analytic" approach to development of the content of assessments is presented, and the related video and computer technology development is detailed. The article describes the conceptual foundations of the psychometrics of the assessment prototype as well as the psychometric methodology that was employed throughout the development process. Finally, a discussion of the potential applications and implications of the social skills assessment prototype is included.

Child

[Sexual differences in functional hemispheric asymmetry: verbal tachistoscopic evaluation using microcomputers].

Study of sexual differences for the hemispheric prevalence on visual verbal stimuli using a microcomputer-based tachistoscope technic. Seventeen right-handed individuals, 10 males and 7 females (mean age 32 years old), without neurological or visual abnormalities were studied. The subjects performed a verbal trigram tachistoscope test, using a IBM PC microcomputer compatible. The trigram consists of 80 consonant-vowel-consonant pairs of stimuli presented randomly to right and left visual fields. The evaluation was made through two conditions: T1 and T2. In T1 Experiment stimuli exposition time was 260 ms, and in T2 Experiment the stimuli exposition time was 160 ms. In T1 Experiment 80% of females showed a Right Hemispherical Preference while 100% of males showed a Left Hemispherical Preference. In T2 Experiment, both sexes showed Left Hemispheric Preference. A close relationship between sexual difference and hemispheric preference was found. We point out the importance of stimuli exposition time in determination of sexual differences in lateral hemispherical asymmetry.

Adult

A comprehensive microcomputer network program for histopathology.

For a small hospital with a limited budget, a stand-alone histopathology microcomputer network may be more valuable to the pathologist than one running off the hospital's main computer. In return for sacrificing the limited benefit of screen reading of pathology reports in the wards, one receives the great advantage of more rapid retrieval of disease data. Commercial relational database programs for microcomputers can now achieve nearly all the power of a minicomputer program, with more versatility. Using an application developed on such software, we now have 30,000 pathology reports entered, from which we can retrieve a list of pathology numbers, with patients' names, age, sex, disease, and site, for any diagnosis in 3-5 seconds. The application includes full biopsy reports for doctors and wards, autopsy final diagnoses, computer-assisted Snomed coding, outside consultations, literature abstracts, daybook printing, workload statistics and billing codes and charges, and a cytology module has been added for another hospital. Moreover, the interested pathologist can easily make his own alterations to menus, entry screens, fields, and screen listing or printout formats.

Computer Communication Networks

[The teaching of primary health care: diagnostic and educational evaluation by microcomputers].

The study aims to explore the utilization of the Formative Evaluation by the microcomputer in the teaching of primary attention to the health. The experiment is composed of eight modules, programmed in Basic software "Formative Evaluation". For each module, a "Question Bank" with three sorts of feedbacks was organized. The sample includes 16 subjects. The results show that the Formative Evaluation by Microcomputer proportioned to the students a cognitive domain significantly higher than the traditional instruction. However, it didn't provide a significantly superior performance to the students who experienced this system.

Brazil

Incidence of symptomatic mild hypoglycaemic events: a prospective study in adult patients with insulin-treated diabetes mellitus using a portable microcomputer-based data-logger.

A new method for recording mild symptomatic hypoglycaemic events was evaluated. A pilot study was conducted using a portable microcomputer-based data-logger which was carried for 10 days by 38 adult patients with insulin-treated diabetes mellitus. The patients recorded symptomatic hypoglycaemic events, meals and sleeping-hours. The recording was prospective and continuous and did not allow any corrections afterwards. No patients had any problems in carrying or handling the data-logger and compliance was good. A total of 76 hypoglycaemic events were recorded in 29 patients. Two patients had hypoglycaemic events that they were unable to manage without help from another person. There was a peak in the incidence of hypoglycaemic events late postprandially, particularly in patients treated with a four-dose insulin regime with fast-acting insulin before meals. A portable microcomputer-based data-logger is a reliable new method for recording symptomatic mild hypoglycaemic events. The incidence of mild hypoglycaemic events was higher than previously reported.

Adult

A microcomputer system for assessment of peripheral blood flow. An example of nasal blood flow.

We have designed and implemented a microcomputer system for studying the effect of various mediator substances on the nasal blood flow. The system uses an IBM PC/AT microcomputer, which is connected with a Laser Doppler Flowmeter (LDF) and an iontophoretic drug application system. The LDF measures flux from the tissue that in the example is the inferior nasal turbinate. The flux is converted to digital form by an analog-digital converter of 12 bits. The program is implemented in the Pascal language. In the analysis, a flux level, amplitude, rise time and decay time of the pulse wave are determined. The effect of drugs on the flux can be studied by applying them iontophoretically. In the program the length and number of the drug application periods as well as the recording period are user-driven. In the nasal blood flow iontophoretically administered adrenaline reduced significantly the flux parameters and histamine canceled this effect. Tachyphylalaxis was a frequent observation in repeated measurements. The system can be used to evaluate the role of different transmitters in the etiology of chronic rhinitis.

Adult

Analysis of evoked potentials in measuring-analyzing ENG-microcomputer system.

The microcomputer system of measurement and analysis of equilibrium organ examinations was performed in the paper. Organization and functions of computer file of examined patients and results of anamnesis and organization of measuring course were discussed. Detailed description of used technique and methodology, kind identification of ENG diagnostic parameters, obtained results and forms of its graphic presentations on microcomputer monitor or graphic printer was performed.

Electronystagmography

Microcomputer controlled titration for determination of protein nitrogen in feeds and wheat.

The determination of protein nitrogen in feeds and wheat by microcomputer controlled titration is described. The method involves direct titration of ammonia with standard hypochlorite titrant in the presence of bromide. The titrant is delivered by an automatic buret, and the microcomputer controlled, automatically computed potentiometric end points are precise to 0.1% over a 5-fold concentration range of nitrogen. Digestions performed with both mercury and copper catalysts show comparable results. Samples are weighed before digestion by an electronic balance interfaced to the computer which records sample number and weight. An automatic pipet aliquots, dilutes, and buffers samples directly from the digestion tubes; the samples can be immediately titrated with the automatic titrator. The results for protein in NBS standards and check feed samples from an offical testing program compare closely with average values reported for these standards. Results show that feed and wheat samples contained 10-100% protein. Precision for successive aliquots of the same digests is 0.1-0.4%relative standard deviation; precision for multiple digestions of the same sample is 0.1-0.8%.

Animal Feed