A program in BASIC suitable for personal computers is described which is applicable to gel electrophoresis conducted in a single (continuous) buffer. The curve fitting is to a polynomial function, allowing for an objective selection of the most appropriate curve type and order--linear, convex or concave--in the particular application. Results do not differ significantly from previous programs for evaluation of linear Ferguson plots or of curve fitting to an exponential function for evaluating convex plots, executed on mainframe computers such as the DEC-10 (Digital) and IBM 370 computers. Thus, the program combines original versatility with, for the first time, the possibility for widespread application of Ferguson plot analysis on personal computers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Gombocz, A Chrambach. 1989. Program in BASIC for Ferguson plot analysis, using a personal computer: application to gel electrophoresis in a continuous buffer.. https://doi.org/10.1002/elps.1150100309

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

von Willebrand factor characterization of a severe dry-heat treated factor VIII concentrate, AHF (high purity).

Eight batches of a severe dry-heat treated (80 degrees C for 72 hours) Factor VIII concentrate manufactured by the Commonwealth Serum Laboratories (CSL Ltd.) were analysed for the following von Willebrand factor-related (vWf) activities: ristocetin cofactor activity (vWf:RCof), collagen binding activity (CBA), vWf antigen levels (vWf:Ag), vWf multimeric analysis and 2-stage FVIII clotting activity (VIII:C). The average potency per vial of vWf:Ag was 440 +/- 80 units, vWf:RCof 500 +/- 60 units, CBA 350 +/- 50 units and VIII:C 242 +/- 36 International Units. Multimeric analysis indicated the presence of high molecular weight multimers and a triplet structure slightly different to normal plasma. Viral inactivation studies using a marker virus, Sindbis, demonstrated that the terminal severe dry- heating step reduced the viral load in the product by greater than 6 log10TCID50/ml. This CSL Ltd. FVIII concentrate may thus provide a safer, purer and more convenient source of vWf than cryoprecipitate. Clinical studies to establish product efficacy in patients with von Willebrand's disease are underway.

Blood Protein Electrophoresis

Hypertrophic obstructive cardiomyopathy in a neonate with the carbohydrate-deficient glycoprotein syndrome.

The carbohydrate-deficient glycoprotein (CDG) syndrome in its most severe form (neonatal olivopontocerebellar atrophy) is a life-threatening multisystem disease. We report a neonate who was referred for cardiological assessment because of respiratory distress, a murmur and episodes of desaturation. After initial spontaneous improvement he presented at 9 weeks with evidence of a severe hypertrophic obstructive cardiomyopathy (HOCM). The diagnosis of CDG syndrome was suggested by the characteristic dysmorphic features, hypotonia, visual inattention and severe failure to thrive; it was confirmed by electrophoresis of serum transferrin. HOCM can be a feature of the CDG syndrome, in addition to the (previously reported) pericardial effusions.

Blood Protein Electrophoresis