Search PubMed⌕ Search

PubMed · 2188389

Corrective measures for myopia.

Abstract

Many myopic people, expressing dissatisfaction with traditional methods of optical correction, are interested in a permanent correction of their refractive error which would alleviate dependence on corrective lenses. Although much effort has been put forth in the last century, there is still no method of correcting myopia which is broadly acceptable as safe and effective. The nonsurgical procedures of orthokeratology and the topical use of cycloplegics have not been well proven. Surgical measures are the current vectors of hope. Surgical procedures on parts of the eye other than the cornea have proven to be difficult. Surgery which alters the refractive power of the cornea (refractive keratoplasty) has been used frequently in the past decade. These procedures include keratomileusis, epikeratophakia and radial keratotomy. The latter is currently the most often performed method for the correction of myopia. This paper critiques the major methods, explains their historical development and basic procedures, lists major published studies and discusses their problems and promise for their future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D R Wilson, A H Keeney. Corrective measures for myopia.. https://doi.org/10.1016/0039-6257(90)90028-t

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Wide-angle viewing lens for vitrectomy.

PURPOSE: To report a new wide-angle viewing contact lens for vitrectomy. DESIGN: New surgical instrument. METHODS: The new wide-angle viewing lens is made of glass and polymethyl methacrylate without a plastic rim. The diameter is reduced to 16.2 mm. In addition to a smaller diameter than the currently available lens, the new lens is partially cut to reduce the lens diameter. RESULTS: A smaller diameter makes it possible to eliminate contact between surgical instruments and the wide-angle lens. Instruments can be inserted through sclerotomies without removing the wide-angle lens. The optical properties are otherwise identical to the standard wide-angle lens. CONCLUSION: The new wide-angle viewing lens may be easier to use in vitreous surgery.

Contact Lenses↗

Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moieties.

The instrument oxygen transmissibility (IOT) of organosilicon hydrogels, measured by electrochemical procedures, is 5-10 times larger than that of conventional hydrogels. A method is described that allows the estimation of the oxygen tension at the lens-cornea interface for closed- and open-eyelids situations by combining the IOT of the hydrogels and corneal parameters such as corneal thickness, corneal permeability and oxygen flux across the cornea. From these results the biological oxygen apparent transmissibility (BOAT) is obtained, an important parameter which an multiplication with the pressure of oxygen on the external part of the lens gives the oxygen flux onto the cornea. Contact lenses with oxygen transmissibility higher than 100 Dk/t units [1 Dk/t unit=10(-9) [cm(3) O(2) (STp) cm(-2)s(-1)(mmHg)(-1)] posses a large oxygen tension at the lens-cornea interface that substantially reduces the oxygen flux onto the cornea. Lenses whose oxygen transmissibility is lower than 50 Dk/t units allow a rather small oxygen flux onto the cornea under closed eyelids condition that prevent their use for extended wear.

Contact Lenses↗